XP Power AEJ36US24 Ac-dc power supply Datasheet

AEJ36 Series
AC-DC Power Supplies
XP Power
36 Watts
• Energy Efficiency Level VI
• European CoC Tier 2
• <0.075 W Standby Power
• Single Outputs 5 to 48 V
• Class II
• -20 °C to 60 °C Operation
• Universal Input
• 3 Year Warranty
Dimensions:
AEJ36:
4.37 x 2.01 x 0.78” (111.0 x 51.0 x 20.0 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
20 W
27 W
30 W
5.0 V
9.0 V
12.0 V
15.0 V
24.0 V
48.0 V
4.00 A
3.00 A
2.50 A
2.40 A
1.50 A
0.75 A
36 W
Total Regulation
Efficiency(1)
±5%
83.6%
87.3%
87.7%
88.3%
88.3%
88.3%
Model Number
AEJ36US05
AEJ36US09
AEJ36US12
AEJ36US15
AEJ36US24
AEJ36US48
Notes
1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 230 VAC input.
Mechanical Details
Cable Length: 5 V: 28” (720 mm) 18 AWG
Others: 48” (1220 mm) 18 AWG
1.97
(50.0)
IEC320-C8
0.78
(20.0)
4.33
(110.0)
0.47
(12.00)
Notes
1. All dimensions shown in inches (mm).
2. Weight: 0.38 lbs (190 g) approx.
3. Tolerance is ±0.02 (±0.5) maximum, except output cable length
which is ±2” (±50 mm)
1
4. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center +
and outer shell - polarity.
www.xppower.com
AEJ36 Series
AC-DC Power Supplies
Input
Characteristic
Minimum
Notes & Conditions
Maximum
Units
264
VAC
63
60
0.075
Hz
A
A
W
Max.
48
±2
Units
VDC
%
3
20
Full load and 115 VAC
±1
±6
s
ms
ms
%
%
Transient Response
5
%
Maximum deviation, recovering to less than 1% within
500 µs for 25% step load
Ripple and Noise
1
% pk-pk
175
143
%
%
%
Input Voltage
90
Input Frequency
Input Current
Inrush Current
No Load Input Power
Input Protection
47
Typical
1.0
Measured at 100VAC
230 VAC, cold start at 25 °C
T2.0A/250 VAC internal fuse in line
Output
Characteristic
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Total Regulation
Min.
5
Typ.
8
5
115
117
Trip and restart (hiccup), auto resetting
0.05
Overshoot
Overload Protection
Overvoltage Protection
Short Circuit Protection
Temperature Coefficient
Notes & Conditions
See Models and Ratings table
At 60% load
No minimum load required
Measured with 20 MHz Bandwidth and 10 µF electrolytic in
parallel with 0.1 µF ceramic capacitor.
At turn on / turn off
Recycle mains to reset
%/°C
Environmental
Characteristic
Operating Temperature
Cooling
Operating Humidity
Storage Temperature
Operating Altitude
Shock
Vibration
Minimum
-20
Natural convection
5
-20
Typical
Maximum
+60
Units
°C
90
%RH
+85
°C
2000
m
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes
IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes
Notes & Conditions
Derate from 100% load at 40 °C to 60% load at 60 °C
Non-condensing
Derating Curve
Output Power (%)
100
80
60
40
20
-20
40
Ambient Temperature (ºC)
www.xppower.com
60
2
AEJ36 Series
AC-DC Power Supplies
General
Characteristic
Minimum
Typical
Maximum
Units
88
Efficiency
Isolation: Input to Output
%
4242
See Models and Ratings table and curves.
VDC
Switching Frequency
67
kHz
Power Density
5.4
W/in3
0.38 (190)
lb (g)
Mean Time Between Failure
283
kHrs
Weight
Notes & Conditions
48 V version, MIL-HDBK-217F at 25 °C GB, 115 VAC
Efficiency Curves
AEJ36US12
100%
90%
Efficiency
80%
115Vac input
70%
230Vac input
60%
50%
10
20
30
40
50
60
70
80
90
100
Load (%)
AEJ36US24
100%
Efficiency
90%
80%
115Vac input
70%
230Vac input
60%
50%
10
20
30
40
50
60
70
80
90
100
Load (%)
EMC: Emissions
Phenomenon
Emissions
Harmonic Current
Voltage Flicker
Standard
EN55022
EN61000-3-2
EN61000-3-3
Test Level
Level B
Class A
www.xppower.com
Notes & Conditions
Conducted & Radiated
3
AEJ36 Series
AC-DC Power Supplies
EMC: Immunity
Phenomenon
Standard
ESD
Radiated
EFT/Burst
Surge
Conducted
Magnetic Fields
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Dips and Interruptions
EN61000-4-11
Test Level
Criteria
±8 kV Air, ±4 kV contact
3 V/m
2
2
3V
3 A/m
Dip: 30% 500 ms
Dip: 60% 100 ms
Int: 100% 5000 ms
Int: 100% 10 ms
A
A
A
A
A
A
A
A
B
A
Notes & Conditions
Line to Neutral
Safety Approvals
Safety Agency
Safety Standard
UL
Notes & Conditions
UL60950-1
TUV
EN60950-1
CB
IEC60950-1
Mechanical Details
Cable Length: 5 V: 28” (720 mm) 18 AWG
Others: 48” (1220 mm) 18 AWG
1.97
(50.0)
IEC320-C8
0.78
(20.0)
4.33
(110.0)
0.47
(12.00)
Notes
1. All dimensions shown in inches (mm).
2. Weight: 0.38 lbs (190 g) approx.
3. Tolerance is ±0.02 (±0.5) maximum, except output cable length
which is ±2” (±50 mm)
4. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center +
and outer shell - polarity.
www.xppower.com