VDE HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY FEATURES 10 .394 20 .787 JQ RELAYS • High electrical noise immunity • High switching capacity in a compact package • High sensitivity: 200 mW (1a), 400 mW (1c) • High surge voltage: 8,000 V between contacts and coil • UL, CSA, VDE, TÜV, SEMKO approved • Class B coil insulation type available 15.6 .614 mm inch SPECIFICATIONS Contact Characteristics Standard type High capacity type 1 Form A, 1 Form C Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material 1a Nominal switching capacity N.O. 1c Rating (resistive) N.C. 100 mΩ Silver alloy 5 A 125 V AC 10 A 125 V AC 2 A 250 V AC 5 A 250 V AC 5 A 30 V DC 5 A 30 V DC 5 A 125 V AC 10 A 125 V AC 2 A 250 V AC 5 A 250 V AC 3 A 30 V AC 5 A 30 V DC 2 A 125 V AC 3 A 125 V AC 1 A 250 V AC 2 A 250 V AC 1 A 30 V DC 1 A 30 V DC 1a 625 VA, 150 W 1,250 VA, 150 W N.O. 625 VA, 90 W 1,250 V AC, 150 W 1c N.C. 250 VA, 30 W 500 V AC, 30 W Max. switching voltage 250 V AC, 110 V DC (0.3A) Max. switching current N.O.: 5 A N.C.: 2 A N.O.: 10 A N.C.: 3 A Expected mechanical life 107 (at 180 cpm)(min. operations) Max. switching power 1a Standard type N.O. 1c N.C. 1a High capacity type N.O. 1c N.C. Switching capacity 5 A 125 V AC 3 A 125 V AC 2 A 250 V AC 5 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 3 A 125 V AC 2 A 250 V AC 1 A 30 V DC No. of operations 5×104 2×105 2×105 105 5×104 2×105 105 2×105 2×105 105 5×104 5×104 105 5×104 5×104 105 2×105 2×105 105 1a: 200 mW 1c: 400 mW 5 A 125 V AC 2 A 250 V AC 3 A 30 V DC 2 A 125 V AC 1 A 250 V AC 1 A 30 V DC Initial Between open contacts breakdown voltage*2 Between contacts and coil Surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time*4 (at nominal voltage)(without diode) Temperature rise*5 Functional*6 Shock resistance Destructive*7 Vibration resistance Functional*8 Destructive Conditions for operation, Ambient transport and storage*9 temp.*10 (Not freezing and condensHumidity ing at low temperature) Unit weight Expected electrical life (min. operations) Type Max. operating speed Initial insulation resistance*1 20 cpm Min. 1,000 MΩ at 500 V DC 1a: 1,000 Vrms for 1 min. 1c: 750 Vrms for 1 min. 4,000 Vrms for 1 min. 8,000 V Approx. 5 ms Approx. 2 ms Max. 45°C Min. 294 m/s2 {30 G} Min. 980 m/s2 {100 G} 98 m/s2 {10 G}, 10 to 55 Hz at double amplitude of 1.6 mm 117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2.0 mm –40°C to +85°C –40°F to +185°F 5 to 85% R.H. Approx. 7 g .25 oz Remarks * *1 *2 *3 *4 *5 Specifications will vary with foreign standards certification ratings. Measurement at same location as "Initial breakdown voltage" section Detection current: 10 mA Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 Excluding contact bounce time Measured conditions Standard type High capacity type *6 *7 *8 *9 *10 Resistive, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70°C 158°F Resistive, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70°C 158°F Half-wave pulse of sine wave: 11ms; detection time: 10µs Half-wave pulse of sine wave: 6ms Detection time: 10µs Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with 20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range. Coil (at 20°C 68°F) Nominal operating power 71 JQ TYPICAL APPLICATIONS • Air conditioners • Refrigerators • Microwave ovens • Heaters ORDERING INFORMATION Ex. JQ 1a P B 12 V Contact arrangement Contact capacity Coil insulation class Coil voltage (DC) 1a: 1 Form A 1: 1 Form C Nil: Standard P: High capacity Nil: Class E coil insulation B: Class B coil insulation 5, 6, 9, 12, 18, 24, 48* V UL/CSA, VDE, SEMKO approved type is standard. * Available only for 1 Form C type TYPES AND COIL DATA at 20°C 68°F 1 Form C 72 Standard type High capacity type High capacity type Standard type 1 Form A Part No. JQ1a-5V JQ1a-6V JQ1a-9V JQ1a-12V JQ1a-18V JQ1a-24V JQ1aP-5V JQ1aP-6V JQ1aP-9V JQ1aP-12V JQ1aP-18V JQ1aP-24V JQ1-5V JQ1-6V JQ1-9V JQ1-12V JQ1-18V JQ1-24V JQ1-48V JQ1P-5V JQ1P-6V JQ1P-9V JQ1P-12V JQ1P-18V JQ1P-24V JQ1P-48V Nominal voltage, V DC Pick-up voltage, V DC (min.) Drop-out voltage, V DC (min.) Nominal operating current, mA 5 6 9 12 18 24 5 6 9 12 18 24 5 6 9 12 18 24 48 5 6 9 12 18 24 48 3.75 4.5 6.75 9 13.5 18 4 4.8 7.2 9.6 14.4 19.2 3.75 4.5 6.75 9 13.5 18 36 4 4.8 7.2 9.6 14.4 19.2 38.4 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 2.4 0.25 0.3 0.45 0.6 0.9 1.2 2.4 40 33.3 22.2 16.7 11.1 8.3 40 33.3 22.2 16.7 11.1 8.3 80 66.7 44.4 33.3 22.2 16.7 8.3 80 66.7 44.4 33.3 22.2 16.7 8.3 Nominal operating power, mW 200 200 400 400 Coil resistance, Ω (±10%) 125 180 405 720 1,620 2,880 125 180 405 720 1,620 2,880 62.5 90 202.5 360 810 1,440 5,760 62.5 90 202.5 360 810 1,440 5,760 Max. allowable voltage, V DC 180% of nominal voltage (at 20°C 68°F) 130% of nominal voltage (at 85°C 185°F) 150% of nominal voltage (at 20°C 68°F) 110% of nominal voltage (at 85°C 185°F) JQ mm inch DIMENSIONS 1 Form A 10 .394 1 Form A 20 .787 Schematic (Bottom view) 1 Form C COM N.O. COM Coil 15.6 .614 N.O. Coil N.C. 0.4 .016 4.2 .165 0.5 dia. .020 dia. 7.62 .300 10.16 .400 0.3 .012 7.62 .300 7.62 .300 0.3 .012 0.8 .031 PC board pattern (Copper-side view) 1 Form A 1FormC 1 Form C 10 .394 20 .787 10.16 .400 4-1.3 dia. 4-.051 dia. 7.62 .300 15.6 .614 10.16 .400 7.62 .300 7.62 .300 0.4 .016 7.62 .300 4.2 .165 0.5 dia. .020 dia. 5-1.3 dia. 5-.051 dia. 7.62 .300 Tolerance: ±0.1 ±.004 10.16 .400 0.3 .012 Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .118 inch Min. 5mm .118 inch 5.08 .200 2.54 .100 0.3 .012 0.3 .012 7.62 .300 0.8 .031 General tolerance ±0.2 ±.008 ±0.3 ±.012 ±0.4 ±.016 REFERENCE DATA Max. switching capacity (1 Form A type) Max. switching capacity (1 Form C type) 100 AC resistive load (High capacity type) 10 5 Contact current, A Contact current, A 100 10 5 3 2 AC resistive load 1 (High capacity type) N.C. side AC resistive load (Standard type) N.C. side 1 AC resistive load (Standard type) 10 AC resistive load (High capacity type) N.O. side AC resistive load (Standard type) N.O. side 100 277 10 1,000 100 277 1,000 Contact voltage, V Contact voltage, V Standard type 1-(1). Operate & release time (1 Form A type) 1-(2). Operate & release time (1 Form C type) Tested sample: JQ1a-12V, 25 pcs. Tested sample: JQ1-24V, 25 pcs. 2. Life curve Ambient temperature: room temperature 6 Operate time 4 2 Release time 0 Max. Max. Min. Min. 8 6 Operate time 100 120 150 Coil applied voltage, %V 10 4 250V AC resistive load Max. Max. Min. Min. 2 Release time 0 80 125V AC resistive load Life, ×104 8 Operate & release time, ms Operate & release time, ms 100 80 100 120 150 Coil applied voltage, %V 1 0 1 2 3 4 5 Contact current, A 73 JQ 3-(1). Coil temperature rise (1 Form A type) 3-(2). Coil temperature rise (1 Form C type) Contact carrying current: 3 A, 5 A Measured portion: Inside the coil Contact carrying current: 3 A, 5 A Measured portion: Inside the coil 70 40 Temperature rise, °C Temperature rise, °C 50 5 A at 70°C 5 A at 85°C 30 20 3 A at 70°C 60 5 A at 70°C 50 3 A at 70°C 40 5 A at 85°C 30 3 A at 85°C 20 3 A at 85°C 10 10 0 0 100 110 120 130 140 150 160 170 180 190 100 110 120 Coil applied voltage, %V 130 140 150 160 Coil applied voltage, %V 4-(1). Ambient temperature characteristics (1 Form A type) 4-(2). Ambient temperature characteristics (1 Form C type) Tested sample: JQ1a-24V Contact carrying current: 3 A, 5 A Tested sample: JQ1-24V Contact carrying current: 3 A, 5 A 400 300 1 2 200 3 5 6 4 Coil applied voltage, %V Coil applied voltage, %V 400 100 300 1 3 4 5 100 6 7 0 2 200 20 30 40 50 60 70 80 0 90 20 30 7 40 Ambient temperature, °C 50 60 70 80 90 Ambient temperature, °C 1 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130°C 266°F) (Carrying current: 3 A) 2 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130°C 266°F) (Carrying current: 5 A) 3 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) (Carrying current: 3 A) 4 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) (Carrying current: 5 A) 5 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A) 6 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 3 A) 7 Pick-up voltage High capacity type 1-(1). Operate & release time (1 Form A type) 1-(2). Operate & release time (1 Form C type) 2. Life curve Tested sample: JQ1aP-12V, 25 pcs. Tested sample: JQ1P-12V, 25 pcs. Ambient temperature: room temperature 6 Operate time 4 Max. Min. Max. Min. 2 0 100 120 6 Operate time Max. Max. Min. Min. Release time 0 150 80 100 Coil applied voltage, %V 120 3-(1). Coil temperature rise (1 Form A type) 3-(2). Coil temperature rise (1 Form C type) Contact carrying current: 5 A, 10 A Measured portion: Inside the coil Contact carrying current: 5 A, 10 A Measured portion: Inside the coil 50 10 A at 70°C 40 5 A at 70°C 30 Temperature rise, °C Temperature rise, °C 10 A at 85°C 10 A at 85°C 60 10 A at 70°C 50 5 A at 70°C 40 5 A at 85°C 30 5 A at 85°C 20 20 10 10 0 100 120 140 160 180 Coil applied voltage, %V 74 0 100 110 120 130 140 150 Coil applied voltage, %V 0 2 4 6 8 Contact current, A 70 60 250V AC resistive load 1 150 Coil applied voltage, %V 70 125V AC resistive load 10 4 2 Release time 80 8 Life, ×104 8 Operate & release time, ms Operate & release time, ms 100 160 10 JQ 4-(1). Ambient temperature characteristics (1 Form A type) 4-(2). Ambient temperature characteristics (1 Form C type) Tested sample: JQ1aP-24V Contact carrying current: 5 A, 10 A Tested sample: JQ1P-24V Contact carrying current: 5 A, 10 A 400 1 Coil applied voltage, %V Coil applied voltage, %V 400 2 300 200 3 5 4 100 1 2 200 3 4 5 100 6 0 300 20 30 6 7 40 50 60 70 80 Ambient temperature, °C 90 0 20 30 7 40 50 60 70 80 Ambient temperature, °C 90 1 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130°C 266°F) (Carrying current: 5 A) 2 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130°C 266°F) (Carrying current: 10 A) 3 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) (Carrying current: 5 A) 4 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) (Carrying current: 10 A) 5 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 10 A) 6 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A) 7 Pick-up voltage For Cautions for Use, see Relay Technical Information (Page 11 to 39). 12/27/2002 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. 75 Go To Online Catalog