MPM-03 Series Single Output, 3W Ultra-Miniature DIP AC/DC Power Supplies Key Features: Electrical Specifications • 3W Output Power • Universal 85-264 VAC Input • EN 60950 Approved (UL) • Meets IEC Safety Class II • Single Regulated Output • Meets EN 55022 Class A • >300 kHour MTBF • Ultra-Miniature “DIP” Case Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Input Voltage Range Input Frequency Input Current Inrush Current Min. Typ. 85 110 47 See Model Selection Guide 115 VAC 10.0 230 VAC 20.0 Max. 264 370 63 Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Note 1 ±2.0 ±0.5 VIN = Min to Max See Note 3 ±1.0 30 230 VAC 50 ±0.02 Continuous (Autorecovery) Max. Units VAC VDC Hz A Pk Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Short Circuit Protection Over Temperature Protection 60 Units % % % mV P-P mSec %/°C 150 °C Max. Units VAC M General Parameter Isolation Voltage Isolation Resistance EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT Surge CS PFMF Voltage Dips Switching Frequency Conditions Input to Output 500 VDC Min. 3,000 100 Typ. Standard See Note 4 EN 55022 See Note 4 EN 55022 EN 61000-4-2 EN 61000-4-3 See Note 5 EN 61000-4-4 See Note 5 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 EN 61000-4-11 Min. Typ. Min. -25 Typ. +25 Max. Units Class A Class A Criteria B; ±8 kV Air/±6 kV Contact Criteria A; 10V/m Criteria B; ±2 kV Criteria B; ±1 kV /±2 kV Criteria A; 10 Vrms Criteria A; 10A/m Criteria B; 0% - 70% 100 kHz Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Max. +70 +95 -40 +105 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Case Units °C °C °C % Physical T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Case Size Case Material Weight 1.46 x 0.90 x 0.59 Inches (37.0 x 23.0 x 15.0 mm) Non-Conductive Black Plastic (UL94-V0) 0.70 Oz (20g) Reliability Specifications Parameter MTBF Safety Standards Safety Class Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 300 EN 60950 IEC 60536 Class II www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Input Model Number MPM-03S-03 MPM-03S-05 MPM-03S-09 MPM-03S-12 MPM-03S-15 MPM-03S-24 Output Current (A) 115 VAC 0.065 0.065 0.065 0.065 0.065 0.065 230 VAC 0.030 0.030 0.030 0.030 0.030 0.030 Typical Connection Standby Power Voltage Current (VDC) (mA Max.) (W, Max) 3.3 5.0 9.0 12.0 15.0 24.0 700 600 330 250 200 125 0.25 0.30 0.35 0.35 0.35 0.35 Notes: 1. For the 3.3V output model, Output Accuracy is ±3.0% 2. Operation at no load will not damage the units, however, they may not meet all specifications. 3. Load regulation is measured for an output change of 10% to 100% at nominal input line. 4. All units are rated for EN 55022 (CE/RE) class A without external components. They will meet EN 55022 class B with the addition of the ACFM-01 (or a similar discrete filter circuit). Contact the factory for more information. 5. To meet the input surge requirements of EN 61000-4-4 (±2 kV) & EN 61000-4-5 (±1 kV /±2 kV), external components are needed. This can be done discretely, or with the addition of the ACFM-01. Contact the factory for more information. 6. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-03S series, a 0.5A/250 VAC slow blow should be used. Efficiency (%, Typ) 63 72 74 76 76 78 The diagram below illustrates a typical application connection of the MPM-03S series. Notes on this circuit (starting with the input circuit) are: 1. It is recommended that an external fuse and NTC be used. The recommended fuse is a 0.5A/250V slow blow and for the NTC, a 5D-9. 2. An external MOV is recommended on the input to protect the unit in the event of a surge. A 561KD14 or equivalent is recommended. 3. Recommended output filtering capacitors are: MPM-03S-03 MPM-03S-05 MPM-03S-09 MPM-03S-12 MPM-03S-15 MPM-03S-24 C1 1.0 µF 1.0 µF 1.0 µF 1.0 µF 1.0 µF 1.0 µF C2 150 µF 150 µF 120 µF 120 µF 120 µF 68 µF C3 4.7 µF/400V 4.7 µF/400V 4.7 µF/400V 4.7 µF/400V 4.7 µF/400V 4.7 µF/400V TVS SMBJ7.0A SMBJ7.0A SMBJ12A SMBJ20A SMBJ20A SMBJ30A The output filtering capacitor (C2) is a high frequency, low resistance electrolytic capacitor. Capacitor (C1) is ceramic. Voltage derating of capacitors should be 80% or above. 4. Input noise and surge suppression modules are available for a number of MPD AC/DC power supplies. An MPM-03S connection with the ACFM-01 is illustrated in the diagram at left. For pricing or full technical information on these modules (ACFM-01 and ACFM-02) please contact the factory. Typical Connection: With ACFM-01 Input Module (See note 4) Mechanical Dimensions Derating Curve Input Voltage Vs Load Pin Connections Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) MicroPower Direct Pin Function 1 AC-Line 3 AC-Neutral 13 No Connection 14 -VOUT Pin Function 16 22 26 +VOUT +VCAP -VCAP We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]