Nova OCGL3K-24-220 Dc-ac inverter Datasheet

RUGGED PORTABLE OUTDOOR
OCGL - SERIES
DC-AC INVERTERS
Input:
12, 24, or 48VDC
Output: 120V or 220V 1Ø
50 or 60Hz
Power: 2KW / 3KW
APPLICATIONS
APPLICA
AT I O N S
Utilizing field proven technology, this family of rugged
pure sinewave DC-AC Inverters is suitable for harsh
environments and can be customized for unique
applications including:
Military Shelters
Utility Applications
Tactical Systems
Mobile Systems
Ground support
Communications
MIL-STD-810
MIL-STD-461
ELECTRIC
NOVA ELE
ECTRIC
www.novaelectric.com
[email protected]
A Leader in INVERTER Technology since 1966 - 500VA to 500+KVA
MADE IN USA
PURE SINEWAVE DC-AC INVERTER
SPECIFICATIONS
FEATURES
ELECTRICAL
• Microprocessor based design with absolutely
accurate and stable frequency.
• Compact and light weight, yet rugged
and vehicle rated.
• 89-95% efficient.
• Tightly regulated output voltage and frequency
• Switch selectable 50 or 60 Hz output
• Capable of driving highly reactive loads such
as electric tools and appliances.
• Capable of driving highly capacitive loads
such as switching power supplies.
• Very low harmonic distortion, THD<3%.
• Suitable for vehicle or wall mounting.
• IP Rating: 54 (higher ratings optional)
Input Voltage: 12, 24 or 48 V
Output Voltage 110V model: 100/110/120 VAC
Output Voltage 220V model: 220/230/240 VAC
Output Frequency: 50 or 60 HZ
± 0.05% Accuracy
2KW Surge Rating: 4000W
3KW Surge Rating: 6000W
No load Current: <1.0W Sleep Mode
Output Waveform Sinewave: <3% THD
Output Regulation: -10% / +4% All models
MTBF: over 100,000 hours per field data
MTTR: 30 minutes
ENVIRONMENTAL
Operating Temperature: -20°C to +50°C
Storage Temperature: -40°C to + 71°C
Shock: 20g / 11mS per MIL-STD-810
Vibration: per MIL-STD-810 (Munson
Road Test)
Humidity: per MIL-STD-810 to 95% non
condensing
EMI: per MIL-STD-461 CE102, CS101,
CS114, CS115, CS116, RE102, and RS103
PROTECTIVE FEATURES
Overload, Short Circuit, Reverse Polarity
(Fuse), O.T, Over/Under Input Voltage.
MODEL SELECTION
CONTINUOUS
OUTPUT
INPUT RANGE OUTPUT
FREQ. (HZ) OUTPUT POWER
VDC
VDC
MODEL
SIZE (HxWxL)
APPROX.
EFFICIENCY
(INCHES)
(FULL LOAD) WEIGHT (LB)
OCGL2K-12-120
10.5-15
120
50 OR 60
2KW
89%
29 LB
6.8 x 10 x 17.9
OCGL2K-12-220
10.5-15
220
50 OR 60
2KW
91%
29 LB
6.8 x 10 x 17.9
OCGL2K-24-120
21-30
120
50 OR 60
2KW
92%
29 LB
6.8 x 10 x 17.9
OCGL3K-24-120
21-30
120
50 OR 60
3KW
91%
34 LB
9 x 12 x 17.9
OCGL2K-24-220
21-30
220
50 OR 60
2KW
94%
29 LB
6.8 x 10 x 17.9
OCGL3K-24-220
21-30
220
50 OR 60
3KW
93%
34 LB
9 x 12 x 17.9
6.8 x 10 x 17.9
OCGL2K-48-120
42-60
120
50 OR 60
2KW
93%
29 LB
OCGL3K-48-120
42-60
120
50 OR 60
3KW
92%
34 LB
9 x 12 x 17.9
OCGL2K-48-220
42-60
220
50 OR 60
2KW
95%
29 LB
6.8 x 10 x 17.9
OCGL3K-48-220
42-60
220
50 OR 60
3KW
94%
34 LB
9 x 12 x 17.9
MECHANICAL SPECIFICATIONS
TYPICAL 2KW OUTLINE
(OPTIONAL)
WEB : www.novaelectric.com
E-Mail : [email protected]
PHONE : (201) 385-0500 FAX : (201) 385-0702
NOVA ELECTRIC
A Division of
TECHNOLOGY DYNAMICS, INC.
100 School St., Bergenfield NJ 07621