CSM_E32series_DS_E_10_1 Fiber Sensors Best Selection Catalog OMRON's Fiber Sensors continue to support an increasing range of applications. This catalog brings you the latest information on our Fiber Units. E32-series Fiber Units Amplifier Units E3X-DA-S/-MDA Series E3X-NA Series Standard Models P6 First, Our Standard Lineup These Fibers Units can be used in a variety of applications, such as detecting the presence of workpieces and positioning. A Wide Variety of Shapes for Adapting to Different Installation Locations Choose the model that suits the installation space from a wide variety of shapes and sizes. Space Savings and Simple Mounting Flat Models Flat models that allow simple screw mounting and straightforward wiring have been added to the lineup. Using these models eliminates the problem of fibers getting caught on surrounding objects. Flat model Detect Workpieces in Tight Spaces Custom-produced Sleeves Right angle Screw-shaped Cylindrical Flat Equipped with sleeve Models with sleeves allow detection in tight spaces. We will perform the time-consuming task of fashioning the sleeve, with a length and bends to suit the space (except for ultrafine sleeves). Models with sleeves Flexible, Pliable Fiber That Can Be Handled Like Wire We have developed a broad range of fibers to meet a wide variety of needs. Multicore (flexible) fiber is a new type of standard fiber that can be used like wire without worrying about the bending radius. We have also produced fiber that will not break when used in moving parts and fiber that is not degraded by contact with oil. Conventional fiber Flexible fiber You will certainly appreciate the ease of use that flexible fiber ensures. Length Can Be Specified in 1-m Units Saving Energy and Work We will produce fiber of the required length (in meter units). For large-scale installations, specifications of up to 20 m can be handled. (Specifications of 0.3 m and 0.5 m are also possible.) P10 Detection with Increased Reliability Special-beam Models A variety of heads incorporating the latest optical technology makes it possible to solve common problems related to detection and to increase reliability. Resistant to dust and dirt Capable of detecting small workpieces Resistant to workpiece vibration Use these models to handle unstable detection conditions. Environment-resistive Models Area-sensing models E32-T16J Small-spot models E32-C42+ E39-F3A Limited-reflective models E32-L24L High-power models E32-T17L High Resistance to External Conditions with Fiber P14 We have developed model variations for adapting to a variety of environmental conditions. These models enable detection in high-temperature environments and vacuums. High-temperature environments Environments subject to the splattering of chemicals Vacuums Use these models to handle applications in special environments. Heat-resistant models Chemical-resistant models Fiber Units for the Food-packaging, Semiconductor, and FPD Industries Application-corresponding Models P16 These models, which were developed for specific applications, offer top-quality detection performance. Label detection Liquid-level detection Alignment and mapping of glass substrates Wafer mapping Use these models for specific applications. Label-detection models Alignment-check models Liquid-level detection models E32-G14 E32-L16 E32-D36T Page Reference Type Standard models Feature/ applications Page 6 Special-beam models Page 10 Environment resistant models Page 14 Applicationcorresponding models Page 16 Accessories --- Variations Page 8 --- --- --- --- Type Throughbeam Page 19 Reflective Page 26 Throughbeam Page 22 Reflective Page 29 Throughbeam Page 24 Reflective Page 32 Ratings and performance Page 37 Page 38 Page 39 Page 33 (VacuumPage 25 resisitant) Page 35 Page 39 --- Dimensions Throughbeam Page 40 Reflective Page 48 Throughbeam Page 43 Reflective Page 51 Throughbeam Page 46 Reflective Page 56 Page 57 Page 47 (Vacuumresisitant) Page 60 Selection Guide Fiber Units We have developed model variations for handling a broad range of applications. Amplifier Units Fiber Units Detection conditions Environmental conditions Standard environments Standard Models Standard detection P.6 Environment-resistive Models Positioning Level differences Special-beam Models Marks Positioning Level difference P.10 Small spot Area sensing Retroreflective sensing Application-corresponding Models corresponding Workpiece presence ■ Long-distance sensing, resistance to dust and dirt ■ Small beam, resistance to rattling ■ Detection of transparent objects High power Application- P.14 ■ Workpiece presence ■ Positioning ■ Level differences and marks Workpiece presence Specialbeam ■ High-temperature environments (up to 400ºC) ■ Environments subject to scattering of chemicals and oil ■ Vacuum environments Special environments P.16 ■ Labels ■ Liquid level ■ Alignment and mapping of glass substrates ■ Wafer mapping Labels Liquid level Alignment Mapping Amplifier Units Type Digital Manual Appearance Response time 2-channel models 100 μs, 1 ms, or 4 ms 48 µs, 1 ms, or 4 ms (2-output models: 80 µs, 1 ms, or 4 ms) Light source Red, green, blue, or infrared LED Function Models 4 200 µs (high-speed models: 20 µs) Red or green LED Dual display (including digital, bar, percent, and hold display functions) Threshold adjustment performed manually or by teaching OFF-delay, ON-delay, one-shot timer (adjustable from 1 ms to 5 s) LED bar display (5 levels) 8-turn sensitivity adjuster OFF delay timer (fixed at 40 ms) Advanced-function models are available (2-output/input models). Water-resistant models are available. E3X-DA@-S E3X-DA@TW-S (2-output model) E3X-DA@RM-S (input model) E3X-MDA@ E3X-NA@ E3X-NA@F (high-speed model) E3X-NA@V (water-resistant model) CONTENTS ■ Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P4 ■ Overview of Features, Applications, and Variations Standard Models Flexible (New Standard) . . . . . . . . . . . . . . . . . . P6 Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P6 Break-resistant . . . . . . . . . . . . . . . . . . . . . . . . . . . P6 Fluorine Coating . . . . . . . . . . . . . . . . . . . . . . . . . . P7 Special-beam Models Long Distance, High Power . . . . . . . . . . . . . . P10 Ultracompact, Ultrafine Sleeve . . . . . . . . . . . . . . P10 Coaxial, Small Spot . . . . . . . . . . . . . . . . . . . . . . . P11 Fine Beam (Narrow Vision Field) . . . . . . . . . . . . P12 Area Sensing. . . . . . . . . . . . . . . . . . . . . . . . . . . . P12 Retroreflective . . . . . . . . . . . . . . . . . . . . . . . . . . . P13 Limited-reflective . . . . . . . . . . . . . . . . . . . . . . . . . P13 Environment-resistive Models Heat-resistant . . . . . . . . . . . . . . . . . . . . . . . . . . P14 Chemical-resistant. . . . . . . . . . . . . . . . . . . . . . . . P14 Vacuum-resistant . . . . . . . . . . . . . . . . . . . . . . . . P15 Application-corresponding Models Label Detection. . . . . . . . . . . . . . . . . . . . . . . . . P16 Liquid-level Detection . . . . . . . . . . . . . . . . . . . . . P16 Glass-substrate Alignment . . . . . . . . . . . . . . . . . P17 Glass-substrate Mapping . . . . . . . . . . . . . . . . . . P17 Water Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . P18 ■ Ordering Information Through-beam Fiber Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P19 Fiber Units with Reflective Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P26 Application-corresponding Fiber Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P33 ■ Ratings/Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P37 ■ Dimensions Through-beam Fiber Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P40 Fiber Units with Reflective Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P48 Application-corresponding Fiber Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P57 ■ Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P63 5 Features/Applications Standard Models R Flexible (New Standard) • Perform wiring without worrying about the bending radius. • Choose the model to suit the installation space from a variety of shapes. Flexible fiber Conventional fiber ■ Feature: Multicore (Flexible) Fibers Cores Cladding A large number of ultrafine cores are all surrounded by cladding. As a result, the fiber is flexible and can be bent without significantly reducing the light intensity. This helps solve problems, such as fiber being broken by getting caught on other objects. ■ Ratings/Characteristics Fewer problems Light intensity affected by bends in fiber Fiber broken by getting caught on surrounding objects Min. sensing ob0.005-mm dia. ject Min. bending ra1 mm dius Ambient temper−40°C to 70°C (no icing or condensation) ature range Fiber material Plastic Standard ■ Feature: Flat Models • Choose the model to suit the installation space from a variety of shapes. • New flat models allow space savings and simple installation. Flat models, which allow simple attachment and wiring, have been added to the lineup. Choose the model to suit the installation space from 3 sensing directions and 2 sizes, standard and small. ■ Ratings/Characteristics Min. sensing object Min. bending radius Ambient temperature range Screw-shaped Cylindrical Flat Equipped with sleeve Fiber material 0.005-mm dia. 10 or 25 mm* −40°C to 70°C (no icing or condensation) Plastic *Depends on the fiber diameter. B Break-resistant • Bundle-fiber models can be used for moving parts. • Capable of withstanding at least one million repeated bends (in typical applications). ■ Feature: Bundle Fibers The Fiber Units contain a large number of independent fine fibers, ensuring a high degree of flexibility. ■ Ratings/Characteristics Min. sensing object Min. bending radius Ambient temperature range Fiber material 6 0.005-mm dia. 4 mm (withstands repeated bending) −40°C to 70°C (no icing or condensation) Plastic ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì Standard Models U Fluorine Coating • Fiber degradation due to oil is prevented using a fluo- ■ Feature: Fluorine Coating roresin coating. (Cross section) • Free cutting is possible with cutter provided. Fluororesin coating Fluororesin is used as the sheath material to prevent fiber degradation resulting from oil adhesion. Oil is blocked! Note: The tip of the head is not chemical-resistant. ■ Ratings/Characteristics ■Applicable Models Standard models Flexible Break-resistant Models Min. bending radius 4 mm Ambient temperature range −40°C to 70°C (with no icing or condensation) Fiber material Plastic ■ Fiber Length vs. Sensing Distance Through-beam Fiber Units Fiber Units with Reflective Sensors (Fiber length of 2 m corresponds to (Fiber length of 2 m corresponds to 100%.) 100%.) ■Model Number Used for Ordering Standard model number + Fiber length Fiber length: 0.3 m, 0.5 m, or any length from 1 to 20 m (in 1-m units) Sensing distance (%) Fiber Length 0.005-mm dia. This customization/delivery service applies to standard models. It is aimed at reducing industrial waste and simplifying the installation procedure. Sensing distance (%) (Fiber Length, Sleeve Fiber Customization Service Length, and Bends) Min. sensing object 100 80 60 100 80 60 40 40 20 20 0 2 5 10 15 20 0 2 5 10 Fiber length (m) Sleeve Length and Bends ■Applicable Models E32-TC200B/E32-TC200F E32-DC200B/E32-DC200F The E32-DC200B cannot be bent. 15 20 Fiber length (m) ■ Model Number Used When Changing Only the Sleeve Length L Model: E32- *1 C200 *2 -S*3 ■ Model Number Used When Changing the Sleeve Length and Bends Total length L1 R Total length L2 R Model Numbers Incorporating the Bending Radius, R, and Dimensions L1 and L2 Specifying L1 Only (Units: mm) Specifying L2 Only (Units: mm) Bending radius R5 R7.5 R10 R12.5 L1 (±1) Model number 10 E32- *1 C200 *2 -S *3 A1 15 E32- *1 C200 *2 -S *3 A2 12.5 E32- *1 C200 *2 -S *3 B1 17.5 E32- *1 C200 *2 -S *3 B2 15 E32- *1 C200 *2 -S *3 C1 20 E32- *1 C200 *2 -S *3 C2 17.5 E32- *1 C200 *2 -S *3 D1 22.5 E32- *1 C200 *2 -S *3 D2 Bending radius R5 R7.5 R10 R12.5 L2 (±1) Model number 5 E32- *1 C200 *2 -S *3 A3 10 E32- *1 C200 *2 -S *3 A4 7.5 E32- *1 C200 *2 -S *3 B3 17.5 E32- *1 C200 *2 -S *3 B4 10 E32- *1 C200 *2 -S *3 C3 20 E32- *1 C200 *2 -S *3 C4 12.5 E32- *1 C200 *2 -S *3 D3 22.5 E32- *1 C200 *2 -S *3 D4 *1: Insert "T" for Through-beam Fiber Units and "D" for Fiber Units with Reflective Sensors. *2: Insert the "B" or "F" that appears at the end of the original model number. *3: Insert "50" if the total length is 50 mm. The total length must not exceed 120 mm. 7 Features/Applications Standard Models Sensing distance (mm) (See note 1.) Model Overview of Model Variations Through-beam Fiber Units Type Flexible (New Standard) (See note 2.) R Standard Break-resistant Fluorine coating U B (Cross section) Fluororesin coating Shape of head Flexible and pliable Withstands repeated bending [For dimensions, refer to page 40.] M4 Cable protected against oil 530 E32-T11N Screw-shaped M4 530 760 680 680 (top-view) E32-T11R M3 E32-TC200 130 E32-T21R (with sleeve) M4 (1.2-dia. sleeve) M3 (0.9-dia. sleeve) Cylindrical 220 E32-TC200E 530 E32-TC200BR E32-T11U 200 E32-T21 760 E32-TC200B 130 E32-TC200FR 3 dia. E32-T11 220 E32-TC200F 530 760 680 (top-view) E32-T12R 1.5 dia. E32-T12 130 E32-T222R 3 dia. E32-T12B 220 E32-T222 210 200 E32-T22B 460 (side-view) E32-T14LR 1 dia. E32-T14L 50 E32-T24R Flat 15 × 8 × 3 130 E32-T24 530 760 680 (top-view) E32-T15XR 12 × 7 × 2 E32-T15X 130 E32-T25XR 15 × 8 × 3 E32-T15XB 220 E32-T25X 210 150 E32-T25XB 460 (side-view) E32-T15YR 12 × 7 × 2 E32-T15Y 50 E32-T25YR 15 × 8 × 3 130 E32-T25Y 210 460 (flat-view) E32-T15ZR 12 × 7 × 2 E32-T15Z 50 E32-T25ZR 130 E32-T25Z Note 1. The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 2. These symbols are defined as follows. : Bendable fiber, R : Flexible fiber, B U : Fluorine-coated fiber. 8 ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì Standard Models Sensing distance (mm) (See note 1) Model Overview of Model Variations Fiber Units with Reflective Sensors Type Flexible (New Standard) (See note 2.) R Standard Break-resistant Fluorine coating U B (Cross section) Fluororesin coating Flexible and pliable Shape of head Withstands repeated bending [For dimensions, refer to page 40.] M6 Cable protected against oil 170 E32-D11N M6 170 E32-C11N M3 25 E32-C31N Screw-shaped M6 170 300 170 170 (top-view) E32-D11R M3 E32-DC200 30 E32-D21R (with sleeve) Cylindrical M6 (2.5-dia. sleeve) M3 (1.2-dia. sleeve) 3 dia. E32-D11 80 E32-DC200E 170 E32-DC200BR E32-D11U 30 E32-D21 300 E32-DC200B 30 E32-DC200FR 80 E32-DC200F 170 230 70 (top-view) E32-D12R 3 dia. (1.5 dia.) E32-D12 30 E32-D22R 6 dia. E32-D221B 80 E32-D22 45 30 E32-D22B 110 (side-view) E32-D14LR 2 dia. E32-D14L 15 E32-D24R Flat 15 × 10 × 3 30 E32-D24 170 300 170 (top-view) E32-D15XR 12 × 7 × 2 E32-D15X 30 E32-D25X 15 × 10 × 3 E32-D15XB 80 E32-D25X 40 50 E32-D25XB 100 (side-view) E32-D15YR 12 × 8 × 2 E32-D15Y 8 E32-D25YR 15 × 10 × 3 20 E32-D25Y 40 100 (flat-view) E32-D15ZR 12 × 8 × 2 E32-D15Z 8 E32-D25ZR 20 E32-D25Z Note 1. The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 2. These symbols are defined as follows. : Bendable fiber, R : Flexible fiber, B U : Fluorine-coated fiber. 9 Features/Applications Special-beam Models Long Distance, High Power • Powerful beam reduces influence of dust and dirt. • Long sensing distance enables use in large-scale installations. ■ Applications Detecting parts inside (trans- Detecting workpieces in lucent) containers coating processes E32-T11L E32-T17L ■ Ratings/Characteristics Ambient tempera−40°C to 70°C (no icing or condensation) ture range E32-T14 Fiber material Plastic ■ Overview of Model Variations Refle- Through-beam ctive Type Features Shape, sensing distance (mm)* 20,000 Equipped with large lens 3,400 Side-view, screw mounting E32-T14 1,330 M4 screw Model number E32-T17L E32-T11L Equipped with large lens 700 E32-D16 M6 screw 400 E32-D11L Ultracompact, Ultrafine Sleeve • Ultracompact head can be installed in tight spaces. • Ultrafine sleeve ensures reliable detection of small objects, such as electronic components. ■ Applications Alignment inspections Detection of terminals E32-D33 1 dia. E32-T33-S5 3 dia. E32-T223R ■ Ratings/Characteristics 0.22 dia. 3 dia. 0.5 dia. E32-T334-S5 Min. sensing object 0.005-mm dia. Ambient temperature range −40°C to 70°C (no icing or condensation) Material Plastic E32-D33 ■ Overview of Model Variations Refle- Through-beam ctive Type Features Shape, sensing distance (mm)* 130 E32-T223R 0.5-dia. sleeve (0.25-dia. opening) 44 E32-T33-S5 0.22-dia. sleeve (0.1-dia. opening) 5 E32-T334-S5 1-dia. cylinder 0.8-dia. sleeve 16 E32-D33 0.5-dia. sleeve 3 E32-D331 *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 10 Model number ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì Special-beam Models Coaxial, Small Spot • Small spot diameter (0.1 mm min. in diameter) enables ■ Applications the reliable detection of small workpieces. Detecting of CDs • Use of red light ensures easy visual recognition and simple positioning. E32-C31+ E39-F3C ■ Ratings/Characteristics E32-C42+ E39-F3A Min. sensing object 0.005-mm dia. Ambient temperature range −40°C to 70°C (no icing or condensation) Fiber material Plastic ■ Overview of Model Variations Coaxial, reflective Type Features Shape, sensing distance (mm)* Model number Coaxial, M6 screw 300 E32-CC200 Coaxial, 3-dia. cylinder 150 E32-D32L Small spot 0.1-dia. spot at a distance of 7 mm E32-C41+ E39-F3A-5 Small variable spot Spot diameter variable in the range 0.1 to 0.6 mm at distances in the range 6 to 15 mm E32-C42+ E39-F3A Long distance, small spot 0.5-dia. spot at 17 mm E32-C31+ E39-F3B Long distance, parallel light Spot diameter of 4 mm max. at E32-C31+ distances in the range 0 to 20 mm E39-F3C *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 11 mm 6 mm 7 mm 17 mm 0.1 mm dia. spot E32-C41+ E39-F3A-5 15 mm Variable from 0.1 to 0.6 dia. E32-C42+ E39-F3A 20 mm 4 mm dia. 0.5 mm dia. E32-C31+ E39-F3B E32-C31+ E39-F3C 11 Features/Applications Special-beam Models Fine Beam (Narrow Vision Field) • Fine beam reduces unwanted light in surrounding area. • Powerful beam allows use in applications requiring a long sensing distance. Approx. 60° ■ Applications Alignment inspection of orientation flats Approx. 4° E32-T22S ■ Ratings/Characteristics 1300 mm E32-T24S Min. bending radius 10 mm Ambient temperature range −40°C to 70°C (no icing or condensation) Fiber material Plastic ■ Overview of Model Variations Through-beam Type Features Shape, sensing distance (mm)* Model number Top view 1,900 E32-T22S Side view 1,300 E32-T24S *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). Area Sensing • These Fiber Units ensure greater reliability with the ■ Applications detection of position inconsistencies in passing workpieces and the presence of workpieces with holes. Detecting passage of • Wide sensing bands of 11 and 30 mm (through-beam candies models) enable the detection of large position inconsistencies. 11 mm Detecting chips on film E32-T16WR E32-T16PR ■ Ratings/Characteristics 30 mm E32-T16WR Ambient temperature range −40°C to 70°C (no icing or condensation) E32-T16W@ only: −25°C to 55°C Fiber material Plastic E32-D36P1 ■ Overview of Model Variations Reflective Through-beam Type Features Shape, sensing distance (mm)* Model number Sensing width: 11 mm 840 Sensing width: 11 mm Flat-view 750 E32-T16JR Sensing width: 30 mm 1,300 E32-T16WR Beam width: 11 mm E32-T16PR 150 E32-D36P1 *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 12 ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì Special-beam Models Retroreflective • The return optical path ensures that more light is interrupted by transparent workpieces than with through-beam models. • Equipped with MSR function to eliminate light reflected directly from the workpiece. ■ Applications Detecting translucent medicine E32-R21 ■ Ratings/Characteristics Ambient temperature range E32-R21: −40°C to 70°C E32-R16: −25°C to 55°C (with no icing or condensation) Fiber material Plastic E32-R16 ■ Overview of Model Variations Retroreflective Type Features Shape, sensing distance (mm)* MSR function, M6 screw Model number 250 E32-R21 MSR function, screw mounting, long distance 1,500 E32-R16 *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). Limited-reflective • Limited-reflective models eliminate light reflected from distant objects. • Small level differences can be reliably detected. • The optical-axis direction can be selected according to the installation space. ■ Applications Detecting connector pins Detecting wafers (glass substrates) E32-L25L Non-detection range Detection range E32-L24L ■ Ratings/Characteristics E32-L24L Min. sensing object 0.005-mm dia. Fiber material Plastic 200°C models only: Glass ■ Overview of Model Variations Limited-reflective Type Features Ultracompact, flat-view Ideal for checking stocks of glass substrates Heat-resistant up to 105°C, top-view Shape, sensing distance (mm)* Model number 0 to 4 E32-L24S 5.4 to 9 E32-L25L (center: 7.2) Wide sensing range, flat-view 0 to 15 E32-A10 Heat-resistant up to 200°C, flat-view 4 to 10 E32-L86 *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 13 Features/Applications Environment-resistant Models Heat-resistant • These Fiber Units can be used for various applications in temperatures up to 400°C. ■ Applications Detecting wafers in high-temperature environments E32-T61-S ■ Ratings/Characteristics 200°C and higher models E32-T81R All other models E32-D81R 150°C models Min. bending radius 35 mm 10 mm 25 mm Glass (fluoFiber material (fluororesin coating) roresin coating) Plastic E32-T84S-S Glass (SUS spiral coating) ■ Overview of Model Variations Refle- Through-beam ctive*2 Type Ambient temperature range Shape, sensing distance (mm)*1 Features −40°C to 150°C M4 screw 760 −40°C to 200°C L-shaped, long distance Model number E32-T51 1,300 E32-T84S-S −60°C to 350°C M4 screw 450 E32-T61-S −60°C to 350°C M6 screw 90 E32-D61-S −40°C to 400°C M6 screw, with sleeve 60 E32-D73-S *1 The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). *2 Order the Fiber Unit based on the Amplifier Unit. Use the E32-D@-S if the E3X-DA@-S, E3X-MDA@, or E3X-DAC@-S is used. Use the E32-D@ if any other Amplifier is used. Chemical-resistant • Built-in lens and high-power beam reduce the influence of dirt and drops of water. • Round design prevents drops of water sticking to the head (E32-T11F). ■ Applications Detecting workpieces in cleaning processes E32-T12F ■ Ratings/Characteristics Ambient temperature range E32-T14F Fiber material All other models E32-T51F E32-T81F-S −40°C to 70°C −40°C to 150°C −40°C to 200°C Plastic (fluororesin coating) Glass (fluororesin coating) ■ Overview of Model Variations Reflective*2 Through-beam Type Features Shape, sensing distance (mm)* Model number Water-resistant round head 2,000 E32-T11F Built-in lens, high power 3,000 E32-T12F Heat-resistant up to 200°C Built-in lens, high power 700 95 E32-T81F-S E32-D12F *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 14 ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì Environment-resistant Models Vacuum-resistant • These models can be used in high-vacuum environ- ■ Applications (Configuration Example) ments at pressures from 10-5 to 0.1 Pa. Vacuum chamber Atmospheric-pressure side Vacuum side Lens Unit E39-F1V • The 4-channel multi-flange, which has a maximum leakage rate of 1×10-10 Pa·m3/s, contributes to space savings. Fiber Unit on vacuum side (set of 2) Flange E32-T51V E32-VF4 (4 CH) E32-T54V E32-VF1 (1 CH) E32-T84SV Fiber Units on atmosphericpressure side (set of 2) E32-T10V Amplifier Unit E3X-DA-S E3X-NA ■ Ratings/Characteristics 120°C models Min. bending radius 200°C models 30 mm Atmosphericpressure side 25 mm Fiber mate- Glass (fluorores- Glass (SUS in coating) spiral coating) rial Plastic ■ Overview of Model Variations Through-beam Type Features Shape, sensing distance (mm)* Model number M4 screw, top-view, heat-resistant up to 120°C, long distance 1,000 L-shaped, heat-resistant up to 120°C 130 E32-T54V 1M L-shaped, long distance, heat-resistant up to 200°C 480 E32-T84SV 1M E32-T51V+ E39-F1V *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). Fiber Units on Atmospheric-pressure Side Appearance Type Model number Common E32-T10V 2M Type Model number 4-channel flange E32-VF4 1-channel flange E32-VF1 Flanges Appearance ■ Ratings/Characteristics Item Number of channels Model 4 channels 1 channels E32-VF4 E32-VF1 Leakage rate 1×10-10 Pa·m3/s max. Ambient temperature range Operating: −25°C to 55°C Storage: −25°C to 55°C Material Aluminum (A5056) Flange-seal material Fluorocarbon rubber (Viton) Weight (packed state) Approx. 280 g Stainless steel (SUS304) Aluminum (A5056) Approx. 240 g 15 Features/Application Application-corresponding Models Label Detection • Built-in lens and high-power beam enable the reliable detection of labels through a mounting board. • These Fiber Units can be washed with hydrogen peroxide, making them ideal for the food industry. ■ Applications Detecting labels ■ Ratings/Characteristics E32-G14 Ambient tempera−40°C to 70°C (no icing or condensation) ture range 10 mm E32-G14 Fiber material Plastic Degree of protection IP67 Type Features Through-beam ■ Overview of Model Variations Shape, sensing distance (mm)* Slot sensor, no adjustment of optical axis required Screw mounting, side-view Model number 10 E32-G14 3,400 E32-T14 *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). Liquid-level Detection ■ Operating Principle • Area sensing is possible with minimal influence from bubbles and drops of water (E32-A01/A02/D36T). Tube-mounting • For safety when disconnections occur, two models have been developed, a light ON model for liquid presTube Liquid Air ence and a light ON model for liquid absence (E32-A01/ A02). Tube-mounting model Liquid-contact model Liquid-contact model Air Liquid No liquid present E32-D36T E32-D82F1 Liquid present The presence/absence of liquid is detected using the refractive properties of light. More specifically, it utilizes the fact that the difference in refractive index between the air and the tip/tube is larger than the difference between the liquid and the tip/tube. ■ Overview of Model Variations Liquidcontact Tube-mounting Type Features Shape, sensing distance (mm)* Model number Light ON when liquid is present (ideal for checking lower limits) Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm and a rec- E32-A01 ommended wall thickness of 1 mm Light ON when liquid is absent (ideal for checking for overflow) Applicable tube: Transparent tube with a diameter in the range 6 to 13 mm and a recommended wall thickness of 1 mm No restriction on tube diameter, resistant to bubbles and drops of water Applicable tube: Transparent tube (no reE32-D36T striction on diameter) Heat-resistant up to 200°C, shape preLiquid-contact model vents liquid buildup E32-A02 E32-D82F1 *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 16 ì¡í²ÅEÉAÉvÉäÉPÅ[ÉVÉáÉì Application-corresponding Models Glass-substrate Alignment • There is little variation of detection position within the ■ Engineering Data (E32-A07/A08/L16-N) detection range (±0.1 mm max.) • The different model variations can handle a variety of Detection-Position Characteristic (Typical Examples) sensing distances and temperature conditions. Sensing object: Raw glass E32-A07 (t = 0.7 mm, rounded edge) Sensing distance, Y (mm) 25 X Y 20 15 10 E32-A08 5 E32-L16-N E32-L16-N 0 2.5 3.0 3.5 4.5 5.0 6.0 ■ Overview of Model Variations Type Features Shape, sensing distance (mm)* Limited-reflective 0 to 15 mm, wide-range sensing Model number 0 to 15 E32-L16-N 10 to 20 E32-A08 15 to 25 E32-A07E1 E32-A07E2 5 to 18 E32-L66 Long-distance sensing Heat-resistant up to 300°C *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). Glass-substrate Mapping 200 Rounded edge 150 Rate of change of digital light-intensity value (%) Digital light-intensity value • These models can reliably detect thin glass-substrate ■ Engineering Data (E32-A09) end faces (t = 0.5 mm, beveled edge). Digital Light-intensity Value vs Sensing Distance Angle Characteristics in Left and Right Directions (Typical Examples) (Typical Example) • Using a large-diameter lens makes it possible to cope 300 100 250 with tilting of the glass substrates. Beveled edge 100 50 0 0 10 20 30 40 50 60 70 75 50 25 0 −10 −8 Sensing distance, X (mm) Sensing object: Raw glass (t = 0.5 mm, beveled/rounded edge) X mm −6 −4 −2 0 2 4 6 8 10 Angle, θ (o) Sensing object: Raw glass (t = 0.5 mm, rounded edge) 25 mm +θ −θ Emission side Reception side E32-A09 Type Features Limited-reflective ■ Overview of Model Variations Large-diameter lens ensures resistance to tilting Shape, sensing distance (mm)* Model number E32-A09 15 to 38 (center: 25) Heat-resistant up to 150°C Heat-resistant up to 300°C E32-A09H 20 to 30 (center: 25) E32-A09H2 *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 17 Features/Applications Application-corresponding Models Wafer Mapping • Wafers are reliable detected with an ultrafine beam. • The optical axis is adjusted before delivery to allow easy installation. E32-A03 ■ Features Optical axis adjusted before delivery so that displacement is typically within 0.1°. Direction of rotation Vertical rotation ■ Engineering Data Rate of change of digital light-intensity value (%) E32-A03-1 8-inch Wafer Mapping Characteristic (Typical Examples) 180 Wafer piles can also be detected 160 140 120 100 80 170 mm 60 40 For 2 wafers X Fiber For 1 wafer 2-wafer pile 0 −10 −9 −8 −7 −6 −5 −4 −3 −2 −1 Distance moved, X (mm) Fiber 6.35 mm 20 0 1 2 3 Silicon wafer (t = 0.75 mm) 4 ■ Overview of Model Variations Type Features Shape, sensing distance (mm)* Through-beam Opening angle: 1.5° With mounting flange E32-A03 890 E32-A03-1 Opening angle: 3° ultraslim With mounting flange Model number E32-A04 340 E32-A04-1 *The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode). 18 Ordering Information Through-beam Fiber Units Standard models High-resolution mode Standard mode ( Type Appearance (mm) *2 Dimensions page High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Sensing distance (mm) Standard object Min. bend(min. sensing ing radius object) (mm) *1 (mm) Features Model number 40 M4 right angle E32-T11N 40 M4 screw E32-T11R 3-dia. cylinder E32-T12R Flat shape E32-T15XR M4 M4 700 40 530 350 (140) Standard size 3 dia. 40 15 × 8 × 3 1 dia. (0.005 dia.) 90 (40) ( ): E32-TC200B4R 40 E32-TC200BR M4 screw, with E32-TC200B4R sleeve M4 1.2 dia. Min. bending radius of sleeve: 5 3 dia. 3-dia. cylinder, E32-T14LR side-view Flexible (new standard) 40 41 15 × 8 × 3 270 210 130 (50) 41 15 × 8 × 3 Flat shape, side-view E32-T15YR Flat shape, flat-view E32-T15ZR M3 screw (small) E32-T21R 2-dia. cylinder (small) E32-T22R 1.5-dia. cylinder (small) E32-T222R Flat shape (small) E32-T25XR M3 screw (small), with sleeve E32-TC200FR E32-TC200F4R 1-dia. cylinder (small), side-view E32-T24R Flat shape (small), side-view E32-T25YR Flat shape (small), flat-view E32-T25ZR R R1 40 M3 40 2 dia. 40 1.5 dia. 160 130 75 (30) Small size 40 12 × 7 × 2 90 (40) ( ): E32-TC200F4R 0.5 dia. (0.005 dia.) 40 M3 0.9 dia. Min. bending radius of sleeve: 5 1 dia. 41 41 12 × 7 × 2 41 12 × 7 × 2 60 50 25 (10) *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *2. Indicates models that allow free cutting. Flexible Break-resistant Fluororesin coating 19 Through-beam Fiber Units Standard models High-resolution mode Standard mode ( Type Appearance (mm) *2 High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Dimensions page Sensing distance (mm) Standard object Min. bend(min. sensing ing radius object) (mm) *1 (mm) Features Model number 40 M4 screw E32-TC200 40 3-dia. cylinder E32-T12 Flat shape E32-T15X M4 M4 1,000 760 500 (200) 40 Standard size 15 × 8 × 3 90 (40) ( ): E32-TC200B4R M4 screw, with E32-TC200B sleeve E32-TC200B4 40 M4 1.2 dia. Min. bending radius of sleeve: 5 1 dia. (0.005 dia.) 3 dia. R25 3-dia. cylinder, E32-T14L side-view 40 600 41 15 × 8 × 3 460 300 (120) 41 15 × 8 × 3 Flat shape, side-view E32-T15Y Flat shape, flat-view E32-T15Z Standard 900 40 E32-TC200A 680 450 (180) M3 M3 screw (small) 40 E32-TC200E M3 40 2-dia. cylinder (small) E32-T22 1.5-dia. cylinder (small) E32-T222 Flat shape (small) E32-T25X M3 screw (small), with sleeve E32-TC200F E32-TC200F4 1-dia. cylinder (small), sideview E32-T24 Flat shape (small), sideview E32-T25Y Flat shape (small), flat-view E32-T25Z 2 dia. 40 Small size 1.5 dia. 270 220 125 (50) 40 12 × 7 × 2 90 (40) ( ): E32-TC200F4R 0.5 dia. (0.005 dia.) 40 M3 0.9 dia. Min. bending radius of sleeve: 5 1 dia. 41 41 12 × 7 × 2 41 12 × 7 × 2 160 130 75 (30) R10 *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *2. Indicates models that allow free cutting. Flexible 20 Break-resistant Fluororesin coating Standard models High-resolution mode Standard mode ( Type Appearance (mm) *2 High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Dimensions page Sensing distance (mm) Min. Standard object bending (min. sensing radius object) (mm) *1 (mm) Standard size 42 Model number M4 screw E32-T11 3-dia. cylinder E32-T12B Flat shape E32-T15XB M3 screw (small) E32-T21 2-dia. cylinder (small) E32-T221B 1.5-dia. cylinder (small) E32-T22B Flat shape (small) E32-T25XB M4 screw, fluorine coating E32-T11U M4 900 42 680 450 (180) 3 dia. 1 dia (0.005 dia.) 42 Break-resistant Features 15 × 8 × 3 B 42 Small size M3 R4 42 2 dia. 240 200 110 (45) 0.5 dia (0.005 dia.) 42 1.5 dia. 42 Coating 12 × 7 × 2 42 M4 180 150 85 (35) 900 680 450 (180) 1 dia. (0.005 dia.) U R4 *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *2. Indicates models that allow free cutting. Flexible Break-resistant Fluororesin coating 21 Through-beam Fiber Units Special-beam models High-resolution mode Standard mode ( Type Appearance (mm) *2 High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Dimensions page Sensing distance (mm) 43 20,000*3 20,000*3 10,000 (4,000) 40 60 4,000 3,700 2,400 (970) M14 M4 40 60 4,000*4 4,000*4 2,600 (1,500) 40 60 4,000*4 3,700 2,400 (970) Min. Standard object bending (min. sensing radius object) (mm) *1 (mm) 10 dia. 4 dia. (0.1 dia.) Long-distance, high-power R25 Large built-in lens, M14 screw E32-T17L R M4 right angle E32-T11N+ E39-F1 R25 M4 screw E32-TC200+ E39-F1 R M4 screw, flexible fiber E32-T11R+ E39-F1 R1 4,000*4 3,600 2,300 (930) B Screw mounting, side-view E32-T14 M4 screw E32-T11L 3-dia. cylinder E32-T12L R25 M4 screw, side-view E32-T11L+ E39-F2 R M4 screw, E32-T11R+ side-view, flexE39-F2 ible fiber R25 43 1,700 1,330 870 (350) M4 43 M4 screw, E32-T11+ break-resistant E39-F1 R4 4,000*4 3,400 2,250 (900) 43 Model number R1 M4 42 60 Features 1.4 dia. (0.01 dia.) 3 dia. 43 60 M4 40 60 42 60 910 800 500 (180) 520 400 250 (100) 3 dia. (0.1 dia.) R1 820 B 660 430 (160) R4 43 M3 43 540 440 250 (100) 0.9 dia. (0.005 dia.) M4 screw, E32-T11+ side-view, E39-F2 break-resistant M3 screw (small) E32-T21L 2-dia. cylinder (small) E32-T22L R10 2 dia. *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *2. Indicates models that allow free cutting. *3. The optical fiber is 10 m long on each side, so the sensing distance is 20,000 mm. *4. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm. Flexible 22 Break-resistant Fluororesin coating Special-beam models High-resolution mode Standard mode ( Type Appearance (mm) *2 Dimensions page Ultracompact, thin-sleeve 44 1 dia. 3 dia. 0.5 dia. 44 Sleeve cannot be bent. 3 dia. 0.25 dia. 160 130 75 (30) Standard object Min. bend(min. sensing ing radius object) (mm)*1 (mm) 0.5 dia. (0.005 dia.) R Model number 1-dia. cylinder, E32-T223R flexible fiber R1 53 44 25 (10) 0.5-dia. sleeve; 0.25dia. opening 0.25 dia. (0.005 dia.) E32-T33-S5 0.25-dia. sleeve, 0.125- E32-T333-S5 dia. opening 0.125 dia. (0.005 dia.) 44 6 5 3 (2) 0.1 dia. (0.005 dia.) 0.22-dia. sleeve, 0.1dia. opening 1.7 dia. (0.1 dia.) 3-dia. cylinder E32-T22S 44 2,500 1,900 1,250 (500) 44 1,750 1,300 870 (350) 3 dia. R10 E32-T334-S5 R10 3.5 dia. 45 3.5-dia. cylinE32-T24S der, side-view 2 dia. (0.1 dia.) 1,100 840 560 (220) R R1 11 1,500 1,100 750 (300) 45 45 Area-sensing Features 12 10 6 (4) Sleeve cannot be bent. Fine-beam Sensing distance (mm) 44 Sleeve cannot be bent. 3 dia. 0.22 dia. High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) 11 45 1,700 1,300 850 (340) 44 2,300 1,800 1,150 (450) 45 3,700 2,800 1,850 (740) 10 44 750 610 350 (140) E32-T16P (0.2 dia.) *3 R R1 1,300 1,000 650 (260) 30 M3 R10 980 750 480 (190) 44 E32-T16PR Area width: 11 mm Area width: 11 mm; sideview R10 R (0.3 dia.) *3 R1 R10 (0.6 dia.) *4 R25 2 dia. (0.1 dia) E32-T16JR E32-T16J E32-T16WR Area width: 30 mm E32-T16W Area width: 10 mm; long E32-T16 distance Multi-point detection (4E32-M21 head) *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *2. Indicates models that allow free cutting. *3. This is the value for which detection is possible within the sensing area, with the sensing distance set to 300 mm. (The sensing object is stationary.) *4. This is the value for which detection is possible within the sensing area, with the sensing distance set to give a digital value of 1,000. (The sensing object is stationary.) 23 Through-beam Fiber Units Environment-resistant models High-resolution mode Standard mode ( Type Appearance (mm) *2 Dimensions page High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Sensing distance (mm) 1,000 760 500 (200) 46 150°C *5 M4 46 2 dia. 46 Heat-resistant M4 M4 200°C *6 M4 46 60 300 230 150 (60) 360 280 180 (70) Min. Standard object bending (min. sensing radius object) (mm)*1 (mm) 1.5 dia. (0.1 dia.) 1 dia. (0.005 dia.) 600 R35 R10 3 dia. (0.1 dia.) 450 300 (120) 4,000*7 4 dia. (0.1 dia.) 3,400 2,200 (900) 46 60 R25 3 dia. 350°C *6 1,750 1.7 dia. 1,300 (0.1 dia) 870 (350) 46 46 M4 600 46 2,500 2,000 1,300 (520) 46 4,000*7 3,000 2,000 (800) Chemical-resistant 7.2 dia. 5 dia. 5 dia. 46 46 5 dia. 6 dia. 1 dia. (0.005 dia.) 450 300 (120) 46 500 400 250 (100) R4 4 dia. (0.1 dia.) 3 dia. (0.1 dia.) R40 1,800 4 dia. (0.1 dia.) 1,400 900 (350) 920 700 460 (190) 1 dia. (0.005 dia.) R10 Features Heat-resistant up to 150°C Heat-resistant up to 150°C; sideview Heat-resistant up to 200°C Heat-resistant up to 200°C; sideview Heat-resistant up to 200°C, long distance Heat-resistant up to 200°C; Lshaped; long distance Heat-resistant up to 350°C Fluororesin cover, round head Fluororesin cover, long distance Fluororesin cover, sideview Fluororesin cover, heatresistant up to 150°C *5 Fluororesin cover, heatresistant up to 200°C *6 Model number E32-T51 E32-T54 E32-T81R-S E32-T61-S+ E39-F2 E32-T61-S+ E39-F1 E32-T84S-S E32-T61-S E32-T11F E32-T12F E32-T14F E32-T51F E32-T81F-S *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *2. Indicates models that allow free cutting. *3. This is the value for which detection is possible within the sensing area, with the sensing distance set to 300 mm. (The sensing object is stationary.) *4. This is the value for which detection is possible within the sensing area, with the sensing distance set to give a digital value of 1,000. (The sensing object is stationary.) *5. For continuous operation, use the products within a temperature range of−40°C to 130°C. *6. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details. *7. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm. 24 Environment-resistant models High-resolution mode Standard mode High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) ( Appearance (mm) Dimensions page Sensing distance (mm) Standard object Min. bending (min. sensing obradius (mm) ject) (mm) * 47 260 200 130 (50) 1.2 dia. (0.01 dia.) 1,350 1,000 680 (260) 47 47 Vacuum-resistant Type M4 screw, heat-resistant up to 120°C M4 screw, heat-resistant up to 120°C, long distance L-shaped, heat-resistant up to 120°C L-shaped, heat-resistant up to 120°C, long distance L-shaped, heat-resistant up to 200°C, long distance 4 dia. (0.1 dia.) R30 47 210 130 100 (35) 1.2 dia. (0.01 dia.) 660 47 47 500 330 (180) 630 47 480 320 (130) 4 dia. (0.1 dia.) 2 dia. (0.1 dia.) Features R25 Model number E32-T51V 1M E32-T51V 1M+ E39-F1V E32-T54V 1M E32-T54V 1M+ E39-F1V E32-T84SV 1M * The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. Flanges Lens Units Appearance (mm) Dimensions page 47 47 Type Model number 4-channel flange E32-VF4 1-channel flange E32-VF1 Dimensions page 47 * Type Dimensions page 47 Model number Type E39-F1V Quantity Remarks 2 Long-distance Lens Unit Can be used for the E32-T51V and the E32-T54V. Mounting Brackets Appearance (mm) Fiber Units for Atmospheric-pressure Side Appearance (mm) Appearance (mm) Dimensions page 47 Type E39-L54V Quantity Remarks 2 Can be used for the E32-T54V. Amplifier-Flange E32-T10V 2M Connection Fiber Indicates models that allow free cutting. 25 Fiber Units with Reflective Sensors Standard models High-resolution mode Standard mode ( Type Appearance (mm) *3 High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Dimensions page Sensing distance (mm) *1 (Min. sensing Min. bending object) (mm) *2 radius (mm) Features Model number 48 M6 right angle E32-D11N 48 M6 screw E32-D11R 3-dia. cylinder E32-D12R 48 Flat shape E32-D15XR 48 M6 screw, with sleeve E32-DC200BR E32-DC200B4R 6-dia. cylinder, sideview E32-D14LR Flat shape, side-view E32-D15YR Flat shape, flat-view E32-D15ZR 48 M4 screw (small) E32-D211R 48 M3 screw (small) E32-D21R 3-dia. cylinder (small) E32-D22R 48 Flat panel (small) E32-D25XR 48 M3 screw (small), with sleeve E32-DC200FR E32-DC200F4R M6 M6 300 170 120 (50) 48 Standard size 3 dia. 15 × 10 × 3 Sleeve cannot be bent. M6 2.5 dia. 6 dia. Flexible (new standard) 49 80 45 30 (14) 49 15 × 10 × 3 70 40 26 (12) 49 15 × 10 × 3 (0.005 dia.) R R1 M4 M3 48 Small size 3 dia. 50 30 20 (8) 12 × 8 × 3 Min. bending M3 1.2 dia. radius of sleeve: 5 2 dia. 12 × 8 × 2 12 × 8 × 2 49 26 15 10 (4) 49 49 14 8 5 (2) 2-dia. cylinder (small), side-view Flat shape (small), side-view Flat shape (small), flat-view E32-D24R E32-D25YR E32-D25ZR *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. Flexible 26 Break-resistant Fluororesin coating Standard models High-resolution mode Standard mode ( Type Appearance (mm) *3 High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Dimensions page Sensing distance (mm) *1 Min. (Min. sensbending ing object) radius (mm) *2 (mm) 500 48 M6 screw 300 200 (90) M6 400 230 160 (70) 48 3 dia. Standard size Sleeve cannot be bent. E32-DC200 Flat shape E32-D15X M6 screw, with sleeve E32-DC200B E32-DC200B4 500 90 (40) ( ): E32-DC200B4 Model number 3-dia. cylinder E32-D12 48 15 × 10 × 3 Features 300 200 (90) 48 R25 M6 2.5 dia. 6 dia. 200 110 80 (36) 49 6-dia. cylinder, E32-D14L side-view 49 15 × 10 × 3 170 100 65 (30) 49 Standard 15 × 10 × 3 (0.005 dia.) 48 Flat shape, side-view E32-D15Y Flat shape, flat-view E32-D15Z M4 screw (small) E32-D211 M3 screw (small) E32-DC200E M4 48 M3 48 3-dia. cylinder E32-D22 (small) 130 80 50 (22) 3 dia. Small size 48 12 × 8 × 2 R10 ( ): E32-DC200F4 Min. bending radius of sleeve: 5 90 (40) 48 M3 1.2 dia. 2 dia. 12 × 8 × 2 12 × 8 × 2 49 50 30 20 (8) 49 49 35 20 12 (6) Flat shape (small) E32-D25X M3 screw (small), with sleeve E32-DC200F E32-DC200F4 2-dia. cylinder (small), E32-D24 side-view Flat shape (small), side-view E32-D25Y Flat shape (small), flat-view E32-D25Z *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. Flexible Break-resistant Fluororesin coating 27 Standard models Fiber Units with Reflective Sensors High-resolution mode Standard mode ( Appearance (mm) *3 Dimensions page Sensing distance (mm) *1 Min. (Min. sensing bending object) (mm) *2 radius (mm) 50 170 120 (50) Model number M6 screw E32-D11 50 Flat shape E32-D15XB M4 screw (small) E32-D21B 3-dia. cylinder (small) E32-D221B M3 screw (small) E32-D21 15 × 10 × 3 50 110 70 45 (20) M4 50 (0.005 dia.) Small size B R4 3 dia. 50 M3 50 50 30 20 (8) 1.5-dia. cylinder E32-D22B (small) 1.5 dia. 50 12 × 8 × 2 Coating Features 300 M6 Break-resistant Standard size Type High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) 50 M6 85 50 30 (15) 300 170 120 (50) (0.005 dia.) U Flat shape (small) E32-D25XB M6 screw, fluorine coating E32-D11U R4 *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. Flexible 28 Break-resistant Fluororesin coating Special-beam models High-resolution mode Standard mode ( Long-distance, high-power Type Appearance (mm) *3 Dimensions page High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Sensing distance (mm) *1 40 to 1,000 40 to 700 40 to 450 (40 to 240) 51 --- 650 51 R25 400 260 (110) M6 B R4 17.5 51 M4 51 210 130 80 (35) 3 dia. Ultracompact, thin-sleeve Min. (Min. sensing bending object) (mm) *2 radius (mm) Features Model number Large built-in lens, screw mounting E32-D16 M6 screw E32-D11L M4 screw E32-D21L 3-dia. cylinder E32-D22L 0.8-dia. sleeve E32-D33 0.5-dia. sleeve E32-D331 R10 (0.005 dia.) 51 3 dia. 0.8 dia. Sleeve cannot be bent. 25 16 10 (4) R4 51 2 dia. 0.5 dia. Sleeve cannot be bent. 5 3 2 (0.8) *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. 29 Fiber Units with Reflective Sensors Special-beam models High-resolution mode Standard mode ( Type Appearance (mm) *3 High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Dimensions page Sensing distance (mm) *1 280 170 160 (50) 52 M6 52 M3 52 M6 3 dia. R Coaxial, small-spot 52 M6 screw 500 E32-CC200 300 200 (90) 250 150 100 (45) 3-dia. cylinder E32-D32L M3 screw (small) 120 75 50 (22) (0.005 dia.) 52 60 6 to 15 mm; spot diameter: 0.1 to 0.6 mm 52 60 Spot diameter of 0.5 to 1 mm at distances in the range 6 to 15 mm 52 60 Spot diameter of 0.1 mm at 7 mm 52 60 Spot diameter of 0.5 mm at 7 mm 52 60 Spot diameter of 0.2 mm at 17 mm 52 60 Spot diameter of 0.5 mm at 17 mm 52 60 Spot diameter of 4 mm max. at distances in the range 0 to 20 mm Area-sensing Retroreflective 250 150 100 (45) 53 E39-R3 Reflector 53 E39-R3 Reflector E32-C31 2-dia. cylinder E32-D32 (small) R25 Small spot (variable) Small spot E32-C42+ E39-F3A E32-D32+ E39-F3A E32-C41+ E39-F3A-5 E32-C31+ E39-F3A-5 E32-C41+ Long distance, E39-F3B small spot E32-C31+ E39-F3B Long-disE32-C31+ tance sensing, E39-F3C parallel light 4-dia. spot M6 M3 right angle E32-C31N E32-CC200R 2 dia. 53 Model number R4 250 150 100 (45) 52 M3 Features M6 right angle E32-C11N 40 25 23 (7) 52 52 Min. (Min. sensbending ing object) radius (mm) *2 (mm) (0.005 dia.) B Beam width: 11 mm E32-D36P1 E32-R21+ E39-R3 (Attached) R4 10 to 250 10 to 250 10 to 250 (10 to 250) 150 to 1,500 150 to 1,500 150 to 1,500 (150 to 1,500) (0.1 dia.) R10 M6 screw (0.2 dia.) R25 Screw mount- E32-R16+ ing, long dis- E39-R1 (Attached) tance *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. Flexible 30 Break-resistant Fluororesin coating Special-beam models High-resolution mode Standard mode ( Type Appearance (mm) *3 Dimensions page High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Sensing distance (mm) *1 Min. (Min. sensing bending object) (mm) *2 radius (mm) 54 Convergent-reflective 54 3.3 3.3 3.3 (3.3) R25 Features Model number Small level differences, high E32-L25 power, side-view Small level differences, topview E32-L25A Ultracompact, flat-view E32-L24S Heat resistant up to 105°C *4, top-view E32-L24L E32-L25L 54 0 to 4 0 to 4 0 to 4 (0 to 4) 54 2 to 6 (center: 4) 2 to 6 (center: 4) 2 to 6 (2 to 6) (center: 4) 54 5.4 to 9 (center: 7.2) 5.4 to 9 (center: 7.2) 5.4 to 9 (5.4 to 9) (center: 7.2) Heat resistant up to 105°C *4, top-view 55 4 to 10 4 to 10 4 to 10 (4 to 10) Heat resistant up to 200°C, flat- E32-L86 view 55 1 to 5 1 to 5 1 to 5 55 0 to 8 0 to 8 0 to 6 0 to 4 (0.005 dia.) R10 Soda glass with reflection factor of 7% R25 Heat resistant up to 300°C E32-L64 Ideal for detecting glass stock. E32-A10 *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. *4. For continuous operation, use the products within a temperature range of −40°C to 90°C. 31 Environment-resistant models Fiber Units with Reflective Sensors High-resolution mode Standard mode ( Heat-resistant Type Appearance (mm) *3 150°C *4 High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Dimensions page 56 M6 200°C *5 Sensing distance (mm) *1 Min. (Min. sensing bending object) (mm) *2 radius (mm) 400 230 160 (72) 56 M6 350°C *5 56 150 90 60 (27) Heat resistant up to 150°C E32-D51 R10 Heat resistant up to 200°C E32-D81R-S E32-D81R*6 Heat resistant up to 350°C E32-D61-S E32-D61*6 Heat resistant up to 400°C, with sleeve E32-D73-S E32-D73*6 Fluororesin cover, long distance E32-D12F Fluororesin cover, sideview E32-D14F (0.005 dia.) M6 Chemical-resistant M4 1.25 dia. Min. bending radius of sleeve: 10 56 56 6 dia. 100 60 40 (18) 160 95 65 (30) (0.005 dia.) 7 dia. 56 70 40 30 (10) Model number R35 R25 400°C *5 Features R40 *1. The sensing distances are for white paper. *2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *3. Indicates models that allow free cutting. *4. For continuous operation, use the products within a temperature range of −40°C to 90°C. *5. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details. *6. Order the Fiber Unit based on the Amplifier Unit. Use the E32-D@-S if the E3X-DA@-S, E3X-MDA@, or E3X-DAC@-S is used. Use the E32-D@ if any other Amplifier is used. Flexible 32 Break-resistant Fluororesin coating Ordering Information Application-corresponding Fiber Units High-resolution mode Standard mode ( Glass-substrate-alignment Liquid-level detection Label-detection Type Appearance (mm) *2 Dimensions page 57 High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Sensing distance (mm) Standard object Min. bend(min. sensing ing radius object) (mm)*1 (mm) Model number Slot sensor (no adjustment of op- E32-G14 tical axis required) 10 10 10 (10) 4 dia. (0.1 dia.) R25 4,500 3,400 2,250 (900) 43 Features 57 Applicable tube: Transparent tube with a diameter in the range 8 to 10 mm and a recommended wall thickness of 1 mm 57 Applicable tube: Transparent tube (no restriction on diameter) 58 Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm and a recommended wall thickness of 1 mm 58 Applicable tube: Transparent tube with a diameter in the range 6 to 13 mm and a recommended wall thickness of 1 mm 58 Liquid-contact models 54 0 to 15 0 to 15 0 to 15 (0 to 12) R10 Screw mounting, side-view E32-T14 Compact E32-L25T No restriction on tube diameter, reE32-D36T sistant to bubbles and drops of water R4 R40 Light ON when fluid is present, resistant E32-A01 to bubbles and drops of water Light ON when fluid is not present, reE32-A02 sistant to bubbles and drops of water Heat resistant up to 200°C, fluororesin cover E32-D82F1 E32-D82F2 E32-L16-N Variation of detection position within E32-A08 the detection range: 0.1 mm E32-A07E1 *5 E32-A07E2 *5 58 10 to 20 10 to 20 10 to 20 (-) 58 15 to 25 15 to 25 10 to 20 (-) 58 5 to 18 5 to 18 5 to 16 (-) Heat resistant up to 300°C *3, *4 E32-L66 54 10 to 20 10 to 20 10 to 20 Heat resistant up to 300°C E32-A08H2 Soda glass with reflection factor of 7% R25 *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *2. Indicates models that allow free cutting. *3. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details. *4. These values are based on the assumption that there are no repeated sudden changes in temperature. *5. The characteristics for sensing object incline are different between the Attachments with model numbers ending in "E1" and "E2." Refer to page 52 for installation precautions. 33 Application-corresponding Fiber Units High-resolution mode Standard mode ( Appearance (mm) *2 Glass-substrate-mapping Type Dimensions page 59 59 59 3 dia. High-speed mode *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Super-high-speed mode) Sensing distance (mm) 15 to 38 (center: 25) 15 to 38 (center: 25) 15 to 38 (center: 25) (-) Edge of soda glass with reflection factor of 7% (t = 0.5 mm, rounded edge) 20 to 30 (center: 25) 20 to 30 (center: 25) 20 to 30 (center: 25) (-) 59 1,150 890 600 (250) 3 dia. 59 Wafer-mapping Min. Standard object bending (min. sensing radius object) (mm)*1 (mm) 44 Resistant to tilting E32-A09 R35 Heat resistant up to 150°C *3 E32-A09H R25 Heat resistant up to 300°C *4, *5 E32-A09H2 R Opening angle: 1.5°; optical axis adjusted E32-A03 before delivery R1 Opening angle: 1.5°; with mounting flange; optical axis E32-A03-1 adjusted before delivery 2 dia. (0.1 dia.) Long distance; opening angle: 4° R10 2 dia. 59 460 340 225 (100) 2 dia. 59 1.2 dia. (0.1 dia.) Model number R25 1,750 1,300 870 (350) 3.5 dia. Features E32-T24S Ultraslim (t = 2 mm); opening angle: 3°; E32-A04 optical axis adjusted before delivery Ultraslim (t = 2 mm); opening angle: 3°; with mounting E32-A04-1 flange; optical axis adjusted before delivery *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *2. Indicates models that allow free cutting. *3. For continuous operation, use the products within a temperature range of −40°C to 130°C. *4. The maximum temperature that can be withstood varies with the location. Refer to dimensions diagrams for details. *5. These values are based on the assumption that there are no repeated sudden changes in temperature. Flexible 34 Break-resistant Fluororesin coating Accessories Lens Units *When used in combination with the E3X-DA-S Amplifier Unit (general-purpose). Sensing distance (mm) Long-distance Lens Units Side-view Units Reflection Units Through-beam Lens Units Type Appearance Dimensions page 60 Applicable Fiber Units 4,000*2 3,200 2,100 840 E32-TC200 4,000*2 4,000*2 2,600 1,500 E32-T11R 4,000*2 3,700 2,400 970 E32-T11 4,000*2 3,600 2,300 930 E32-T11U 4,000*2 3,600 2,300 930 2,650 2,100 1,300 520 4,000*2 3,400 2,200 900 E32-T11L 910 800 500 180 E32-TC200 840 700 450 160 E32-T11R 520 400 250 100 E32-T11 820 660 430 160 E32-T11U 820 660 430 160 E32-T81R-S 360 280 180 70 E32-T61-S 600 450 300 120 E32-T61-S 60 E32-T11L E32-TC200 E32-T11R E32-T11 E32-T11U E32-T81R-S E32-T61-S E32-C42 60 Small-spot Lens Units E32-D32 Reflective Lens Units Highspeed mode E32-T11L E32-T81R-S 60 HighStandard resolution mode mode Superhighspeed mode --- Features Model number 4 dia. (0.1 dia.) Long-distance sensing; opening angle: 5° to E39-F1 40° (heat resistant up to 200°C) 3 dia. (0.1 dia.) Side-view, space-saving (heat E39-F2 resistant up to 200°C) --- Long distance reflection E39-F3 (heat resistant up to 200°C) Spot diameter variable in the range 0.1 to 0.6 mm at distances in the range 6 to 15 mm Small spot E39-F3A (variable) Spot diameter variable in the range 0.5 to 1 mm at distances in the range 6 to 15 mm E32-C41 0.1-dia. spot at a distance of 7 mm E32-C31 0.5-dia. spot at a distance of 7 mm E32-C41 Long distance, 0.5-dia. spot at a distance of 17 mm small spot Long-distance Spot diameter of 4 mm max. at distances in the range 0 to sensing, 20 mm parallel light 60 Small spot E39-F3A-5 60 E32-C31 60 Standard object (min. sensing object) (mm) *1 E32-C31 E32-C41 0.2-dia. spot at a distance of 17 mm E39-F3B E39-F3C *1. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing distance and sensitivity set to optimum values. *2. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm. 35 Accessories Protective Spiral Tube Appearance Dimensions page Application 61 Fiber protection 61 61 Applicable Fiber Units Tube length Model number M3-screw models E32-D21/E32-D21R E32-DC200E E32-DC200F@ E32-C31 500 mm E39-F32A5 1m E39-F32A M3-screw models E32-T21@ (Except the E32-T21R.) E32-TC200E E32-TC200F@ 500 mm E39-F32B5 1m E39-F32B M4-screw models E32-T11@ (except the E32-T11N Right-angle Model) E32-TC200 E32-TC200B@ E32-T51 E32-D21L/E32-D21B 500 mm E39-F32C5 1m E39-F32C M6-screw models E32-D11@ (except the E32-D11N Right-angle Model) E32-DC200 E32-DC200B E32-CC200@ E32-D51 500 mm E39-F32D5 1m E39-F32D Note: Before using a Protective Spiral Tube, remove the protective tube that protects the area between the head and the optical fiber provided with some models. The Lens Unit and Spiral Tube cannot be used at the same time. Other Accessories Appearance 36 Dimensions page Application Name Remarks Fiber Units that allow free cutting Provided with applicable Fiber Units. E39-F4 • 2 per set • Provided with applicable Fiber Units. E39-F9 62 Used to cut the fiber. 62 Attachments for in- Thin-fiber serting thin fibers Attachinto Amplifier Units ments Fiber Units that allow free cutting and have a 1.0-dia. sheath 62 Used to extend fibers. Fiber Units that allow free cutting and have a 2.2-dia. sheath Cutter Model number Applicable Fiber Units Fiber Connectors 62 Easy-to-use, onetouch relay connectors 62 Used to bends in sleeves. Sleeve Bender E32-TC200B(4) E32-TC200F(4) E32-DC200F(4) 62 Used to secure the 3.5-dia. Fiber Head Mounting Bracket E32-T24S E32-A03 Fiber Units that allow free cutting --- E39-F10 E39-F13: Used for Fiber Units with a 2.2-dia. sheath. E39-F14: Used for Fiber Units E39-F13 with a 1.0-dia. sheath. E39-F14 E39-F15: Used to connect FiE39-F15 ber Units with different sheath diameters, 1.0 mm and 2.2 mm. --- E39-F11 Provided with applicable Fiber Units. E39-L83 Ratings/Characteristics Standard models Models E32-D11 E32-D11N E32-D11R E32-D11U E32-D12 E32-D12R E32-D14L E32-D14LR E32-D15X E32-D15XB E32-D15XR E32-D15Y E32-D15YR E32-D15Z E32-D15ZR E32-D21 E32-D211 E32-D211R E32-D21B E32-D21R E32-D22 E32-D221B E32-D22B E32-D22R E32-D24 E32-D24R E32-D25X E32-D25XB E32-D25XR E32-D25Y E32-D25YR E32-D25Z E32-D25ZR E32-DC200 E32-DC200B(B4) E32-DC200BR(B4R) E32-DC200E E32-DC200F(F4) E32-DC200FR(F4R) E32-T11 E32-T11N E32-T11R E32-T11U E32-T12 E32-T12B E32-T12R E32-T14L E32-T14LR E32-T15X E32-T15XB E32-T15XR E32-T15Y E32-T15YR E32-T15Z E32-T15ZR E32-T21 E32-T21R E32-T22 E32-T221B E32-T222 E32-T222R E32-T22B E32-T22R Ambient operating Ambient hutemperature range midity range −40 to +70°C Fiber core material (sheath material) Plastic (PVC coating) Plastic (PVC coating) Plastic (PVC coating) Plastic (fluororesin coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) 35% to 85% Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (PVC coating) Plastic (PVC coating) Plastic (fluororesin coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (polyethylene coating) Permissible bending radius R4 R1 R1 R4 R25 R1 R25 R1 R25 R4 R1 R25 R1 R25 R1 R4 R10 R1 R4 R1 R10 R4 R4 R1 R10 R1 R10 R4 R1 R10 R1 R10 R1 R25 R25 R1 R10 R10 R1 R4 R1 R1 R4 R25 R4 R1 R25 R1 R25 R4 R1 R25 R1 R25 R1 R4 R1 R10 R4 R10 R1 R4 R1 Tightening force (N·m) 0.98 0.98 0.98 0.98 0.29 0.29 0.98 0.98 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.78 0.78 0.78 0.78 0.78 0.29 0.29 0.20 0.29 0.29 0.29 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.98 0.98 0.98 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.29 0.29 0.29 0.29 0.29 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.78 0.78 0.29 0.29 0.20 0.20 0.20 0.29 Pulling force (N) 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 29.4 29.4 29.4 9.8 9.8 9.8 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 9.8 29.4 9.8 9.8 9.8 9.8 9.8 9.8 IEC standard degree of protection IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP40 IP40 IP40 IP40 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP40 IP40 IP40 IP40 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP40 IP40 IP40 IP40 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 37 Standard models (continued) Models E32-T24 E32-T24R E32-T25X E32-T25XB E32-T25XR E32-T25Y E32-T25YR E32-T25Z E32-T25ZR E32-TC200 E32-TC200A E32-TC200B(B4) E32-TC200BR(B4R) E32-TC200E E32-TC200F(F4) E32-TC200FR(F4R) Ambient operating Ambient hutemperature range midity range −40 to +70°C Fiber core material (sheath material) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) 35% to 85% Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (PVC coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Permissible bending radius R10 R1 R10 R4 R1 R10 R1 R10 R1 R25 R25 R25 R1 R10 R10 R1 Tightening force (N·m) 0.29 0.29 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.78 0.78 0.78 0.78 0.78 0.78 0.78 Pulling force (N) 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 29.4 29.4 29.4 29.4 9.8 9.8 9.8 IEC standard degree of protection IP67 IP67 IP67 IP67 IP67 IP40 IP40 IP40 IP40 IP67 IP67 IP67 IP67 IP67 IP67 IP67 Special-beam models Ambient operating Ambient huFiber core material Permissible bend- Tightening Pulling temperature range midity range (sheath material) ing radius force (N·m) force (N) E32-A10 −40 to +70°C Plastic (polyethylene coating) R25 0.53 29.4 E32-C11N −40 to +70°C Plastic (combination of PVC and polyethylene) R4 0.98 29.4 E32-C31 −40 to +70°C Plastic (polyethylene coating) R25 0.78 9.8 E32-C31N −40 to +70°C Plastic (combination of PVC and polyethylene) R4 0.29 9.8 E32-C41 −40 to +70°C Plastic (polyethylene coating) R25 0.78 9.8 E32-C42 −40 to +70°C Plastic (polyethylene coating) R25 0.29 9.8 E32-CC200 −40 to +70°C Plastic (polyethylene coating) R25 0.98 29.4 E32-CC200R −40 to +70°C Plastic (polyethylene coating) R4 0.98 29.4 E32-D11L −40 to +70°C Plastic (polyethylene coating) R25 0.98 29.4 E32-D16 −40 to +70°C Plastic (PVC coating) R4 0.53 29.4 E32-D21L −40 to +70°C Plastic (polyethylene coating) R10 0.78 9.8 E32-D22L −40 to +70°C Plastic (polyethylene coating) R10 0.29 9.8 E32-D32 −40 to +70°C Plastic (polyethylene coating) R25 0.29 9.8 E32-D32L −40 to +70°C Plastic (polyethylene coating) R25 0.29 29.4 E32-D33 −40 to +70°C Plastic (polyethylene coating) R4 0.29 9.8 E32-D331 −40 to +70°C Plastic (polyethylene coating) R4 0.29 9.8 E32-D36P1 −40 to +70°C Plastic (polyethylene coating) R4 0.78 29.4 E32-L24L −40 to +105°C Plastic (polyethylene coating) R10 0.29 9.8 E32-L24S −40 to +70°C Plastic (polyethylene coating) R10 0.29 9.8 Plastic (polyethylene coating) R25 0.29 19.6 E32-L25 −40 to +70°C E32-L25A −40 to +70°C Plastic (polyethylene coating) R25 0.29 19.6 E32-L25L −40 to +105°C Plastic (polyethylene coating) R10 0.29 9.8 E32-L64 −40 to +300°C Glass (SUS spiral coating) R25 0.54 9.8 35% to 85% E32-L86 −40 to +200°C Glass (SUS spiral coating) R25 0.54 9.8 E32-M21 −40 to +70°C Plastic (PVC coating) R25 0.49. 0.78* 9.8 E32-R16 −25 to +55°C Plastic (polyethylene coating) R25 0.54 29.4 E32-R21 −40 to +70°C Plastic (polyethylene coating) R10 0.39 9.8 E32-T11L −40 to +70°C Plastic (polyethylene coating) R25 0.78 29.4 E32-T12L −40 to +70°C Plastic (polyethylene coating) R25 0.29 29.4 E32-T14 −40 to +70°C Plastic (polyethylene coating) R25 0.49 29.4 E32-T16 −40 to +70°C Plastic (polyethylene coating) R25 0.49 29.4 E32-T16J −40 to +70°C Plastic (PVC coating) R10 0.29 29.4 E32-T16JR −40 to +70°C Plastic (PVC coating) R1 0.29 29.4 E32-T16P −40 to +70°C Plastic (PVC coating) R10 0.29 29.4 E32-T16PR −40 to +70°C Plastic (PVC coating) R1 0.29 29.4 E32-T16W −25 to +55°C Plastic (PVC coating) R10 0.29 9.8 E32-T16WR −25 to +55°C Plastic (PVC coating) R1 0.29 9.8 E32-T17L −40 to +70°C Plastic (polyethylene coating) R25 0.78 29.4 E32-T21L −40 to +70°C Plastic (polyethylene coating) R10 0.78 9.8 Plastic (polyethylene coating) R1 0.20 9.8 E32-T223R −40 to +70°C E32-T22L −40 to +70°C Plastic (polyethylene coating) R10 0.29 9.8 E32-T22S −40 to +70°C Plastic (PVC coating) R10 0.29 29.4 E32-T24S −40 to +70°C Plastic (PVC coating) R10 0.29 29.4 E32-T333-S5 −40 to +70°C Plastic (polyethylene coating) R10 0.29 9.8 E32-T334-S5 −40 to +70°C Plastic (polyethylene coating) R10 0.29 9.8 E32-T33-S5 −40 to +70°C Plastic (PVC coating) R10 0.29 9.8 *The strength depends on the section. Use 0.49 N•m max. to 5 mm from the tip and 0.78 N•m max. at a distance of more than 5 mm from the tip. Models 38 IEC standard degree of protection IP30 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP40 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP50 IP40 IP50 IP50 IP50 IP50 IP40 IP50 IP66 IP67 IP67 IP67 IP67 IP67 IP50 IP50 IP50 IP50 IP50 IP50 IP67 IP67 IP67 IP67 IP50 IP50 IP67 IP67 IP67 Environment-resistant models Models E32-D12F E32-D14F E32-D51 E32-D61 E32-D61-S E32-D73 E32-D73-S E32-D81R E32-D81R-S E32-T11F E32-T12F E32-T14F E32-T51 E32-T51F E32-T51V E32-T54 E32-T54V E32-T61-S E32-T81F-S E32-T81R-S E32-T84S-S E32-T84SV Ambient operating Ambient hutemperature range midity range −40 to +70°C −40 to +70°C −40 to +150°C −60 to +350°C −60 to +350°C −40 to +400°C −40 to +400°C −40 to +200°C −40 to +200°C −40 to +70°C −40 to +70°C 35% to 85% −40 to +70°C −40 to +150°C −40 to +150°C −25 to +120°C −40 to +150°C −25 to +120°C −60 to +350°C −40 to +200°C −40 to +200°C −40 to +200°C −25 to +200°C Fiber core material (sheath material) Plastic (fluororesin coating) Plastic (fluororesin coating) Plastic (fluororesin coating) Glass (SUS spiral coating) Glass (SUS spiral coating) Glass (SUS spiral coating) Glass (SUS spiral coating) Glass (fluororesin coating) Glass (fluororesin coating) Plastic (fluororesin coating) Plastic (fluororesin coating) Plastic (fluororesin coating) Plastic (fluororesin coating) Plastic (fluororesin coating) Glass (fluororesin coating) Plastic (fluororesin coating) Glass (fluororesin coating) Glass (SUS spiral coating) Glass (fluororesin coating) Glass (fluororesin coating) Glass (fluororesin coating) Glass (SUS spiral coating) Permissible bending radius R40 R40 R35 R25 R25 R25 R25 R10 R10 R4 R40 R40 R35 R40 R30 R35 R30 R25 R10 R10 R25 R25 Tightening force (N·m) 0.78 0.78 0.98 0.98 0.98 0.78 0.78 0.78 0.78 0.29 0.78 0.78 0.78 0.78 0.29 0.29 0.29 0.78 0.78 0.78 0.29 0.29 Pulling force (N) 29.4 29.4 29.4 29.4 29.4 29.4 29.4 9.8 9.8 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 29.4 9.8 9.8 9.8 29.4 IEC standard degree of protection IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 --IP67 --IP67 IP67 IP67 IP67 --- Fiber core material (sheath material) Plastic (fluororesin coating) Plastic (fluororesin coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Glass (SUS spiral coating) Plastic (polyethylene coating) Plastic (fluororesin coating) Glass (SUS spiral coating) Plastic (polyethylene coating) Tip: Glass and fluororesin coating Amplifier insert: Plastic (fluororesin coating) (Fluororesin coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Plastic (polyethylene coating) Glass (SUS spiral coating) Plastic (polyethylene coating) Permissible bending radius R4 R4 R1 R10 R10 R10 R25 R25 R25 R25 R35 R25 R4 Tightening force (N·m) ----0.29 0.29 0.29 0.29 0.53 0.53 0.53 0.53 0.53 0.53 --- Pulling force (N) 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 29.4 9.8 9.8 9.8 29.4 IEC standard degree of protection IP50 IP50 IP50 IP50 IP50 IP50 IP40 IP40 IP30 IP40 IP40 IP40 IP67 Application-corresponding models E32-A01 E32-A02 E32-A03 E32-A03-1 E32-A04 E32-A04-1 E32-A07E1(E2) E32-A08 E32-A08H2 E32-A09 E32-A09H E32-A09H2 E32-D36T Ambient operating Ambient hutemperature range midity range −40 to +70°C −40 to +70°C −40 to +70°C −40 to +70°C −40 to +70°C −40 to +70°C −40 to +70°C −40 to +70°C −40 to +300°C −40 to +70°C −40 to +150°C 35% to 85% −40 to +300°C −40 to +70°C E32-D82F1 −40 to +200°C E32-D82F2 E32-G14 E32-L16-N E32-L25T E32-L66 E32-T14 −40 to +200°C −40 to +70°C −40 to +70°C −40 to +70°C −40 to +300°C −40 to +70°C Models R40 0.29 29.4 IP68 R40 R25 R25 R10 R25 R25 0.29 0.49 0.29 --0.53 0.49 29.4 29.4 29.4 9.8 9.8 29.4 IP68 IP67 IP40 IP50 IP40 IP67 39 (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Through-beam Fiber Units Through-beam models consist of two parts: an emitter and a receiver. Flexible Standard Standard/Flexible Models E32-T11N 8.4 dia. Break-resistant Fluororesin coating R@ Standard Cutting free (Cutter provided) Model display tube 2.2 dia. 7 E32-TC200 E32-T11R R25 Sensing surface: 1 dia. 7 5.5 2,000 M4×0.7 (brass/nickel plating) Width 7, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) M2.6×0.45 2.2 dia. 4.7 14.7 (45) 10 3 M4×0.7 (brass/nickel plating) M2.6×0.45 M4 nuts (brass/nickel plating) Washer (nickel-plated iron) included (4 of each) 3 3.2 14 Sensing surface: 1 dia. E32-TC200E E32-TC200A E32-T21R R10 Sensing surface: 0.5 dia. M3×0.5 (brass/nickel plating) R25 M3×0.5 (brass/nickel plating) Sensing surface: 1 dia. * Width 5.5, thickness 1.8 (nickel-plated brass) Washer (nickel-plated brass) 2,000 Width 5.5, thickness 1.8 (nickel-plated brass) Washer (nickel-plated brass) 2.2 dia. 1 dia. 3 dia. E39-F9: Included 2.5 11 2,000 9.5 13.5 2,000 E32-T22 R10 E32-T22R *E32-T21R: 0.5 dia. E32-T12 R25 E32-T12R 2 dia. (SUS303) Sensing surface: 0.5 dia. Heat-shrinkable tube 1.4 dia. E39-F9: Included 12 17 22 2.2 dia. 3 dia. (brass/nickel plating) 11 3 2,000 E32-T222 R10 E32-T222R 2.4 dia. Sensing surface: 1 dia. 1 dia. 14 2,000 E32-T15X R25 E32-T15XR Sensing surface: 0.5 dia. 1.5 dia. (brass/nickel plating) E39-F9: Included 10 Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on both sides (aluminum) Sensing surface: 1 dia. 1 dia. 8 2.2 dia. 5.5 1.5 2,000 3 2.5 7.5 2,000 15 Note: 1. Set of two symmetrical parts. 2. Mounting screws (countersunk screw M2 × 8 4 pcs) included E32-T25X R10 E32-T25XR Sensing surface: 0.5 dia. E32-TC200B R25 E32-TC200B4 R25 E32-TC200BR E32-TC200B4R Mounting holes Two 2.2 dia. Two, 4.4 dia. countersinks on one side (aluminum) 1 dia. 4.5 7 1 2 5 12 E32-TC200F R10 E32-TC200F4 R10 E32-TC200FR E32-TC200F4R 90 (40)* 3.2 11 Heat-shrinkable tube 3 dia. (SUS303) M3×0.5 (brass/nickel plating) Width 5.5, thickness 1.8 (nickel-plated brass) Washer (nickel-plated brass) 1 dia. Sensing surface: 0.5 dia. 2.8 3 dia. 2 30 35 E39-F9: Included 40 2,000 * ( ): E32-TC200B4/E32TC200B4R E32-T14L R25 E32-T14LR Stainless-steel tube 0.9 dia. max. (SUS304) 90 (40)* 2.2 dia. 2,000 Note: 1. Set of two symmetrical parts. 2. Mounting screws (countersunk screw M2 × 8 4 pcs) included 2.5 Width 7, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) Stainless-steel tube 1.2 dia. max. (SUS304) E39-F9: Included 2.5 M4×0.7 (coarse thread) (brass/nickel plating) Sensing surface: 1 dia. 11 2,000 * ( ):E32-TC200F4/E32TC200F4R Sensing surface 12 2,000 2.2 dia. Through-beam Fiber Units Through-beam models consist of two parts: an emitter and a receiver. Flexible Break-resistant Fluororesin coating R@ Standard Cutting free (Cutter provided) Standard Standard/Flexible Models E32-T24 R10 E32-T24R E32-T15Y R25 E32-T15YR 2 dia. (SUS304) Stainless-steel tube 1 dia. max. 4 Heat-shrinkable tube 1.4 dia. 1 dia. (aluminum) 3 Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on both sides Sensing surface Sensing surface 1.25 2.2 dia. E39-F9: Included 15 15 8 5.5 12 35 2,000 7.5 2.5 15 2,000 Note: 1. Set of two symmetrical parts. 2. Mounting screws (countersunk screw M2 × 8 4 pcs) included E32-T25Y R10 E32-T25YR E32-T15Z R25 E32-T15ZR (aluminum) 3 Sensing surface 2 Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on one side Sensing surface 3 1 dia. 8 7 4.5 E32-T25Z R10 E32-T25ZR 7 2,000 15 2,000 Note: 1. Set of two symmetrical parts. 2. Mounting screws (countersunk screw M2 × 8 4 pcs) included 2.2 dia. 7.5 2.5 5 12 2 1.5 4 5.5 E39-F9: Included 2.5 Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on both sides (aluminum) Note: 1. Set of two symmetrical parts. 2. Mounting screws (countersunk screw M2 × 8 4 pcs) included Sensing surface Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on one side 3 1 dia. (aluminum) 4.5 1 E39-F9: Included 2.5 5 12 2,000 Note: 1. Set of two symmetrical parts. 2. Mounting screws (countersunk screw M2 × 8 4 pcs) included Mounting hole dimensions (recommended) Minimum bending radius unbendable B Sensing head Minimum bending radius A F <Screw-mounting Model> Outer diameter of fiber unit (Unit:mm) M3 3 F dimensions +0.5 0 dia. M4 4 +0.5 0 dia. M6 6 +0.5 0 dia. Flexible Break-resistant M14 +1 14 0 dia. Outer diameter of fiber unit F dimensions Outer diameter of fiber unit F dimensions (Unit:mm) 1 dia. 1.5 dia. 2 dia. 3 dia. +0.2 0 +0.2 0 +0.2 0 +0.2 0 1.2 dia. 1.7 dia. 2.2 dia. 3.2 B unbendable (except E32-C11N, E32-C31N and E32-CC200) 1 0 (E32-C11N, E32-C31N, E32-CC200R) 4 0 4 10 25 30 35 40 10 10 10 10 10 10 dia. R4 R10 3.5 dia. 4 +0.5 0 dia. 4 dia. 5 dia. 6 dia. +0.5 0 +0.5 0 +0.5 0 4.5 dia. 5.5 dia. 6.5 dia. Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia. R@ Standard (Unit:mm) A Minimum bending radius Type Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia. <Cylindrical Model> Fluororesin coating R25 R30 R35 R40 41 Flexible Fluororesin coating R@ Standard Cutting free (Cutter provided) Standard Models Break-resistant/Coated Models E32-T11 E32-T11U Break-resistant E32-T21 Width 7, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) M4×0.7 (brass/nickel plating) Protective tube M2.6×0.45 3.2 Protective tube 2.2 dia. 1 dia. E39-F9: Included 15 15 3.3 Width 5.5, thickness 1.8 (nickel-plated brass) Washer (nickel-plated brass) M3×0.5 (brass/nickel plating) 14 Sensing surface: 1 dia. 2.5 2,000 11 Sensing surface: 0.5 dia. 2,000 E32-T221B E32-T12B Sensing surface: 0.5 dia. Sensing surface: 1 dia. 2.4 dia. 3 dia. (brass/nickel plating) 3 17 11 14 E32-T15XB 1.5 dia. (brass/nickel plating) 12 1 dia. E39-F9: Included 2,000 (aluminum) 2.2 dia. 5.5 8 1.5 2.5 3 2,000 1 dia. Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on both sides Sensing surface: 1 dia. E39-F9: Included 10 Heat-shrinkable tube 22 2,000 E32-T22B Sensing surface: 0.5 dia. 1.4 dia. 2 dia. (SUS303) 2.2 dia. 7.5 15 2,000 Note: 1. Set of two symmetrical parts. 2. Mounting screws (countersunk screw M2 × 8 4 pcs) included E32-T25XB Sensing surface: 0.5 dia. Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on one side (aluminum) 1 dia. 4.5 7 1 E39-F9: Included 5 2 2.5 12 2,000 Note: 1. Set of two symmetrical parts. 2. Mounting screws (countersunk screw M2 × 8 4 pcs) included 42 Through-beam Fiber Units Through-beam models consist of two parts: an emitter and a receiver. Flexible Special-beam Models Long-distance/High-power Models E32-T17L E32-T14 R25 Break-resistant R25 Sensing surface Lens (PMMA) 4.4 dia. M14×1 (ABS) Sensing surface lens diameter: 10 dia. (PMMA) Fluororesin coating Heat-resistant ABS 8.2 8 R3.5 Two, 3.2 dia. mounting holes 2.2 dia. 8 10.5 7 10±0.2 2.5 23 9.2 42 E32-T12L R25 Sensing surface: 1.4 dia. M4×0.7 (brass/nickel plating) 2.4 dia. 3 dia. (brass/nickel plating) 2.2 dia. 11 14 2.2 dia. 11 2,000 14 2,000 E32-T22L R10 Sensing surface M3×0.5 (brass/nickel plating) 0.9 dia. Width 5.5, thickness 1.8 (nickel-plated brass) Washer (nickel-plated brass) 1 dia. 11 R10 2 dia. (SUS304) Sensing surface 0.9 dia. Heat-shrinkable tube 1.8 dia. (2) E39-F9: Included (1.7) 2.5 R25 3 3 3.2 2,000 Sensing surface: 1.4 dia. Width 7, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) M2.6×0.45 11.2 16 25.2 10,000 E32-T21L Nitrile rubber Width 19, thickness 5 (aluminum) 2.2 dia. E32-T11L R@ Standard Cutting free (Cutter provided) E39-F9: Included 17 22 2,000 Mounting hole dimensions (recommended) 1 dia. 12 2,000 Minimum bending radius unbendable B Sensing head Minimum bending radius A F <Screw-mounting Model> Outer diameter of fiber unit (Unit:mm) M3 3 F dimensions +0.5 0 dia. M4 4 +0.5 0 dia. M6 6 +0.5 0 dia. Flexible Break-resistant M14 +1 14 0 dia. Outer diameter of fiber unit F dimensions Outer diameter of fiber unit F dimensions (Unit:mm) 1 dia. 1.5 dia. 2 dia. 3 dia. +0.2 0 +0.2 0 +0.2 0 +0.2 0 1.2 dia. 1.7 dia. 2.2 dia. 3.2 B unbendable (except E32-C11N, E32-C31N and E32-CC200) 1 0 (E32-C11N, E32-C31N, E32-CC200R) 4 0 4 10 25 30 35 40 10 10 10 10 10 10 dia. R4 R10 3.5 dia. 4 +0.5 0 dia. 4 dia. 5 dia. 6 dia. +0.5 0 +0.5 0 +0.5 0 4.5 dia. 5.5 dia. 6.5 dia. Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia. R@ Standard (Unit:mm) A Minimum bending radius Type Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia. <Cylindrical Model> Fluororesin coating R25 R30 R35 R40 43 Through-beam Fiber Units Through-beam models consist of two parts: an emitter and a receiver. Flexible Special-beam Models Ultracompact/Thin-sleeve Models E32-T33-S5 E32-T223R Sensing surface 0.5 dia. 1 dia. 5 E32-T334-S5 5 10 12 3 dia. (SUS303) Heat-shrinkable tube 1 dia. 1 dia. 0.22 dia. Fiber Attachment* 20 E39-F9: Included 1,000 R10 Sensing surface 0.1 dia. Heat-shrinkable tube 0.25 dia. 12 20 3 dia. (SUS303) Fiber Attachment* 12 10 5 1 dia. Heat-shrinkable tube 10 2,000 R10 R@ Standard 3 dia. (SUS303) 0.5 dia. E39-F9: Included Sensing surface 0.125 dia. Fluororesin coating R10 Sensing surface 0.25 dia. 1 dia. (stainless steel) 10 E32-T333-S5 Break-resistant Cutting free (Cutter provided) 20 1,000 1,000 *The Fiber Attachment is attached with adhesive and cannot be removed. *The Fiber Attachment is attached with adhesive and cannot be removed. Special-beam Models Fine-beam (narrow vision field) Models E32-T22S E32-T24S R10 R10 1.8 0.4 Sensing surface 1.7 dia. 3 dia. (brass/nickel plating) 2.2 dia. (brass/nickel plating) 11 17.6 3.5 dia. 2.2 dia. 3.2 2,000 15 E39-L83 Mounting Bracket (SUS) (provided) 3.2 3 10 20.5 2,000 2 dia. 2 Sensing surface Special-beam Models Area-sensing Models E32-T16W R10 E32-T16WR 5 E32-M21 M3×0.35 (SUS303) 23 18 Sensing surface (3×30)(PMMA) Width 5.5, thickness 1.8 (nickel-plated brass) Washer (nickel-plated brass) 12 18.5 R25 Silicon tube * Four, 1 dia. *One set of silicon tubes is black and the other set is gray. Usethis difference to distinguish between the emission and reception sides. 69 65 45 28 11 (ABS) Two, 3.2 dia. mounting holes with two, 6 dia. countersinks 2.2 dia. 44 2,000 2,000 23 Flexible Fluororesin coating R@ Standard Cutting free (Cutter provided) Special-beam Models Area-sensing Models E32-T16P R10 E32-T16PR E32-T16 R25 Mounting bracket (Zinc-plated iron) provided Two, 3.2 dia. mounting holes with two, 6 dia. countersinks on both sides 14.5 10.7 4 4 7 Sensing surface (2×11) (PMMA) 19 27 Break-resistant 20 (Heat-resistant ABS) 20 15.5 8.4 3 2,000 (Heat-resistant ABS) 2.2 dia. 25 *Provided with stickers with slits of width 0.5 and 1 mm (2 of each). E32-T16J R10 E32-T16JR 2-M3 20 58 2 Receiver Sensing surface (2×11) (PMMA) 43.2 8.85 Emitter 32.5 2,000 17.8 14.5 10.7 2.2 dia. 3.3 2 4 33 4 27 Sensing surface (2×10) (PMMA) 6 dia. 7 *Provided with stickers with slits of width 0.5 and 1 mm (2 of each). 19 (ABS) Two, 3.2 dia. mounting holes with two, 6 dia. countersinks on both sides 2.2 dia. 2,000 Mounting hole dimensions (recommended) Minimum bending radius unbendable B Sensing head Minimum bending radius A F <Screw-mounting Model> Outer diameter of fiber unit (Unit:mm) M3 3 F dimensions +0.5 0 dia. M4 4 +0.5 0 dia. M6 6 +0.5 0 dia. Flexible Break-resistant M14 +1 14 0 dia. Outer diameter of fiber unit F dimensions Outer diameter of fiber unit F dimensions (Unit:mm) 1 dia. 1.5 dia. 2 dia. 3 dia. +0.2 0 +0.2 0 +0.2 0 +0.2 0 1.2 dia. 1.7 dia. 2.2 dia. 3.2 B unbendable (except E32-C11N, E32-C31N and E32-CC200) 1 0 (E32-C11N, E32-C31N, E32-CC200R) 4 0 4 10 25 30 35 40 10 10 10 10 10 10 dia. R4 R10 3.5 dia. 4 +0.5 0 dia. 4 dia. 5 dia. 6 dia. +0.5 0 +0.5 0 +0.5 0 4.5 dia. 5.5 dia. 6.5 dia. Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia. R@ Standard (Unit:mm) A Minimum bending radius Type Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia. <Cylindrical Model> Fluororesin coating R25 R30 R35 R40 45 Through-beam Fiber Units Through-beam models consist of two parts: an emitter and a receiver. Flexible Environment-resistant Models Heat-resistant Models E32-T51 R35 E32-T54 M4×0.7 (brass/nickel plating) Width 7, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) Sensing surface 1.5 dia. Break-resistant Fluororesin coating R@ Standard Cutting free (Cutter provided) 2.2 dia. R35 Sensing surface 2.45 3 dia. (SUS303) 2.2 dia. 2 dia. 2.85 dia. 1 25 15 17 Note: The maximum allowable temperature is 150°C. The maximum allowable temperature for continuous operation is 130°C. E32-T81R-S R10 Width 7, thickness 2.4 (SUS304) Washer (SUS) Note: The maximum allowable temperature is 150°C. The maximum allowable temperature for continuous operation is 130°C. Protective tube Fluororesin tube 2 dia. M2.6×0.45 4 dia. 4 dia. 2.2 dia. Note: The maximum allowable temperatures for sections A and B are 200°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *), however, must stay within the Amplifier Unit's operating temperature range. * (75) 20 10 2,000 30(B) A E32-T84S-S E32-T61-S R25 30 2,000 * 3 dia. 4 dia. *2 3 20 Note: The maximum allowable temperatures for sections A and B are 200°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *), however, must stay within the Amplifier Unit's operating temperature range. 3 dia. (SUS303) Sensing surface Lens (2 dia.) 10 2.2 dia. *1 30 2,000 25(B) A 3.5 dia. 12 2.8 dia. flexible tubes (SUS304) 4 dia. M2.6×0.45 Flexible tube: 2.9 dia. (stainless steel) 90° 30 max. 6 M4×0.7 (SUS303) Width 7, thickness 2.4 (SUS304) Washer (SUS) 2.2 dia. 4 dia. 4 dia. R25 Sensing surface 1 dia. 25(B) A 12 14.2 R5 2,000 M4×0.7 (SUS303) Sensing surface 0.7 dia. 3 20 45 2,000 *2 The diameter is 6 mm if the fiberlength exceeds 10 m. Note: The maximum allowable temperatures for sections A and B are 200°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *1), however, must stay within the Amplifier Unit's operating temperature range. Environment-resistant Models Chemical-resistant Models E32-T11F E32-T12F R4 lens diameter: 3.7 mm 7.2 dia. (PFA) R40 nut (PFA) 2.2 dia. (Fluororesin) Sensing surface Lens 4 dia. 10 5 dia. (Fluororesin) 4 dia. 2.2 dia. R3.6 (10 19.8 .7) 35 3 10 2,000 20 2,000 E32-T14F E32-T51F R40 5 dia. (Fluororesin) 4 dia. 2.2 dia. R40 Sensing surface lens diameter: 3.7 dia. 4.5 5 dia. (Fluororesin) 2.2 dia. 20 2,000 21 2,000 E32-T81F-S 100 100 R10 6 dia. Sensing surface: 3.7 dia PFA cover (R6) Protective tube 2 dia. (PFA tube) 4 dia. (70) (0.8) 2.2 dia. * 2,000 30 A 46 100 30(B) Note: The maximum allowable temperatures for sections A and B are 200°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *), however, must stay within the Amplifier Unit's operating temperature range. Flexible Environment-resistant Models Vacuum-resistant Models E32-T51V E32-T54V R30 Break-resistant Fluororesin coating R30 8 4 Width 8 (SUS304) Washer (SUS304) M4×0.7 (Aluminum) M2.6×0.45 4 dia. 4 dia. 3 dia. 2.2 dia. Sensing surface: 1.15 dia. M2.6×0.45 3 12 1,000 15 Connected to flange (vacuum side) 4 dia. 2.2 dia. 3 dia. 3 dia. (SUS304) Sensing surface 1.15 dia. R@ Standard Cutting free (Cutter provided) 4.5 Connected to flange (vacuum side) 3 20 5 dia. 4 dia. R9 18 4 26 1,000 (30) 26 (3) E32-T84SV 3 dia. (SUS304) E39-F1V Sensing surface: 2 dia. R25 12 14.2 0.5 dia. hole 1,000 8.9 M2.6×0.45 Effective depth: 3.8 Spot-facing depth: 0.9 4 dia. 12 Connected to flange (vacuum side) 3.5 dia. 30 max. 6 3 dia. 90° Flexible tube: (stainless steel) 2.9 dia. 4 dia. 6 2.2 dia. 4 dia. Material: Aluminum for body and optical glass for the lens itself. R5 26 E32-VF4 24 36 dia. Four, 10 dia. 49 8 E32-VF1 80 70 dia. 44 dia. (96) (63) 10 5 22 30 (23) 22 20 dia. 19 M14×2 45° 6 (33.53) 80 Flange Flange V40 O-ring 90 dia. One nut One spring washer Two, connectors V15 O-ring Note 1. Perform mounting so that the V15 O-ring is on the atmospheric-pressure side of the vacuum chamber wall. 2. Mounting-hole cutout dimensions: 14.5 dia. ±0.2 mm Note 1. Perform mounting so that the V40 O-ring is on the atmospheric-pressure side of the vacuum chamber wall. 2. Mounting-hole cutout dimensions: 38 dia. ±0.5 mm E32-T10V-2M E39-L54V R25 4.5 8 4.1 2.2 dia. 4 23 15 2,000 Material: Stainless steel (SUS304) Mounting hole dimensions (recommended) 0.5 4.1 Minimum bending radius unbendable B Sensing head Minimum bending radius A F <Screw-mounting Model> Outer diameter of fiber unit (Unit:mm) M3 3 F dimensions +0.5 0 dia. M4 4 +0.5 0 dia. M6 6 +0.5 0 dia. Flexible Break-resistant M14 +1 0 14 dia. Fluororesin coating R@ Standard (Unit:mm) A Minimum bending radius B unbendable (except E32-C11N, E32-C31N and E32-CC200) 1 0 (E32-C11N, E32-C31N, E32-CC200R) 4 0 4 10 25 30 35 40 10 10 10 10 10 10 Type Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia. <Cylindrical Model> Outer diameter of fiber unit F dimensions Outer diameter of fiber unit F dimensions (Unit:mm) 1 dia. 1.5 dia. 2 dia. 3 dia. +0.2 0 +0.2 0 +0.2 0 +0.2 0 1.2 dia. 1.7 dia. 2.2 dia. 3.2 dia. R4 R10 3.5 dia. 4 +0.5 0 dia. 4 dia. 5 dia. 6 dia. +0.5 0 +0.5 0 +0.5 0 4.5 dia. 5.5 dia. 6.5 dia. Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia. R25 R30 R35 R40 47 Fiber Units with Reflective Sensors Flexible E32-D11N Model display tube E32-DC200 E32-D11R R@ Standard Two, 2.2 dia. R25 M6×0.75 (ADC) Sensing surface: Two, 1 dia. (45) Fluororesin coating Cutting free (Cutter provided) Standard Models Standard/Flexible Models Sensing surface: Two, 1 dia. Break-resistant Width 10, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) 4 dia. 2,000 Two, 2.2 dia. M6×0.75 (brass/nickel plating) 11 15.7 4.7 10 3 4.8 17 2,000 8 M6 nuts (brass/nickel plating) Washer (nickel -plated iron) included (2 of each) 10 12 dia. E32-D211 R10 E32-D211R E32-DC200E E32-D21R M4×0.7 (SUS303) Width 5.5, thickness 1.8 (nickel-plated brass) Washer (nickel-plated brass) Two, 1 dia. Two, 1 dia. 15 E39-F9: Included 2,000 2.5 E39-F9: Included 3 3.2 M3×0.5 (SUS304) Sensing surface Two, 0.5 dia. Width 7, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) Sensing surface Two, 0.5 dia. R10 11 2,000 E32-D12 R25 E32-D12R E32-D22 R10 E32-D22R Sensing surface Two, 1 dia. 3 dia. (SUS304) 15 Heat-shrinkable tube Two, 2.2 dia. Sensing surface Two, 0.5 dia. 2.7 dia. 3 dia. (brass/nickel plating) Two, 1 dia. 3 135 2,000 E32-D15X R25 E32-D15XR E32-D25X R10 E32-D25XR Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on both sides Sensing surface: (aluminum) Two, 1 dia. Two, 2.2 dia. 7.5 10 2.5 3 Sensing surface 2-0.5 dia. 5 2.5 2,000 12 2,000 15 Note: Mounting screws (countersunk screw M2 × 8 2 pcs) included Note: Mounting screws (countersunk screw M2 × 8 2 pcs) included E32-DC200B R25 E32-DC200B4 R25 E32-DC200BR E32-DC200B4B Sensing surface: Two, 1 dia. M6×0.75 (brass/nickel plating) (fine thread) Stainless-steel tube 2.5 dia. max. (SUS304) Width 10, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) E32-DC200F R10 E32-DC200F4 R10 E32-DC200FR E32-DC200F4R 48 90 (40 40)* 17 2,000 * ( ):E32-DC200B4/E32-DC200B4R M3×0.5 (SUS304) Stainless-steel tube 1.2 dia. max. (SUS304) Width 5.5, thickness 1.8 (nickel-plated brass) Washer (nickel-plated brass) Sensing surface Two, 0.5 dia. Two, 2.2 dia. 5.2 Two, 1 dia. E39-F9: Included 5.5 2 7.5 Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on one side (aluminum) 8 1.5 2.5 E39-F9: Included 2,000 15 2.5 Two, 1 dia. E39-F9: Included 90 (40 40)* 11 2,000 * ( ):E32-DC200F4/E32-DC200F4R Flexible Break-resistant Fluororesin coating R@ Standard Cutting free (Cutter provided) E32-D14L R25 E32-D14LR (SUS304) Heat-shrinkable tube Two, 2.2 dia. E32-D24 R10 E32-D24R Stainless-steel tube 2 dia. max. 3 dia. (SUS304) Heat-shrinkable tube Two, 1 dia. 5.7 1.25 2 6 dia. 15 12 30 35 Light baffle E39-F9: Included 15 12 35 2,000 2,000 Sensing surface Light baffle Sensing surface E32-D15Y R25 E32-D15YR 2.8 E32-D25Y R10 E32-D25YR 2.4 (aluminum) Sensing surface 2 Mounting holes Two, 2.2 dia. Two, 4.4 dia. countersinks on both sides Two, 2.2 dia. Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on one side Sensing surface 7.5 10 7.5 2.5 E32-D15Z R25 E32-D15ZR Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on both sides (aluminum) Sensing surface Note: Mounting screws (countersunk screw M2 × 8 2 pcs) included E32-D25Z R10 E32-D25ZR Sensing surface 2 10 8 1.2 0.9 E39-F9: Included 5.5 5 2.5 2,000 2,000 12 Note: Mounting screws (countersunk screw M2 × 8 2 pcs) included Mounting hole dimensions (recommended) Two, 1 dia. 3 7.5 15 Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on one side (aluminum) Two, 2.2 dia. 4 2.5 2,000 12 2,000 Note: Mounting screws (countersunk screw M2 × 8 2 pcs) included 2.2 1.4 7.5 5 2.5 15 Two, 1 dia. E39-F9: Included 5.5 8 3 (aluminum) 1.4 2.3 3 Note: Mounting screws (countersunk screw M2 × 8 2 pcs) included Minimum bending radius unbendable B Sensing head Minimum bending radius A F <Screw-mounting Model> Outer diameter of fiber unit (Unit:mm) M3 3 F dimensions +0.5 0 dia. M4 4 +0.5 0 dia. M6 6 +0.5 0 dia. Flexible Break-resistant M14 +1 14 0 dia. Outer diameter of fiber unit F dimensions Outer diameter of fiber unit F dimensions (Unit:mm) 1 dia. 1.5 dia. 2 dia. 3 dia. +0.2 0 +0.2 0 +0.2 0 +0.2 0 1.2 dia. 1.7 dia. 2.2 dia. 3.2 B unbendable (except E32-C11N, E32-C31N and E32-CC200) 1 0 (E32-C11N, E32-C31N, E32-CC200R) 4 0 4 10 25 30 35 40 10 10 10 10 10 10 dia. R4 R10 3.5 dia. 4 +0.5 0 dia. 4 dia. 5 dia. 6 dia. +0.5 0 +0.5 0 +0.5 0 4.5 dia. 5.5 dia. 6.5 dia. Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia. R@ Standard (Unit:mm) A Minimum bending radius Type Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia. <Cylindrical Model> Fluororesin coating R25 R30 R35 R40 49 Fiber Units with Reflective Sensors Flexible Fluororesin coating R@ Standard Cutting free (Cutter provided) Standard Models Break-resistant/Coated Models E32-D11 E32-D11U Break-resistant M6×0.75 (brass/nickel plating) Sensing surface Two, 1 dia. Width 10, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) 15 5.2 Two, 2.2 dia. Protective tube 17 7 2,000 E32-D21B E32-D21 M4×0.7 (SUS303) Width 7, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) Sensing surface Two, 0.5 dia. Sensing surface Four, 0.25 dia. M3×0.5 (brass/nickel plating) Width 5.5, thickness 1.8 (nickel-plated brass) Washer (nickel-plated brass) Two, 1 dia. Two, 1 dia. Protective tube E39-F9: Included 3 3.2 15 15 2.5 E39-F9: Included 11 2,000 2,000 Enlarged illustration of sensing surface Two 0.25 dia. emission fibers Two, 0.25 dia. reception fibers E32-D221B E32-D22B Sensing surface Two, 0.5 dia. 3 dia. (brass/nickel plating) 1.5 dia. (SUS304) Sensing surface Four, 0.25 dia. Two, 1 dia. 1 dia. E39-F9: Included 15 Brancher (ABS): 3.5 dia. Fiber Attachment* 15 2,000 15 2,000 100 *The Attachment is attached with adhesive and cannot be removed. Enlarged illustration of sensing surface Two 0.25 dia. emission fibers Two, 0.25 dia. reception fibers E32-D15XB Sensing surface: Two, 1 dia. E32-D25XB Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on both sides (aluminum) 3 7.5 15 E39-F9: Included 5 2 2,000 Note: Mounting screws (countersunk screw M2 × 8 2 pcs) included 50 Two, 1 dia. 5.5 8 1.5 2.5 Two, 2.2 dia. mounting holes with two, 4.4 dia. countersinks on one side (aluminum) 7.5 10 2.5 Sensing surface: Two, 1 dia. Two, 2.2 dia. 2.5 12 2,000 Note: Mounting screws (countersunk screw M2 × 8 2 pcs) included Flexible E32-D11L Sensing surface Lens Two, 5.8 dia lenses 9 R@ Standard R25 M6×0.75 (brass/nickel plating) Two, 3.2 dia. mounting holes Two, 6 dia. countersinks on both sides (aluminum) Fluororesin coating Cutting free (Cutter provided) Special-beam Models Long-distance/High-power Models E32-D16 Break-resistant Sensing surface Two, 1.4 dia. Width 10, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) Two, 2.2 dia. 4 dia. 8.5 Two, 2.2 dia. 17.5 3 5.2 22 E32-D21L R10 2,000 E32-D22L M4×0.7 (brass/nickel plating) Width 7, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) Sensing surface Two, 0.9 dia. R10 Sensing surface 2.7 dia. Two, 0.9 dia. Two, 1 dia. 15 3 dia. (brass/nickel plating) 2,000 15 2,000 Two, 1 dia. E39-F9: Included 3 E39-F9: Included 3 3.2 2,000 20 6.5 11 Special-beam Models Ultracompact/Thin-sleeve Models E32-D33 E32-D331 R4 Stainless-steel tube 0.8 dia. max. 3 dia. (SUS303) Sensing surface Two, 0.25 dia. 15 Heat-shrinkable tube Stainless-steel tube 0.5 dia. max. Sensing surface Two, 0.125 dia. Two, 1 dia. 12 15 R4 2 dia. (SUS303) Irraxtube: 1.2 dia. Brancher: 3.5 dia. E39-F9: Included 15 15 2,000 35 2,000 15 100 Fiber Attachment* *The Attachment is attached with adhesive and cannot be removed. Mounting hole dimensions (recommended) Minimum bending radius unbendable B Sensing head Minimum bending radius A F <Screw-mounting Model> Outer diameter of fiber unit (Unit:mm) M3 3 F dimensions +0.5 0 dia. M4 4 +0.5 0 dia. M6 6 +0.5 0 dia. Flexible Break-resistant M14 +1 14 0 dia. Outer diameter of fiber unit F dimensions Outer diameter of fiber unit F dimensions (Unit:mm) 1 dia. 1.5 dia. 2 dia. 3 dia. +0.2 0 +0.2 0 +0.2 0 +0.2 0 1.2 dia. 1.7 dia. 2.2 dia. 3.2 B unbendable (except E32-C11N, E32-C31N and E32-CC200) 1 0 (E32-C11N, E32-C31N, E32-CC200R) 4 0 4 10 25 30 35 40 10 10 10 10 10 10 dia. R4 R10 3.5 dia. 4 +0.5 0 dia. 4 dia. 5 dia. 6 dia. +0.5 0 +0.5 0 +0.5 0 4.5 dia. 5.5 dia. 6.5 dia. Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia. R@ Standard (Unit:mm) A Minimum bending radius Type Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia. <Cylindrical Model> Fluororesin coating R25 R30 R35 R40 51 Fiber Units with Reflective Sensors Flexible Break-resistant Fluororesin coating Cutting free (Cutter provided) Special-beam Models Coaxial/Small-spot Models E32-C11N E32-C31N 1 dia. emission fibers 0.5 dia. emission fibers Two, 2.2 dia. Model display tube Sixteen, 0.265 dia. reception fibers Model display tube Two, 1 dia. Four, 0.25 dia. reception fibers (45) (45) 2,000 3 2,000 M6×0.75 (brass/nickel plating) 20.5 13.5 7 6 10 6.5 dia. 5.5 M6 nuts (brass/nickel plating) Washer (nickel-plated iron) included (2 of each) 5 10 8 12 dia. Note: The Emitter fiber is shown with a white line. M3 nuts (brass/nickel plating) Washer (brass/nickel plating) included (2 of each) E32-CC200 R25 E32-CC200R E32-D32L R25 M6×0.75 (brass/nickel plating) 1 dia. emission fibers Brancher (heat-resistant, ABS, black): 6 dia. Width 10, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) Two, 2.2 dia. 2.5 dia. 15 23 Sixteen, 0.25 dia. reception fibers R25 0.5 dia. emission fibers Two, 1 dia. 2 dia. (SUS303) 20 12 E39-F9: Included 25 R25 2,000 M3×0.5 (SUS303) Brancher (ABS resin):3.5 dia. Width 5.5, thickness 1.8 (nickel-plated brass) Washer (nickel-plated brass) 0.175 dia. emission fibers White markings:Emission side (heat-shrinkable tube) Two, 1.2 dia. 2 Two, 1 dia. 12 E39-F9: Included 22 2,000 Four, 0.25 dia. reception fibers 2.5 Note: There is a white line on the cable fiber that is inserted in the emitter-side port. Heat-shrinkable tube 3 dia. 15 Four, 0.25 dia. reception fibers 1,570 15 2,000 R25 Width 5.5, thickness 1.8 (nickel-plated brass) Washer (nickel-plated brass) Heat-shrinkable tube 400 Note: There is a yellow dotted line on the fiber that is inserted in the emitter-side port. E32-D32 M3×0.5 (SUS303) 0.5 dia. emission fibers Two, 2.2 dia. Sixteen, 0.265 dia. reception fibers 2,000 Note: There is a white line on the fiber that is inserted in the emitter-side port. E32-C41 3 dia. (SUS304) 1 dia. emission fibers 3 5.2 E39-F9: Included M3×0.5 (brass/nickel plating) 18 24 E32-C31 R@ Standard Note: There is a white line on the cable fiber that is inserted in the emitter-side port. E32-C42 R25 2 dia. (SUS303) Brancher 3 dia. (ABS resin): Irraxtube: 2.6 dia. 3.5 dia. 0.175 dia. emission fibers White markings: Emission side (heat-shrinkable tube) Two, 1.2 dia. Irraxtube: 2.6 dia. Six, 0.175 dia. reception fibers Six, 0.175 dia. reception fibers 15 17 (100) Fiber Attachment* 22 1,000 * The Fiber Attachment is attached with adhesive and cannot be removed. 52 15 15 22 (100) 2 Fiber Attachment* 1,000 * The Fiber Attachment is attached with adhesive and cannot be removed. Flexible Break-resistant Fluororesin coating R@ Standard Cutting free (Cutter provided) Special-beam Models Area-sensing Models E32-D36P1 25 2,000 5 10 Two, 2.2 dia. 15 2.5 Two, 3.2 dia. mounting holes ……… 2 Sensing surface: 32 × 0.265 dia. (emission and reception fibers in alternating arrangement) 10.85 5 (brass/nickel plating) Special-beam Models Retroreflective Fiber Units E32-R21 R10 (An E39-R3 Reflector is provided as an accessory.) E32-R16 R25 (An E39-R1 Reflector is provided as an accessory.) 27 15 Width 10, thickness 3 (polyacetal) Washer (NBR) M6×0.75 (ABS) Sensing surface Lends (PMMA) 7 Silicon tube 13 Two, 1 dia. 5 dia. 2.2 2.8 11 10 7.2 E39-F9: Included 14 Sensing surface Lends (PMMA) (6) 16 (ABS) 2,000 17.8 27.8 21.5 15.2 8 Two, 2.2 dia. Standard length: 2 m 17 21 22.5 Two, M3 set screws (provided) Mounting bracket E39-L4 (Zinc-plated iron) provided Mounting hole dimensions (recommended) Minimum bending radius unbendable B Sensing head Minimum bending radius A F <Screw-mounting Model> Outer diameter of fiber unit (Unit:mm) M3 3 F dimensions +0.5 0 dia. M4 4 +0.5 0 dia. M6 6 +0.5 0 dia. Flexible Break-resistant M14 +1 14 0 dia. Outer diameter of fiber unit F dimensions Outer diameter of fiber unit F dimensions (Unit:mm) 1 dia. 1.5 dia. 2 dia. 3 dia. +0.2 0 +0.2 0 +0.2 0 +0.2 0 1.2 dia. 1.7 dia. 2.2 dia. 3.2 B unbendable (except E32-C11N, E32-C31N and E32-CC200) 1 0 (E32-C11N, E32-C31N, E32-CC200R) 4 0 4 10 25 30 35 40 10 10 10 10 10 10 dia. R4 R10 3.5 dia. 4 +0.5 0 dia. 4 dia. 5 dia. 6 dia. +0.5 0 +0.5 0 +0.5 0 4.5 dia. 5.5 dia. 6.5 dia. Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia. R@ Standard (Unit:mm) A Minimum bending radius Type Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia. <Cylindrical Model> Fluororesin coating R25 R30 R35 R40 53 Fiber Units with Reflective Sensors Flexible E32-L16-N R10 R@ Standard Two, 3.2 dia.mounting holes with two, 6 dia. Countersinks Two, 2.2 dia. (ABS) 3.5 5.5 11 R25 Sensing surface Two, 3.2 dia. mounting holes with two, 6 dia. Countersinks on one side Fluororesin coating Cutting free (Cutter provided) Special-beam Models Convergent-reflective Models E32-L24S Break-resistant 14 10.6 Two, 1 dia. Model display tube 0.95 Sensing surface 3.5 2 2.7 7 14 (45) 7 6.8 2,000 2,000 20.5 E39-F9: Included 3.8 2.5 (PVC) E32-L24L E32-L25L R10 Sensing distance R10 Sensing surface Two, 3.2 dia. Sensing surface 4 Sensing distance 1.5 3.6 3.3 18 Side-view prism (PC) 4 Two, 3.2 dia. mounting holes with two, 6 dia. countersinks on both sides 4 6 20 18 6 E39-F9: Included E39-F9: Included 16 Two, 1 dia. 6.5 Two, 1 dia. 6.5 (Polycarbonate) (Polycarbonate) 2,000 E32-L25 Two, 3.2 dia. mounting holes with two, 6 dia. countersinks on both sides E32-L25A R25 20 10 Sensing surface 5 20 R25 20 10 Sensing distance 5 6.5 6.5 2,000 Sensing surface Sensing distance 6.5 Two, 2.2 dia. 20 6.5 (Heat-resistant ABS) 2,000 (Heat-resistant ABS) Two, 3.2 dia. mounting holes with two, 6 dia. countersinks on one side Two, 3.2 dia. mounting holes with two, 6 dia. countersinks on one side 2,000 Two, 2.2 dia. Note: There is a white line on the fiber that is inserted in the emitter-side port. 54 Note: There is a white line on the fiber that is inserted in the emitter-side port. Flexible Fluororesin coating R@ Standard Cutting free (Cutter provided) Special-beam Models Convergent-reflective Models E32-L86 Break-resistant R25 Two, 3.2 dia. mounting holes with two, 6 dia. countersinks on one side 27 5.5 22.5 Note: The maximum allowable temperatures for sections A and B are 200°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *), however, must stay within the Amplifier Unit's operating temperature range. Two, 2.8 dia. flexible tubes (SUS304) Two, 4 dia. 4 dia. 8.9 18 5 (max.) (SUS304) 19 Sensing surface * 7 2,000 33.5 25(B) A E32-L64 R25 Mounting holes Two, 3.4 dia. Two, 6.3 dia. countersinks Sensing surface 5 Two, 4 dia. 14 Note: The maximum allowable temperatures are 300°C for section A and 110°C for section B (section inserted into the Amplifier Unit). Two, 2.9 dia. flexible tubes (stainless steel) 10.7 6.5 (SUS304) Mounting holes 2.2 dia. 8.9 18 2-M3 18 25 2,000 30(B) A E32-A10 6.5±0.1 4 dia. R25 Mounting holes Two, 3.2 dia. Two, 6.2 dia. countersinks Sensing surface 4 Model display tube: 3.3 dia. (45) 8.4 6 16.5 Mounting holes 8 Two, 2.2 dia. 7±0.1 3.5 2-M3 (ABS) 2 6 4 7 21 2,000 Mounting hole dimensions (recommended) Minimum bending radius unbendable B Sensing head Minimum bending radius A F <Screw-mounting Model> Outer diameter of fiber unit (Unit:mm) M3 3 F dimensions +0.5 0 dia. M4 4 +0.5 0 dia. M6 6 +0.5 0 dia. Flexible Break-resistant M14 +1 14 0 dia. Outer diameter of fiber unit F dimensions Outer diameter of fiber unit F dimensions (Unit:mm) 1 dia. 1.5 dia. 2 dia. 3 dia. +0.2 0 +0.2 0 +0.2 0 +0.2 0 1.2 dia. 1.7 dia. 2.2 dia. 3.2 B unbendable (except E32-C11N, E32-C31N and E32-CC200) 1 0 (E32-C11N, E32-C31N, E32-CC200R) 4 0 4 10 25 30 35 40 10 10 10 10 10 10 dia. R4 R10 3.5 dia. 4 +0.5 0 dia. 4 dia. 5 dia. 6 dia. +0.5 0 +0.5 0 +0.5 0 4.5 dia. 5.5 dia. 6.5 dia. Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia. R@ Standard (Unit:mm) A Minimum bending radius Type Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia. <Cylindrical Model> Fluororesin coating R25 R30 R35 R40 55 Fiber Units with Reflective Sensors Flexible R35 Fluororesin coating R@ Standard Cutting free (Cutter provided) Environment-resistant Models Heat-resistant Models E32-D51 Break-resistant M6×0.75 (brass/nickel plating) Width 10, thickness 2.4 (nickel-plated brass) Washer (nickel-plated iron) Sensing surface Two, 1.5 dia. Two 2.2 dia. 4.9 3 3.1 13 17 2,000 Note: The maximum allowable temperature is 150°C. The maximum allowable temperature for continuous operation is 130°C. E32-D81R-S R10 E32-D81R R10 Using the E32-D81R-S Using the E32-D81R Note 1. The maximum allowable temperatures for sections A and B are 200°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *), however, must stay within the Amplifier Unit's operating temperature range. M4×0.7 M6×0.75 (SUS303) Sensing surface 1.2 dia. Width 10, thickness 2.4 (SUS303) Washer (SUS) Protective tube SUS303 Fluororesin tube 2.2 dia. 2.2 dia. 4.5 8.5 3 2 (70) 5 * 5 20 * 2,000 A 6.4 29.5(B) 25(B) E32-D61-S R25 E32-D61 R25 Using the E32-D61-S Using the E32-D61 Note 1. The maximum allowable temperatures for sections A and B are 350°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *1), however, must stay within the Amplifier Unit's operating temperature range. Sensing surface 1.4 dia. M6×0.75 (SUS303) Hexagonal caulking Width 10, thickness 2.4 (SUS303) Washer (SUS) M4×0.7 5 dia. *2 SUS316L 2. Order the Fiber Unit based on the Amplifier Unit. Use the E32-D61-S if the E3X-DA@-S, E3X-MDA@, or E3X-DAC@-S is used. Use 8 15 the E32-D61 if any other Amplifier is used. 2.2 dia. SUS flexible tube 3.5 dia. 4.5 8.5 3 2 20 5 *1 2,000 5 *3 6.4 *1 25(B) A 2. Order the Fiber Unit based on the Amplifier Unit. Use the E32-D81R-S if the E3XDA@-S, E3X-MDA@, or E3X-DAC@-S is used. Use the E32-D81R if any other Amplifier is used. 8 15 29.5(B) *2. The diameter is 6 dia. if the fiber length exceeds 10 m. *3. The diameter is 10 if the fiber length exceeds 10 m. E32-D73-S R25 E32-D73 R25 Sensing surface 1 dia. Using the E32-D73-S Using the E32-D73 Note 1. The maximum allowable temperatures for sections A, B, and C are 400°C, 300°C, and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *), however, must stay within the Amplifier Unit's operating temperature range. M4×0.7 (SUS303) Stainless-steel tube 1.25 dia. 2.5 dia. 1.65 dia. Width 7, thickness 2.4 (SUS304) Washer (SUS) SUS flexible tube 2.8 dia. 2.2 dia. 4 dia. Hexagonal caulking SUS316L 4.5 8.5 5 5 A 5 * 20 60 10 * 2,000 B 25(C) 2. Order the Fiber Unit based on the Amplifier Unit. Use the E32-D@-S if the E3X-DA@-S, E3X-MDA@, or E3XDAC@-S is used. Use the E32-D@ if any other Amplifier is used. 8 15 6.4 29.5(C) Environment-resistant Models Chemical-resistant Models E32-D12F E32-D14F R40 R40 7 dia. (fluororesin) 5 dia. 6 dia. (Fluororesin) 4.5 56 26 2,000 16 2,000 Two, 2.2 dia. Two, 2.2 dia. 100 Optical axis confirmation mark (red) 100 Flexible Break-resistant Fluororesin coating R@ Standard Cutting free (Cutter provided) Application-corresponding Fiber Units Label-detection Models E32-G14 R25 36.3 20 (ABS) 9.2 2,000 R1.6 R1.6 R3.5 Lens (PMMA) 24 3.2 10 Optical axis 9 Two, 2.2 dia. 4 1.6 1.6 23.5 9.4 8.4 Liquid-level Detection Models E32-D36T R4 Two, 2.2 dia. R10 Enlarged illustration of sensing surface 15 Emission side: Sixteen, 0.265 dia. 4 5 2 Eight, R0.5 5 11.4 20.4 23.45 2,000 Reception side: Sixteen, 0.265 dia. 13.25 5 4.4 E32-L25T R10 Sensing surface Sensing surface Lens two, 3.2 dia. (PC) 2.8 1.2 E39-F9: Included 16 (13) 15.2 Mounting holes 6 10 Two, 1 dia. (PC) 6 18 Mounting hole dimensions (recommended) 2,000 Minimum bending radius unbendable B Sensing head Minimum bending radius A F <Screw-mounting Model> Outer diameter of fiber unit (Unit:mm) M3 3 F dimensions +0.5 0 dia. M4 4 +0.5 0 dia. M6 6 +0.5 0 dia. Flexible Break-resistant M14 +1 14 0 dia. Fluororesin coating R@ Standard (Unit:mm) A Minimum bending radius B unbendable (except E32-C11N, E32-C31N and E32-CC200) 1 0 (E32-C11N, E32-C31N, E32-CC200R) 4 0 4 10 25 30 35 40 10 10 10 10 10 10 Type Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia. <Cylindrical Model> Outer diameter of fiber unit F dimensions (Unit:mm) 1 dia. 1.5 dia. 2 dia. 3 dia. +0.2 0 +0.2 0 +0.2 0 +0.2 0 1.2 dia. 1.7 dia. 2.2 dia. 3.2 dia. R4 R10 Outer diameter of fiber unit 3.5 dia. F dimensions 4 +0.5 0 dia. 4 dia. 5 dia. 6 dia. +0.5 0 +0.5 0 +0.5 0 4.5 dia. 5.5 dia. 6.5 dia. Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia. R25 R30 R35 R40 57 Fiber Units with Reflective Sensors Flexible Break-resistant Fluororesin coating R@ Standard Cutting free (Cutter provided) Application-corresponding Fiber Units Liquid-level Detection Models E32-A01 E32-A02 R4 R4 (ABS) (ABS) Two, 2.2 dia. Two, 2.2 dia. 14.5 17.8 4.5 3.3 1.7 (PBT) 4.2 (PMMA) (ABS) 20 Sensing surface (2 × 11)(PMMA) 5,000 27 7 3 12 4.5 Receiver 19.9 5,000 27 31.2 31.5 Optical axis Optical axis 21.5 Emitter E32-D82F1 E32-D82F2 R40 R40 Fiber connector 9 dia. (brass/nickel plating) 8 dia. 6 dia. (Fluororesin) Note: The maximum allowable temperatures for sections A and B are 200°C and 85°C, respectively. Two, 2.2 dia. *2 To the Amplifier Unit 27 7.2 Length of unbendable 350) *1 section: 150 (350 42 2,000 2,000 A B 1,500 mm from the tip *1.( ): E32-D82F2 *2.The 2-m section of optical fiber on the Amplifier-unit side is plastic and therefore allows free cutting. Models for Glass-substrate Alignment/Mapping E32-A08 R25 E32-A07E1 R25 E32-A07E2 R25 3.8 E32-L66 (SUS303) R25 Two, 3.2 dia. mounting holes with 6 dia. Countersinks on one side 10.7 6.5 Two, 2.2 dia. *1 (ABS) 18 14 4 2.2 dia. 12 Sensing surface 1.1 Two, 3.2 dia. mounting holes with two, 6 dia. countersinks *2 24.5 1 3.3 Sensing surface 21.7 5 7 4 dia. * 2,000 2,000 25(B) A 5 5.5 36 *1 The E32-A07E1/E32-A07E2 has a reception fiber and an emission fiber. Use the fiber with a model display tube (fiber with blue dotted line) as light emitting side. *2 E32-A08 : Countersinks on one side E32-A07E1/E32-A07E2 : Countersinks on both sides E32-A08H2 Two, 2.8 dia. flexible tubes (SUS304) Note: The maximum allowable temperatures for sections A and B are 300°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *), however, must stay within the Amplifier Unit's operating temperature range. R25 Note: The maximum allowable temperatures for sections A and B are 300°C and 110°C, respectively. Mounting holes Two, 3.4 dia. Two, 6.3 dia. countersinks 1.5 Sleeve (Aluminum) (5) 5 4 dia. 4 dia. 8.6 2-M3 6.5±0.1 2.2 dia. 18 8 Sensing surface 4 6.5 26 3,000 A 58 Mounting holes Flexible tube: Two, 2.9 dia (stainless steel) (SUS303) 10.7 30(B) Flexible Break-resistant Fluororesin coating R@ Standard Cutting free (Cutter provided) E32-A09 R25 E32-A09H R35 E32-A09H2 Sensing surface Lends 5 dia. Sensing surface Lends 5 dia. 9 R25 9 Two, 3.2 dia. mounting holes with two, 6 dia. countersinks on both sides (SUS303) Two, 2.8 dia. flexible tubes (SUS304) (aluminum) 24 8.9 * Two, 2.2 dia. 8.9 20 12 7 5 30 12 Two, 3.2 dia. mounting holes with two, 6 dia. countersinks on one side 7 23 2.2 dia. 4 dia. 2,000 2,000 A 28(B) Note: The maximum allowable temperatures for sections A and B are 300°C and 110°C, respectively. The section inserted into the Amplifier Unit (indicated by *), however, must stay within the Amplifier Unit's operating temperature range. Wafer-mapping Models E32-A03 E32-A03-1 0.4 R10 4.5 Stamp 3.2 (1 dia.) 10 Stamp (1 dia.) E39-F9: Included 3.5 3 4.3 17.6 11 3 dia. 3.4 1 dia. 3 dia. 2,000 20.5 1.8 Two, R1.6 3.2 2 10 E39-F9: Included 24.5 (brass/nickel plating) R1.6 Mounting holes Two, 3.4 dia 6.5 3 12.5 18.5 Sensing surface 2 dia. E39-L83 Mounting Bracket (SUS) (provided) 2,000 (brass/nickel plating) 13 Note 1. Use the stamped surface and its opposing surface as installation (reference) surfaces. 2. Set of two symmetrical parts. Sensing surface: 2 dia. Note: Use the stamped surface and its opposing surface as installation (reference) surfaces. E32-A04 R10 2 dia. (SUS303) E32-A04-1 E39-F9: Included 1 dia. R10 2 1 dia. 2 dia. 2 2 2 4 2,000 20.5 Stamp (1 dia.) 1.2 2.5 3.5 17 21 2,000 Mounting hole dimensions (recommended) (SUS303) 2 Note: Use the stamped surface and its opposing surface as installation (reference) surfaces. E39-F9: Included 2-M2 10 4 Sensing surface 1.2 dia. Sensing surface: 1.2 dia. 2 9 installation (reference) surfaces Note: Set of two symmetrical parts. Minimum bending radius unbendable B Sensing head Minimum bending radius A F <Screw-mounting Model> Outer diameter of fiber unit (Unit:mm) M3 3 F dimensions +0.5 0 dia. M4 4 +0.5 0 dia. M6 6 +0.5 0 dia. Flexible Break-resistant M14 +1 0 14 dia. Fluororesin coating R@ Standard (Unit:mm) A Minimum bending radius B unbendable (except E32-C11N, E32-C31N and E32-CC200) 1 0 (E32-C11N, E32-C31N, E32-CC200R) 4 0 4 10 25 30 35 40 10 10 10 10 10 10 Type Example: Head size of E32-TC200 is M4. Open the mounting holes with 4 to 4.5 dia. <Cylindrical Model> Outer diameter of fiber unit F dimensions Outer diameter of fiber unit F dimensions (Unit:mm) 1 dia. 1.5 dia. 2 dia. 3 dia. +0.2 0 +0.2 0 +0.2 0 +0.2 0 1.2 dia. 1.7 dia. 2.2 dia. 3.2 dia. R4 R10 3.5 dia. 4 +0.5 0 dia. 4 dia. 5 dia. 6 dia. +0.5 0 +0.5 0 +0.5 0 4.5 dia. 5.5 dia. 6.5 dia. Example: Head size of E32-T22 is 2 dia.. Open the mounting holes with 2.2 to 2.4 dia. R25 R30 R35 R40 59 Accessories Lens Units Lens Units E39-F1 Side-view Units E39-F2 M2.6×0.45 Effective depth: 3. Spot-facing depth 2.8 dia. 4 dia. 4 dia. 5.7 8.9 Material: Brass for the body and optical glass for the lens itself. 9.2 Material: Brass for the body and optical glass for the lens itself. Note: Two per set. Note: Two per set. Reflection Unit with Lens E39-F3 Two, 4 dia. M3 internally toothed washer Two, M3×3 Two, 3.2 dia. slotted-head set screws* 12 6.4 18 6.4 3 8±0.2 3.6 M3 × 6 angle-settingscrew 6.5 Material: Brass for the body and aluminum for the base. * Secure the fiber head with the slotted-head set screws. Do not insert a lens (E39-F1). 20.7 8.5 Lens Unit for Reflective Fiber Units E39-F3A Lens Unit for Reflective Fiber Units E39-F3A-5 M2×2 Allen-head set screw (for securing the fiber) Straight knurling 3 Lens surface (lens diameter: 3.7 mm) 13 2.1 dia. 23 Note: This is the Lens Unit for the E32-D32 and E32C42. Lens Unit for Reflective Fiber Units E39-F3B Lens surface (lens diameter: 3.7 mm) Material: Aluminum for body and optical glass for lens 2.1 dia. 5 dia. 4 dia. 6 dia.4 dia. Material: Aluminum for body and optical glass for lens. M2.6 Effective depth: 3.2 Spot-facing depth: 0.9 16.5 M3×0.5 Effective screw length: 3 6.5 Note: This is the Lens Unit for the E32-C31 and E32-C41. Lens Unit for Reflective Fiber Units E39-F3C Straight knurling 6 dia. 5.5 dia. Lens surface (lens diameter: 4.8 mm) Material: Aluminum for body and optical glass for lens. 60 24.1 25.2 Note: This is the Lens Unit for the E32-C31 and E32-C41. 5 dia. 4.3 dia. M3×0.5 Depth: 4.4 5.8 Lens surface (lens diameter: 3.7 mm) Material: Aluminum for body and optical glass for lens. 10.9 M3×0.5 Effective screw length: 3 Note: This is the Lens Unit for the E32-C31 and E32-C41. Protective Spiral Tubes E39-F32A/F32A5 E39-F32B/F32B5 Head connector (brass/nickel plating) M3×0.5 Depth: 4 End cap (brass/nickel plating) 3 dia. 6 dia. 12 tube 4.6 dia. (SUS304) 12 L Note 1. The length L is 1,000 for the E39-F32A/-F32B and 500 for the E39-F32A5/-F32B5. 2. The E39-F32B(5) consists of two E39-F32A(5)s. E39-F32C/F32C5 End cap (brass/nickel plating) 4 dia. Head connector (brass/nickel plating) M6×0.7 Depth: 4 7 dia. 12 tube 5.6 dia. (SUS304) 12 L Note: The length L is 1,000 for the E39-F32C and 500 for the E39-F32C5. E39-F32D/F32D5 End cap (brass/nickel plating) Head connector (brass/nickel plating) 5 dia. M6×0.75 Depth: 4 8.5 dia. 12 tube 7 dia. (SUS304) 12 L Note: The length L is 1,000 for the E39-F32D and 500 for the E39-F32D5. 61 Accessories Other Accessories Fiber Cutter E39-F4 8 Thin-fiber Attachments E39-F9 45 1.1 dia. 2.2 dia. 24.5 10 Material: ABS Fiber Connector E39-F10 25 Note: Two per set. *Provided with thin-fiber models. Thin-fiber insertion hole Standard-fiber insertion hole 3.6 dia. 11.7 Optical fiber: 2.2. dia. Retention clip (Brass) Retention clip (Brass) Splice (Polyester) 3.8 dia. Optical fiber: 2.2. dia. 3 dia. 26 12.8 Fiber Connector E39-F13 E39-F14 E39-F15 (48.6) 32.6 9.2 7.6 29.6 2 3.2 Note: Dimension A varies with the model number as shown in the following table. 8 33.8 22.4 20.4 27.4 Four, 6 dia 4-0.8 Four, A (See note.) Sleeve Bender E39-F11 42.5 10 10 10.8 Model E39-F13 E39-F14 E39-F15 Dimension A 2.4 1.2 2.4/1.2 Four, R0.8 Mounting Bracket E39-L83 0.4 Six, R1.2 1.8 3.2 3.5 27 R10 R12.5 R1.6 2.8 62 4.3 Two, R1.6 R5 R7.5 3.2 10 11 17.6 Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Fiber Units ● Mounting Tightening Force The tightening force used to mount the Fiber Unit must not be more than the value given in Ratings/Characteristics. Screw-mounting Model Cylindrical Model Fiber Cutting Procedure Cut a thin fiber as follows: The fiber is shipped loosely tightened as shown in the figure (1) at the right. Thin fiber attachment (E39-F9) Temporarily fitted Adjust the fiber to the desired length (2) and then tighten it securely. Insert the fiber to be cut into the E39-F4. Cutter (E39-F4) (3) Two holes for thin fiber Spring mounting clip Retaining screw (flat head or sunken head) (M3 max.) Toothed washers Three holes for standard fiber (2.2-mm dia.) Finished state (proper cutting state) Use a proper-sized wrench. Nuts (attachment) Approx. 0.5 mm (4) Insertion direction Note: Insert the fiber into the amplifier the direction indicated by the arrow. Chemical-resistive Models The following method is recommended to prevent the fluororesin case from cracking when the Sensor is being secured. Be especially careful not to crack the case when using screws to secure the Sensor. Fiber Sensing Head Connection • Do not excessively pull or press the Fiber Unit. Use a pulling force no higher than what is given in Ratings/Characteristics. • Do not bend the Fiber Unit beyond the permissible bending radius given under Ordering Information. • Do not bend the edge of the Fiber Units (excluding the E32-T@R and E32-D@R). Correct Incorrect 10 mm min. Amplifier Unit Fiber Unit 10 mm min. • Do not apply excess force on the Fiber Units. Correct Incorrect Fiber Unit Nylon wireholder The Fiber Head could be broken by excessive vibration. To prevent this, the following is effective: A one-turn loop can absorb vibrations. Tape 63 E39-F11 Sleeve Bender • The bending radius of the stainless steel tube should be as large as possible. The smaller the bending radius becomes, the shorter the sensing distance will be. • Insert the tip of the stain1.2 mm dia. max. less steel tube to the 1.3 mm dia. min. R10 mm Sleeve Bender and bend the stainless steel tube R12.5 mm R5 mm slowly along the curve of R7.5 mm the Sleeve Bender. Fiber tip position mark 90° max. Stainless steel tube 10 mm 10 mm E32-A07E1(E2) There is a difference in sensing object angle between E32-A07E1 and E32-A07E2. Select a model in accordance with the bending direction of a sensing object. Use the fiber with a model display tube as light emitting side. View from the cable drawing side Sensing object Emission Reception E32-A07E2 Reception Emission E32-A07E1 ● Adjustment Do not bend here. Heat-resistant Fiber Units (E32-D51 and E32-T51) • The fibers of these Units cannot be extended using the E39F10 Fiber Connector. • The maximum allowable temperature for continuous operation with these Units is 130°C. It is 150°C for short-term use. E32-T14 and E32-G14 These Units may enter the light-ON state if there are reflecting objects at the ends of the lenses. In this case, attach the black stickers provided to the ends of the lenses. Stickers Wafer Sensors (E32-L25(A)) • To ensure correct performance, insert the fiber with a white line into the emitter-side port of the Amplifier Unit. E32-T16 and E32-T16P Example E32-T16's sensing head Slit provided To use the slit provided, peel off the backing sheet, align it with the edges of the sensing surface, and attach it to the sensing head. Use the slit in applications where saturation occurs (i.e., changes in light intensity cannot be obtained) due to short sensing distances. E32-M21 Separate the 4 fibers by distances sufficient to prevent interference. Vacuum-resistant Fiber Units (E32-V) Although Flanges, Fiber Units on the vacuum side, and Lens Units have been cleaned, as an extra precaution, clean these products with alcohol before use in high-vacuum environments to ensure that they are properly degreased. Liquid-level Detection Sensors (E32-D82F) • Secure the Fiber Unit using the unbendable section. Otherwise, the liquid-level detection position may be displaced. • For applications in hazardous environments, install the Fiber Unit in the hazardous environment but install the Amplifier Unit in a safe environment. 64 Liquid-level Detection Sensors: Tube-mounting Models • Ensure that the tube is not deformed when using a band to secure the Fiber Unit. • Drops of water, bubbles, or haze inside the tube may cause malfunctions. E32-G14 When a Digital Fiber Amplifier is used, the sensing distance is short, making the incident light intensity large. This makes it impossible to teach without a workpiece. Liquid-level (E32-D82F) Detection Position The liquid-level detection position is at a distance of 5.2±2 mm from the end of the fluororesin section. Liquid-level detection position (Refer to the diagram on the 5.2±2 mm (from the end of the right.) fluororesin section) The liquid-level detection position varies with the surface tension of the liquid and the degree of wetness at the Fiber Unit's detection position. ● Other Considerations Liquid Level (E32-D82F) • Operation may become unstable in the following cases: A Bubbles stick to the cone of the sensing head. B Solute is deposited on the cone of the sensing head. C The liquid has a high viscosity. • There are some liquids, such as milky white liquids, for which detection is not possible. • Do not let the end of the fluororesin section bump into another object. Damage to, or deformation of, the sensing head may result in unstable operation. Heat-resistant Fiber Units (E32-D81R(-S), E32-D61(-S), and E32-D73(-S)) The pitch of the emission-side and reception-side fiber-insertion ports varies with the Amplifier Unit. Be sure to use an appropriate Fiber Unit. Amplifier Unit E3X-DA@-S E3X-MDA@ E3X-DA@-N E3X-NA@ Fiber Unit E32-D@-S E32-D@ Chemical-resistant Fiber and Liquid Level (E32-D82F) Fluororesin has high chemical resistance. However, applications in the atmosphere of vaporized chemicals (gases) or steam may cause malfunction or damage inside sensors. Run a full check before using in such environments. ■ Accessories Use of E39-R3 Reflector 1. Use detergent, etc., to remove any dust or oil from the surfaces where tape is applied. Adhesive tape will not be attached properly if oil or dust remains on the surface. 2. The E39-R3 cannot be used in places where it is exposed to oil or chemicals. E39-F32@ Protective Spiral Tubes 1. Insert a fiber to the Protective Spiral Tube from the head connector side (screwed) of the tube. 2. Push the fiber into the Protective Spiral Tube. The tube should be straight so that the fiber is not twisted when inserted. Then turn the end cap of the spiral tube. 3. Secure the Protective Spiral Tube on a suitable place with the attached nut. Fiber Unit Splice Fiber Unit Protective Spiral Tube Fiber Unit Retention unit Retention unit Fiber Unit Protective Spiral Tube Mounting panel Protective Spiral Tube 4. Use the attached saddle to secure the end cap of the Protective Spiral Tube. To secure the Protective Spiral Tube at a position other than the end cap, apply tape to the tube so that the portion becomes thicker in diameter. E39-F10 Fiber Connector Mount the Fiber Connector as shown in the following illustrations. 1. Insert the Fiber Unit into the retention clip. 2. Insert the retention clip into the splice. Fiber Unit Fiber Unit • The Fiber Units should be as close as possible when they are connected. Sensing distance will be reduced by approximately 25% when fibers are connected. • Only 2.2-mm dia. fibers can be connected. Hexagon clamping nut Fiber Unit Toothed washer Saddle Tube End cap 65 66 READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.