Rohm EMH9FHA General purpose (dual digital transistors) Datasheet

EMH9 FHA
Datasheet
General purpose (Dual digital transistors)
AEC-Q101 Qualified
l Outline
Parameter
VCC
DTr1 and DTr2
SOT-563
50V
SC-107C
IC(MAX.)
100mA
R1
10kΩ
R2
47kΩ
EMT6
l Features
1)Two DTC114Y chips in a EMT6 package.
2)Mounting possible with EMT3 automatic
mounting machines.
3)Transistor elements are independent,
eliminating interference.
4)Mounting cost and area can be cut in half.
l Inner circuit
l Application
INVERTER, INTERFACE, DRIVER
l Packaging specifications
Part No.
Package
Package
size
Taping
code
EMH9 FHA
SOT-563
(EMT6)
1616
T2R
www.rohm.com
© 2016 ROHM Co., Ltd. All rights reserved.
1/5
Reel size Tape width
(mm)
(mm)
180
8
Basic
ordering
unit.(pcs)
Marking
8000
H9
20161012 - Rev.001
EMH9 FHA
Datasheet
l Absolute maximum ratings (Ta = 25°C)
<For DTr1 and DTr2 in common>
Parameter
Symbol
Values
Unit
Supply voltage
VCC
50
V
Input voltage
VIN
-6 to 40
V
Output current
IO
70
mA
Collector current
IC(MAX)*1
100
mA
Power dissipation
PD*2*3
150
Tj
150
℃
Tstg
-55 to +150
℃
Junction temperature
Range of storage temperature
mW/TOTAL
l Electrical characteristics (Ta = 25°C)
<For DTr1 and DTr2 in common>
Values
Parameter
Input voltage
Output voltage
Input current
Symbol
Conditions
Unit
Min.
Typ.
Max.
VI(off)
VCC = 5V, IO = 100μA
-
-
0.3
VI(on)
VO = 0.3V, IO = 1mA
1.4
-
-
VO(on)
IO = 5mA, II = 0.25mA
-
100
300
mV
VI = 5V
-
-
880
μA
II
V
Output current
IO(off)
VCC = 50V, VI = 0V
-
-
500
nA
DC current gain
GI
VO = 5V, IO = 5mA
68
-
-
-
Input resistance
R1
-
7
10
13
kΩ
Resistance ratio
R2/R1
-
3.7
4.7
5.7
-
-
250
-
MHz
Transition frequency
f T*1
VCE = 10V, IE = -5mA,
f = 100MHz
*1 Characteristics of built-in transistor
*2 Each terminal mounted on a reference land.
*3 120mW per element must not be exceeded.
www.rohm.com
© 2016 ROHM Co., Ltd. All rights reserved.
2/5
20161012 - Rev.001
EMH9 FHA
Datasheet
l Electrical characteristic curves (Ta = 25°C)
<For DTr1 and DTr2 in common>
Fig.1 Input Voltage vs. Output Current
(ON Characteristics)
Fig.2 Output Current vs. Input Voltage
(OFF Characteristics)
Fig.3 Output Current vs. Output Voltage
Fig.4 DC Current Gain vs. Output Current
www.rohm.com
© 2016 ROHM Co., Ltd. All rights reserved.
3/5
20161012 - Rev.001
EMH9 FHA
Datasheet
l Electrical characteristic curves (Ta = 25°C)
<For DTr1 and DTr2 in common>
Fig.5 Output Voltage vs. Output Current
www.rohm.com
© 2016 ROHM Co., Ltd. All rights reserved.
4/5
20161012 - Rev.001
EMH9 FHA
Datasheet
l Dimensions
www.rohm.com
© 2016 ROHM Co., Ltd. All rights reserved.
5/5
20161012 - Rev.001
Notice
Precaution on using ROHM Products
1.
(Note 1)
If you intend to use our Products in devices requiring extremely high reliability (such as medical equipment
,
aircraft/spacecraft, nuclear power controllers, etc.) and whose malfunction or failure may cause loss of human life,
bodily injury or serious damage to property (“Specific Applications”), please consult with the ROHM sales
representative in advance. Unless otherwise agreed in writing by ROHM in advance, ROHM shall not be in any way
responsible or liable for any damages, expenses or losses incurred by you or third parties arising from the use of any
ROHM’s Products for Specific Applications.
(Note1) Medical Equipment Classification of the Specific Applications
JAPAN
USA
EU
CHINA
CLASSⅢ
CLASSⅡb
CLASSⅢ
CLASSⅢ
CLASSⅣ
CLASSⅢ
2.
ROHM designs and manufactures its Products subject to strict quality control system. However, semiconductor
products can fail or malfunction at a certain rate. Please be sure to implement, at your own responsibilities, adequate
safety measures including but not limited to fail-safe design against the physical injury, damage to any property, which
a failure or malfunction of our Products may cause. The following are examples of safety measures:
[a] Installation of protection circuits or other protective devices to improve system safety
[b] Installation of redundant circuits to reduce the impact of single or multiple circuit failure
3.
Our Products are not designed under any special or extraordinary environments or conditions, as exemplified below.
Accordingly, ROHM shall not be in any way responsible or liable for any damages, expenses or losses arising from the
use of any ROHM’s Products under any special or extraordinary environments or conditions. If you intend to use our
Products under any special or extraordinary environments or conditions (as exemplified below), your independent
verification and confirmation of product performance, reliability, etc, prior to use, must be necessary:
[a] Use of our Products in any types of liquid, including water, oils, chemicals, and organic solvents
[b] Use of our Products outdoors or in places where the Products are exposed to direct sunlight or dust
[c] Use of our Products in places where the Products are exposed to sea wind or corrosive gases, including Cl2,
H2S, NH3, SO2, and NO2
[d] Use of our Products in places where the Products are exposed to static electricity or electromagnetic waves
[e] Use of our Products in proximity to heat-producing components, plastic cords, or other flammable items
[f] Sealing or coating our Products with resin or other coating materials
[g] Use of our Products without cleaning residue of flux (even if you use no-clean type fluxes, cleaning residue of
flux is recommended); or Washing our Products by using water or water-soluble cleaning agents for cleaning
residue after soldering
[h] Use of the Products in places subject to dew condensation
4.
The Products are not subject to radiation-proof design.
5.
Please verify and confirm characteristics of the final or mounted products in using the Products.
6.
In particular, if a transient load (a large amount of load applied in a short period of time, such as pulse. is applied,
confirmation of performance characteristics after on-board mounting is strongly recommended. Avoid applying power
exceeding normal rated power; exceeding the power rating under steady-state loading condition may negatively affect
product performance and reliability.
7.
De-rate Power Dissipation depending on ambient temperature. When used in sealed area, confirm that it is the use in
the range that does not exceed the maximum junction temperature.
8.
Confirm that operation temperature is within the specified range described in the product specification.
9.
ROHM shall not be in any way responsible or liable for failure induced under deviant condition from what is defined in
this document.
Precaution for Mounting / Circuit board design
1.
When a highly active halogenous (chlorine, bromine, etc.) flux is used, the residue of flux may negatively affect product
performance and reliability.
2.
In principle, the reflow soldering method must be used on a surface-mount products, the flow soldering method must
be used on a through hole mount products. If the flow soldering method is preferred on a surface-mount products,
please consult with the ROHM representative in advance.
For details, please refer to ROHM Mounting specification
Notice-PAA-E
© 2015 ROHM Co., Ltd. All rights reserved.
Rev.003
Precautions Regarding Application Examples and External Circuits
1.
If change is made to the constant of an external circuit, please allow a sufficient margin considering variations of the
characteristics of the Products and external components, including transient characteristics, as well as static
characteristics.
2.
You agree that application notes, reference designs, and associated data and information contained in this document
are presented only as guidance for Products use. Therefore, in case you use such information, you are solely
responsible for it and you must exercise your own independent verification and judgment in the use of such information
contained in this document. ROHM shall not be in any way responsible or liable for any damages, expenses or losses
incurred by you or third parties arising from the use of such information.
Precaution for Electrostatic
This Product is electrostatic sensitive product, which may be damaged due to electrostatic discharge. Please take proper
caution in your manufacturing process and storage so that voltage exceeding the Products maximum rating will not be
applied to Products. Please take special care under dry condition (e.g. Grounding of human body / equipment / solder iron,
isolation from charged objects, setting of Ionizer, friction prevention and temperature / humidity control).
Precaution for Storage / Transportation
1.
Product performance and soldered connections may deteriorate if the Products are stored in the places where:
[a] the Products are exposed to sea winds or corrosive gases, including Cl2, H2S, NH3, SO2, and NO2
[b] the temperature or humidity exceeds those recommended by ROHM
[c] the Products are exposed to direct sunshine or condensation
[d] the Products are exposed to high Electrostatic
2.
Even under ROHM recommended storage condition, solderability of products out of recommended storage time period
may be degraded. It is strongly recommended to confirm solderability before using Products of which storage time is
exceeding the recommended storage time period.
3.
Store / transport cartons in the correct direction, which is indicated on a carton with a symbol. Otherwise bent leads
may occur due to excessive stress applied when dropping of a carton.
4.
Use Products within the specified time after opening a humidity barrier bag. Baking is required before using Products of
which storage time is exceeding the recommended storage time period.
Precaution for Product Label
A two-dimensional barcode printed on ROHM Products label is for ROHM’s internal use only.
Precaution for Disposition
When disposing Products please dispose them properly using an authorized industry waste company.
Precaution for Foreign Exchange and Foreign Trade act
Since concerned goods might be fallen under listed items of export control prescribed by Foreign exchange and Foreign
trade act, please consult with ROHM in case of export.
Precaution Regarding Intellectual Property Rights
1.
All information and data including but not limited to application example contained in this document is for reference
only. ROHM does not warrant that foregoing information or data will not infringe any intellectual property rights or any
other rights of any third party regarding such information or data.
2.
ROHM shall not have any obligations where the claims, actions or demands arising from the combination of the
Products with other articles such as components, circuits, systems or external equipment (including software).
3.
No license, expressly or implied, is granted hereby under any intellectual property rights or other rights of ROHM or any
third parties with respect to the Products or the information contained in this document. Provided, however, that ROHM
will not assert its intellectual property rights or other rights against you or your customers to the extent necessary to
manufacture or sell products containing the Products, subject to the terms and conditions herein.
Other Precaution
1.
This document may not be reprinted or reproduced, in whole or in part, without prior written consent of ROHM.
2.
The Products may not be disassembled, converted, modified, reproduced or otherwise changed without prior written
consent of ROHM.
3.
In no event shall you use in any way whatsoever the Products and the related technical information contained in the
Products or this document for any military purposes, including but not limited to, the development of mass-destruction
weapons.
4.
The proper names of companies or products described in this document are trademarks or registered trademarks of
ROHM, its affiliated companies or third parties.
Notice-PAA-E
© 2015 ROHM Co., Ltd. All rights reserved.
Rev.003
Datasheet
EMH9FHA - Web Page
Part Number
Package
Unit Quantity
Minimum Package Quantity
Packing Type
Constitution Materials List
RoHS
EMH9FHA
EMT6
8000
8000
Taping
inquiry
Yes
Similar pages