Specification
Input
General
• 90-305 VAC, see derating curve
• 47-63 Hz
• 70 W: 1.2 A at 115 VAC, 0.6 A at 230 VAC,
100 W: 1.4 A at 115 VAC, 0.7 A at 230 VAC,
150 W: 2.0 A at 115 VAC, 1.0 A at 230 VAC
Inrush Current
• 65 A at 230 VAC, cold start +25 °C
Power Factor
• >0.94 at 230 VAC, full load
Earth Leakage Current • 750 µA max at 230 VAC
Input Protection
• DLG70/100 T2.0A/300V fuse fitted in line,
DLG150 T3.5A/300V fuse fitted in line
Input Voltage
Input Frequency
Input Current
Output
See table
No minimum load required
2 s max at 240 VAC
±0.5%
±5.0% of nominal output current
5% max
5% maximum deviation, recovery to within
1% in 10 ms for a 50% load change
Ripple & Noise
• DLG70: 700 mV
DLG100: 1000 mV
DLG150: 2000 mV (see note 2)
Overvoltage Protection • 110-142%, recycle mains to reset
Overtemperature
• Unit shuts down, recycle mains to reset
Protection
Overload Protection
• 105% maximum, auto recovery
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature
• 0.04%/°C
Coefficient
Output Voltage
Minimum Load
Start Up Delay
Line Regulation
Load Regulation
Turn On Overshoot
Transient Response
•
•
•
•
•
•
•
Efficiency
Isolation
Switching Frequency
MTBF
• See table
• 3750 VAC Input to Output
1880 VAC Input to Ground
500 VAC Output to Ground
• DLG50/70: 40-80 kHz
DLG100/150: PWM 60-80 kHz,
PFC 55-133 kHz
• >200 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature
Operating Humidity
Storage Temperature
Operating Altitude
Vibration
•
•
•
•
•
-30 °C to +70 °C (see derating curve)
5-100% RH, non-condensing
-40 °C to +80 °C
3000 m
10-500 Hz, 2 g, 10 mins/cycle, 6 cycles in
each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55015, class B conducted and radiated
• EN61000-3-2, class A
EN61000-3-2, class C for loads >80%
• EN61000-3-3
• EN61000-4-2, 8 kV air and 4 kV contact,
Perf Criteria A
• EN61000-4-3, level 2 Perf Criteria B
• EN61000-4-4, level 2 Perf Criteria B
• EN61000-4-5, installation class 3,
Perf Criteria B
• EN61000-4-6, level 2 Perf Criteria A
• EN61547, >95% 10 ms, 30% 200 ms, Perf
Criteria B, B for 70/100 W, A, A for 150 W
• EN61347, UL8750, CE Mark
AC-DC
DLG70-150-HV
Models and Ratings
Output Power
Output Voltage
Output Current
Efficiency(1)
Model Number
70 W
100 W
100 W
100 W
150 W
150 W
150 W
150 W
150 W
50 - 100 V
100 - 142 V
100 - 142 V
50 - 71 V
120 - 428 V
115 - 284 V
60 - 210 V
60 - 143 V
30 - 107 V
700 mA
700 mA
800 mA
1400 mA
350 mA
530 mA
700 mA
1050 mA
1400 mA
90.0%
91.0%
91.0%
91.0%
92.0%
92.0%
92.0%
92.0%
91.0%
DLG70PS700-A
DLG100PS700-A
DLG100PS800-A
DLG100PS1400-A
DLG150PS350-A
DLG150PS530-A
DLG150PS700-A
DLG150PS1050-A
DLG150PS1400-A
Notes
1. Typical efficiency at full load and 240 VAC input.
2. Measured using 12” twisted pair with 0.1 µF and 47 µF capacitors in parallel
at 20 MHz bandwidth.
Mechanical Details
A
B
H
D
C
F
4-R2.3 (DLG70/100)
4-R2.1 (DLG150)
AC IN
E
ACL
DC OUT
V+ (RED)
ACN
V- (BLACK)
18 AWGx2C (DLG70/100
and DLG150PS350-A)
16 AWGx2C
(All other DLG150)
18AWGx3C
F
11.81±0.79 (300±20)
11.81±0.79 (300±20)
G
ACL = Brown wire
ACN = Blue wire
A
B
C
D
E
F
G
H
= Green/Yellow wire
DLG70/100
DLG150
7.80 (198.0)
7.38 (187.4)
6.07 (177.0)
2.24 (57.0)
1.20 (30.6)
0.26 (6.7)
1.46 (37.0)
0.21 (5.3)
8.90 (226.0)
8.35 (212.0)
8.00 (203.2)
2.68 (68.0)
1.35 (34.2)
0.35 (8.9)
1.54 (39.0)
0.28 (7.0)
Notes
1. All dimensions shown in inches (mm).
2. Weight: DLG70/100: 1.65 lbs (750 g), DLG150: 2.29 lbs (1040 g)
3. Tolerance: ±0.02 (0.5)
Application Notes
Derating Curve
100
A
100
B
60
40
80
A
DLG70/100
B
DLG150
Load (%)
Load (%)
80
20
0
-30
60
40
20
0
10
20
30
Ambient Temp (˚C)
40
50 55 60
70
0
90
100
305
Input Voltage (VAC)