PCA EPE6279S Quad interface filter module Datasheet

Quad Interface Filter Module
ELECTRONICS INC.
EPE6279S
• Optimized for Level One LXT901/944 and Quad PH (TNETE 2004)
• Complies with or exceeds IEEE 802.3, 10Base-T Standards
Electrical Parameters @ 25° C
Inductance
(µH Min.)
Interwinding
Capacitance
(pF Max.)
Leakage
Inductanc
e(µH Max.)
CMRR
(dB Min.)
[Xmit]
@ 100 KHz,
0.1 Vrms
@ 100 KHz,
0.1 Vrms
@ 100 KHz,
0.1 Vrms
@ 10
MHz
@ 50
MHz
@ 100
MHz
@ 200
MHz
5-10 MHz
@ 100Ω
5-10 MHz
@ 85Ω, 115Ω
Cable Side
Xmit/Rcv
Xmit/Rcv
Xmit
Xmit
Xmit
Xmit
Xmit/Rcv
Xmit/Rcv
200
12/12
0.3/0.3
-40
-30
-15
-10
-20/-20
-15/-15
Return Loss
(dB Min.)
Hipot
(Vrms)
Crosstalk
(dB Min.)
5-10
MHz
1500
-45
Schematic
Receive Channels
1
1:1
2
9
1:1
10
40
11
39
12
32
19
31
Transmit Channels
1:1
1:1
20
30
3
29
5
22
4
1CT : 2 CT
1CT : 2 CT
13
36
15
37
14
1CT : 2 CT
28
26
27
1CT : 2 CT
34
17
6
35
16
25
8
33
18
23
7
21
38
24
Package
1.120
(28.45)
.090
(2.29)
.050
(1.27)
.090
(2.29)
PCA
EPE6279S
Date Code
40
.480
(12.19)
.670
(17.02)
21
Solder Pad Layout
1
20
.950
(24.13)
.030
(.762)
.008/.020
(.203/.508)
.215
(5.46)
.008/.012
(.203/.305)
0°-8°
.035
(.889)
.050
(1.27)
.630
(16.00)
.016/.022
(.406/.559)
Unless Otherwise Specified Dimensions are in Inches /mm ± .010 /.25
PCA ELECTRONICS, INC.
16799 SCHOENBORN ST.
NORTH HILLS, CA 91343
Product performance is limited to specified parameters. Data is subject to change without prior notice.
CSE6279S
Rev. Orig1
5/6/03
TEL: (818) 892-0761
FAX: (818) 894-5791
http://www.pca.com