Models
Single output
Model
Input Voltage
(V)
RoHS compliant
±20% Input voltage range
Low ripple and noise
High efficiency up to 81%
Output
Voltage
(V)
•
•
•
•
Operating temperature -40oC to + 85oC
5KVAC highest reinforced input/ output isolation
Pin compatible with multiple manufacturers
Continuous short circuit protection
Output
Current max
(mA)
Isolation
(VAC)
Max
Capacitive
Load (uF)
Efficiency
(%)
AM4N-0503SH50Z
4-6
3.3
700
5000
470
74
AM4N-0505SH50Z
4-6
5
700
5000
470
78
AM4N-0512SH50Z
4-6
12
291
5000
220
80
AM4N-0515SH50Z
4-6
15
233
5000
220
79
AM4N-1203SH50Z
9.6-14.4
3.3
700
5000
470
76
AM4N-1205SH50Z
9.6-14.4
5
700
5000
470
80
AM4N-1212SH50Z
9.6-14.4
12
291
5000
220
81
AM4N-1215SH50Z
9.6-14.4
15
233
5000
220
81
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Start up time
Absolute Maximum Rating
No Load Input Current
Input reflected current(pk-pk)
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Nominal
Conditions
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
www.aimtec.com
F 051e R12.B
115
mA
mA
Maximum
Units
±2
Continuous
Autorecovery
Typical
570
-40 to +85 (full load without derating)
-55 to +125
Tel: +1 514 620 2722
1 of 4
VAC
MOhm
pF
Maximum
±0.2
±0.5
±0.02
85
10
20MHz Bandwidth
100% load
VDC
Typical
From 10% to 100% Load
Conditions
ms
5000
1000
50
Conditions
Units
VDC
Typical
3 sec
Parameters
Maximum
4-6
9.6-14.4
Capacitors
75
0-7
0-15
80
35
5 Vin
12 Vin
Output Specifications
Voltage accuracy
Short Circuit protection
Short circuit restart
Short Circuit consumption
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Minimum Load Current
Typical
5
12
Maximum
Units
%
W
% of Vin
%
%/oC
mV p-p
% of Max
Units
KHz
o
C
o
C
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM4N-Z
4 Watt | DC-DC Converter
General Specifications (continued)
Parameters
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Conditions
1.5mm from case for
10sec
Typical
100
None
Maximum
Units
o
Natural Convection
95
Non Conductive Black Plastic (UL94V-0 rated)
12.5
1.25 x 0.80 x 0.40 inches 31.75 x 20.32 x 10.16 mm
> 1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
260
C
%/ oC
% RH
g
o
C
Safety Specifications
Parameters
Agency Approvals
Standards
CE
EN 55022 Class A
EN 55024
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
NOTE: also designed to meet IEC 60601-1
Pin Out Specifications
Pin
2
3
11
14
16
22
23
Single
-V Input
-V Input
N.C.
+V Output
-V Output
V+ Input
V+ Input
N.C.: No connection
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM4N-Z
4 Watt | DC-DC Converter
Dimensions
22.86
(0.90)
0.50
(0.02)
3
20.32
(0.80)
2
11
Bottom View
23 22
16
14
5.08
(0.20)
2.54
(0.10)
Printed Face
15.24
(0.60)
31.75
(1.25)
Built-in Stand-offs to
ease PCB cleaning
3.05
(0.12)
10.16
(0.40)
All dimensions are typical: millimeters (inches)
Pin Diameter: 0.50 ± 0.05 (0.02 ± 0.002)
Pin Pitch Tolerance: ± 0.35 (±0.014)
Case Tolerence: ± 0.5 (±0.02)
EMI Solution
C2
L1
+V output
+V input
C1
DC/DC
Converter
-V input
Load
-V output
C3
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM4N-Z
4 Watt | DC-DC Converter
EFT/Surge Solution
+V output
+V input
DC/DC
Converter
C1
-V input
Load
-V output
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages