Powerex Power MIG400Q2CMB1X Compact ipm sery Datasheet

MIG400Q2CMB1X
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Compact IPM Series
Dual Module
400 Amperes/1200 Volts
A
D
L
J
N
M
K
W
V
E2
C1
C
DETAIL "A"
H B
C2E1
F E
U
W
T
DD
P
Q
R
S
R
SIGNAL TERMINAL
AA
1
2
3
4
Z
X
FO(L)
GND(L)
IN(L)
VD(L)
5
6
7
8
FO(H)
GND(H)
IN(H)
VD(H)
X
Y
G
1 2 3 4
5 6 7 8
7
8
6
IN
VD
FO
GND
CC
BB
3
OUT
VS
GND
FO
IN
VD
OUT
VS
GND
GND
5
1
CC
4
2
CC
E2
C2/E1
C1
DETAIL "A"
Outline Drawing and Circuit Diagram
Dimensions
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Rev. 8/05
Inches
4.80±0.04
1.97±0.01
1.61±0.03
4.33±0.01
2.44±0.04
3.74±0.02
4.68±0.02
0.6
0.63
0.51
0.24
0.22 Dia.
1.42±0.03
M6 Metric
Millimeters
122.0±1.0
50.0±0.3
41.0±0.8
110.0±0.3
62.0±1.0
95.0±0.5
119.0±0.5
15.24
16.0
13.0
6.0
5.5 Dia.
36.0±0.8
M6
Dimensions
Inches
Millimeters
Q
0.79±0.03
20.0±0.8
R
1.02±0.03
26.0±0.8
S
1.44±0.03
36.7±0.8
T
R6
R6
U
0.025 Sq.
0.64 Sq.
V
0.60
15.3
W
0.41±0.03
10.5±0.8
X
1.02+0.04/-0.01 26.0+1.0/-0.3
Y
0.79±0.03
20.0±0.8
Z
1.48+0.04/-0.02 37.5+1.0/-0.5
AA
0.12 Dia.
3.0 Dia.
BB
1.0±0.024
25.4±0.6
CC
0.1
2.54
DD
0.35
9.0
Description:
Powerex Dual Compact IPM
Series Modules are designed for
use in switching applications. Each
module consists of two IGBT
Transistors in a half-bridge configuration, with each transistor having
a reverse-connected super-fast
recovery free-wheel diode. All
components and interconnects
are isolated from the heat sinking
baseplate, offering simplified
system assembly and thermal
management.
Features:
£ Over-Current and
Over-Temperature Protection
£ Low VCE(sat)
£ Isolated Baseplate for Easy
Heat Sinking
Applications:
£ AC Motor Control
£ Motion/Servo Control
£ UPS
£ Welding Power Supplies
£ Laser Power Supplies
Ordering Information:
MIG400Q2CMB1X is a
1200V (VCES), 400 Ampere
Compact IPM Series Dual Module.
1
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MIG400Q2CMB1X
Compact IPM Series Dual Module
400 Amperes/1200 Volts
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Characteristics
Power Device Junction Temperature
Symbol
MIG400Q2CMB1X
Units
Tj
-20 to 150
°C
Storage Temperature
Tstg
-40 to 125
°C
Operating Temperature
TC
-20 to 100
°C
Mounting Torque, M5 Mounting Screws
—
31
in-lb
Mounting Torque, M6 Terminal Screws
—
40
in-lb
Module Weight (Typical)
—
380
Grams
VISO
2500
Volts
Supply Voltage (P-N Power Terminal)
VCC
900
Volts
Collector-Emitter Voltage
VCES
1200
Volts
IC
400
Amperes
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal
IGBT Inverter Sector
Collector Current (TC = 25°C, DC)
Forward Current (TC = 25°C, DC)
IF
400
Amperes
Collector Power Dissipation (TC = 25°C)
PC
3780
Watts
IGBT Control Sector
2
Control Supply Voltage (VD-GND Terminal)
VD
20
Volts
Input Voltage (IN-GND Terminal)
VIN
20
Volts
Fault Output Voltage (FO-GND (L) Terminal)
VFO
20
Volts
Fault Output Current (FO Sink Current)
IFO
10
mA
Rev. 8/05
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MIG400Q2CMB1X
Compact IPM Series Dual Module
400 Amperes/1200 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
IGBT Inverter Sector
Collector Cut-off Current
Collector-Emitter
ICEX
VCE(sat)
Saturation Voltage
Forward Voltage
VF
VCE = 1200V, Tj = 25°C
—
—
1
mA
VCE = 1200V, Tj = 125°C
—
—
10
mA
VD = 15V, IC = 400A, VIN = 15V to 0V, Tj = 25°C
—
2.4
2.8
Volts
VD = 15V, IC = 400A, VIN = 15V to 0V, Tj = 125°C
—
2.8
—
Volts
IF = 400A, Tj = 25°C
ton
Switching
Time
—
2.4
2.8
Volts
—
2.0
3.0
µs
tc(on)
VCC = 600V, IC = 400A,
—
0.5
—
µs
trr
VD = 15V, VIN = 15V ↔ 0V,
—
0.3
—
µs
toff
Tj = 25°C, Inductive Load
tc(off)
—
1.6
2.5
µs
—
0.3
—
µs
—
13
17
mA
Control Sector
Control Circuit Current
ID(H)
High Side, VD = 15V
ID(L)
Low Side, VD = 15V
—
13
17
mA
Input-ON Signal Voltage
VIN(on)
VD = 15V
1.4
1.6
1.8
Volts
Input-OFF Signal Voltage
VIN(off)
VD = 15V
2.2
2.5
2.8
Volts
Fault Output Current
IFO(on)
Protection Current, VD = 15V
8
10
12
mA
IFO(off)
Normal Current, VD = 15V
—
—
0.1
mA
Over-Current Protection Trip Level
OC
VD = 15V, Tj ≤ 125°C
640
—
—
Amperes
Short-Circuit Current
SC
VD = 15V, Tj ≤ 125°C
640
—
—
Amperes
Protection Trip Level
Over-Current Cut-off Time
toff(OC)
—
—
5
—
µs
Over-Temperature
OT
Trip Level Case Temperature
110
118
125
°C
Protection
OTr
Reset Level Case Temperature
—
98
—
°C
Control Supply Under
UV
Trip Level
11.0
12.0
12.5
Volts
UVr
Reset Level
12.0
12.5
13.0
Volts
td(FO)
VD = 15V
1
2
3
ms
Voltage Protection
Fault Output Pulse Width
Rev. 8/05
3
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MIG400Q2CMB1X
Compact IPM Series Dual Module
400 Amperes/1200 Volts
Thermal Characteristics
Characteristic
Symbol
Condition
Min.
Typ.
Max.
Units
Junction to Case
Rth(j-c)Q
IGBT (Per 1/2 Module)
—
—
0.033
°C/Watt
Thermal Resistance
Rth(j-c)D
FWDi (Per 1/2 Module)
—
—
0.068
°C/Watt
Rth(c-f)
—
—
0.013
—
°C/Watt
Symbol
Condition
Min.
Typ.
Max.
Units
VCC
P-N Power Terminals
—
600
800
Volts
Control Supply Voltage
VD
VD-GND Signal terminal
13.5
15
16.5
Volts
Switching Frequency
fC
PMW Control
—
—
20
kHz
tDEAD
—
5
—
—
µs
Contact Thermal Resistance
Recommended Conditions for Use
Characteristic
Supply Voltage
Dead Time*
*The table lists Dead Time requirements for the module input, excluding photocoupler delays. When specifying Dead Time requirements for the photocoupler input, please add photocoupler
delays to the Dead Time given above.
4
Rev. 8/05
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MIG400Q2CMB1X
Compact IPM Series Dual Module
400 Amperes/1200 Volts
OUTPUT CHARACTERISTICS
(TYPICAL)
900
800
700
VD = 17V
600
15V
13V
500
400
300
200
100
0
1
2
3
4
13V
500
400
300
200
100
0
1
2
3
4
700
600
500
400
300
200
100
0
5
0
1
2
3
TURN-OFF TIME VS.
COLLECTOR CURRENT
(TYPICAL)
TURN-ON TIME VS.
COLLECTOR CURRENT
(TYPICAL)
TURN-OFF DELAY TIME VS.
COLLECTOR CURRENT
(TYPICAL)
100
200
300
400
0
100
200
300
400
SWITCHING TIME, tc(off), (µs)
VCC = 600V
VD = 15V
Tj = 25°C
Tj = 125°C
100
10-1
500
0
100
200
300
400
COLLECTOR CURRENT, IC, (AMPERES)
COLLECTOR CURRENT, IC, (AMPERES)
COLLECTOR CURRENT, IC, (AMPERES)
TURN-ON DELAY TIME VS.
COLLECTOR CURRENT
(TYPICAL)
SWITCHING LOSS (OFF) VS.
COLLECTOR CURRENT
(TYPICAL)
SWITCHING LOSS (ON) VS.
COLLECTOR CURRENT
(TYPICAL)
102
100
100
200
300
400
COLLECTOR CURRENT, IC, (AMPERES)
Rev. 8/05
VCC = 600V
VD = 15V
Tj = 25°C
Tj = 125°C
10-1
500
VCC = 600V
VD = 15V
Tj = 25°C
Tj = 125°C
0
100
500
101
VCC = 600V
VD = 15V
Tj = 25°C
Tj = 125°C
100
500
102
0
100
200
300
400
COLLECTOR CURRENT, IC, (AMPERES)
500
SWITCHING LOSS, Eon, (mJ/PULSE)
0
SWITCHING TIME, ton, (µs)
VCC = 600V
VD = 15V
Tj = 25°C
Tj = 125°C
4
101
101
SWITCHING LOSS, Eoff, (mJ/PULSE)
SWITCHING TIME, toff, (µs)
VD = 17V
FORWARD VOLTAGE, VF, (VOLTS)
101
SWITCHING TIME, tc(on), (µs)
700
600
Tj = 25°C
Tj = 125°C
800
COLLECTOR-EMITTER VOLTAGE, VCE(sat), (VOLTS)
100
10-1
15V
COLLECTOR-EMITTER VOLTAGE, VCE(sat), (VOLTS)
101
10-1
800
0
5
900
Tj = 25°C
FORWARD CURRENT, IF, (AMPERES)
Tj = 25°C
COLLECTOR CURRENT, IC, (AMPERES)
COLLECTOR CURRENT, IC, (AMPERES)
900
0
FREE-WHEEL CHARACTERISTICS
(TYPICAL)
OUTPUT CHARACTERISTICS
(TYPICAL)
101
VCC = 600V
VD = 15V
Tj = 25°C
Tj = 125°C
100
0
100
200
300
400
500
COLLECTOR CURRENT, IC, (AMPERES)
5
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MIG400Q2CMB1X
Compact IPM Series Dual Module
400 Amperes/1200 Volts
103
102
Tj = 25°C
Tj = 125°C
0
100
200
300
400
102
101
500
720
Tj = 25°C
Tj = 125°C
0
OVER CURRENT PROTECTION TRIP LEVEL
VS. CASE TEMPERATURE
(TYPICAL)
CONTROL CIRCUIT CURRENT, ID, (mAMPERES)
1000
800
600
400
200
VD = 15V
0
0
25
50
75
100
125
150
CASE TEMPERATURE, TC, (°C)
100
200
300
400
OC
480
320
160
VD = 15V
Tj ≤ 125°C
0
400
800
1200
1600
FORWARD CURRENT, IF, (AMPERES)
COLLECTOR-EMITTER VOLTAGE, VCE, (VOLTS)
CONTROL CIRCUIT CURRENT VS.
CARRIER FREQUENCY
(TYPICAL)
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(IGBT)
100
60
TC = 25°C
VD = 15V
Tj = 25°C
50
40
30
20
10
0
640
0
500
TRANSIENT IMPEDANCE, Rth(j-c)
OVER CURRENT PROTECTION TRIP LEVEL, OC, (AMPERES)
FORWARD CURRENT, IF, (AMPERES)
1200
COLLECTOR CURRENT, IC, (AMPERES)
103
101
REVERSE BIAS
SAFE OPERATION AREA
(TYPICAL)
REVERSE RECOVERY TIME
(TYPICAL )
REVERSE RECOVERY TIME, trr, (ns)
PEAK REVERSE RECOVERY CURRENT, Irr, (AMPERES)
REVERSE RECOVERY CURRENT
(TYPICAL )
10-1
10-2
10-3
SINGLE PULSE
STANDARD VALUE = Rth(j-c)Q = 0.033°C/W
0
5
10
15
20
CARRIER FREQUENCY, fC, (kHz)
25
10-4
10-3
10-2
10-1
100
101
TIME, (s)
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(FWDi)
100
TRANSIENT IMPEDANCE, Rth(j-c)
TC = 25°C
10-1
10-2
10-3
SINGLE PULSE
STANDARD VALUE = Rth(j-c)D = 0.068°C/W
10-4
10-3
10-2
10-1
100
101
TIME, (s)
6
Rev. 8/05