RUILON MOV-34S Metal oxide varistor Datasheet

ELECTRONICS
Metal
Oxide
Varistors
34S Series
Circuit Protection
System
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Metal Oxide Varistors - 34S Series
Features
1. Wide operating voltage (V1mA) range from 8V to 1800V.
2. Fast responding to transient over-voltage.
3. Large absorbing transient energy capability.
4. Low clamping ratio and no following-on current.
General Information
The MOV-34SxxxK Series of 34mm radial leaded varistor devices protects against overvoltage transients such as lightning,
power contact and power induction. The metal oxide varistors offer a choice of varistor voltages from 200 V to 1600 V and Vrms
voltages from 130 V to 1000 V. The devices have a high current handling, high energy absorption capability and fast response
times to protect against transient faults up to rated limits.
General Characteristics
No Radioactive Material Storage Temperature: -55ºC to +125ºC
Operating Temperature: -55ºC to +85ºC
Body: Nickel Plated
Leads: Surface-mount, Axial Devices: Tin Plated
Devices with No Leads: Nickel Plated
Product Name
3
4
S
4
7
1
K
Disc Diameter
Type
Nominal Varistor Voltage
Varistor Voltage
Tolerance
34=34MM
D: Disk
471=47*101V
K = 10 %
S: Square
Circuit Protection
System
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Page:1
Metal Oxide Varistors - 34S Series
Electriacl Characteristics
Type Number
Maximum Allowable
Voltage
Varistor Voltage
Maximum
Clamping
Voltage
Withstanding
Surge Current
Maximum
Energy
(10/1000μs)
Typical
Capacitance
(Reference)
VAC(V)
VDC(V)
V1mA(V)
IP(A)
VC(V)
I(A)
(J)
@1KHz(pF)
34S201K
130
170
200(180~220)
300
340
40000
330
8000
34S221K
140
180
220(198~242)
300
360
40000
360
7800
34S241K
150
200
240(216~264)
300
395
40000
390
7600
34S271K
175
225
270(243~297)
300
455
40000
420
7200
34S301K
190
250
300(270~330)
300
500
40000
460
7000
34S331K
210
275
330(297~363)
300
550
40000
500
6400
34S361K
230
300
360(324~396)
300
595
40000
510
6000
34S391K
250
320
390(351~429)
300
650
40000
530
4800
34S431K
275
350
430(387~473)
300
710
40000
600
4600
34S471K
300
385
470(423~517)
300
775
40000
650
4100
34S511K
320
415
510(459~561)
300
845
40000
700
4000
34S561K
350
460
560(504~616)
300
925
40000
730
3800
34S621K
385
505
620(558~682)
300
1025
40000
780
3600
34S681K
420
560
680(612~748)
300
1120
40000
810
3300
34S751K
460
615
750(675~825)
300
1240
40000
850
3000
34S781K
485
640
780(702~858)
300
1290
40000
930
2850
34S821K
510
670
820(738~902)
300
1355
40000
970
2700
34S911K
550
745
910(819~1001)
300
1500
40000
1050
2100
34S951K
575
765
950(855~1045)
300
1570
40000
1080
1900
34S102K
625
825
1000(900~1100)
300
1650
40000
1120
1700
34S112K
680
895
1100(990~1210)
300
1815
40000
1250
1520
34S122K
750
990
1200(1350~1650)
300
1980
40000
1250
1400
34S142K
880
1140
1400(1260~1540)
300
2310
40000
1400
1200
34S162K
1000
1280
1600(1440~1760)
300
2640
40000
1500
1100
Circuit Protection
System
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Page:2
Metal Oxide Varistors - 34S Series
Current Energy and Power Dissipation Ratings
Should transients occur in rapid succession, the average power dissipation is the energy (watt-seconds) per pulse times
the number of pulses per second. The power so developed must be within the specifications shown on the Device Ratings
and Specifications Table for the specific device. The operating values of a MOV need to be derated at high temperatures as
shown above. Because varistors only dissipate a relatively small amount of average power they are not suitable for repetitive
applications that involve substantial amounts of average power dissipation.
Figure 1A - Power Derating for Epoxy Coated
Figure 1B - Power Derating for Pholenic Coated
90
PERCENT OF RATED VALUE
100
90
PERCENT OF RATED VALUE
100
80
70
60
50
40
30
20
80
70
60
50
40
30
20
10
10
0
-55
50
60
70
80
90 100 110 120
AMBIENT TEMPERATURE ( o C)
130
0
-55
140 150
50
60
70
80
90 100 110 120
AMBIENT TEMPERATURE ( o C)
130
140 150
PERCENT OF PEAK VALUE
Peak Pulse Current Test Waveform
100
90
01
T1
T2
Example
8µ
20µ
50
10
O1
Figure 2
T
µs Current Waveform:
1
2
TIME
T1
T2
Packaging
Part Number
Component
Package
Quantity
Packaging
Option
Packaging Specification
34S
34.0
100
BOX
200PCS
Circuit Protection
System
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Page:3
D
Metal Oxide Varistors - 34S Series
Package Dimensions
H
Unit:mm
K
H1
D
d1
D1
H
K
H1
d
d1
D1
TABLE 2
TABLE 1
Symbol
Dimensions
Model
T(max.)
Model
T(max.)
H(max.)
56.3
201K
6.2
621K
8.7
H1(max.)
16.5
221K
6.3
681K
9.0
D(max.)
40.0
241K
6.4
751K
9.4
D1(+1.0)
25.4
271K
6.6
781K
9.6
T(max.)
TABLE 2
301K
6.8
821K
9.8
d(+0.1)
0.5
331K
6.9
911K
10.4
d1(+0.3)
3.4
361K
7.1
951K
10.6
K(max.)
3.18
391K
7.3
102K
11.2
W(+0.5)
7.0
431K
7.5
112K
11.8
Φ(M+0.2)
3.8
471K
7.8
122K
12.3
511K
8.9
142K
13.3
561K
8.3
162K
14.3
Warehouse Storage Conditions of Products
· Storage Conditions:
1. Storage Temperature: -10°C~+40°C
2. Relative Humidity:≤75%RH
3. Keep away from corrosive atmosphere and sunlight.
· Period of Storage: 1 year
Circuit Protection
System
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.
Page:4
RuiLongYuan Electronics Co., Ltd.
· Reproducing and modifying information of the document is prohibited without permission from
Ruilongyuan International Inc.
· Ruilongyuan International Inc. reserves the rights to make changes of the content herein the document anytime
without notification. Please refer to our website for the latest document.
· Ruilongyuan International Inc. disclaims any and all liability arising out of the application or use of any product
including damages incidentally and consequentially occurred.
· Ruilongyuan International Inc. does not assume any and all implied warranties, including warranties of fitness
for particular purpose, non-infringement and merchantability.
· Applications shown on the herein document are examples of standard use and operation. Customers are responsible
in comprehending the suitable use in particular applications.Ruilongyuan International Inc. makes no representation or
warranty that such applications will be suitable for the specifed use without further testing or modifcation.
· The products shown herein are not designed and authorized for equipments requiring high level of reliability or relating to
human life and for any applications concerning life-saving or life-sustaining, such as medical instruments, transportation
equipment,aerospace machinery et cetera. Customers using or selling these products for use in such applications do so at
their own risk and agree to fullyindemnify Ruilongyuan International Inc. for any damages resulting from such improper use or
sale.
Tel: +86-755-8290 8296
Circuit Protection
System
Fax: +86-755-8290 8002
E-mail: [email protected]
Specifications are subject to change without notice.
Please refer to http://www.ruilon.com for current information.