MPD LF201ES Low cost, 2w smt single output dc/dc converter Datasheet

LF200ES Series
Low Cost, 2W SMT
Single Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 2W Output Power
• Ultra-Miniature SMT Case
• 1,000 VDC Isolation
Parameter
• -40ºC to +85ºC Operation
• Single Output
• Low 0.24” Profile
• >3.5 MHour MTBF
• Industry Standard Pin-Out
• LOWEST COST!
Conditions
Input Voltage Range
Min.
Typ.
Max.
5 VDC Input
4.5
5.0
5.5
12 VDC Input
10.8
12.0
13.2
Reverse Polarity Input Current
Input Filter
Units
VDC
1.0
A
Max.
Units
Capacitor
Output
Parameter
Conditions
Min.
Output Voltage Accuracy
Typ.
±3.0
Line Regulation
For Vin Change of 1%
%
±1.2
%
±8
±15
%
Output Ripple (20 MHz)
75
150
mV P - P
Output Noise (20 MHz)
150
Load Regulation
For Iout = 10% to 100%
Temperature Coefficient
Output Short Circuit
250
mV P - P
±0.03
%/ºC
Max.
Units
Momentary (0.5 Sec.)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
60 Seconds
1,000
500 VDC
1,000
100 kHz, 1V
Switching Frequency
Typ.
VDC
M⍀
70
pF
100
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Storage Temperature Range
Min.
Typ.
Max.
Units
-40
+25
+85
ºC
+125
ºC
95
%
-55
Cooling
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
0.70 x 0.72 x 0.24 Inches (17.78 x 18.03 x 6.0 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
MicroPower Direct
Weight
292 Page Street
Suite D
Stoughton, MA 02072
USA
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
0.05 Oz (1.5g)
Parameter
Conditions
MTBF
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
Typ.
Max.
3.5
Units
MHours
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
Typ.
5 VDC Input
-0.7
7.0
12 VDC Input
-0.7
15.0
1.5 mm From Case For 10 Sec
Internal Power Dissipation
Max.
All Models
VDC
260.0
ºC
450
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
LF201ES
LF202ES
LF203ES
LF204ES
LF211ES
LF212ES
LF213ES
LF214ES
Voltage (VDC)
Nominal
5
5
5
5
12
12
12
12
Range
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
Output
Current (mA)
Full-Load
494
487
477
475
203
201
197
196
No-Load
30
30
30
30
15
15
15
15
Voltage
(VDC)
Current
(mA, Max)
5.0
9.0
12.0
15.0
5.0
9.0
12.0
15.0
400.0
222.0
167.0
133.0
400.0
222.0
167.0
133.0
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor be
placed from the +Vout pin to the -Vout pin.
3. During operation, care must be taken not to exceed the specified input range of the unit or to allow
the output load to drop below the specified minimum (10% of full load). Operating the unit under
either of these conditions could cause damage to the unit.
4. These converters are specified for operation without external components. However, in some applications the addition of input/output capacitors will enhance stability and reduce output ripple.
Recommended capacitor values are:
Vin
5 VDC
12 VDC
Input
Capacitor
4.7 µF
2.2 µF
Vout
5 VDC
9 VDC
12 VDC
15 VDC
40.0
23.0
17.0
14.0
40.0
23.0
17.0
14.0
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(mA)
81
82
84
84
82
83
85
85
500
500
500
500
200
200
200
200
Derating Curve
Output
Capacitor
4.7 µF
2.2 µF
1.0 µF
0.47 µF
For applications requiring very low output noise
levels, a simple LC filter should be effective.
5. It is recommended that a fuse be used on the
input of a power supply for protection. See the
Model Selection table above for the correct rating.
Mechanical Dimensions
Current
(mA, Min)
Recommended Solder Profile
Pin Connections
Pin
1
2
3
5
6
7
Function
Pin Function
-Vin
8
NC
+Vin
9
NC
NC
10
NC
NC
12
NC
-Vout
13
NC
+Vout
14
NC
NC = No Connection
Board Layout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]