Emerson Network Power LCM600L 600 watts bulk front end Datasheet

Embedded Power for
Business-Critical Continuity
Rev. 10.26.11_131
LCM600 Series
1 of 6
LCM600
600 Watts
Bulk Front End
Total Power:
600 W
# of Outputs:
Single
Output:
3.3 to 60 V
Optional 5.0 V standby
Electrical Specifications
Special Features
• 600 W output power
• Low Cost
• 2.4” x 4.5” x 7.5”
• 7.41 W/cu-in
• Industrial/Medical safety
• -40 °C to 70 °C with derating
• Optional 5 V @ 2 A Housekeeping
• High Efficiency: 89% typical
• Variable speed “Smart Fans”
• DSP controlled front end
• Conformal coat option
• ± 20% adjustment range
• Margin programming
• OR-ing FET
• Terminal block input option
Input
Input ra­nge:
85 - 264 Vac (Operating)
115/230 Vac (Nominal) Input through standard IEC connector
Frequency:
47 - 440 Hz, Nominal 50/60
Input fusing:
Internal 10 A fuses, both lines fused
Inrush current:
Power factor:
Harmonics:
Input current:
Hold up time:
Efficiency:
Leakage current:
≤ 25 A peak, either hot or cold start
0.99 typical, meets EN61000-3-2
Meets IEC 1000-3-2 requirements
8 A RMS max input current, at 100 Vac
20 ms minimum for Main O/P, at full rated load
> 88% at full load
< 0.3 mA at 264 Vac
ON/OFF power switch:
N/A
Power line transient:
Isolation:
MOV directly after the fuse
Compliance
PRI-Chassis 2500 Vdc Basic
PRI-SEC 2500 Vdc Reinforced
SEC-Chassis 500 Vdc
LCM600Q Efficiency Without the 5 Vsb and 24 V ORing FETS
• EMI Class B
• EN61000 Immunity
92.00
90.00
Safety
• UL
60950-1
508/1598/1433
60601-1
• CSA
60950-1
• VDE
60950-1
60601
• China
CCC
• CB Scheme Report/Cert
Efficiency %
88.00
86.00
100 Vac
230 Vac
84.00
82.00
80.00
78.00
76.00
25
50
75
Loading %
100
Embedded Power for
Business-Critical Continuity
Rev. 10.26.11_131
LCM600 Series
2 of 6
Output
Output rating:
See table 1
85 - 264 Vac
Set point:
Total regulation range:
± 0.5%
85 - 264 Vac
Combined line/load/transient when measured at output terminal
Main output ± 2%
5 Vsb ± 1%
600 W maximum
Main output @ 0.0 A
5 Vsb @ 0.0 A
1% max p-p
50 mV max p-p
Rated load:
Minimum load:
Output noise (PARD):
Derate linear to 50% from 50 °C to 70 °C
No loss of regulation
Output voltage overshoot:
Transient response:
< 300 µSec
Max units in parallel:
Short circuit protection:
Protected, no damage to occur
Remote sense:
Main output
5 Vsb output
Measured with a 0.1 µF Ceramic and 10 µF Tantalum Capacitor on
any output, 20 MHz
No overshoot/undershoot outside the regulation band during on or
off cycle
50% load step @ 1 A/µs
Step load valid between 10% to 100% of output rating
Recovery time to within 1% of set point at onset of transient
Up to 10
Bounce mode
Compensation up to 500 mV
Output isolation:
Standard per safety requirements
Forced load sharing:
Overload protection (OCP):
To within 10% of all shared outputs
105% to 125%
120% to 170%
Overvoltage protection (OVP): 125% to 145%
110% to 125%
Overtemp protection:
10 - 15 °C above safe operating area
Analog sharing control
Main output
5 Vsb output
12 V output
5 Vsb output
Both PFC and output converter monitored
Environmental Specifications
Operating temperature:
-40 °C to +70 °C, linear derating to 50% from 50 °C to 70 °C
Storage temperature:
-40 °C to +85 °C
Humidity:
20 to 90%, non-condensing. Operating. Conformal coat option available
Fan noise:
Altitude:
< 45 dBA, 80% load at 30 °C
Operating - 15,000 feet
Storage - 30,000 feet
MIL-STD-810F 516.5, Procedure I, VI. Storage
MIL-STD-810F 514.5, Cat. 4, 10. Storage
Shock:
Vibration:
Ordering Information
Current
Model
Number*
Output
Nominal Output
Voltage Set Point
Set Point
Tolerance
Adjustment
Range
Min
Max
Output Ripple
P/P
Power
Max.
Combined Line/
Load Regulation
Status
LCM600C
LCM600E
3V
5V
3V
5V
± 0.5%
± 0.5%
2.0 - 4.0 V
4.0 - 6.0 V
0A
0A
150 A
120 A
50 mV
50 mV
600 W
600 W
2%
2%
Coming Soon
Coming Soon
LCM600L
12 V
12 V
± 0.5%
9.6 - 14.4 V
0A
52 A
120 mV
600 W
2%
Released
LCM600N
15 V
15 V
± 0.5%
12.0 - 19.5 V
0A
44 A
150 mV
600 W
2%
Coming Soon
LCM600Q
24 V
24 V
± 0.5%
19.2 - 28.8 V
0A
27 A
240 mV
600 W
2%
Released
LCM600U
36 V
36 V
± 0.5%
28.8 - 43.2 V
0A
16.7 A
240 mV
600 W
2%
Released
LCM600W
48 V
48 V
± 0.5%
38.4 - 57.6 V
0A
14 A
280 mV
600 W
2%
Released
*Note: Add “-T” for terminal block instead of IEC input.
Embedded Power for
Business-Critical Continuity
Rev. 10.26.11_131
LCM600 Series
3 of 6
Pin Assignment
Signals
Name Description
Pin Number(s)
+Vout
Power rail
SK4
GND
Power GND
SK5
Signals
Name Description
A2
EEPROM Address
1
-VPROG
Return connection of external supply for Margin Programming
2
A1
EEPROM Address
3
-Vsense
Remote Sense Return
4
ISHARE
Load share voltage
5
A0
EEPROM Address
6
SDA1
Serial Data Signal (I2C)
7
+VPROG
SCL1
+Vsense
5VSB
GND
5VSB
G_DCOK_C
GPIOA6
Positive connection of external supply for Margin Programming
Serial Clock Signal (I2C)
Remote Sense Positive
5V standby
5V standby Return
5V standby
Global DCOK Collector
EEPROM Write Protect
8
9
10
11
12
13
14
15
G_DCOK_E
Global DCOK Emitter (GND)
16
GND
Return Ground for output signal and I2C communication
17
G_ACOK_C
Global ACOK Collector
18
INH_EN
Turn Off Main Output
19
G_ACOK_E
Global ACOK Emitter (GND)
20
SK2 Pin Number
Note: Mating connector for SK2 is LANDWIN CI0120P1HD0-LF
PSU Front View
Signal Output Signal Connectors (SK2)
LED Indicators
2 provided are clearly visible up to a 45 degree offset from vertical with office environment ambient lighting. The status is reflected in the
indicator color.
The DC_OK LED is bicolor. It shall light green if the DC output is within specification, and amber if the output falls out of specification.
The AC_OK LED is Green if the AC is within specification and off when out of specification. Note: With 5 V standby, Amber also indicates
that PSU is in standby mode/output off.
Control Signals
AC_OK Open collector 0.5 V maximum at 10 mA. Both emitter and collector access provided.
DC_OK Open collector 0.5 V maximum at 10 mA. Both emitter and collector access provided.
PS_INHIBIT/ENABLE Signal 0.0 - 0.5 V contact closure, output OFF
Embedded Power for
Business-Critical Continuity
Rev. 10.26.11_131
LCM600 Series
4 of 6
Mechanical Drawing - IEC Input
Weight: 2.84 lbs (1.29 Kg)
3.5 REF
190.5 ± 0.5
114.3 ± 0.5
PN 4176621060X
(PRNTG FRMT LCM600)
PROVISION FOR FUTURE
LABEL REQUIREMENTS
AIRFLOW DIRECTION
IEC320 AC INLET
CONNECTORS
LED
(DC OK/FAIL)
(8X) MOUNTING LOCATIONS
AT THIS SIDE & OPPOSITE SIDE
M4.0 X .7P THREAD
61.0 ± 0.5
LED
(AC OK)
(2X) 47.0 ± 0.5
(2X) 22.0 ± 0.5
SK1
NEG (SK5)
(2X) 6.0 ± 0.5
POS (SK4)
(2X) PN 39120205381
(SCREW-PP MC M3.5 X 6 W/ETW)
FOR 24, 36, 48 V
(4X) PN 39120205381
(SCREW-PP MC M3.5 X 6 W/ETW)
FOR 3, 5, 12 & 15 V
(2X) 10.0 ± 0.5
(2X) 17.65 ± 0.5
(2X) 182.5 ± 0.5
(2X) 177.5 ± 0.5
11.15 ± 0.5
(2X) 94.45 ± 0.5
(4X) MOUNTING LOCATIONS
AT THIS SIDE
M4.0 X .7P THREAD
Embedded Power for
Business-Critical Continuity
Rev. 10.26.11_131
LCM600 Series
5 of 6
Mechanical Drawing - Terminal Block Input
Weight: 2.84 lbs (1.29 Kg)
190.5 ±0.5
9.5
16.9
19.2 REF
9.5
GROUND
32.8
LIVE
12.8
114.3 ±0.5
NUETRAL
PRODUCT LABEL
LCM600Q-401
SCREW-MC PHILIP PAN
WITH EXT-T WASHER
M3.5 x P0.6 x 6
(15.75 )
(2X) 22± 0.5
POS - SK4
NEG - SK5
SK2 SIGNAL CONNECTOR - 20 WAY
(2X) 6 ± 0.5
(2X)182.5 ± 0.5
(2X)177.5± 0.5
11.15 ±0.5
(2X) 94.45 ± 0.5
(2X)10 ± 0.5
17.65 ±0.5
LED (AC OK)
(8X) MOUNTING LOCATIONS
BOTH SIDES
M4x0.7P THREAD
41.7
61 ±0.5
LED (DC/OK FAIL)
AIRFLOW DIRECTION
(2X) 47 ± 0.5
INPUT TERMINAL BLOCK
PROVISION FOR FUTURE
LABEL REQUIREMENTS
(4X) MOUNTING LOCATIONS
M4x0.7P THREAD
Embedded Power for
Business-Critical Continuity
Accessories
­Americas
Rev. 10.26.11_131
LCM600 Series
6 of 6
PIN 20
PIN 19
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
PIN 2
PIN 3
PIN 1
Europe (UK)
300 ± 5 mm
Order kit part number 73-788-001 for control connector interface with .3m wires attached
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
PIN 20
PIN 19
Asia (HK)
PIN 3
PIN 1
For global contact, visit:
PIN 2
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
Order kit part number 73-788-002 for control connector interface with unloaded housing and 20 pins @emerson.com
Miscellaneous Specifications
Burn-In
100% Burn-in at 45 °C, at 80 - 90 % load. Duration of burn-in determined by Quality Assurance
Procedures
MTBF
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
The power supply has a minimum MTBF of 300K hours using the Bell core 332, issue 6
specification @ 25 °C and 40 °C, ambient, at full load. With the power supply installed in a system in
a 25 °C ambient environment and operating at full load, capacitor life shall be 10 years, minimum
for ALL electrolytic capacitors contained within this power supply. The power supply shall
demonstrate a MTBF level of > 500,000 hours.
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Quality Assurance
Full QAV testing shall be conducted in accordance with Emerson Network Power Standards with
reports available upon request.
Warranty
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Emerson Network Power shall warrant the power supply to be free of defects in materials and
workmanship for a minimum period of three years from the date of shipment, when operated
within specifications. The warranty shall be fully transferable to the end owner of the equipment
powered by the supply.
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co. ©2011 Emerson Electric Co.
Similar pages