Vishay BAV20-TR Small signal switching diodes, high voltage Datasheet

BAV17 / 18 / 19 / 20 / 21
Vishay Semiconductors
Small Signal Switching Diodes, High Voltage
Features
• Silicon Epitaxial Planar Diodes
• Lead (Pb)-free component
• Component in accordance to RoHS
2002/95/EC and WEEE 2002/96/EC
e2
Applications
• General purposes
94 9367
Mechanical Data
Case: DO35 Glass case
Weight: approx. 125 mg
Packaging Codes/Options:
TR / 10 k per 13 " reel (52 mm tape), 50 k/box
TAP / 10 k per Ammopack (52 mm tape), 50 k/box
Parts Table
Part
Type differentiation
Ordering code
Remarks
BAV17
VRRM = 25 V, Single Diodes
BAV17-TAP or BAV17-TR
Ammopack / Tape and Reel
BAV18
VRRM = 60 V, Single Diodes
BAV18-TAP or BAV18-TR
Ammopack / Tape and Reel
BAV19
VRRM = 120 V, Single Diodes
BAV19-TAP or BAV19-TR
Ammopack / Tape and Reel
BAV20
VRRM = 200 V, Single Diodes
BAV20-TAP or BAV20-TR
Ammopack / Tape and Reel
BAV21
VRRM = 250 V, Single Diodes
BAV21-TAP or BAV21-TR
Ammopack / Tape and Reel
Absolute Maximum Ratings
Tamb = 25 °C, unless otherwise specified
Parameter
Test condition
Peak reverse voltage
Reverse voltage
Forward continuous current
Part
Symbol
Value
Unit
BAV17
VRRM
25
V
BAV18
VRRM
60
V
BAV19
VRRM
120
V
BAV20
VRRM
200
V
BAV21
VRRM
250
V
BAV17
VR
20
V
BAV18
VR
50
V
BAV19
VR
100
V
BAV20
VR
150
V
BAV21
VR
200
V
IF
250
mA
Peak forward surge current
tp = 1 s, Tj = 25 °C
IFSM
1
A
Forward peak current
f = 50 Hz
IFRM
625
mA
Ptot
500
mW
Power dissipation
Document Number 85543
Rev. 1.6, 20-Apr-06
www.vishay.com
1
BAV17 / 18 / 19 / 20 / 21
Vishay Semiconductors
Thermal Characteristics
Tamb = 25 °C, unless otherwise specified
Parameter
Junction to ambient air
Test condition
Symbol
Value
Unit
RthJA
300
K/W
Tj
175
°C
Tstg
- 65 to + 175
°C
l = 4 mm, TL = constant
Junction temperature
Storage temperature range
Electrical Characteristics
Tamb = 25 °C, unless otherwise specified
Parameter
Test condition
Max
Unit
VF
1000
mV
BAV17
IR
100
nA
VR = 50 V
BAV18
IR
100
nA
VR = 100 V
BAV19
IR
100
nA
VR = 150 V
BAV20
IR
100
nA
VR = 200 V
BAV21
IR
100
nA
Tj = 100 °C, VR = 20 V
BAV17
IR
15
μA
Tj = 100 °C, VR = 50 V
BAV18
IR
15
μA
Forward voltage
IF = 100 mA
Reverse current
VR = 20 V
Breakdown voltage
Min
Typ.
BAV19
IR
15
μA
Tj = 100 °C, VR = 150 V
BAV20
IR
15
μA
Tj = 100 °C, VR = 200 V
BAV21
IR
15
μA
IR = 100 μA, tp/T = 0.01,
tp = 0.3 ms
BAV17
V(BR)
BAV18
BAV19
VR = 0, f = 1 MHz
Differential forward resistance
Reverse recovery time
2
Symbol
Tj = 100 °C, VR = 100V
Diode capacitance
www.vishay.com
Part
25
V
V(BR)
60
V
V(BR)
120
V
BAV20
V(BR)
200
V
BAV21
V(BR)
250
V
CD
1.5
IF = 10 mA
rf
5
IF = IR = 30 mA,
iR = 3 mA,
RL = 100 Ω
trr
pF
Ω
50
ns
Document Number 85543
Rev. 1.6, 20-Apr-06
BAV17 / 18 / 19 / 20 / 21
Vishay Semiconductors
Typical Characteristics
Tamb = 25 °C unless otherwise specified
rf - Differential Forward Resistance (Ω)
1000
I R - Reverse Current (µA)
100
Scattering Limit
10
1
VR = VRRM
0.1
0.01
0
40
80
120
160
100
200
Tj - Junction Temperature (°C)
94 9084
1000
Tj = 25 °C
10
1
0.1
94 9089
Figure 1. Reverse Current vs. Junction Temperature
1
10
100
I F - Forward Current (mA)
Figure 3. Differential Forward Resistance vs. Forward Current
I F - Forward Current (mA)
1000
Tj = 25 °C
100
Scattering Limit
10
1
0.1
0
94 9085
0.4
0.8
1.2
1.6
2.0
V F - Forward Voltage (V)
Figure 2. Forward Current vs. Forward Voltage
Package Dimensions in mm (Inches): DO35
26 min. [1.024]
3.9 max. [0.154]
26 min. [1.024]
2 max. [0.079]
0.55 max. [0.022]
Cathode Identification
94 9366
Document Number 85543
Rev. 1.6, 20-Apr-06
www.vishay.com
3
BAV17 / 18 / 19 / 20 / 21
Vishay Semiconductors
Ozone Depleting Substances Policy Statement
It is the policy of Vishay Semiconductor GmbH to
1. Meet all present and future national and international statutory requirements.
2. Regularly and continuously improve the performance of our products, processes, distribution and operating
systems with respect to their impact on the health and safety of our employees and the public, as well as
their impact on the environment.
It is particular concern to control or eliminate releases of those substances into the atmosphere which are
known as ozone depleting substances (ODSs).
The Montreal Protocol (1987) and its London Amendments (1990) intend to severely restrict the use of ODSs
and forbid their use within the next ten years. Various national and international initiatives are pressing for an
earlier ban on these substances.
Vishay Semiconductor GmbH has been able to use its policy of continuous improvements to eliminate the use
of ODSs listed in the following documents.
1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments
respectively
2. Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental
Protection Agency (EPA) in the USA
3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C (transitional substances) respectively.
Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting
substances and do not contain such substances.
We reserve the right to make changes to improve technical design
and may do so without further notice.
Parameters can vary in different applications. All operating parameters must be validated for each
customer application by the customer. Should the buyer use Vishay Semiconductors products for any
unintended or unauthorized application, the buyer shall indemnify Vishay Semiconductors against all
claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal
damage, injury or death associated with such unintended or unauthorized use.
Vishay Semiconductor GmbH, P.O.B. 3535, D-74025 Heilbronn, Germany
www.vishay.com
4
Document Number 85543
Rev. 1.6, 20-Apr-06
Legal Disclaimer Notice
Vishay
Notice
Specifications of the products displayed herein are subject to change without notice. Vishay Intertechnology, Inc.,
or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies.
Information contained herein is intended to provide a product description only. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's
terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express
or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness
for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications.
Customers using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify Vishay for any damages resulting from such improper use or sale.
Document Number: 91000
Revision: 08-Apr-05
www.vishay.com