Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Dual Stage RFI Power Line Filters for Switching Mode Power Supplies EP / VP Series UL Recognized CSA Certified VDE Approved EP7 / VP7 1 EP1 / VP1 RFI Power Line Filters EP3 / VP3 EP & VP Series Specifications • Dual stage filter offers high insertion loss • Well suited for meeting CISPR 22 A and FCC Part 15J, Class B • EP model meets very low leakage current requirements • 7A and 12A versions offer optimum package size Ordering Information 3 EP 7 M Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: @250 VAC 50 Hz: VP Models EP Models .73 mA 1.27 mA .21 mA .36 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: Suffix M – Metric inserts (style 7 only) Omit for standard or none Input / Output Style 1 – .250 [6.3] spade terminals 3 – Wire leads 6 – Threaded bolt 7 – IEC inlet* (line side) .250 [6.3] spade terminals (load side) EP / VP Series EP – Low leakage (<0.5 mA) VP – Standard (20A only) 3 to 20A Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Available Part Numbers 3EP1 3EP3 3EP7 3EP7M 6EP1 6EP3 7EP1 7EP3 10EP1 10EP3 12EP1 12EP3 20EP1 20EP6 20VP1 20VP6 Current Rating 3, 6, 7, 10, 12 or 20A Accessories Electrical Schematic LINE GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord LOAD *IEC 60320-1 C14 inlet mates with C13 connector 27 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Dual Stage RFI Filters for Switching Power Supplies (continued) EP / VP Series Case Styles EP1 / VP1 (1-15A) EP7 & EP7M Tapped insert B D B D E A A C E C 20EP1 / VP1 20EP6 / VP6 B B D E A D E A C C Recommended Panel Cutout EP3 E D Brown .235 R 5.96 C .157 Dia. (2) 3.98 .910 23.11 Brown Blue Blue A B Green/ Yellow 1.295 32.89 1.575 40.01 28 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Dual Stage RFI Filters for Switching Power Supplies (continued) EP / VP Series Case Dimensions Part No. 3EP1 3EP3 6EP1 6EP3 7EP1 7EP3 10EP1 10EP3 12EP1 12EP3 20EP1/VP1 20EP6/VP6 B C D E Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 3EP 6EP db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 (continued) 12EP 20EP db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 1 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 20VP db 100 90 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 80 70 60 50 40 30 20 10 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 0.01 0.1 1 10 30 Frequency in MHz 7EP 10EP db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 RFI Power Line Filters 3EP7/7M Typical Insertion Loss A 0.01 0.1 1 10 30 Frequency in MHz 29 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com