MVAD040 Series www.murata-ps.com 40W 2" x 4" AC-DC Power Supply Converter DESCRIPTION The MVAD040 series switching power supplies utilize advanced component and circuit technologies to deliver high efficiency. Designed for Medical, Telecom, and Industrial applications to satisfy 1U height design considerations, the MVAD040 Series measures only 2.0” x 4.0” x 1.3”. All models offer universal AC input and compliance to worldwide safety and EMC standards. ORDERING GUIDE Model Number MVAD040-12 MVAD040-24 MVAD040-48 FEATURES ATURES ITE (2nd) and Medical 3rd ed. MOOP safety approved 40W compact high density Natural Convection Cooling 40W INPUT CHARACTERISTICS Parameter 2" x 4" standard footprint Input Voltage Operating Range High efficiency up to 89% Input Frequency Turn-on Input Voltage Turn-off Input Voltage Input Current Universal AC input Low profile - 1U package Convection-cooled operation up to 40W Complies with 5000m altitude RoHS compliant UL Class I and II approved Less than 0.3W no load input power Complies with ErP/Energy Star requirement average efficiency (24V and 48V) >85.3% Main Output (V1) 12V 24V 48V Conditions Single phase DC Input rising at full load Input falling at full load 90Vac input, full load At 264Vac, at 25°C cold start Inrush Current Min. 90 120 47 50 50 Typ. 120/230 50/60 60 Max. 264 300 63 70 70 0.9 Units Vac Vdc Hz Vac A Apk OUTPUT CHARACTERISTICS Model Number MVAD040-12 MVAD040-24 MVAD040-48 Main Output Line, Load, Cross Typical Efficiency Load Current Peak Load3 Load Capacitance Voltage (V1) Regulation @230Vac full load 12V 24V 48V 0 to 3.34A 0 to 1.67A 0 to 0.84A 5.0A 2.5A 1.25A 0 to 680μF 0 to 330μF 0 to 220μF ± 2% ± 2% ± 2% 87% 88% 89% Main Output Characteristics (all models) www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html Parameter Conditions Min. Max. Units Transient Response 50% load step, 1A/μsec slew rate ±5 % Settling Time to 1% of Nominal 200 μsec Turn On Delay After application of input power 1 sec Output Voltage Rise Monotonic, 0 to 100% load 50 msec Setpoint Accuracy 120Vac, 40W, 25°C ± 0.5 % Output Holdup 115Vac, 100% load 15 msec Temperature Coefficient 0.02 %/°C 1 % Ripple Voltage & Noise1 1. Ripple and noise are measured with 0.1 μF of ceramic capacitance and 47 μF of electrolytic capacitance on each of the power supply outputs. A short coaxial cable with 50ohm scope termination is used. 2. Unless otherwise specified all readings are taken at 120Vac input and 25 °C ambient temperature. 3. Peak current lasting <15 seconds with a maximum 10% duty cycle and with an average output power of 40W. Available now at www.murata-ps.com/en/3d/acdc.html CB For full details go to www.murata-ps.com/rohs Test Certificate and Test Report www.murata-ps.com/support MVAD040.A01 Page 1 of 5 MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min. Full load 50% load Start up Non-condensing Without derating Telcordia SR-332 M1C3 25°C -40 -20 -20 -20 10 -200 1M Storage Temperature Range Operating Temperature Range Operating Humidity Operating Altitude MTBF Shock Operating, IEC60068-2-27, half-sine 5G, 6ms, 3 times per face, 6 faces Complies Non-operating, IEC60068-2-27, half-sine, 30G, 18ms, 3 times per face, 6 faces Complies Typ. Max. 85 50 70 95 5000 Units °C % m Hours Operating, IEC60068-2-6, 1.0G, 10-150Hz, Complies 10minutes per axis, on all 3 axes Vibration Non-operating, IEC60068-2-6, 2.0G, 10-150Hz, 10minutes per axis, on all 3 axes Complies Safety IEC60950-1:2006/A11:2009 UL60950-1 2nd Ed. 2007-03-27, CSA22.2 N0.60950-1 2nd Ed. 2007.03, EN60950-1:2006+A11:2009 IEC60601-1 Ed. 3 MOOP ANSI/AAMI ES60601-1 (2005+C1:09+A2:10), CSA 22.2 No. 60601-1 (2008) 3rd Edition MOOP EN60601-1:2006 3rd ed. MOOP (Evaluated) CE Marking per LVD Warranty Outside Dimensions Weight 2 years 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm) 0.27lbs (123g) typical PROTECTION CHARACTERISTICS Parameter Conditions Min. Overvoltage Protection Overcurrent Protection Latching (60% load) Hiccup mode 110 170 Typ. Max. Units 160 240 %V1 %Amax Max. Units ISOLATION CHARACTERISTICS Parameter Isolation Leakage Current Touch Current Conditions Primary to Earth Ground Primary to Secondary Secondary to Earth Ground 264Vac, 60Hz, 25°C 264Vac, 60Hz, 25°C Min. Typ. 1500 (1MOOP) 3000 (2MOOP) 500 Vac 250 100 Vdc μA μA EMISSIONS AND IMMUNITY Characteristic Standard Compliance Input Current Harmonics Voltage Fluctuation and Flicker IEC/EN 61000-3-2 IEC/EN 61000-3-3 EN 55022 FCC Part 15 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-4-8 IEC/EN 61000-4-11 Class A Complies Class B Class B Level 4, Criterion A Level 2, Criterion A Level 3, Criterion A Level 4, Criterion A Level 2, Criterion A Level 2, Criterion A Level 3, Criterion B Conducted Emissions ESD Immunity Radiated Field Immunity Electrical Fast Transient Immunity Surge Immunity RF Conducted Immunity Magnetic Field Immunity Voltage dips, interruptions www.murata-ps.com/support MVAD040.A01 Page 2 of 5 MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter EMI CONSIDERATIONS For optimum EMI performance, the power supply should be mounted to a metal plate grounded to all 4 mounting holes of the power supply. To comply with safety standards, this plate must be properly grounded to protective earth (see mechanical dimension notes). Pre-compliance testing has shown the standalone power supply to comply with EN55022 class A radiated emissions. Radiated emission results vary with system enclosure and cable routing paths. PERFORMANCE DATA MVAD040-12 Eĸciency (%) MVAD040-24 Eĸciency (%) 95 95 93 93 91 91 89 89 87 87 85 85 83 83 81 81 79 79 77 77 75 75 0 0.5 1 1.5 2 2.5 3 3.5 0 0.3 0.6 Output current (A) AC90V AC115V 0.9 1.2 1.5 1.8 Output current (A) AC230V AC264V AC90V AC115V AC230V AC264V Inrush waveform MVAD040-48 Eĸciency (%) 95 93 91 89 87 85 83 81 79 77 75 0.0 0.2 0.4 0.6 0.8 1.0 Output current (A) AC90V AC115V AC230V AC264V MVAD040-12/24/48 Thermal DeraƟng 45 Output power (W) 40 35 30 25 20 15 10 5 0 -20 -10 0 10 20 30 40 50 Ambient temperature (°C) 60 70 80 www.murata-ps.com/support MVAD040.A01 Page 3 of 5 MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter MECHANICAL DIMENSIONS – MVAD040-12 ONLY Dimensions: 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm) INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS PIN Description Input Connector CN1 : Molex 26-62-4030 1 AC Line (V-) 3 AC Neutral (V+) Spade Connector: #250 GND Earth Ground Output Connector CN2 : Molex 26-60-4040 1, 2 V1 3, 4 DC Return Mating Housing Crimp terminal/pins Molex 09-50-8031 with locking ramp Molex 6838 Series Molex 09-50-8061 with locking ramp Molex 6838 Series www.murata-ps.com/support MVAD040.A01 Page 4 of 5 MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter MECHANICAL DIMENSIONS – MVAD040-xx 24V and 48V MODELS Dimensions: 2.0” x 4.0” x 1.3” (50.8mm x 101.6mm x 33.02mm) INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS PIN Description Input Connector CN1 : Molex 26-62-4030 1 AC Line (V-) 3 AC Neutral (V+) Spade Connector: #250 GND Earth Ground Output Connector CN2 : Molex 26-60-4040 1, 2 V1 3, 4 DC Return Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED Mating Housing Crimp terminal/pins Molex 09-50-8031 with locking ramp Molex 6838 Series Molex 09-50-8061 with locking ramp Molex 6838 Series This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2013 Murata Power Solutions, Inc. www.murata-ps.com/support MVAD040.A01 Page 5 of 5