XP Power JCK4024S3V3 40 watts jck sery Datasheet

DCDC
40 Watts
xppower.com
JCK Series
•
2:1 Input Range
•
Very High Power Density
•
Single and Dual Outputs
•
High Efficiency Up to 92%
•
Remote On/Off
•
1600 VDC Isolation
•
3 Year Warranty
Specification
Input
Input Voltage Range
Input Current
Input Reflected
Ripple Current
Undervoltage Lockout
Input Surge
General
• 12 V (9-18 VDC),
24 V (18-36 VDC),
48 V (36-75 VDC)
• See table
• 20 mA pk-pk through 12 µH inductor,
5 Hz to 20 MHz
• 12 V models: ON 8.6 V, OFF 7.9 V typical
24 V models: ON 17.8 V, OFF 16 V typical
48 V models: ON 33.5 V, OFF 30.5 V typical
• 12 V models 25 VDC for 1000 ms
24 V models 50 VDC for 1000 ms
48 V models 100 VDC for 1000 ms
Output
Output Voltage
Output Voltage Trim
Minimum Load
Line Regulation
Load Regulation
Cross Regulation
Setpoint Accuracy
Start Up Time
Ripple & Noise
Transient Response
• See table
• ±10% on single outputs models only,
contact sales for details
• No minimum load required
• ±0.5% max
• Single output models: ±0.5% max
Dual output models: ±1% max
balanced outputs
• ±5% (see note 2)
• ±1%
• 30 ms typical
• 100 mV for 3V3 +5 V models,
150 mV for other models (see note 3)
• 3% max deviation, recovery to within
1% in <250 µs for a 25% load change
• 0.02%/˚C
Temperature
Coefficient
Overvoltage Protection • 3.3 V models: 3.9 V typical
5 V models: 6.2 V typical
12 V models: 15 V typical
15 V models: 18 V typical
±12 V models: ±15 V typical
±15 V models: ±18 V typical
Overload Protection
• 115-130% of output current
Short Circuit Protection • Trip & restart (Hiccup mode),
auto recovery
Remote On/Off
• On = Logic High (>3.0) or Open
Off = Logic Low (<1.2 V) or short pin 2
to 3
Efficiency
Isolation
Isolation Capacitance
Switching Frequency
Power Density
MTBF
• See table
• 1600 VDC Input to Output
1600 VDC Input to Case
1600 VDC Output to Case
• 1000 pF typical
• 270 kHz typical
• 50 W/in3
• 330 kHrs min to MIL-HDBK-217F
at 25 ˚C, GB
Environmental
Operating Temperature • -40 ˚C to +70` ˚C, derate from 100% load
at 55 °C to 60% load at 70 °C
Case Temperature
• +105 ˚C max
Cooling
• Convection-cooled
Operating Humidity
• 5-95% RH, non-condensing
Storage Temperature • -40 ˚C to +125 ˚C
EMC
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magentic Field
• EN55022 class B conducted & radiated
with external components, see application
note
• EN61000-4-2, 4 kV contact discharge,
Perf Criteria B
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 1, Perf Criteria A*
• EN61000-4-5, level 1, Perf Criteria A
• EN61000-4-6, 3 Vrms, Perf Criteria A
• EN61000-4-8, 1 A/m, Perf Criteria A
*External input capacitor required, 220 µF/100 V.
Input Voltage
Output Voltage
3.3
5.0
12.0
15.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±12.0
±15.0
9-18 VDC
18-36 VDC
36-75 VDC
Input Current (1)
No Load
Full Load
100 mA
2444 mA
150 mA
3663 mA
40 mA
3663 mA
50 mA
3663 mA
30 mA
3663 mA
50 mA
3623 mA
60 mA
1208 mA
80 mA
1811 mA
30 mA
1831 mA
40 mA
1811 mA
50 mA
1831 mA
40 mA
1811 mA
40 mA
604 mA
60 mA
905 mA
20 mA
915 mA
20 mA
905 mA
30 mA
906 mA
40 mA
906 mA
Output Current
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
8.00
8.00
3.33
2.67
±1.67
±1.33
8.00
8.00
3.33
2.67
±1.67
±1.33
8.00
8.00
3.33
2.67
±1.67
±1.33
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Maximum
Capacitive Load
21000
13000
2000
1500
±1200
±750
21000
13000
2000
1500
±1200
±750
21000
13000
2000
1500
±1200
±750
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
Efficiency
Model Number
90%
91%
91%
91%
91%
92%
91%
92%
91%
92%
91%
92%
91%
92%
91%
92%
92%
92%
JCK4012S3V3
JCK4012S05
JCK4012S12
JCK4012S15
JCK4012D12
JCK4012D15
JCK4024S3V3
JCK4024S05
JCK4024S12
JCK4024S15
JCK4024D12
JCK4024D15
JCK4048S3V3
JCK4048S05
JCK4048S12
JCK4048S15
JCK4048D12
JCK4048D15
Notes
1. Input current specified at nominal input.
2. Cross regulation for duals is ±5% when one output is at 100% and the other is
varied between 25% and 100%.
3. Measured with 1 µF ceramic capacitor in parallel with a 10 µF electrolytic
across output rails.
Mechanical Details
1.0 (25.4)
0.10
(2.54)
0.40
(10.16)
4
DIA.
0.04
(1.00)
0.10
(2.54)
0.40
(10.16)
0.40
(10.16)
Pin
1
2
3
4
5
6
6
5
0.20
(5.0) 0.10
(2.5)
0.10
(2.59)
0.02
(0.50)
Ø 0.04
(1.00)
Bottom View
2.00
(50.80)
PIN CONNECTIONS
Single
Dual
+Vin
+Vin
-Vin
-Vin
Remote On/Off Remote On/Off
+Vout
+Vout
Com
Com
Trim
-Vout
Notes
1.
2.
3.
4.
5.
0.10
(2.54)
0.20
(5.00)
1
2
3
0.20
(5.08)
0.10
(2.54)
0.20
(5.08)
min
0.60 (15.24)
Application Notes
Input Filter
C9
C7
+Vout
L1
+
All dimensions are in inches (mm).
Weight: 0.07 lbs (30 g) approx
Pin diameter: 0.04 ±0.002 (1.0 ±0.05)
Pin pitch tolerance: ±0.014 (±0.35)
Case tolerance: ±0.02 (±0.5)
C1 C2 C3
+Vin
C4 C5 C6
-
DC/DC
Converter
(Single)
Load
Com
-Vin
C8
C8
JCK40 Single
C1
L1
12 V
Common Mode
24 V
220 µF, 100 V
Choke 68 µH
48 V
JCK40 Dual
C1
L1
12 V
Common Mode
24 V
220 µF, 100 V
Choke 68 µH
48 V
JCK40 Single
12 V
24 V
48 V
JCK40 Dual
12 V
24 V
48 V
C7
1000 pF, 2
1000 pF, 2
C7
1000 pF, 2
1000 pF, 2
1000 pF, 2
C2/C3/C5]/C6
6.8 µF, 50 V
4.7 µF, 50 V
1.5 µF, 1000 V
C2/C3/C5/C6
6.8 µF, 50 V
4.7 µF, 50 V
1.5 µF, 1000 V
C8
kV
kV
kV
kV
kV
1000 pF, 2
1000 pF, 2
C8
1000 pF, 2
1000 pF, 2
1000 pF, 2
kV
kV
C4
330 µF, 100 V
220 µF, 100 V
220 µF, 100 V
C4
330 µF, 100 V
220 µF, 100 V
220 µF, 100 V
C9
1000 pF, 2 kV
kV
kV
kV
C7
C1 C2 C3
-
External Output Trim
+Vout
L1
+
+Vin
C4 C5 C6
DC/DC
Converter
(Dual)
-Vin
6
Com
6
Load
R trim-up
R trim-down
-Vout
5
4
Output can be externally
trimmed using this method.
Contact sales for details.
21-Jan-11
DCDC
JCK40
Models and Ratings
Similar pages