For more information, please visit the product page | For information on related products, view Dc Power Jacks date 11/20/2014 page 1 of 8 SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY 60 W power universal input (90~264 Vac) compact size single regulated output from 12~24 V over voltage and short circuit protections UL/cUL, Intertek and PSE safety approvals level V efficiency custom designs available output voltage output current output power ripple and noise1 (Vdc) max (A) max (W) max (mVp-p) 5 60 200 V 3.42 60 240 V 2.7 60 240 V ETSA120500U 12 ETSA190342U 19 ETSA240270U 24 efficiency level 1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors. O PART NUMBER KEY N Notes: TI MODEL N U • • • • • • • • ED FEATURES D IS C ETSA120500U X - XX - SZ - CXX Base Number example of 12 Vdc, 5 A DC Plug Type: see output plug options on page 7 Factory Input Cable: “Blank” = No Cable C = North American input cable 2 = European input cable 3 = United Kingdom input cable 4 = Australian input cable 5 = China input cable 6 = South Korea input cable 7 = Brazil input cable 8 = South Africa input cable 9 = Japan input cable cui.com Designation Reserved for Custom Configurations For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY date 11/20/2014 │ page 2 of 8 INPUT parameter conditions/description min voltage typ 90 47 inrush current 12 V output all other outputs leakage current 12 V output all other outputs no load power consumption 12 V output all other outputs U OUTPUT parameter conditions/description min line regulation PROTECTIONS conditions/description over voltage protection output voltage clamped by internal protection zener short circuit protection output shut down, auto restart TI parameter parameter Vac 63 Hz typ 1.4 1.5 A A 0.35 0.25 mA mA 0.3 0.5 W W max units ±1 % ±5 % N load regulation SAFETY & COMPLIANCE units 264 ED frequency max conditions/description min typ max units 1,500 Vac input to output at 10 mA for 1 minute input to output at 500 Vdc safety approvals UL/cUL (UL 60950-1), EN 60950-1/IEC 60950-1, PSE EMI/EMC FCC part 15, subpart b, class B; CE; CISPR 22, class B; ICES-003; ANSI C63.4; EN 61204-3; EN 55022; EN 55024; EN 61000-(2, 3); IEC 61000-4-(2, 3, 4, 5, 6, 8, 11) RoHS 2011/65/EU O N isolation voltage insulation resistance 100 MΩ ENVIRONMENTAL parameter max units 0 40 °C storage temperature -10 70 °C operating humidity 20 80 % storage humidity 10 90 % min D IS C operating temperature conditions/description cui.com typ For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY date 11/20/2014 │ page 3 of 8 MECHANICAL conditions/description 114 x 47 x 32.4 (4.488 x 1.850 x 1.276 inches) min input plug IEC320 / C14 max units mm 230 weight1 Notes: typ ED parameter dimensions 1. weight does not include AC Cord MECHANICAL DRAWING D IS C O N TI N U units: mm tolerance: ±1mm cui.com g For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY date 11/20/2014 │ page 4 of 8 DC CORD ED cord length U S&T CABLE GAUGE CORD LENGTH 16 AWG 1,000 mm ±100 ETSA190342U 18 AWG 1,530 mm ±100 ETSA240270U 18 AWG 1,530 mm ±100 N MODEL NO. ETSA120500U NORTH AMERICAN INPUT CABLE Ĭijıı IJĹĴıĮĴı IS C O N units: mm TI AC CORD EUROPEAN INPUT CABLE ń ŏ ō ĵ D IJķ ijĶıŗ ſ ŚńĮIJij ŏİIJĵĹĸĸ ŚőĮijĴ units: mm Ĭijıı ĮĴı cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY date 11/20/2014 │ page 5 of 8 AC CORD (CONTINUED) UNITED KINGDOM INPUT CABLE units: mm ŏ ED ń ŏİIJĵĹĸĸ ŚńĮIJij ō ĵ U +200 1830 -30 AUSTRALIAN INPUT CABLE N TI ŏ ŚőĮĴĶ ō ņ N O IS C D units: mm BLACK INSULATION 1830 ±30 cui.com ĵ SOUTH KOREA INPUT CABLE ō +200 1830-30 ŏ units: mm ń CHINA INPUT CABLE ŚńĮIJij +200 1830-30 ŏİIJĵĹĸĸ ŏİIJĵĹĸķġIJıłġijĶıŗſ units: mm For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY date 11/20/2014 │ page 6 of 8 AC CORD (CONTINUED) BRAZIL INPUT CABLE ED units: mm U 1830±30 SOUTH AFRICA INPUT CABLE TI N units: mm 1830±30 D IS C units: mm O JAPAN INPUT CABLE N 1830±30 cui.com For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY date 11/20/2014 │ page 7 of 8 OUTPUT PLUG OPTIONS 14±0.5 ED ø3.5 +0/-0.1 ø3.5 +0/-0.1 3.5 mm Phono Plug 14±0.5 *Tip positive P1 P1R C Right Angle PXR Standard PXX B A O IS C B N B A C C A B C Unit 5.5 2.1 9.5 mm P6/P6R 5.5 2.5 9.5 mm P7/P7R 3.5 1.35 9.5 mm P8/P8R 3.8 1.35 9.5 mm P9/P9R 3.8 1.05 9.5 mm TI Locking DC Plug EIAJ Plugs P5/P5R N Standard PX B A B A C A U Standard DC Plug A B C Unit P10 5.5 2.1 9.5 mm P11 5.5 2.5 9.5 mm EIAJ A B C P12/P12R EIAJ-1 2.35 0.7 P13/P13R EIAJ-2 4.0 1.7 P14/P14R EIAJ-3 4.75 1.7 C Right Angle PXXR D Stripped and Tinned 25±5 9±2 D DC PLUG TYPE PXX X X Plug Type: PXX = See above plug options ST = Stripped and Tinned Plug Angle: “blank” = Straight R = Right Angle *Contact CUI for additional plug options cui.com Plug Polarity: P = Center Positive N = Center Negative D Unit 9.5 NA mm 9.5 5.0 mm 9.5 5.0 mm For more information, please visit the product page | For information on related products, view Dc Power Jacks CUI Inc │ SERIES: ETSA 60W U │ DESCRIPTION: AC-DC POWER SUPPLY date 11/20/2014 │ page 8 of 8 REVISION HISTORY description date 1.0 initial release 12/05/2011 1.01 updated P7/P7R B dimension, V-Infinity branding removed, safety and EMI/EMC data updated 08/15/2012 1.02 updated DC Cord information 11/14/2012 1.03 updated series number 1.04 added ac cord options ED rev. 11/20/2012 11/20/2014 D IS C O N TI N U The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.