XP Power IH0509S Dc-dc power supply Datasheet

DC-DC
2 Watts
IH Series
xppower.com
•
Dual Output
•
SIP or DIP Package
•
Industry Standard Pinout
•
1000 VDC Isolation
•
Optional 3000-6000 VDC Isolation
•
Short Circuit Protection
•
-40 °C to +85 °C Operation
Specification
Input
Voltage
Input
Input Voltage Range
Input Current (no load)
Input Reflected Ripple
Input Reverse Voltage
Protection
•
•
•
•
Nominal ±10%
See table
20 mA rms
None
•
•
•
•
See table
None(6)
1.2%/1% ∆ Vin
±10% 20-100% load change
(3.3 V models ±20%)
±5%
60 mV pk-pk
0.02%/°C
1 s max
470 µF
No Load
Input Current
30
30
30
30
30
30
20
20
20
20
20
20
10
10
10
10
10
10
6
6
6
6
6
6
5 VDC
Output
Output Voltage
Minimum Load
Line Regulation
Load Regulation
Setpoint Accuracy
•
Ripple & Noise
•
Temperature Coefficient •
Short Circuit Protection •
Maximum Capacitive
•
Load
General
Efficiency
Isolation Voltage
Isolation Capacitance
Switching Frequency
MTBF
24 VDC
48 VDC
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
±200
±200
±111
±84
±66
±42
±200
±200
±111
±84
±66
±42
±200
±200
±111
±84
±66
±42
±200
±200
±111
±84
±66
±42
Efficiency
Model
Number(1,2)
65%
72%
77%
78%
80%
80%
67%
75%
77%
82%
82%
82%
68%
75%
80%
82%
82%
82%
60%
73%
77%
80%
80%
80%
IH0503S
IH0505S†
IH0509S†
IH0512S†
IH0515S†
IH0524S
IH1203S
IH1205S†
IH1209S†
IH1212S†
IH1215S†
IH1224S
IH2403S
IH2405S†
IH2409S†
IH2412S†
IH2415S†
IH2424S
IH4803S
IH4805S
IH4809S
IH4812S
IH4815S
IH4824S
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
† Available from Farnell, see pages 204-206.
• See table
• 1000VDC (for higher isolation
options - see note 2)
• 60 pF typical
• Variable
• >1 MHrs
Mechanical Details
SIP Package
DIP Package
0.78 (19.81)
max
0.80 (20.32)
max
0.01
(0.25) max
+Vin -Vin
-Vout 0V +Vout
0.30 (7.62)
max
0.50
(12.7)
0.09
(2.29)
Environmental
Operating Temperature
Storage Temperature
Case Temperature
Cooling
12 VDC
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
Output
Current(3)
Output
Voltage
-Vin
+Vin
1000 V Versions
•
•
•
•
-40 °C to +85 °C
-40 °C to +125 °C
100 °C max
Convection-cooled
Notes
1. For DIP package, replace ‘S’ with ‘D’ in model number.
2. Add suffix ‘-H’ to model number for 3000 VDC isolation. For higher VDC
isolation, add suffix ‘-Hx’ to model number where x=4 for 4000 VDC isolation,
x=5 for 5200 VDC isolation and x=6 for 6000 VDC isolation.
3. Outputs will power-trade.
4. 0.31” (9.65 mm) for all ‘-Hx’ versions.
5. All dimensions in inches (mm).
6. Operation at no load will not damage unit but it may not meet all specifications.
NC
0.30
(7.62)
0.60
(15.24)
0.01 (0.25)
0.28 (7.11)(4)
max
0.40
(10.16) max
0.12
(3.05) min
0.10 (2.54)
0.015
(0.38)
0.10 (2.54)
max
0.80 (20.32)
max
0.78 (19.81)
max
0.01
(0.25) max
+Vin -Vin
0.09
(2.29)
0.40
(10.16) max
+Vout 0V
-Vout
-Vout 0V +Vout
0.60
(15.24)
0.30 (7.62)
max
0.30
(7.62)
-Vin
+Vin
3000 V Versions
NC
0.40
(10.16) max
-Vout 0V +Vout
0.60
(15.24)
0.01 (0.25)
19-Nov-08