Wall DHW24S12-50 50 watt dc/dc power converter Datasheet

DHW50 SERIES
50 Watt DC/DC Power Converters
Rev D
Standard Models
FEATURES
• RoHS & UL 94V-0 Compliant
• No Minimum Load Requirements
• Smallest Encapsulated 50W Converter
• Trimmable Output Voltage
• 4:1 Wide Input Voltage Ranges
• Shielded Metal Case with Isolated Base-plate
• Single Outputs
• Over Load, Short Circuit, Over Voltage, & Over
• Remote ON/OFF Control
Size: 2.00 x 1.00 x 0.43 inches (50.8 x 25.4 x 11.0 mm)
Heatsink Models (Suffix “HS”)
Temperature Protection
• 1500VDC I/O Isolation
• -40°C to +80°C Operating Temperature Range
• High Efficiency up to 92%
• CSA/UL/IEC/EN 60950-1 Safety Approvals
• Under Voltage Lockout (UVLO)
• Heatsink (Optional)
DESCRIPTION
Size: 2.00 x 1.22 x 0.71 inches (50.8 x 31.0 x 18.0 mm)
The DHW50 series is the latest generation of high performance DC/DC converters
setting a new standard concerning power density. These converters offer 50 Watts of
continuous output power in a 2.0” x 1.0” x 0.43” encapsulated, shielded metal package.
All models have a 2:1 wide input voltage range and a precisely regulated single output.
Advanced circuit topology provides a very high efficiency up to 92% and an operating
temperature range of -40°C to +80°C. Further features include remote on/off, trimmable
output voltage, under voltage lockout as well as over load, over voltage, short circuit,
and over temperature protection. These converters are RoHS compliant and are ideal
for use in battery operated equipment, instrumentation, distributed power architectures
in communication and industrial electronics and many other space critical applications.
MODEL SELECTION TABLE
Model Number Input Voltage
DHW24S3.3-33
Output
Voltage
Output Current
Input Current
Reflected
Over Voltage Output
Maximum
Efficiency
Capacitive Load
Min
Max No Load Max Load Ripple Current Protection Power
3.3 VDC
0mA
10A
80mA
1528mA
3.9 VDC
33W
90%
26,000µF
5 VDC
0mA
10A
60mA
2290mA
6.2 VDC
50W
91%
17,000µF
12 VDC
0mA
4.17A
80mA
2267mA
15 VDC
50W
92%
3,000µF
DHW24S15-50
15 VDC
0mA
3.33A
80mA
2263mA
18 VDC
50W
92%
2,000µF
DHW24S24-50
24 VDC
0mA
2.08A
80mA
2286mA
30 VDC
50W
91%
750µF
DHW48S3.3-33
3.3 VDC
0mA
10A
40mA
764mA
3.9 VDC
33W
90%
26,000µF
5 VDC
48 VDC
DHW48S12-50
12 VDC
(18 - 75 VDC)
DHW48S15-50
15 VDC
0mA
10A
30mA
1145mA
6.2 VDC
50W
91%
17,000µF
0mA
4.17A
60mA
1134mA
15 VDC
50W
92%
3,000µF
0mA
3.33A
60mA
1134mA
18 VDC
50W
92%
2,000µF
DHW48S24-50
0mA
2.08A
50mA
1143mA
30 VDC
50W
91%
750µF
DHW24S5-50
DHW24S12-50
24 VDC
(9 - 36 VDC)
DHW48S5-50
05/16/2017
24 VDC
40mA
30mA
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 1 of 13
DHW50 SERIES
50 Watt DC/DC Power Converters
Rev D
SPECIFICATIONS: DHW50 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
9
18
-0.7
-0.7
24
48
36
75
50
100
9
18
Unit
INPUT SPECIFICATIONS
Input Voltage Range
Input Surge Voltage (100ms max.)
Start-up Threshold Voltage
Under Voltage Lockout (UVLO)
24VDC nominal input models
48VDC nominal input models
24VDC nominal input models
48VDC nominal input models
24VDC nominal input models
48VDC nominal input models
24VDC nominal input models
48VDC nominal input models
VDC
Power Up
Remote On/Off
VDC
Input Current
Reflected Ripple Current (Page 9)
See Table
Nominal Vin and constant resistive load
VDC
7.5
16
30
30
See Table
Start-up Time
VDC
Conducted EMI
for EN55032 Class A and FCC level A compliance see page 1
Short Circuit Current
Automatic Recovery
ms
Internal LC Filter
Hiccup mode 0.3Hz typ.
OUTPUT SPECIFICATIONS
Output Voltage
See Table
Output Voltage Setting Accuracy
At 50% load and nominal Vin
±1.0
%Vnom
Line Regulation
Low line to high line at full load
±0.5
%
Load Regulation
Minimum load to full load
±0.5
%
Minimum Load
Output Voltage Trim (Note 4) (Page 5) % of nominal output voltage
24VDC output models
Others
-10
-10
Output Power
Output Current
Ripple & Noise (20MHz BW) (Page 9)
Transient Recovery Time (Note 1)
No minimum load required
+20
+10
See Table
See Table
100
150
250
Measured with a 1µF MLCC and a 3.3V & 5V output models
10µF tantalum capacitor in parallel 12V, 15V, & 24V output models
25% load step change
Transient Recovery Deviation (Note 1) 25% load step change
±3
Temperature Coefficient
%
mVp-p
µs
±5
%
±0.02
%/°C
PROTECTION
Input Polarity Protection
none
Over Voltage Protection (page 9)
See Table
Over Current Protection
Hiccup
Thermal Protection
Shutdown temperature
Short Circuit Protection
Automatic recovery
Current limitation at 150% typ. of Io max
110
°C
Hiccup Mode 0.3Hz typ.
REMOTE ON/OFF (Page 9)
Converter On
Converter Off
On
Control Input Current
Off
Control Common
3.5V~12V or open circuit
0V~1.2V or short circuit
0.5
mA
-0.5
Referenced to negative input
Positive Logic
Stand-by Input Current
Vctrl = 5.0V
Vctrl = 0V
Nominal Vin
2.5
mA
GENERAL
Efficiency
(see efficiency curves on pages 7~8)
See Table
Switching Frequency
285
60 seconds
1 Second
1500
1800
Isolation Resistance
500VDC
1000
Isolation Capacitance
100kHz, 1V
Isolation Voltage
Maximum Capacitive Load
05/16/2017
KHz
VDC
MΩ
2200
pF
See Table
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 2 of 13
DHW50 SERIES
50 Watt DC/DC Power Converters
Rev D
SPECIFICATIONS: DHW50 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
Unit
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature (W/O
Heatsink)
(see derating curves on page 6)
Natural air convection
(20LFM)
Nominal Vin and full load
Operating Temperature (W/ Heatsink)
(see derating curves on page 6)
Natural air convection
(20LFM)
Nominal Vin and full load
Thermal Impedance (W/O Heatsink)
Thermal Impedance (W/ Heatsink)
Case Temperature
Storage Temperature
Humidity (non-condensing)
RFI
Cooling
Lead Temperature
MTBF (calculated)
DHW24S3.3-33, DHW48S3.3-33
DHW24S12-50, DHW24S15-50,
DHW48S12-50, DHW48S15-50
DHW24S5-50, DHW24S24-50,
DHW48S5-50, DHW48S24-50
DHW24S3.3-33, DHW48S3.3-33
DHW24S12-50, DHW24S15-50,
DHW48S12-50, DHW48S15-50
DHW24S12-40, DHW24S15-40
Natural convection (20LFM)
100LFM convection
200LFM convection
400LFM convection
Natural convection (20LFM)
100LFM convection
200LFM convection
400LFM convection
-40
+61
-40
+53
-40
+46
-40
+69
-40
+62
-40
12.1
9.2
7.8
5.2
9.8
5.4
4.5
3.0
+57
°C
°C
°C/W
°C/W
+105
°C
+125
°C
95
% RH
Six-sided shielded metal case
natural convection
260
°C
230,900
hours
-50
Natural convection is about 20LFM and is not still air (0LFM)
1.5mm from case for 10 seconds
MIL-HDBK-217F at 25°C, Ground Benign
PHYSICAL SPECIFICATIONS
Weight
1.2oz (34g)
2.00 x 1.00 x 0.43 inches
(50.8 x 25.4 x 11.0 mm)
Aluminum alloy, black anodized coating
FR4 PCB (flammability to UL 94V-0 rated)
Epoxy (UL94-V0)
Copper alloy with gold plate over nickel sub-plate
See page 4
Dimensions (L x W x H)
Case Material
Base Material
Potting Material
Pin Material
Heatsink (optional)
“HS” suffix
SAFETY & EMC
Safety Approvals
EMI
ESD
Radiated Immunity
Fast Transient (See Note 5)
Surge (See Note 5)
Conducted Immunity
Conduction, EN55032, FCC part 15
EN61000-4-2
Air: ±8KV, Contact±6KV
EN61000-4-3
10V/m
EN61000-4-4
±2KV
EN61000-4-5
±1KV
EN61000-4-6
10V/m
UL/cUL 60950-1 recognition (CSA certificate)
IEC/EN 60950-1 (CB-scheme)
Class A
A
A
A
A
A
NOTES
1. Transient recovery time is measured to within 1% error band for a step change in output load from 75% to 100%.
2. We recommend protecting the converter by a slow blow fuse in the input supply line.
3. To order the converter with a heatsink, please add the suffix “HS” to the model number. (Ex: DHW24S12-50HS)
4. Do not exceed maximum power specification when adjusting the output voltage.
5. The DHW50 series can meet EN61000-4-4 & EN61000-4-5 by adding a capacitor across the input pins. Capacitor: 220uF/100V
6. Other input and output voltages may be available; please call factory for ordering details.
\
05/16/2017
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 3 of 13
Rev D
DHW50 SERIES
50 Watt DC/DC Power Converters
MECHANICAL DRAWINGS
Standard Models
Heatsink Models (“HS” Suffix)
05/16/2017
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 4 of 13
DHW50 SERIES
50 Watt DC/DC Power Converters
Rev D
OUTPUT VOLTAGE ADJUSTMENT
Output voltage trim allows the user to increase or decrease the output voltage of a module. This is accomplished by connecting an
external resistor between the Trim pin and either the +Vout or –Vout pins. With an external resistor between the Trim and –Vout pins,
the output voltage increases. With an external resistor between the Trim and +Vout pins, the output voltage set-point decreases.
Trim Up
Trim Down
Trim
1%
2%
3%
4%
5%
6%
7%
8%
9%
10%
DHWXXS3.3-33
Vout,up
Rup
3.333V
70.50kΩ
3.366V
29.28kΩ
3.399V
16.87kΩ
3.432V
10.90kΩ
3.465V
7.38kΩ
3.498V
5.06kΩ
3.531V
3.42kΩ
3.564V
2.20kΩ
3.597V
1.25kΩ
3.630V
0.49kΩ
Trim
1%
2%
3%
4%
5%
6%
7%
8%
9%
10%
DHWXXS5-50
Vout,up
Rup
5.050V
36.57kΩ
5.100V
16.58kΩ
5.150V
9.92kΩ
5.200V
6.59kΩ
5.250V
4.59kΩ
5.300V
3.25kΩ
5.350V
2.30kΩ
5.400V
1.59kΩ
5.450V
1.03kΩ
5.500V
0.59kΩ
Trim
1%
2%
3%
4%
5%
6%
7%
8%
9%
10%
DHWXXS3.3-33
Vout,down
Rdown
3.267V
63.59kΩ
3.234V
30.28kΩ
3.201V
18.19kΩ
3.168V
11.95kΩ
3.135V
8.13kΩ
3.102V
5.56kΩ
3.069V
3.70kΩ
3.036V
2.31kΩ
3.003V
1.21kΩ
2.970V
0.34kΩ
Trim
1%
2%
3%
4%
5%
6%
7%
8%
9%
10%
DHWXXS5-50
Vout,down
Rdown
4.950V
45.53kΩ
4.900V
20.61kΩ
4.850V
12.31kΩ
4.800V
8.15kΩ
4.750V
5.66kΩ
4.700V
4.00kΩ
4.650V
2.81kΩ
4.600V
1.92kΩ
4.550V
1.23kΩ
4.500V
0.68kΩ
Trim
1%
2%
3%
4%
5%
6%
7%
8%
9%
10%
DHWXXS12-50
Vout,up
Rup
12.120V
368.92kΩ
12.240V
161.92kΩ
12.360V
94.97kΩ
12.480V
61.86kΩ
12.600V
42.12kΩ
12.720V
29.00kΩ
12.840V
19.66kΩ
12.960V
12.66kΩ
13.080V
7.23kΩ
13.200V
2.89kΩ
Trim
1%
2%
3%
4%
5%
6%
7%
8%
9%
10%
DHWXXS15-50
Vout,up
Rup
15.150V
392.98kΩ
15.300V
182.12kΩ
15.450V
108.73kΩ
15.600V
71.43kΩ
15.750V
48.85kΩ
15.900V
33.71kΩ
16.050V
22.86kΩ
16.200V
14.69kΩ
16.350V
8.33kΩ
16.500V
3.23kΩ
Trim
1%
2%
3%
4%
5%
6%
7%
8%
9%
10%
DHWXXS12-50
Vout,down
Rdown
11.880V
394.50kΩ
11.760V
179.74kΩ
11.640V
106.08kΩ
11.520V
68.86kΩ
11.400V
46.39kΩ
11.280V
31.36kΩ
11.160V
20.60kΩ
11.040V
12.51kΩ
10.920V
6.21kΩ
10.800V
1.17kΩ
Trim
1%
2%
3%
4%
5%
6%
7%
8%
9%
10%
DHWXXS15-50
Vout,down
Rdown
14.850V
572.67kΩ
14.700V
248.63kΩ
14.550V
145.60kΩ
14.400V
94.97kΩ
14.250V
64.87kΩ
14.100V
44.92kΩ
13.950V
30.72kΩ
13.800V
20.10kΩ
13.650V
11.86kΩ
13.500V
5.28kΩ
Trim
2%
4%
6%
8%
10%
12%
14%
16%
18%
20%
DHWXXS24-50
Vout,up
Rup
24.480V
247.2kΩ
24.960V 109.255kΩ
25.440V
63.38kΩ
25.920V
39.025kΩ
26.400V
27.52kΩ
26.880V
18.39kΩ
27.360V
11.77kΩ
27.840V
7.29kΩ
28.320V
3.308kΩ
28.800V
0.3658kΩ
Trim
1%
2%
3%
4%
5%
6%
7%
8%
9%
10%
DHWXXS24-50
Vout,down
Rdown
23.760V
318.05kΩ
23.520V
146.05kΩ
23.280V
85.8kΩ
23.040V
55.51kΩ
22.800V
37.415kΩ
22.560V
25.625kΩ
22.320V
16.515kΩ
22.080V
9.81kΩ
21.840V
4.9785kΩ
21.600V
0.9185kΩ
05/16/2017
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 5 of 13
Rev D
DHW50 SERIES
50 Watt DC/DC Power Converters
DERATING CURVES
Without Heatsink
With Heatsink
DHW24S3.3-33 & DHW48S3.3-33
DHW24S3.3-33 & DHW48S3.3-33
DHW24S12-50, DHW24S15-50, DHW48S12-50, DHW48S15-50
DHW24S12-50, DHW24S15-50, DHW48S12-50, DHW48S15-50
DHW24S5-50, DHW24S24-50, DHW48S5-50, DHW48S24-50
DHW24S5-50, DHW24S24-50, DHW48S5-50, DHW48S24-50
05/16/2017
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 6 of 13
DHW50 SERIES
50 Watt DC/DC Power Converters
Rev D
EFFICIENCY CURVES
24VDC NOMINAL INPUT MODELS
DHW24S3.3-33 Efficiency vs Load Current
DHW24S5-50 Efficiency vs Load Current
DHW24S12-50 Efficiency vs Load Current
DHW24S15-50 Efficiency vs Load Current
DHW24S24-50 Efficiency vs Load Current
05/16/2017
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 7 of 13
DHW50 SERIES
50 Watt DC/DC Power Converters
Rev D
EFFICIENCY CURVES
48VDC NOMINAL INPUT MODELS
DHW48S3.3-33 Efficiency vs Load Current
DHW48S5-50 Efficiency vs Load Current
DHW48S12-50 Efficiency vs Load Current
DHW48S15-50 Efficiency vs Load Current
DHW48S24-50 Efficiency vs Load Current
05/16/2017
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 8 of 13
DHW50 SERIES
50 Watt DC/DC Power Converters
Rev D
EUT
Operating Modes of EUT and Determination of Worst Case Operating Mode
Test modes presented in report below.
Mode
1
2
3
4
Mode
3
Conducted & Radiated Emission Test
Model No.
Input
DHW12S3.3-33
12VDC
DHW24S24-50
24VDC
DHW48S24-50
48VDC
DHW48S3.3-33
48VDC
Immunity Tests
Model No.
Input
DHW48S24-50
48VDC
Output
3.3VDC
24VDC
24VDC
3.3VDC
Output
24VDC
Test Program Used and Operation Description
Emission Test: Set the EUT under full resistor load.
Immunity Tests: Connected a resistor load to DC output port of EUT to make EUT have maximum power consumption and a
multimeter was used to monitor voltage of output.
Primary Clock Frequencies of Internal Source
The highest frequency generated or used within the EUT or on which the EUT operates or tunes is below 108MHz, provided by factory,
for detailed internal source, please refer to manufacturers specifications.
EMI FILTER
Conduction & Radiation Solution
Class
Model
Class A
DHW50 Series
L1
1mH//1mH
7448031501
C1
3.3µF/100V 1210
X7S MLCC
C2
4.7µF/100V 1210 X7S
MLCC
C3, C4
1000pF/2kV 1206 X7R
MLCC
EFT & Surge Solution:
To meet EN61000-4-4 & EN61000-4-5, an external capacitor across the input pins is required. Suggested capacitor: 330uF/100V.
05/16/2017
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 9 of 13
Rev D
DHW50 SERIES
50 Watt DC/DC Power Converters
RADIATION REPORT
Radiation Class A Report
Limit Line: EN55032 Class A
Polarity: Horizontal
Limit Line: EN55032 Class A
Polarity: Vertical
05/16/2017
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 10 of 13
Rev D
DHW50 SERIES
50 Watt DC/DC Power Converters
TEST SETUP
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with an inductor Lin (4.7µH) and Cin (220µF, ESR < 1.0Ω at 100 KHz) to simulate
source impedance. Capacitor Cin offsets possible battery impedance. Current ripple is measured at the input terminals of the
module. Measurement bandwidth is 0-500 KHz.
Peak-to-Peak Output Noise Measurement Test
Use a 1µF ceramic capacitor and a 10µF tantalum capacitor. Scope measurement should be made by using a BNC socket,
measurement bandwidth is 0-20MHz. Position the load between 50mm and 75mm from the DC/DC converter.
DESIGN & FEATURE CONSIDERATIONS
Remote On/Off
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin and off during a logic low.
To turn the module on and off, the user must supply a switch to control the voltage between the on/off terminal and the –Vin
terminal. The switch can be an open collector or equivalent. A logic low is 0V to 1.2V. A logic high is 3.5V to 12V. The
maximum sink current at on/off terminal (Pin 3) during a logic low is -100µA.
Over Current Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can
endure overload for an unlimited duration.
Over Voltage Protection
The output over voltage clamp consists of control circuitry which is independent of the primary regulation loop that monitors
the voltage on the output terminals. The control loop of the clamp has a higher voltage set point than the primary loop. This
provides a redundant voltage control that reduces the risk of output over voltage. The OVP level can be found in the model
selection table.
Output Ripple Reduction
A good quality low ESR capacitor placed as close as possible across the load will give the best ripple and noise performance.
To reduce output ripple, it is recommended to use 4.7µF capacitors at the output.
05/16/2017
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 11 of 13
DHW50 SERIES
50 Watt DC/DC Power Converters
Rev D
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect
the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at
the input to ensure startup.
A Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality
low Equivalent Series Resistance (ESR < 1.0Ω at 100KHz) capacitor of a 10µF for the 24V and 48V devices.
Maximum Capacitive Load
The DHW50 series has a limitation of maximum connected capacitance on the output. The power module may be operated
in current limiting mode during start-up, affecting the ramp-up and the start-up time. The maximum capacitance can be found
in the model selection table.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module, and board
spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case
temperature must be kept below 105°C. The derating curves are determined from measurements obtained in a test setup.
MODEL NUMBER SETUP
DHW
24
S
12
Series Name
Input Voltage
Output Quantity
24: 9-36 VDC
S: Single Output
48: 18-75 VDC
-
50
HS
Ouptut Voltage
Output Power
Heatsink
3.3: 3.3 VDC
33: 33 Watts
None: No Heatsink
5: 5 VDC
50: 50 Watts
HS: Heatsink
12: 12 VDC
15: 15 VDC
24: 24 VDC
05/16/2017
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 12 of 13
Rev D
DHW50 SERIES
50 Watt DC/DC Power Converters
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely
with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide
ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your
future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
05/16/2017
(603)778-2300
(888)597-9255
(603)778-9797
[email protected]
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]