Keysight Technologies M9005A PXIe Chassis Integrated System Module, 5-slots, 3U Data Sheet Introduction The Keysight Technologies, Inc. M9005A PXIe 5-slot chassis is the smallest footprint family member of Keysight’s PXIe chassis product line. It has been designed as a low cost, bench friendly solution while still enabling PXIe compatibility and performance. The integrated system module enables a solution that is fast and easy to setup. The combination of footprint, cost, and performance make it a perfect entry-level chassis for many applications. Key Features –– Small footprint, bench friendly, 4U PXIe chassis –– 5 peripheral slots: 3 PXIe hybrid slots, 2 PXIe-only slots –– Integrated PXIe Gen1 x1 system module for use with desktop host adapter –– Up to 250 MB/s total system bandwidth –– Up to 250 MB/s per-slot data bandwidth –– Specified up to 50 °C and 2000 m operating conditions 03 | Keysight | M9005A PXIe Chassis - Data Sheet Hardware Overview Backplane configuration The M9005 PXIe chassis provides 5 peripheral slots: 3 hybrid-compatible slots and 2 PXI Express for a combination of measurement flexibility and performance. Each slot has a PCIe ® x1 Gen 1 link to the upstream PC. Each hybrid peripheral slot can accept a PXI Express peripheral module, a CompactPCI Express Type-2 peripheral, or a PXI-1 module which has the J2 connector replaced with the XJ4 connector. The hybrid slots provide full PXI Express and 32-bit PXI functionality. Figure 1. Backplane configuration diagram of the M9005A PXIe 5-slot chassis. 04 | Keysight | M9005A PXIe Chassis - Data Sheet Software Overview The M9005A provides a simple use model. The only necessary software is low level chassis driver which allows the system PXI resource manager to enumerate the M9005A chassis and the installed modules. Keysight Standard Warranty With Keysight’s standard warranty, your investment is protected by Keysight’s global reach in more than 100 countries (either directly or through distributors). The warranty gives you convenient standard coverage for the country in which the product is used, eliminating the need to ship equipment back to the country of purchase. Keysight’s warranty service provides: –– All parts and labor necessary to return your investment to full specified performance –– Recalibration for products supplied originally with a calibration certificate –– Return shipment Definitions Specifications Warranted performance. Specifications include guardbands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions. All specifications and characteristics apply over the operating environment outlined in the “Environmental and Regulatory” section of this data sheet. In addition, the following conditions must be met: –– Instrument is within its calibration cycle if calibration is required. –– Instrument has been stored for a minimum of 1 hour within the operating temperature range prior to turn-on and after a 30 minute warm-up period. Characteristic Characteristics describe product performance that is useful in the application of the product, but that is not covered by the product warranty. Characteristics are often referred to as Typical or Nominal values. Typical Expected performance of an average unit when operated over a 20 to 30 °C temperature range. Typical performance is not warranted. The instrument must be within its calibration cycle if calibration is required. Nominal Nominal describes representative performance that is useful in the application of the product when operated over a 20 to 30 °C temperature range. Nominal performance is not warranted. Module specifications and configuration Some module specifications may be affected by chassis characteristics. Refer to module datasheet to determine the configuration used when specifications were set and to ensure module power and cooling requirements are met. Additional information All data are measured from multiple units at room temperature and are representative of product performance within the operating temperature range unless otherwise noted. The specifications contained in this document are subject to change. 05 | Keysight | M9005A PXIe Chassis - Data Sheet Technical Characteristics Chassis characteristics Standards compliance PXI-5 PXI Express hardware specification PXI-1 hardware specification rev 2.2 PICMG® EXP.0 R1.0 specification Backplane characteristics Module size 3U Total number of slots 5 Hybrid compatible slots 3 PXIe only slots 2 System slot Integrated system module. PCIe Revision 1 x1 connection to external controller PXIe timing slot Feature not available in M9005A. Consider M9010A, M9018B, M9019A chassis if required Module compatibility (depending on slot) PXIe, PXI-hybrid, PXI-1 (J1-only), and cPCI (J1-only) Backplane speed PCIe Revision 1.0 (Gen 1). x1 to each instrument slot Mechanical characteristics Size 257.1 mm W x 189.7 mm H x 212.8 mm D (with feet installed) 257.1 mm W x 177 mm H x 212.8 mm D (with feet removed) 6U x 1 rack width Weight (without modules) 5 kg (11.0 lbs) Power supply AC input Input voltage range 100-240 VAC, nominal Input frequency range 50/60 Hz Input current rating 4-2 A Over current protection All outputs protected from short circuit Available DC output power (for module slots) Total DC power Maximum total power 150 W Per slot power, for each of 5 slots 30 W DC supplies Voltage Maximum current +3.3 V 15 A +5 V 7.5 A +12 V 15 A -12 V 0.75 A 5 VAUX 1.0 A Over-voltage protection Active range Over-voltage at Minimum Maximum +3.3 V 3.76 V 4.3 V +5 V 5.75 V 7.0 V +12 V 13.4 V 15.6 V Backplane pin current capacity Slot +3.3 V +5 V + 12 V -12 V PXIe slot 6A 0A 4A 0A Hybrid slot 6A 6A 4A 1A 06 | Keysight | M9005A PXIe Chassis - Data Sheet Technical Characteristics, continued Chassis cooling and power dissipation Slot airflow direction Bottom of module to top of module Chassis cooling intake Bottom of chassis Chassis cooling exhaust Along rear, right side, and top of chassis Chassis cooling fan One 126 cfm fan on bottom of chassis with High/Auto speed selector Power dissipation, peripheral slot 38 W Power supply cooling Forced air circulation through integrated fan Power supply cooling intake Front side of chassis Power supply cooling exhaust Rear side of chassis When placed into an instrument rack or on a bench, maximum per slot power dissipation requires that the chassis bottom and top is not blocked. In an instrument rack, provide 1U rack space below and above the chassis. On the bench, the instrument feet provide the necessary bottom clearance. Slot blockers and EMC filler panels are recommended to be used in empty slots. Module cooling is affected by the module’s resistance to air flow. Clocks and triggers 10 MHz system clock (PXI_CLK10) Maximum slot-to-slot skew 250 ps Accuracy ±25 ppm max. (guaranteed over the operating temperature range) Duty factor 45%-55% Unloaded signal swing 3.3 V ±0.3 V External 10 MHz clock output feature is not available in M9005A. Consider M9010A, M9018B, M9019A chassis if required 100 MHz system clock (PXIe_CLK100) Maximum slot-to-slot skew 100 ps Accuracy ±25 ppm max. (guaranteed over the operating temperature range) Duty factor 45% - 55% Absolute single-ended voltage swing (when each line in the differential pair has 50 Ω termination to 1.30 V or Thevenin equivalent) 400 to 1000 mV External 10 MHz clock source input requirements Feature not available in M9005A. Consider M9010A, M9018B, M9019A chassis if required for synchronization. PXI star trigger Feature not available in M9005A. Consider M9010A, M9018B, M9019A chassis if required for synchronization. PXI differential star triggers Feature not available in M9005A. Consider M9010A, M9018B, M9019A chassis if required for synchronization. Host adapter characteristics Card format Low profile PCI bracket Includes low and standard profile Dimensions 6.7 cm x 7.1 cm (2.6 in x 2.8 in) Computer slot compatibility PCIe x1, x8, or x16 Maximum cable length 3m Sustained data throughput Up to 215 MB/s Power consumption 1.2 W (typ), 360 mA @ 3.3 V 07 | Keysight | M9005A PXIe Chassis - Data Sheet Technical Characteristics, continued Environmental characteristics 1, 2 Operating Storage Temperature 0 to 50 ˚C –40 to 70 ˚C Altitude Up to 6,562 ft (2,000m) at 25 °C ambient Humidity Type-tested 20 to 80%, non-condensing Type-tested 10 to 95%, non-condensing Vibration Operating random vibration 5 to 500 Hz, 0.3 g rms Survival random vibration 5 to 500 Hz, 2.4 g rms Acoustical emissions (referenced to 1pW) Auto fan (25°C ambient) High fan Sound pressure level 43 dBA 58 dBA 51 dBA 65 dBA 3 Sound power 1. Samples of this product have been type tested in accordance with the Keysight Environmental Test Manual and verified to be robust against the environmental stresses of storage, transportation and end-use. Those stresses include but are not limited to temperature, humidity, shock, vibration, altitude and power line conditions. 2. Test methods are aligned with IEC 60068-2 and levels are similar to MIL-PRF-28800F Class 3 3. At operator position Regulatory characteristics Safety Complies with the essential requirements of the European LVD Directive as well as current editions of the following standards (dates and editions are cited in the Declaration of Conformity): –– IEC/EN 61010-1 –– Canada: CSA C22.2 No. 61010-1 –– USA: UL std no. 61010-1 Acoustic statement (European Machinery Directive) –– Acoustic noise emmission –– LpA <70 dB –– Operator position –– Normal position Per ISO 7779 EMC Complies with the essential requirements of the following applicable European Directives, and carries the CE marking accordingly: Complies with European EMC Directive 2014/30/EU of the following standards (dates and editions are cited in the Declaration of Conformity): –– IEC/EN 61326-1 Basic Immunity –– CISPR pub 11 group 1, class A –– AS/NZS CISPR 11 –– ICES/NMB-001 This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme a la norme NMB-001 du Canada 08 | Keysight | M9005A PXIe Chassis - Data Sheet Recommended Configuration Configure the Keysight M9005A PXIe chassis as follows: –– Add the PC interface card –– The host adapter comes preconfigured with a 3 m PCIe cable. –– Use slot blockers and EMC filler panels in empty module slots to ensure proper module operating temperatures. –– Chassis fan may need to be set at high in order to provide required module cooling at targeted environment cooling. –– Module cooling can be impacted by each module’s resistance to air flow, therefore, refer to each module data sheet for information regarding power and cooling to ensure proper configurations. –– Place modules which have high cooling requirements in the center slots of the M9005A. For high power modules, contact your local Keysight office regarding compatibility of the M9005A with your desired modular configuration. Hardware Model Description M9005A 5-slot, PXIe chassis with integrated system module M9005A-002 PCIe Desktop adapter for M9005A + 3m cable Includes Standard PXI filler panels, getting started guide, drivers, and Keysight I/O libraries Accessories Model Description Y1212A Slot blocker kit: 5 single-slot Y1213A PXI EMC filler panel kit: 5 single-slot filler panels Y1274A Rack mount kit Services Advantage Services: Calibration Software information Supported operating systems Microsoft Windows 7 SP1 (32/64-bit) Microsoft Windows 8.1 Update 1 (32/64-bit) Microsoft Windows 10 (32/64-bit) Standard compliant drivers No IVI drivers required for this chassis Supported application development environments (ADE) LabVIEW, LabWindows/CVI, MATLAB, VEE, Visual Basic, VisualStudio.NET (C/C++, C#, VB.NET) Keysight IO Libraries Supported versions: 17.2 (or later). Use of latest version recommended. Includes: VISA Libraries, Keysight Connection Expert, IO Monitor Keysight Advantage Services is committed to your success throughout your equipment’s lifetime. Figure 2. Y1274A M9005A Rack Mount Kit. 09 | Keysight | M9005A PXIe Chassis - Data Sheet Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument’s lifecycle. Our comprehensive service offerings—onestop calibration, repair, asset management, technology refresh, consulting, training and more—helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. PCI-SIG ®, PCIe ® and the PCI Express ® are US registered trademarks and/or service marks of PCI-SIG. PICMG ® and the PICMG logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 11 2626 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. © Keysight Technologies, 2017 Published in USA, December 1, 2017 5992-1851EN www.keysight.com