Click on Series name for product info on aimtec.com Series AME1-AZ 1Watt | AC-DC Converter FEATURES: • • • • • Models Single output I/O Isolation 3000VAC Operating Temp: -40°C to +80°C Input: 90-305VAC, 47-440Hz, or 130-430 VDC Optional 90-528VAC, 47-440Hz, or 130-745 VDC Over load, Short Circuit Protection Input Voltage (VAC/Hz) Input Voltage (VDC) AME1-3.3SAZ AME1-5SAZ AME1-12SAZ AME1-15SAZ AME1-24SAZ 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 130-430 130-430 130-430 130-430 130-430 -40 to -40 to -40 to -40 to -40 to AME1-3.3SBAZ AME1-5SBAZ AME1-12SBAZ AME1-15SBAZ AME1-24SBAZ 90-528/47-440 90-528/47-440 90-528/47-440 90-528/47-440 90-528/47-440 130-745 130-745 130-745 130-745 130-745 -40 to -40 to -40 to -40 to -40 to Model Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Input Dissipation (No Load) Output Specifications Parameters Voltage accuracy Line regulation Load regulation (single output) Transient Recovery Time Transient Response Deviation Minimum load Ripple & Noise • RoHS compliant • Energy Star compliant • Ultra small package Output Voltage (V) Output Current max (mA) Maximum capacitive Load (µF) +80 +80 +80 +80 +80 3.3 5 12 15 24 300 200 83 67 42 +80 +80 +80 +80 +80 3.3 5 12 15 24 300 200 83 67 42 Temperature range (ºC) Conditions Typical 115 VAC 230 VAC 277 VAC 480VAC 115 VAC 230 VAC 277 VAC 480 VAC Efficiency (%) 115 230 277 480 VAC VAC VAC VAC 2200 1100 680 560 470 62 58 73 77 79 59 57 68 68 79 58 56 65 70 77 2200 1100 680 560 470 51 57 62 61 58 51 57 62 59 58 50 56 60 58 56 Maximum 25 20 15 5 10 15 20 30 0.15 Recommended slow blow type Conditions Typical ±5 ±1.5 ±5 200 ±2 0 200 400 500 25% load step 3.3/5 VDC With 560µF E/C 12/15 VDC With 220µF E/C 24 VDC With 220µF E/C Units mA mA mA mA A A A A mA A W 1 ≦0.3 Full load (typical)* LL-HL, Full Load 0-100% load (typical)* 44 50 51 50 48 Maximum Units % % % µs % of Vout % mV p-p mV p-p mV p-p *Ripple &Noise measured at 20MHz bandwidth with 0.1µF and 115/230/277/480 VAC (Typical input) with Full Load. Isolation Specifications Parameters Tested I/O voltage Isolation Resistance www.aimtec.com F 052e R8.I Conditions Typical 60 sec >1000 Tel: +1 514 620 2722 1 of 3 Rated Units 3000 VAC MΩ Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME1-AZ 1Watt | AC-DC Converter General Specifications Parameters Switching frequency Over Load protection Short circuit protection Operating temperature Storage temperature Maximum Case temperature Humidity Case material Weight Dimensions (L x W x H) Conditions Typical Maximum 100 >125% Auto recovery Auto recovery Without derating Units KHz o -40 to +80 -40 to +85 C C o C % RH o 100 Non condensing 20 ~ 95 Plastic resin + Fiberglass (flammability to UL 94V-0) 25 g 1.40 x 0.92 x 0.76 (35.60 x 23.31 x 19.32mm) > 400,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load MTBF > 100,000 hrs (MIL-HDBK -217F, t= at highest operating temperature)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Shock Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Vibrations Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals Standards cULus, CE, CB, FCC Information technology Equipment EMI - Conducted and radiated emission Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity(1KV) RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity IEC/EN/UL 60950-1:2006+A11:2009 EN55022, class B (* see note) IEC/EN 61000-3-2, Class A IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1) IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 FCC part 15 Subpart B, Class B, ANSI C63.4 :2003 * Note: for 528VAC models to meet the EN55022 class B spec an external 0.33uF X capacitor is needed to be installed between AC L and AC N as close as possible to the input of the power supply itself Pin Out Specifications* Pin Single 1* 2* 3 4 AC Input (N) or (L1) AC Input (L) or (L2) -V Output +V Output * Note: Input Pins 1 and 2 can be “N” and "L" respectively when the input voltage is supplied from a single phase. Input Pins 1 and 2 can be “L1” and "L2" respectively when the input voltage is supplied from 3 phase line to line voltage 208-480Vac (208 Y/ 120V 3-phase, 240 Y/ 120V 3-phase, 400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase). www.aimtec.com F 052e R8.I Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME1-AZ 1Watt | AC-DC Converter Dimensions 17.80 (0.70) 35.60 (1.40) Top Vi ew 1 15.24 1 3 Top View (0.60) 7.60 (0.29) 4 Temperaturem easuring point 11.655 3 (0.46) 23.31 4 (0.92) 2 2 28.00 DIV: 5.00(0.20) (1.10) Ø 10.0 ( Ø 0.40) Ø 0.60 ( Ø 0.02) 19.32 Side View (0.76) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter ±0.05 (±0.002) Pin Pitch Tolerance ±0.50 (±0.02) 6.00 (0.24) 0.60 (0.02) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.I Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only