VER : A_3 update : 2016.07.20 AC -DC Medical Power Module MSC60 SERIES 60 Watts KEY FEATURES Switching Power Modules for PCB Mounting Fully Encapsulated Plastic Case Universal Input Range 90-264VAC Regulated Output and Low Ripple and Noise <0.3W No Load Input Power Isolation Class II CE, CB, UL, cUL Approvals 3-Year Product Warranty ELECTRICAL SPECIFICATIONS All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. Model No. ( Single Output ) Max output wattage ( W ) Voltage Input Output MSC60-5S (Note 1) MSC60-9S 47-440 Hz Current (Full load) 1.5 A max. (115 VAC) / 1 A max. (230 VAC) Inrush current (<2ms,Cold Start) 55 A max. (115 VAC) / 95 A max. (230 VAC) Leakage Current < 0.1mA / 264 VAC (Touch Current) MSC60-24S External fuse (recommend) 3.15A, slow blow type Voltage (V.DC.) 9V 12V 15V 24V Voltage set accuracy 5.1V ±2% Current (mA) max 10,000 6666 5000 4000 2500 Maximum Capacitive Load (at 230 VAC) 10000uF 0.5% 5000uF 5000uF 4000uF 2000uF 86% 87% Line regulation (typ.) Ripple & Noise (max) (Note 2) Efficiency (at 230 VAC) Hold-up time 1.5% 1% 100mV (Vp-p) 1% of Vout 86% 10 ms min. 87% 88% Over current protection Automatic recovery Protection Over voltage protection Zener diode clamp Short circuit protection Automatic recovery Isolation Input-Output (V.AC) 4000V Operating temperature -40°C…+80°C (with derating) Physical MSC60-15S 51W 60W 90-264 VAC or 120-370 VDC Frequency (Hz) Load regulation (1-100%) (typ.) Environment MSC60-12S Storage temperature -40°C…+90°C Max Case Operating Temperature Under 115 VAC 73°C , others 80°C Temperature coefficient ±0.05%/°C Altitude During Operation 5000m Humidity up to 95% RH MTBF 200,000 h~400,000 h @ 25°C Atmospheric Pressure 70 kPa to 106 kPa Dimension (L x W x H) 3.5 x 2.5 x 1.06 Inches Case Material Plastic resin (flammability to UL 94V-0) Weight 280 g Cooling method Free air convection http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 ( 89.0 x 63.5 x 27.0 mm ) Tolerance 0.5 mm -1- VER : A_3 update : 2016.07.20 AC -DC Medical Power Module MSC60 SERIES 60 Watts ELECTRICAL SPECIFICATIONS All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. Model No. Safety ( Single Output ) Approval Conducted and radiated EMI EMC MSC60-5S MSC60-9S MSC60-12S MSC60-15S MSC60-24S cUL / UL Standard: UL 60950-1, CAN/CSA C22.2 No. 60950-1-07 ANSI/AAMI ES60601-1 (2005 + C1:09 + A2:10), CAN/CSA-C22.2 No. 60601-1 (2008), 2 x MOPP CB Standard: IEC 60950-1:2005 (2nd Edition) + Am 1:2009 + Am 2:2013 IEC 60601-1:2005 (3rd Edition) + CORR. 1 (2006) + CORR. 2 (2007) + AM1 (2012) or IEC 60601-1 (2012 reprint), 2 x MOPP EN55011 class B ESD EN61000-4-2 air ± 8kV , Contact ± 4kV Radiated Immunity EN61000-4-3 10V/m Fast Transient EN61000-4-4 ± 2kV Surge EN61000-4-5 ±1kV Conducted Immunity EN61000-4-6 10Vrms PFMF EN61000-4-8 30A/m Dips EN61000-4-11 30% 10ms Interruption EN61000-4-11 >95% 5000ms NOTE 1. This product is not designed for use in critical life support systems, equipment used in hazardous environment, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor. 3. Safety approvals cover frequency 47-63 Hz. 4. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 5. It's recommended to add Varistor 14S471K at L / N input side in parallel. 6. Please refer to our PDF file "AC-DC Application" on our website: www.archcorp.com.tw MECHANICAL DIMENSION ( Top View ) http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 PIN# Single 1 AC IN (L) 2 AC IN (N) 3 +DC OUT 4 NO PIN 5 -DC OUT 6 NO PIN 7 NO PIN -2- VER : A_3 update : 2016.07.20 AC -DC Medical Power Module MSC60 SERIES 60 Watts DERATING BLOCK DIAGRAM http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -3-