FEATURES
►SMD Package with Industry Standard Pinout
►Package Dimension:
15.3 x 8.0 x 7.1 mm (0.6”x 0.31”x 0.28”)
►High I/O-Isolation 3000 VDC
►Operating Temp. Range –40° to +85°C
►High Accuracy of Pin Planarity
►Qualified for lead-free reflow solder process according
IPC/JEDEC J-STD-020D
►Tape & Reel Package available
►3 Year Product Warranty
PRODUCT OVERVIEW
The MSAU300 series is a range of 1W DC/DC converters in a SMD- Package featuring high I/O-isolation of 3000VDC.The small footprint makes this
product the ideal solution for many applications where a voltage has to be isolated i.e for noise reduction, ground loop elimination, in digital interfaces or
where a higher I/O isolation is required.
An excellent efficiency allows an operating temperature range of–40°C to +85°C. These converters are fully qualified for the higher temperature profile
used in lead-free reflow solder processes. For automated SMD production lines the product can also be supplied in tape& reel package.
Model Selection Guide
Model
Input
Output
Number
Voltage
Voltage
(Range)
VDC
MSAU301
MSAU303
MSAU304
MSAU306
MSAU308
MSAU309
MSAU311
MSAU313
MSAU314
MSAU316
MSAU318
MSAU319
MSAU321
MSAU323
MSAU324
MSAU326
MSAU328
MSAU329
5
(4.5 ~ 5.5)
12
(10.8 ~ 13.2)
24
(21.6 ~ 26.4)
VDC
5
12
15
±5
±12
±15
5
12
15
±5
±12
±15
5
12
15
±5
±12
±15
Output Current
Input Current
Max.
Min.
@Max. Load
@No Load
mA
200
84
67
±100
±42
±34
200
84
67
±100
±42
±34
200
84
67
±100
±42
±34
mA
4
1.5
1
±2
±0.8
±0.7
4
1.5
1
±2
±0.8
±0.7
4
1.5
1
±2
±0.8
±0.7
mA(typ.)
281
258
258
277
255
258
117
106
104
112
105
104
58
53
53
57
53
53
mA(typ.)
Load
Max. capacitive
Regulation
Load
Efficiency
(typ.)
@Max. Load
% (max.)
10
7
7
10
7
7
8
5
5
8
5
5
8
5
5
8
5
5
30
12
7
uF
33
4.7
4.7
10#
2.2#
2.2#
33
4.7
4.7
10#
2.2#
2.2#
33
4.7
4.7
10#
2.2#
2.2#
# For each output
%
71
78
78
72
78
79
71
79
80
74
80
81
71
78
79
72
79
80
Input Specifications
Parameter
Input Voltage Range
Input Surge Voltage (1 sec. max.)
Model
Min.
Typ.
Max.
5V Input Models
4.5
5
5.5
12V Input Models
10.8
12
13.2
24V Input Models
21.6
24
26.4
5V Input Models
-0.7
---
9
12V Input Models
-0.7
---
18
24V Input Models
-0.7
---
30
---
---
0.3
Reverse Polarity Input Current
Input Filter
Internal Power Dissipation
In
Total Power International,
Inc
All Models
Unit
VDC
A
Internal Capacitor
---
Toll Free: 877-646-0900
---
550
www.total-power.com
mW
MSAU300 SERIES
Tota
Total Power International, Inc.
DC/DC CONVERTER 1W, SMD-Package, High Isolation
Output Specifications
Parameter
Conditions
Min.
Typ.
Max.
---
±1.5
±4.0
%
Dual Output, Balanced Loads
---
±0.1
±1.0
%
Line Regulation
For Vin Change of 1%
---
±1.2
±1.5
%
Load Regulation
Io=20% to 100%
Output Voltage Accuracy
Output Voltage Balance
See Model Selection Guide
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Unit
Over Line, Load & Temp.
---
75
100
mV P-P
---
---
150
mV P-P
Ripple & Noise (20MHz)
---
---
15
mV rms
Temperature Coefficient
---
±0.01
±0.02
%/℃
Short Circuit Protection
0.5 Second Max.
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
3000
---
---
VDC
I/O Isolation Resistance
500 VDC
10
---
---
GΩ
I/O Isolation Capacitance
100KHz, 1V
I/O Isolation Voltage (rated)
Switching Frequency
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
Moisture Sensitivity Level (MSL)
---
60
100
pF
50
100
150
KHz
2,000,000
---
---
Hours
IPC/JEDEC J-STD-020D
Level 3
Input Fuse
5V Input Models
500mA Slow-Blow Type
12V Input Models
200mA Slow-Blow Type
24V Input Models
100mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Ambient
Min.
-40
---50
--Free-Air convection
---
Max.
+85
+90
+125
95
Unit
℃
℃
℃
% rel. H
300
℃
Power Derating Curve
100
Natural
convection
80
100LFM
200LFM
60
400LFM
40
20
0
~
-40
0
20
40
60
80
100 110
Ambient Temperature ]
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Ripple & Noise measurement bandwidth is 0-20MHz.
3
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
4
All DC/DC converters should be externally fused at the front end for protection.
5
Other input and output voltage may be available, please contact factory.
6
Specifications subject to change without notice.
modules; however they may not meet all specifications listed.
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
MSAU300 SERIES
Tota
Total Power International, Inc.
DC/DC CONVERTER 1W, SMD-Package, High Isolation
Package Specifications
8
7
1
5
6
3
5.08
[0.2]
2.54
[0.1]
2.54 [0.10]
1.7 [0.07]
10.8 [0.43]
0~
5.08
[0.2]
R
1.3
[0.05]
12.7 [0.50]
4
0.
5
2
11.2 [0.44]
12 11 10
0.25 [0.01]
Connecting Pin Patterns
8.0 [0.31]
Mechanical Dimensions
( Magnification of A )
15.3 [0.6]
6.75
[0.27]
7.0 0.5
[0.28 0.02]
1.0 [0.04]
S SEATING PLANE
A
7.0 [0.28]
0.25
[0.01]
0.60 [0.02]
5.08 [0.20]
9.2 [0.36]
0.15 S
►All dimensions in mm (inches)
►Tolerance: X.X±0.25 (X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pins ±0.05 (±0.002)
Pin Connections
Physical Characteristics
Pin
Single Output
Dual Output
1
-Vin
-Vin
2
+Vin
+Vin
3
NA
NA
5
-Vout
Common
6
NA
-Vout
7
NA
NA
8
+Vout
+Vout
10
NA
NA
11
NA
NA
12
NA
NA
Case Size
:
15.3x8.0x6.75mm (0.60x0.31x0.27 Inches)
Case Material
:
Molding (flammability to UL 94V-0 rated)
Weight
:
2.2g
NA : Not Available for Electrical Connection
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
Tota
Total Power International, Inc.
MSAU300 SERIES
DC/DC CONVERTER 1W, SMD-Package, High Isolation
Test Configurations
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets
possible battery impedance.
Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
Battery
+Vin
Lin
DC / DC
Converter
Current
Probe
Cin
+Out
-Vin
Load
-Out
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
Design & Feature Considerations
Maximum Capacitive Load
The MSAU300 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 2.2uF for the 5V input devices, a 1.0uF for the 12V input devices and a 0.47uF for the 24V devices..
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 1.0uF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
Cout
Load
-Out
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
50mm / 2in
15mm / 0.6in
In
Total Power International,
Inc
Air Flow
DUT
Toll Free: 877-646-0900
www.total-power.com
Similar pages