[ Obsolete product ] Agilent has a new name Keysight Technologies. Keysight Technologies Inc. is the world's leading electronic measurement company, transforming today's measurement experience through innovations in wireless, modular, and software solutions. With its HP and Agilent legacy, Keysight delivers solutions in wireless communications, aerospace and defense and semiconductor markets with world-class platforms, software and consistent measurement science. Alldatasheet.com Agilent PSA Series Spectrum Analyzers Data Sheet 40/80 MHz Analysis Bandwidth Now Available On 50 GHz PSA! The Agilent PSA Series offers highperformance spectrum analysis, up to 50 GHz, with powerful one-button measurements, a versatile feature set, and a leading-edge combination of flexibility, speed, accuracy, analysis bandwidth, and dynamic range. From millimeter wave and phase noise measurements to spur searches and modulation analysis, the PSA Series offers unique and comprehensive high-performance solutions to R&D and manufacturing engineers in cellular and emerging wireless communications, aerospace, and defense. For more information regarding the PSA wide analysis bandwidth, see the 40/80 MHz BW digitizers, Option 140/122, technical overview at www.agilent.com/find/ps Models E4443A 3 Hz to 6.7 GHz E4445A 3 Hz to 13.2 GHz E4440A 3 Hz to 26.5 GHz* E4447A 3 Hz to 42.98 GHz E4446A 3 Hz to 44 GHz* E4448A 3 Hz to 50 GHz* * 325 GHz with external mixing Table of Contents Definitions and Conditions . . . . . . 3 Frequency Specifications . . . . . . . 4 Frequency range . . . . . . . . . . . . . . . . 4 Frequency reference . . . . . . . . . . . . . 4 Frequency readout accuracy . . . . . . 4 Marker frequency counter . . . . . . . . 4 Frequency span . . . . . . . . . . . . . . . . . 4 Sweep time and triggering . . . . . . . . 5 Sweep (trace) point range . . . . . . . . 5 Gated sweep . . . . . . . . . . . . . . . . . . . 5 Gated FFT . . . . . . . . . . . . . . . . . . . . . 5 Resolution bandwidth (RBW) . . . . . 5 Analysis bandwidth . . . . . . . . . . . . . 6 Video bandwidth (VBW) . . . . . . . . . . 6 Stability . . . . . . . . . . . . . . . . . . . . . . . 6 Amplitude Specifications . . . . . . . 7 Amplitude range . . . . . . . . . . . . . . . . 7 Maximum safe input level . . . . . . . . 7 1 dB gain compression (two tone) . 7 Typical gain compression (two tone) . . 7 Displayed average noise level (DANL) . . 8 Display range . . . . . . . . . . . . . . . . . 10 Frequency response . . . . . . . . . . . . 10 Input attenuation switching uncertainty . . . . . . . . . . . . . . . . . . . 10 Total absolute amplitude accuracy 10 Input voltage standing wave ratio (VSWR) . . . . . . . . . . . . . . . . . . . . . . 11 Resolution bandwidth switching uncertainty . . . . . . . . . . . . . . . . . . . 11 Reference level . . . . . . . . . . . . . . . . 11 Display scale switching uncertainty . . .11 Display scale fidelity . . . . . . . . . . . . 11 Spurious response . . . . . . . . . . . . . 11 Second harmonic distortion (SHI) . .12 Third-order intermodulation distortion (TOI) . . . . . . . . . . . . . . . . 12 Residual responses . . . . . . . . . . . . . 14 Trace detectors . . . . . . . . . . . . . . . . 14 EMI detectors . . . . . . . . . . . . . . . . . 14 Option E444xA-1DS, preamplifier . . .14 Option E444xA-110, preamplifier . . 14 Measurement speed . . . . . . . . . . . . 14 Option AYZ, external mixing . . . . . . 15 Option 123, preselector bypass . . . . 15 Power Suite Measurement Specifications. . . . . . . . . . . . . . . . 16 Channel power . . . . . . . . . . . . . . . . 16 Occupied bandwidth . . . . . . . . . . . . 16 Adjacent channel power . . . . . . . . 16 Multi-carrier power and ACP . . . . . 16 Power statistics CCDF . . . . . . . . . . 16 Harmonic distortion . . . . . . . . . . . . 16 Intermod (TOI) . . . . . . . . . . . . . . . . . 16 Burst power . . . . . . . . . . . . . . . . . . . 16 Spurious emission . . . . . . . . . . . . . 17 Spectrum emission mask (SEM) . . 17 General Specifications. . . . . . . . . 18 Temperature range . . . . . . . . . . . . . 18 EMI compatibility . . . . . . . . . . . . . . 18 Audio noise . . . . . . . . . . . . . . . . . . . 18 Military specification . . . . . . . . . . . 18 Power requirements . . . . . . . . . . . . 18 Weight . . . . . . . . . . . . . . . . . . . . . . . 18 Dimensions . . . . . . . . . . . . . . . . . . . 18 Warranty . . . . . . . . . . . . . . . . . . . . . 18 Calibration cycle . . . . . . . . . . . . . . . 18 Input and Outputs. . . . . . . . . . . . . 19 Front panel . . . . . . . . . . . . . . . . . . . 19 Rear panel . . . . . . . . . . . . . . . . . . . . 19 PSA Series Ordering Information 21 PSA Series spectrum analyzer . . . . 21 Options . . . . . . . . . . . . . . . . . . . . . . 21 Related Literature . . . . . . . . . . . . 23 Support, Services, and Assistance . . . . . . . . . . . . . . . . . . 24 2 Definitions and Conditions Specifications describe the performance of parameters covered by the product warranty and apply over 0 to 55 °C unless otherwise noted. Typical describes additional product performance information that is not covered by the product warranty. It is performance beyond specifications that 80 percent of the units exhibit with a 95 percent confidence level over the temperature range 20 to 30 °C. Typical performance does not include measurement uncertainty. Nominal values indicate expected performance, or describe product performance that is useful in the application of the product, but is not covered by the product warranty. The analyzer will meet its specifications when: • stored a minimum of two hours within the operating temperature range and turned on for at least 30 minutes with Auto Align On selected. • the instrument is within its one year calibration cycle. • Align All Now has been performed within the past 24 hours or when the temperature changes 3 °C. • the instrument is under auto couple control, except that Auto Sweep Time = Accy. • DC coupling applied if center frequency is < 20 MHz. 3 This PSA Series data sheet is a summary of the complete specifications and conditions, which are available in the PSA Series Spectrum Analyzers Specification Guide. The PSA Series Spectrum Analyzers Specification Guide can be obtained on the web through: www.agilent.com/find/psa Then follow this selection process: • Select “Technical Support” under Key Library Information • Select “Manuals and Guides” • Download specifications guide. Frequency Specifications Frequency range E4443A E4445A E4440A E4447A E4446A E4448A (DC coupled) (DC coupled) (DC coupled) (DC coupled) (DC coupled) (DC coupled) 3 Hz to 6.7 GHz 3 Hz to 13.2 GHz 3 Hz to 26.5 GHz1 3 Hz to 42.98 GHz 3 Hz to 44 GHz1 3 Hz to 50 GHz1 (AC coupled) (AC coupled) (AC coupled) 20 MHz to 6.7 GHz 20 MHz to 13.2 GHz 20 MHz to 26.5 GHz1 1. 325 GHz with external mixers Band Harmonic mixing mode (N) 0 1 2 3 4 5 6 1– 1– 2– 4– 4– 4+ 8– 3 Hz to 3 GHz 2.85 GHz to 6.6 GHz 6.2 GHz to 13.2 GHz 12.8 GHz to 19.2 GHz 18.7 GHz to 26.8 GHz 26.4 GHz to 31.15 GHz 31.0 GHz to 50.0 GHz Frequency reference Accuracy Aging rate Temperature stability Achievable initial calibration accuracy Example frequency reference accuracy 1 year after last adjustment ±[(time since last adjustment x aging rate) + temperature stability + calibration accuracy] ± 1 x 10–7 / year 0 °C to 55 °C ±5 x 10–8 20 °C to 30 °C ±1 x 10–8 ±7 x 10–8 = ±(1 x 1 x 10–7 + 1 x 10–8 + 7 x 10–8) = ±1.8 x 10–7 Frequency readout accuracy (start, stop, center, marker) ± (marker frequency x frequency reference accuracy + 0.25% x span + 5% x RBW + 2 Hz + 0.5 x horizontal resolution*) * Horizontal resolution is span/(sweep points – 1) Marker frequency counter Accuracy Delta counter accuracy Counter resolution ±(marker frequency x frequency reference accuracy + 0.100 Hz) ±(delta frequency x frequency reference accuracy + 0.141 Hz) 0.001 Hz Frequency span (FFT and swept mode) Range Resolution 0 Hz (zero span), 10 Hz to maximum frequency of model 2 Hz Accuracy ±[0.2% x span + span / (sweep points – 1)] 4 Frequency Specifications (continued) Sweep time and triggering Range Accuracy Trigger Trigger delay Span = 0 Hz Span ≥ 10 Hz Span ≥ 10 Hz, sweep Span ≥ 10 Hz, FFT Span = 0 Hz Free run, line, video, RF burst, external front, external rear, frame (basic mode) Span = 0 Hz, or FFT Span ≥ 10 Hz, swept Resolution 1 µs to 6000 s 1 ms to 2000 s ±0.01% nominal ±40% nominal ±0.01% nominal –150 ms to +500 ms 1 µs to 500 ms 0.1 µs Sweep (trace) point range Span = 0 Hz Span ≥ 10 Hz 2 to 8192 101 to 8192 Gated sweep Gate length Gate delay range Gate delay jitter 10 µs to 500 ms 0 to 500 ms 33.3 ns p-p nominal Gated FFT Delay range Delay resolution Gate duration –150 to +500 ms 100 ns or 4 digits whichever is more 1.83/RBW ± 2% nominal Resolution bandwidth (RBW) Range (–3.01 dB bandwidth) Bandwidth accuracy (power) RBW range Bandwidth accuracy (–3.01 dB) RBW range Selectivity (–60 dB/–3 dB) EMI bandwidths (CISPR compliant) EMI bandwidths (MIL STD 461E compliant) 1 Hz to 3 MHz (10% steps), 4, 5, 6, 8 MHz 1 Hz to 51 kHz 56 kHz to 75 kHz 82 kHz to 330 kHz 360 kHz to 1.1 MHz (< 3 GHz CF) 1.2 MHz to 2.0 MHz (< 3 GHz CF) 2.2 MHz to 6.0 MHz (< 3 GHz CF) 1 Hz to 1.5 MHz 4.1:1 nominal 200 Hz, 9 kHz, 120 kHz, 1 MHz 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz 5 ±0.5% (± 0.022 dB) ±1.0% (± 0.044 dB) ±0.5% (± 0.022 dB) ±1.0% (± 0.044 dB) ±0.07 dB nominal ±0.2 dB nominal ±2% nominal Frequency Specifications (continued) Analysis bandwidth 1 Maximum bandwidth with Option 140 2 with Option 122 2 with Option B7J 40 MHz 80 MHz 10 MHz 1. Analysis bandwidth is the instantaneous bandwidth available around a center frequency over which the input signal can be digitized for further analysis or processing in the time, frequency, or modulation domain. 2. Not available for E4447A. Video bandwidth (VBW) Range Accuracy 1 Hz to 3 MHz (10% steps), 4, 5, 6, 8 MHz and wide open ±6% nominal Stability3 Offset Noise sidebands (20 °C to 30 °C, CF = 1 GHz) Specification Typical 100 Hz –91 dBc/Hz –96 dBc/Hz 1 kHz –103 dBc/Hz –108 dBc/Hz 10 kHz –116 dBc/Hz –118 dBc/Hz 30 kHz –116 dBc/Hz –118 dBc/Hz 100 kHz –122 dBc/Hz –124 dBc/Hz 1 MHz –145 dBc/Hz –147 dBc/Hz, –148 dBc/Hz nominal 6 MHz –154 dBc/Hz –156 dBc/Hz, –156.5 dBc/Hz nominal 10 MHz –156 dBc/Hz –157.5 dBc/Hz, –158 dBc/Hz nominal < (1 Hz X N) p-p in 1 s, typical, see frequency range for N (harmonic number) Residual FM 3. For nominal values, refer to Figure 1. SSB Phase Noise (dBc/Hz) Nominal Phase Noise at Common Cellular Communication Frequencies, £ (f) Optimized versus f –70 –80 –90 –100 –110 –120 –130 –140 –150 –160 –170 2 GHz 1 GHz 0.1 1 10 100 1000 Offset Frequency (kHz) Figure 1. Nominal phase noise at common cellular frequencies 6 10000 Amplitude Specifications Amplitude range Measurement range Input attenuator range (3 Hz to 50 GHz) Displayed average noise level (DANL) to maximum safe input level 0 to 70 dB in 2 dB steps Maximum safe input level Average total power Preamp (Option E444xA-1DS) Preamp (Option E444xA-110) Peak pulse power DC volts +30 dBm (1 W) +30 dBm +23 dBm < 10 µs pulse width, < 1% duty cycle and input attenuation ≥ 30 dB +50 dBm (100 W) DC coupled < ±0.2 Vdc AC coupled (E4443A, E4445A, E4440A only) ±100 Vdc 1 dB gain compression (two-tone) Preamp on (Option E444xA-1DS) Preamp on (Option E444xA-110) 20 MHz to 200 MHz 200 MHz to 3 GHz 3 GHz to 6.6 GHz 6.6 GHz to 26.5 GHz 26.5 GHz to 50 GHz 10 MHz to 200 MHz 200 MHz to 3 GHz 10 MHz to 200 MHz 200 MHz to 3 GHz 3.0 GHz to 6.6 GHz 6.6 GHz to 30 GHz 30 GHz to 50 GHz Total power at input mixer 0 dBm +3 dBm nominal +3 dBm +7 dBm nominal +3 dBm +4 dBm nominal –2 dBm 0 dBm nominal 0 dBm nominal –30 dBm nominal –25 dBm nominal –24 dBm nominal –20 dBm nominal –23 dBm nominal –27 dBm nominal –24 dBm nominal 20 MHz to 200 MHz 200 MHz to 6.6 GHz 6.6 GHz to 26.5 GHz Mixer level 0 dBm +3 dBm –2 dBm Typical gain compression (two-tone) 7 Compression < 0.5 dB < 0.5 dB < 0.4 dB Amplitude Specifications (continued) Displayed average noise level (DANL) (Input terminated, sample or average detector, averaging type = Log, 20 to 30 °C) E4443A/E4445A/E4440A Preamp ON (Option 1DS) Preamp ON (Option 110) 3 Hz to 1 kHz 1 kHz to 10 kHz 10 kHz to 100 kHz 100 kHz to 1 MHz 1 MHz to 10 MHz 10 MHz to 1.2 GHz 1.2 GHz to 2.1 GHz 2.1 GHz to 3.0 GHz 3 GHz to 6.6 GHz 6.6 GHz to 13.2 GHz 13.2 GHz to 20 GHz 20 GHz to 26.5 GHz 100 kHz to 200 kHz 200 kHz to 500 kHz 500 kHz to 1 MHz 1 MHz to 10 MHz 10 MHz to 500 MHz 500 MHz to 1.1 GHz 1.1 GHz to 2.1 GHz 2.1 GHz to 3.0 GHz 10 to 50 MHz 50 to 500 MHz 500 MHz to 2.1 GHz 2.1 to 3 GHz 3 to 6.6 GHz 6.6 to 13.2 GHz 13.2 to 16 GHz 16 to 19 GHz 19 to 26.5 GHz Zero span and swept normalized to 1 Hz RBW and 0 dB attenuation — — –137 dBm –145 dBm –150 dBm –154 dBm –153 dBm –152 dBm –152 dBm –150 dBm –147 dBm –143 dBm –159 dBm –159 dBm –163 dBm –166 dBm –169 dBm –168 dBm –167 dBm –165 dBm –148 dBm –153 dBm –166 dBm –166 dBm –165 dBm –163 dBm –162 dBm –162 dBm –159 dBm 8 Zero span and swept normalized to 1 Hz RBW 0 dB attenuation (typical) –110 dBm nominal –130 dBm nominal –141 dBm –149 dBm –153 dBm –155 dBm –154 dBm –153 dBm –153 dBm –152 dBm –149 dBm –145 dBm –162 dBm –162 dBm –165 dBm –168 dBm –170 dBm –169 dBm –168 dBm –166 dBm –154 dBm –164 dBm –168 dBm –168 dBm –166 dBm –165 dBm –165 dBm –164 dBm –161 dBm FFT only actual 1 Hz RBW 0 dB attenuation — — –137 dBm –145 dBm –150 dBm –154 dBm –153 dBm –152 dBm –151 dBm –149 dBm –146 dBm –143 dBm –158 dBm –158 dBm –162 dBm –165 dBm –168 dBm –167 dBm –166 dBm –165 dBm –148 dBm –153 dBm –166 dBm –166 dBm –165 dBm –163 dBm –162 dBm –162 dBm –159 dBm Amplitude Specifications (continued) Displayed average noise level (DANL) (Input terminated, sample or average detector, averaging type = Log, 20 to 30 °C) continued E4447A/E4446A/E4448A Preamp ON (Option 1DS) Preamp ON (Option 110) 3 Hz to 1 kHz 1 kHz to 10 kHz 10 kHz to 100 kHz 100 kHz to 1 MHz 1 MHz to 10 MHz 10 MHz to 1.2 GHz 1.2 GHz to 2.1 GHz 2.1 GHz to 3 GHz 3 GHz to 6.6 GHz 6.6 GHz to 13.2 GHz 13.2 GHz to 20 GHz 20 GHz to 22.5 GHz 22.5 GHz to 26.8 GHz 26.8 GHz to 31.15 GHz 31.15 GHz to 35 GHz 35 GHz to 38 GHz 38 GHz to 44 GHz 44 GHz to 49 GHz 49 GHz to 50 GHz 100 kHz to 200 kHz 200 kHz to 500 kHz 500 kHz to 1 MHz 1 MHz to 10 MHz 10 MHz to 500 MHz 500 MHz to 1.2 GHz 1.2 GHz to 2.1 GHz 2.1 GHz to 3.0 GHz 10 to 50 MHz 50 to 500 MHz 500 MHz to 1.2 GHz 1.2 to 2.1 GHz 2.1 to 3 GHz 3 to 6.6 GHz 6.6 to 13.2 GHz 13.2 to 19 GHz 19 to 22.5 GHz 22.5 to 26.8 GHz 26.8 to 31.15 GHz 31.15 to 35 GHz 35 to 38 GHz 38 to 41 GHz 41 to 44 GHz 44 to 45 GHz 45 to 49 GHz 49 to 50 GHz Zero span and swept normalized to 1 Hz RBW and 0 dB attenuation — — –137 dBm –145 dBm –150 dBm –153 dBm –152 dBm –151 dBm –151 dBm –146 dBm –144 dBm –143 dBm –140 dBm –142 dBm –134 dBm –129 dBm –131 dBm –128 dBm –127 dBm –158 dBm –158 dBm –161 dBm –167 dBm –167 dBm –166 dBm –165 dBm –163 dBm –148 dBm –153 dBm –165 dBm –165 dBm –165 dBm –165 dBm –162 dBm –161 dBm –161 dBm –155 dBm –157 dBm –152 dBm –146 dBm –146 dBm –146 dBm –143 dBm –143 dBm –140 dBm 9 Zero span and swept normalized to 1 Hz RBW and 0 dB attenuation (typical) –110 dBm nominal –130 dBm nominal –141 dBm –150 dBm –155 dBm –154 dBm –153 dBm –152 dBm –152 dBm –149 dBm –146 dBm –146 dBm –144 dBm –145 dBm –136 dBm –132 dBm –134 dBm –131 dBm –130 dBm –162 dBm –162 dBm –165 dBm –169 dBm –169 dBm –168 dBm –167 dBm –165 dBm –158 dBm –164 dBm –168 dBm –168 dBm –167 dBm –167 dBm –165 dBm –163 dBm –162 dBm –160 dBm –161 dBm –156 dBm –150 dBm –150 dBm –150 dBm –150 dBm –146 dBm –145 dBm FFT only actual 1 Hz RBW 0 dB attenuation — — –137 dBm –145 dBm –150 dBm –152 dBm –151 dBm –150 dBm –150 dBm –146 dBm –143 dBm –143 dBm –140 dBm –141 dBm –133 dBm –129 dBm –131 dBm –127 dBm –126 dBm –157 dBm –157 dBm –160 dBm –166 dBm –167 dBm –166 dBm –165 dBm –163 dBm –148 dBm –153 dBm –165 dBm –165 dBm –165 dBm –165 dBm –162 dBm –161 dBm –161 dBm –155 dBm –157 dBm –152 dBm –146 dBm –146 dBm –146 dBm –143 dBm –143 dBm –140 dBm Amplitude Specifications (continued) Display range Log scale Linear scale Scale units 0.1 to 1 dB/division in 0.1 dB steps 1 to 20 dB/division in 1 dB steps (10 display divisions) 10 divisions dBm, dBmV, dBµV, dBmA, dBµA, V, W, A, dBµV/m, dBµA/m, dBpT, dBG Frequency response (10 dB input attenuation, 20 to 30 °C, preselector centering applied above 3 GHz) E4443A/E4445A/E4440A E4447A/E4446A/E4448A Frequency response at attenuation ≠ 10 dB (Atten = 20, 30, or 40 dB) Preamp on (Option E444xA-1DS), (for all models) Preamp on (Option E444xA-110, 0 dB input attenuation) E4443A/E4445A/E4440A E4447A/E4446A/E4448A 3 Hz to 3 GHz 3 GHz to 6.6 GHz 6.6 GHz to 22 GHz 22 GHz to 26.5 GHz 3 Hz to 3 GHz 3 GHz to 6.6 GHz 6.6 GHz to 22 GHz 22 GHz to 26.8 GHz 26.4 GHz to 31.15 GHz 31.15 GHz to 50 GHz 10 MHz to 2.2 GHz 2.2 GHz to 3 GHz 100 kHz to 3 GHz ±0.38 dB ±1.50 dB ±2.00 dB ±2.50 dB ±0.38 dB ±1.50 dB ±2.00 dB ±2.50 dB ±1.75 dB ±2.50 dB ±0.53 dB ±0.69 dB ±0.70 dB (±0.11 dB typical) (±0.6 dB typical) (±1.0 dB typical) (±1.3 dB typical) (±0.15 dB typical) (±0.6 dB typical) (±1.2 dB typical) (±1.3 dB typical) (±0.6 dB typical) (±1.0 dB typical) 10 MHz to 3.0 GHz 3.0 to 6.6 GHz 6.6 to 13.2 GHz 13.2 to 19 GHz 19 to 26.5 GHz 10 MHz to 3.05 GHz 3.0 to 6.6 GHz 6.6 to 13.2 GHz 13.2 to 19 GHz 19 to 26.5 GHz 26.5 to 31.15 GHz 31.15 to 50 GHz ±1.0 dB ±1.75 dB ±3.0 dB ±3.0 dB ±4.0 dB ±1.3 dB ±2.5 dB ±2.5 dB ±3.0 dB ±4.0 dB ±3.0 dB ±3.5 dB (±0.35 dB typical) (±0.8 dB typical) (±1.0 dB typical) (±1.2 dB typical) (±2.0 dB typical) (±0.5 dB typical) (±1.0 dB typical) (±1.2 dB typical) (±1.5 dB typical) (±2.0 dB typical) (±1.2 dB typical) (±1.6 dB typical) ±0.18 dB ±0.053 dB typical ±0.3 dB nominal ±0.5 dB nominal ±0.7 dB nominal ±1.0 dB nominal < (±0.30 dB typical) Input attenuation switching uncertainty (Attenuator setting ≥ 2 dB) At 50 MHz 3 Hz to 3 GHz 3 GHz to 13.2 GHz 13.2 GHz to 26.5 GHz 26.5 GHz to 50 GHz Total absolute amplitude accuracy (10 dB attenuation, 20 to 30 °C, 10 Hz ≤ RBW ≤ 1 MHz, input signal –10 to –50 dBm, all settings auto-coupled except Auto Swp Time = Accy, any reference level, any scale) At 50 MHz At all frequencies Preamp on (Option E444xA-1DS) Preamp on (Option E444xA-110) ±0.24 dB (±0.06 dB typical) ±(0.24 dB + frequency response), ±(0.06 dB+ frequency response) typical 3 Hz to 3 GHz (95% confidence) ±0.19 dB ± (0.36 dB + frequency response), ±(0.09 dB+ frequency response) typical ± (0.40 dB + frequency response), ±(0.15dB + frequency response) typical 10 Amplitude Specifications (continued) Input voltage standing wave ratio (VSWR) (≥ 8 dB input attenuation) Preamp on (50 MHz to 3 GHz) (≥ 10 dB attenuation) Preamp on (Option E444xA-110) (> 10 dB input attenuation) E4443A/E4445A/E4440A E4447A/E4446A/E4448A 50 MHz to 3 GHz 3 GHz to 18 GHz 18 GHz to 26.5 GHz 26.5 GHz to 50 GHz < 1.2:1 nominal < 1.2:1 nominal < 1.6:1 nominal < 1.9:1 nominal < 1.57:1 nominal 200 MHz to 6.6 GHz 6.6 to 13.2 GHz 13.2 to 19.2 GHz 19.2 to 26.5 GHz 200 MHz to 6.6 GHz 6.6 to 13.2 GHz 13.2 to 19.2 GHz 19.2 to 31 GHz 31 to 50 GHz < 1.4:1 < 1.7:1 < 1.5:1 < 1.8:1 < 1.2:1 < 1.4:1 < 1.3:1 < 1.5:1 < 1.7:1 Resolution bandwidth switching uncertainty (referenced to 30 kHz RBW) 1 Hz to 1 MHz RBW 1.1 MHz to 3 MHz RBW 4, 5, 6, 8 MHz RBW ±0.03 dB ±0.05 dB ±1.0 dB Reference level Range Accuracy Log scale Linear scale 0 dB –170 dBm to +30 dBm in 0.01 dB steps 707 pV to 7.07 V in 0.1% steps Display scale switching uncertainty Switching between linear and log Log scale/div switching 0 dB 0 dB Display scale fidelity ≤ –20 dBm input mixer level –20 dBm < mixer level ≤ –10 dBm ±0.07 dB total ±0.13 dB total Spurious response (mixer level = –40 dBm) General spurious 100 Hz ≤ f < 10 MHz from carrier f ≥ 10 MHz from carier See frequency range for N 11 (–73 + 20 log N) dBc (–80 + 20 log N) dBc, (–90 + 20 log N) dBc typical Amplitude Specifications (continued) Second harmonic distortion (SHI) E4443A/E4445A/E4440A E4447A/E4446A/E4448A Preamp on (Option E444xA-1DS), for all models Preamp on (Option E444xA-110), for all models 10 MHz to 460 MHz (–40 dBm mixer level) 460 MHz to 1.18 GHz (–40 dBm mixer level) 1.18 GHz to 1.5 GHz (–40 dBm mixer level) 1.5 GHz to 2.0 GHz (–10 dBm mixer level) 2.0 GHz to 13.25 GHz (–10 dBm mixer level) 10 MHz to 460 MHz (–40 dBm mixer level) 460 MHz to 1.18 GHz (–40 dBm mixer level) 1.18 GHz to 1.5 GHz (–40 dBm mixer level) 1.5 GHz to 2.0 GHz (–10 dBm mixer level) 2.0 GHz to 3.25 GHz (–10 dBm mixer level) 3.25 GHz to 13.25 GHz (–10 dBm mixer level) 13.25 GHz to 25 GHz (–10 dBm mixer level) 10 MHz to 1.5 GHz (–45 dBm at preamp input) Distortion (dBc) –82 –92 –82 –90 –100 –82 –92 –82 –90 –94 –96 –100 nominal –60 nominal SHI (dBm) +42 +52 +42 +80 +90 +42 +52 +42 +80 +84 +86 +90 nominal +15 nominal 10 to 460 MHz (–45 dBm at preamp input) 460 MHz to 25 GHz (–45 dBm at preamp input) –55 nominal –60 nominal +10 nominal +15 nominal Distortion (dBc) –88 –90 –92 –94 –94 –90 –76 –84 –90 –92 –94 –96 –96 –92 –84 –84 –85 nominal TOI (dBm) +14 (+17 typical) +15 (+18 typical) +16 (+19 typical) +17 (+19 typical) +17 (+20 typical) +15 (+18 typical) +8 (+11 typical) +12 (+14 typical) +15 (+20 typical) +16 (+21 typical) +17 (+20 typical) +18 (+21 typical) +18 (+21 typical) +16 (+21 typical) +12 (+15 typical) +12 (+16 typical) +12.5 nominal –15 nominal –13 nominal Third-order intermodulation distortion (TOI) (two –30 dBm tones at input mixer with tone separation > 15 kHz, 20 to 30 °C ) E4443A/E4445A/E4440A E4447A/E4446A/E4448A Preamp on (Option E444xA-1DS), (for all models, two –45 dBm tones at preamp input) Preamp on (Option E444x-110), (two –45 dBm tones at preamp input) E4443A/E4445A/E4440A E4447A/E4446A/E4448A 10 MHz to 100 MHz 100 MHz to 400 MHz 400 MHz to 1.7 GHz 1.7 GHz to 2.7 GHz 2.7 GHz to 3.0 GHz 3.0 GHz to 6.0 GHz 6.0 GHz to 16 GHz 16 GHz to 26.5 GHz 10 MHz to 100 MHz 100 MHz to 400 MHz 400 MHz to 1.7 GHz 1.7 GHz to 2.7 GHz 2.7 GHz to 3.0 GHz 3.0 GHz to 6.0 GHz 6.0 GHz to 16 GHz 16.0 GHz to 26.5 GHz 26.5 GHz to 50 GHz 10 MHz to 500 MHz 500 MHz to 3 GHz 10 MHz to 3 GHz 3 to 6.6 GHz 6.6 to 13.2 GHz 13.2 to 19 GHz 19 to 26.5 GHz 10 MHz to 3 GHz 3 to 6.6 GHz 6.6 to 13.2 GHz 13.2 to 19 GHz 19 to 26.5 GHz –15 dBm nominal –21 dBm nominal –23 dBm nominal –23 dBm nominal –25 dBm nominal –15 dBm nominal –21 dBm nominal –23 dBm nominal –23 dBm nominal –25 dBm nominal 12 Amplitude Specifications (continued) –60 –80 o 5t 1.2 –90 z GH 1.5 Hz to z GH .1 25 M 00 4 –100 –110 –80 –130 –80 –90 –100 –70 –60 –50 –40 –30 –20 –10 –130 –80 -60 DA NL DA NL -70 = = -1 29 -1 27 dB m dB m ,R NL DA ,R BW = 41 -1 BW = = 1 1H z, m dB Hz ,4 31 .15 BW ,R = Dynamic range dBc 2. 4 to to 1 44 50 , Hz GH GH z z .4 26 to SOI = +90 dBM .15 31 -100 z GH -60 -50 -40 -30 –70 –60 –50 –40 –30 to H 0G GH zt o 1 5 3.2 –20 GH z –10 Figure 3. Nominal dynamic range – Bands 1 to 4, second and third order distortion, E4443A, E4445A, E4440A – 3 GHz to 26.5 GHz Nominal dynamic range for second- and third-order distortion bands 5 and 6 26.5 GHz to 50 GHz TOI = +12.5 dBm -110 -70 1.5 2.0 Mixer Level (dBm) Figure 2. Nominal dynamic range – Band 0, for second and third order distortion, E4443A, E4445A, and E4440A – 3 Hz to 3 GHz -90 z –110 Mixer Level (dBm) -80 2 13 0 to .2 2 to 6.5 6. 20 GH 3.0 6 to GH z to 13. z 6.6 2 G GH Hz z –120 –120 -50 DANL (1 HZ RBW) Second Harmonic Distortion Third Order Distortion –70 DANL and distortion relative to mixer level (dB) DANL and distortion relative to mixer level (dB) –60 DANL (1 HZ RBW) Second Harmonic Distortion Third Order Distortion –70 Nominal Dymamic Range Bands 1 to 4 6 to 16 GH 16 z to 2 6 . 5G 3 to 6 G Hz Hz Nominal Dymamic Range Band 0 -20 -10 Mixer level (dBm) [Input level minus attenuator setting] Figure 4. Nominal dynamic range – Bands 5 to 6, E4447A, E4446A, and E4448A 26.4 GHz to 50 GHz 13 Amplitude Specifications (continued) Residual responses Input terminated and 0 dB attenuation 200 kHz to 6.6 GHz 6.6 GHz to 26.8 GHz 26.8 GHz to 50 GHz –100 dBm –100 dBm nominal –90 dBm nominal Trace detectors Normal, peak, sample, negative peak, log power average, RMS average, and voltage average EMI detectors CISPR MIL-STD Peak, quasi-peak and average Peak Option E444xA-1DS, preamplifier Frequency range Gain Noise figure 100 kHz to 3 GHz 28 dB nominal 7 dB nominal Option E444xA-110, preamplifier Frequency range Gain Noise figure 10 MHz to 50 GHz 10 MHz to 30 GHz 30 to 50 GHz 10.0 MHz to 30 MHz 30 MHz to 3 GHz 3 to 30 GHz 30 to 50 GHz 27 dB (nominal) 24 dB (nominal) 12.5 dB (nominal) 7.8 dB (nominal) 10.3 dB (nominal) 21.8 dB (nominal) ≥ 50/s nominal 101 sweep points 401 sweep points 601 sweep points ≥ 45/s nominal ≥ 30/s nominal ≥ 25/s nominal Measurement speed Local measurement and display update rate Remote measurement and GPIB transfer rate 14 Other Specifications Option AYZ, external mixing Frequency range LO output Frequency range Power output (20 to 30 °C) 18 to 325 GHz (to 110 GHz with the Agilent unpreselected mixer) 3.05 GHz to 6.89 GHz E4440A E4446A and E4448A 14.5 dBm min 3.05 to 3.2 GHz 3.2 to 6.7 GHz 6.7 to 6.89 GHz 2.0:1 nominal VSWR IF input Frequency Maximum safe input range Absolute amplitude accuracy VSWR Mixer bias current Range Resolution Accuracy Output impedance Mixer bias voltage Range Preselector tune voltage 18.5 dBm max 14.5 dBm min 14.5 dBm min 14.5 dBm min 321.4 MHz, ±30 MHz 10 dBm ± 1.2 dB (20 to 30 °C) 1.5:1 nominal ± 10 mA 0.01 mA ± 0.02 mA nominal 477 Ω nominal ± 3.7 V (open circuit) 1.5 V/GHz of LO nominal Option 123, preselector bypass 1 Frequency range E4440A 3.05 to 26.5 GHz E4443A 3.05 to 6.7 GHz E4445A 3.05 to 13.2 GHz E4446A 3.05 to 44 GHz E4447A 3.05 to 42.98 GHz E4448A 3.05 to 50 GHz 1. When the preselector bypass option is installed and enabled, some aspects of the analyzer performance change. Please refer to the PSA specification guide for more details. 15 20 dBm max 18.8 dBm max 18.5 dBm max typical Power Suite Measurement Specifications Channel power Amplitude accuracy, W-CDMA or IS95 (20 to 30 °C, mixer level < –20 dBm) ±0.68 dB ( ±0.18 dB typical) Occupied bandwidth Frequency accuracy ±[span/600] nominal Adjacent channel power Accuracy, W-CDMA (ACLR) (at specific mixer levels and ACLR ranges) MS BTS Dynamic range (typical) Without noise correction With noise correction Offset channel pairs measured ACP speed (fast method). Data measurement and transfer time 30 ms nominal (0.2 dB standard deviation) Adjacent Alternate ±0.12 dB ±0.22 dB ±0.17 dB ±0.22 dB –74.5 dB –81 dB 1 to 6 –82 dB –88 dB Multi-carrier power and ACP ACPR dynamic range, W-CDMA (5 MHz offset, RRC weighted, 3.84 MHz noise bandwidth) Two carriers Four carriers With noise correction ACPR accuracy (two carriers, 5 MHz offset, –48 dBc ACPR) Multiple number of carriers measured –70 dB nominal –66 dB nominal –76 dB nominal ±0.38 dB nominal Up to 12 Power statistics CCDF Histogram resolution 0.1 dB Harmonic distortion Maximum harmonic number Results 10th Fundamental power (dBm), relative harmonics power (dBc), total harmonic distortion in % Intermod (TOI) Measure the third-order products and intercepts from two tones Burst power Methods Results Power above threshold, power within burst width Single burst output power, average output power, maximum power, minimum power within burst, burst width 16 Power Suite Measurement Specifications (continued) Spurious emission W-CDMA (1980 MHz region, 1.2 MHz RBW) Table driven spurious signals; search across regions. Relative dynamic range Absolute sensitivity 80.6 dB (82.4 dB typical) –89.7 dBm (–91.7 dBm typical) Spectrum emission mask (SEM) cdma2000® (750 kHz offset) Relative dynamic range (30 kHz RBW) Absolute sensitivity Relative accuracy 3GPP W-CDMA (2.515 MHz offset) Relative dynamic range (30 kHz RBW) Absolute sensitivity Relative accuracy 85.3 dB (88.3 dB typical) –105.7 dBm (–107 dBm typical) ±0.09 dB 87.3 dB (89.5 dB typical) –105.7 dBm (–107.7 dBm typical) ±0.10 dB 17 General Specifications Temperature range Operating Storage 0 °C to +55 °C –40 °C to +70 °C EMI compatibility Radiated and conducted emission is in compliance with CISPR Pub 11/1996 Class B Radiated immunity Complies with the radiated electromagnetic field immunity requirements in IEC/EM 61326 using performance criteria B. Audio noise ISO 7779 sound pressure Lp < 55 dBA Environmental conditions Samples of this product have been type tested in accordance with the Agilent Environmental Test manual and veified to be robust against the environmental stresses of storage, transportation and end-use, those stresses include but are not limited to temperature, humidity, shock, vibration, altitude and power line conditions. Test methods are aligned with IEC 60068-2 and levels are similar to MIL-PRF-28800F Class 3. Power requirements Voltage and frequency (nominal) Power consumption On Standby 100 to 120 V, 50/60/400 Hz 200 to 240 V, 50/60 Hz < 260 watts, no options, (< 450 watts, all options) < 20 watts Data storage Internal Floppy drive (10 to 40 °C) 512 MB (nominal) 3.5” 1.44 MB (nominal) Weight (without options) E4443A/E4445A/E4440A E4447A/E4446A/E4448A Net Shipping Net Shipping 23 kg (50 lbs) nominal 33 kg (73 lbs) nominal 24 kg (53 lbs) nominal 33 kg (73 lbs) nominal Dimensions Height Width Length 177 mm (7.0 in) 426 mm (16.8 in) 483 mm (19 in) Warranty The E4440A, E4443A, E4445A, E4446A, E4447A, and E4448A are supplied with a one-year standard warranty. Calibration cycle The recommended calibration cycle is two years. Calibration services are available through Agilent service centers. 18 Inputs and Outputs Front panel RF input Connector E4443A/E4445A E4440A Option E4440A-BAB E4447A/E4446A/E4448A Probe power Voltage/current (nominal) Ext trigger input Connector Impedance Trigger level range 1st LO output (Option AYZ) Connector Frequency range IF input (Option AYZ) Connector Frequency Type-N female, 50 Ω Type-N female, 50 Ω APC 3.5 male 2.4 mm male, 50 Ω +15 Vdc, ±7% at 150 mA max –12.6 Vdc, ±10% at 150 mA max BNC female 10 kΩ nominal –5 to +5 V SMA female 3 to 7 GHz SMA female 321.4 MHz Rear panel 10 MHz OUT (switched) Connector Output amplitude Frequency accuracy Ext Ref In Connector Input amplitude range Input frequency Frequency lock range Trigger in Connector External trigger input Trigger 1 and Trigger 2 outputs Connector Trigger 1 output Trigger 2 output BNC female, 50 Ω ≥ 0 dBm nominal 10 MHz ± (10 MHz x frequency reference accuracy) BNC female, 50 Ω –5 to +10 dBm nominal 1 to 30 MHz nominal ± 5 x 10-6 of specified external reference input frequency BNC female Impedance > 10 kΩ nominal Trigger level range –5 to +5 V BNC female HSWP (high = sweeping) Impedance 50 Ω nominal Level 5 V TTL Gate 19 Inputs and Outputs (continued) Rear panel (continued) Monitor output Connector VGA compatible, 15-pin mini D-SUB Format VGA (31.5 kHz horizontal, 60 Hz vertical sync rates, non-interlaced) Analog RGB Resolution 640 X 480 Noise source drive output (used by Option 219) Connector BNC female Output voltage On 28.0 ± 0.1 V (60 mA maximum) Off < 1 V Remote programming GPIB interface Connector IEEE-488 bus connector GPIB codes SH1, AH1, T6, SR1, RL1, PP0, DC1, C1, C2, C3, and C28, DT1, L4, C0 Serial interface connector 9-pin D-SUB male (factory use only) LAN TCP/IP interface RJ45 Ethertwist USB interface (Option 111, standard) Slave mode/device-side only, USB 2.0 compliant, type B connector Parallel printer interface connector 25-pin D-SUB female 321.4 MHz IF output 1 Connector SMA female, 50 Ω nominal Frequency 321.4 MHz nominal Conversion gain • Low band (3 Hz to 3.05 GHz) +2 to +4 dB nominal • High/mm band (2.85 GHz to –6 to –8 dB nominal PSA’s upper frequency limit) • High/mm band (2.85 GHz to –9 to –17 dB nominal PSA’s upper frequency limit); preselector off (Opt 123) Bandwidth (-3 dBm) • Low band (3 Hz to 3.05 GHz) 40 MHz or 60 MHz 2 nominal • High band (2.85 to 26.5 GHz) 35 to 70 MHz 3 nominal • mm band (26.5 to 50 GHz) 40 MHz or 60 MHz 2 nominal • High/mm band (2.85 GHz to 240 MHz nominal PSA’s upper frequency limit); preselector off (Option 123) Pre-sel tune output Connector BNC female 1. Not available for the E4447A. 2. 40 MHz standard, 60 MHz with Option 122 or 140 installed in instrument. When Option 122 or 140 is installed, the IF output signal is now centered at 300 MHz and the BW of the output centered at 300 MHz is approximately 95 MHz. 3. The bandwidth in the microwave preselected bands increases approximately monotonically between the lowest and highest tuned frequencies. Refer to the PSA Specifications Guide (E4440-90606) for more details. 20 PSA Series Ordering Information For further information, refer to PSA Configuration Guide, 5989-2773EN PSA Series spectrum analyzer Measurement Personalities E4443A E4445A E4440A E4447A E4446A E4448A E444xA-226 E444xA-219 Phase noise Noise figure E444xA-241 E444xA-BAF E444xA-210 E444xA-202 E444xA-B78 E444xA-214 E444xA-204 E444xA-BAC E444xA-BAE E444xA-217 E444xA-211 E444xA-212 E444xA-213 E444xA-215 E444xA-266 E444xA-233 E444xA-23A E444xA-23B E444xA-239 Flexible digital modulation analysis W-CDMA HSDPA/HSUPA (for W-CDMA) GSM w/ EDGE cdma2000 1xEV-DV 1xEV-DO cdmaOne NADC, PCD WLAN TD-SCDMA power measurement TD-SCDMA modulation HSPA for TD-SCDMA External source control Programming code compatibility suite Built-in measuring receiver personality AM/FM/PM triggering CCITT filter N9039A RF preselector control 3 Hz to 6.7 GHz 3 Hz to 13.2 GHz 3 Hz to 26.5 GHz 3 Hz to 42.98 GHz 3 Hz to 44 GHz 3 Hz to 50 GHz Options To add options to a product, use the following ordering scheme: Model E444xA (x = 0, 3, 5, 6, 7 or 8) Example options E4440A-B7J, E4448A-1DS Warranty & Service Standard warranty is one year. R-51B-001-3C 1-year return-toAgilent warranty extended to 3 years Calibration 1 Recommended calibration cycle is two years R-50C-011-3 Inclusive calibration plan, 3 year coverage R-50C-013-3 Inclusive calibration plan and cal data, 3 year coverage E444xA-0BW Service manual E444xA-UK6 Commercial calibration certificate with test data E444xA-A6J Factory ANSI Z540 standard-compliant calibration E444xA-1A7 Factory ISO 17025 standard-compliant calibration R-52A Calibration software and licensing (ordered with PSA) N7810A PSA Series calibration application software (stand-alone order) 1. Options not available in all countries 21 Requires Option IDS or 110 to meet specifications Requires B7J Requires B7J and BAF Requires B7J Requires B7J Requires B7J and B78 Requires B7J Requires B7J Requires B7J Requires 122 or 140 Requires Option 212 Requires Option 233 Requires Option 233 PSA Series Ordering Information (continued) For further information, refer to PSA Configuration Guide, 5989-2773EN Hardware E444xA-1DS E444xA-B7J E444xA-122 RF internal preamplifier (100 kHz to 3 GHz) RF/µW internal preamplifier (10 MHz to upper frequency limit of the PSA) Digital demodulation hardware 80 MHz bandwidth digitizer E444xA-140 40 MHz bandwidth digitizer E444xA-123 Switchable MW preselector bypass E444xA-124 E444xA-AYZ Y-axis video output External mixing E444xA-107 Audio input 100 kΩ E444xA-111 E444xA-115 USB device side I/O interface 512 MB user memory E444xA-117 E4440A-BAB E444xA-H70 Secure memory erase Replaces type-N input connector with APC 3.5 connector 70 MHz IF output E444xA-HYX E444xA-HY3 21.4 MHz IF output Switched LO for Options AYZ and 123 Excludes 122, 140. Not available for E4447A Available for all PSA models For E4446A/48A only BenchLink Web Remote Control Software Wide BW digitizer external calibration wizard Requires 122 or 140 E4443A/45A/40A/46A/48A E444xA-110 Excludes 110 Excludes 1DS E4440A/43A/45A/46A/48A, excludes 140, 107, H70 E4440A/43A/45A/46A/48A, excludes 122, 107, H70 Excludes AYZ (For E4446A/ 48A, Option HY3 allows coexistance of 123 and AYZ) E4440A/47A/46A/48A only, excludes 123 (For E4446A/ 48A, Option HY3 allows coexistance of 123 and AYZ) Requires 233 to operate; excludes 122, 140 Shipped standard in all PSA instruments with serial number prefix ≥ MY4615 unless 117 license is activated Excludes 115 PC Software E444xA-230 E444xA-235 Accessories E444xA-1CM E444xA-1CN E444xA-1CP E444xA-1CR E444xA-015 E444xA-045 E444xA-0B1 Rack mount kit Front handle kit Rack mount with handles Rack slide kit 6 GHz return loss measurement accessory kit Millimeter wave accessory kit Extra manual set including CD ROM 22 Related Literature Publication Title Publication Type Publication Number PSA in general Selecting the Right Signal Analyzer for Your Needs PSA Series PSA Series Self-Guided Demonstration for Spectrum Analysis Selection Guide Brochure Configuration Guide Product Note 5968-3413E 5980-1284E 5989-2773EN 5988-0735EN Technical Overview Application Note 1443 5989-1115EN 5988-7814EN Product Note 5988-5015EN Technical Overview 5989-0871EN Technical Overview Technical Overview Technical Overview Technical Overview Technical Overview Technical Overview Technical Overview Technical Overview Technical Overview Technical Overview Technical Overview Technical Overview Technical Overview Product Overview Data Sheet Technical Overview 5988-3698EN 5988-7884EN 5989-2240EN 5989-1119EN 5988-2388EN 5988-2389EN 5988-3694EN 5988-4828EN 5988-3695EN 5989-2781EN 5988-3697EN 5989-0056EN 5989-4795EN 5988-2610EN 5980-3115EN 5989-1111EN Technical Overview Product Overview 5989-1118EN 5988-5261EN Product Note Product Note Product Note Product Note Application Note 150 Application Note 150-15 Application Note Application Note 1453 Application Note 150-10 5980-3079EN 5980-3080EN 5980-3081EN 5980-3082EN 5952-0292 5989-1121EN 5988-5680EN 5988-9414EN 5968-3661E Wide bandwidth and vector signal analysis 40/80 MHz Bandwidth Digitizer Using Extended Calibration Software for Wide Bandwidth Measurements, PSA Option 122 & 89600 VSA PSA Series Spectrum Analyzer Performance Guide Using 89601A Vector Signal Analysis Software 89650S Wideband VSA System with High Performance Spectrum Analysis Measurement personalities and applications Phase Noise Measurement Personality Noise Figure Measurement Personality External Source Measurement Personality Flexible Digital Modulation Analysis Measurement Personality W-CDMA and HSDPA/HSUPA Measurement Personalities GSM with EDGE Measurement Personality cdma2000® and 1xEV-DV Measurement Personalities 1xEV-DO Measurement Personality cdmaOne Measurement Personality WLAN Measurement Personality NADC/PDC Measurement Personality TD-SCDMA Measurement Personality Built-in Measuring Receiver Personality/Agilent N5531S Measuring Receiver BenchLink Web Remote Control Software IntuiLink Software Programming Code Compatibility Suite Hardware options PSA Series Spectrum Analyzers Video Output (Option 124) PSA Series Spectrum Analyzers, Option H70,70 MHz IF Output Spectrum analyzer fundamentals Optimizing Dynamic Range for Distortion Measurements PSA Series Amplitude Accuracy PSA Series Swept and FFT Analysis PSA Series Measurement Innovations and Benefits Spectrum Analysis Basics Vector Signal Analysis Basics 8 Hints for Millimeter Wave Spectrum Measurements Spectrum Analyzer Measurements to 325 GHz with the Use of External Mixers EMI 23 www.agilent.com www.agilent.com/find/psa Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. cdma2000 is a registered certification mark of the Telecommunications Industry Association. Used under license. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. For information regarding self maintenance of this product, please contact your Agilent office. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada Latin America United States (877) 894-4414 305 269 7500 (800) 829-4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008 Europe & Middle East Austria 01 36027 71571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 €/minute www.agilent.com/find/removealldoubt Product specifications and descriptions in this document subject to change without notice. Germany 07031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: October 1, 2008 © Agilent Technologies, Inc. 2005, 2008 Printed in USA, November 15, 2008 5980-1284E