Dallas DS1815-10 3.3v econoreset with push-pull output Datasheet

DS1815
3.3V EconoReset with Push-Pull Output
www.dalsemi.com
FEATURES
PIN ASSIGNMENT
Automatically restarts a microprocessor after
power failure
Maintains reset for 150 ms after VCC returns
to an in-tolerance condition
Reduces need for discrete components
Precision temperature-compensated voltage
reference and voltage sensor
Accurate 5%, 10% or 20% power monitoring
Low-cost TO-92 or space saving surfacemount SOT-23 packages available
Push-pull output for low current operation
Operating temperature -40°C to +85°C
3
1
2
SOT-23 PACKAGE
1 2 3
1 2 3
TO-92 PACKAGE
See Mech.
Drawings Section
PIN DESCRIPTION
TO-92
1
2
3
RST
VCC
GND
Active Low Reset Output
Power Supply
Ground
SOT-23
1
2
3
RST
VCC
GND
Active Low Reset Output
Power Supply
Ground
DESCRIPTION
The DS1815 EconoReset uses a precision temperature reference and comparator circuit to monitor the
status of the power supply (VCC). When an out-of-tolerance condition is detected, an internal power-fail
signal is generated which forces reset to the active state. When VCC returns to an in-tolerance condition,
the reset signal is kept in the active state for approximately 150 ms to allow the power supply and
processor to stabilize.
1 of 5
111999
DS1815
OPERATION - POWER MONITOR
The DS1815 provides the functions of detecting out-of-tolerance power supply conditions and warning a
processor-based system of impending power failure. When VCC is detected as out of tolerance, the RST
signal is asserted. On power-up, RST is kept active for approximately 150 ms after the power supply has
reached the selected tolerance. This allows the power supply and microprocessor to stabilize before RST
is released.
BLOCK DIAGRAM (CMOS OUTPUT) Figure 1
APPLICATION EXAMPLE Figure 2
APPLICATION DIAGRAM:
RST VALID TO 0 VOLTS VCC ON THE DS1815 Figure 3
2 of 5
DS1815
TIMING DIAGRAM: POWER-UP Figure 4
TIMING DIAGRAM: POWER-DOWN Figure 5
3 of 5
DS1815
ABSOLUTE MAXIMUM RATINGS*
Voltage on VCC Pin Relative to Ground
Voltage on RST Relative to Ground
Operating Temperature
Storage Temperature
Soldering Temperature
*
-0.5V to +7.0V
-0.5V to +5VCC +0.5V
-40°C to +85°C
-55°C to +125°C
260°C for 10 seconds
This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods of time may affect reliability.
RECOMMENDED DC OPERATING CONDITIONS
PARAMETER
Supply Voltage
SYMBOL
VCC
DC ELECTRICAL CHARACTERISTICS
PARAMETER
MIN
0.0
(-40°C to +85°C)
TYP
MAX
5.5
UNITS
V
NOTES
1
(-40°C to +85°C; VCC=1.2V to 5.5V)
SYMBOL
MIN
TYP
Output Voltage @ -500 µA
VOH
VCC
-0.5V
Output Current @ 2.4 V
IOH
Output Current @ 0.4 V
IOL
Operating Current VCC < 5.5
ICC
VCC Trip Point (DS1815-5)
VCCTP
VCC Trip Point (DS1815-10)
MAX
UNITS
NOTES
VCC
-0.1V
V
1
350
µA
2
mA
2
+10
28
35
µA
3
2.98
3.06
3.15
V
1
VCCTP
2.80
2.88
2.97
V
1
VCC Trip Point (DS1815-15)
VCCTP
2.47
2.55
2.64
V
1
Output Capacitance
COUT
10
pF
AC ELECTRICAL CHARACTERISTICS
PARAMETER
(-40°C to +85°C; VCC=1.2V to 5.5V)
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
RESET Active Time
tRST
100
150
250
ms
4
VCC Detect to RST
tRPD
2
5
µs
VCC Slew Rate
(VCCTP (MAX) to VCCTP (MIN))
tF
300
µs
VCC Slew Rate
(VCCTP (MIN) to VCCTP (MAX))
tR
0
ns
tRPU
100
VCC Detect to RST
4 of 5
150
250
ms
6
4, 5
DS1815
NOTES:
1. All voltages are referenced to ground.
2. Measured with VCC ≥ 2.7V.
3. Measured with RST output open.
4. Measured with 2.7V ≤ VCC ≤ 3.3V.
5. tR = 5 µs.
6. The tF value is for reference in defining values for TRPD and should not be considered a requirement
for proper operation or use of the device.
PART MARKING CODES
“A”, “B”, &“C” represent the device type.
810 . . . . DS1810
811 . . . . DS1811
812 . . . . DS1812
813 . . . . DS1813
815 . . . . DS1815
816 . . . . DS1816
817 . . . . DS1817
818 . . . . DS1818
“D” represents the device tolerance.
A . . . . . . 5%
B . . . . . . 10%
C . . . . . . 15%
D . . . . . . 20%
5 of 5