Sensortechnics BTE0070A0 Pressure transmitter Datasheet

BTE4000 / PTU4000 Series
Pressure transmitters
FEATURES
· 0...-1 to 0...10 bar absolute or gage1,
0...-15 to 0...150 psi gage1
· 0...5 V, 0...10 V, 1...6 V, 4...20 mA output
· Field interchangeable
· Rugged aluminium housing
MEDIA COMPATIBILITY
Wetted materials:
aluminium, silicon, glass
Housing:
Aluminium, protection class IP 65 (according to
DIN EN 60529) respectively NEMA 41
SPECIFICATIONS9,10
ELECTRICAL CONNECTION
Maximum ratings
0...5 V, 0...10 V, 1...6 V output
Supply voltage (reverse polarity protection)2
BTE(M)/PTU4...0, ...1, ...7
BTE(M)/PTU4...4
Maximum load current
BTE(M)/PTU4...0, ...1, ...7
sensor
-55 to 100°C
-40 to 100°C
0 to 50°C
Humidity limits
0 - 100 %RH
Mechanical shock
BTEM4.../PTU4x01..., 05...
50 g
BTE4010.../PTU4150...
all others
December 2008 / 096
sensor
1.4 bar / 20 psi
16 bar / 200 psi
2 x rated pressure
V
GND
4...20 mA output
2g
Proof pressure3
13 ... 30 V
1
Vout
3
-Vs
2
10 mA
Temperature limits
Storage
Operating
Compensated
Vibration (5 to 500 Hz)
+Vs
13...30 V
12...36 V
+Vs
1
N/C
3
-Vs
2
12 ... 36 V
V
RL
GND
1/6
www.sensortechnics.com
BTE4000 / PTU4000 Series
Pressure transmitters
COMMON PERFORMANCE CHARACTERISTICS
(VS = 15 V, tamb = 25°C)
Characteristics
Operating pressure
Thermal effects (0 to 50°C)5
(-20 to 0°C, 50 to 70°C)5
Non-linearity and hysteresis (BSL)6
Repeatability
Long term stability7
Output noise (0 - 1 kHz)
Response time (10 to 90 %)
Power supply rejection
December 2008 / 096
Min.
BTEM40070..
BTEM4P070..
BTEM4N250..
BTEM40350..
BTEM4N350..
BTEM4P350..
BTE4001..
BTE4N01..
BTE4P01..
BTE4002..
BTE4005..
BTE4010..
PTU4001..
PTU4P01..
PTU4005..
PTU4P05..
PTU4015..
PTU4P015..
PTU4030..
PTU4100..
PTU4150
Offset
Span
Offset
Span
Offset
Span
Typ.
0
-70
-25
0
-350
-350
0
-1
-1
0
0
0
0
-1
0
-5
0
-15
0
0
0
Max.
70
70
0
350
0
350
1
0
1
2
5
10
1
1
5
5
15
15
30
100
150
0.04
0.04
0.02
0.02
±0.2
±0.10
±0.5
±0.04
1.0
0.05
0.03
Unit
mbar
bar
p si g
%FSO/°C
±0.50
%FS
ms
%/V
2/6
www.sensortechnics.com
BTE4000 / PTU4000 Series
Pressure transmitters
INDIVIDUAL PERFORMANCE CHARACTERISTICS1
0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
Unit
4.85
-0.15
4.9
9.9
5.0
0
5.0
10.0
5.15
0.15
5.1
10.1
V
Output impedance
6.0
50
Ω
Power consumption (no load)
100
Zero pressure offset
Full scale span4
BTE/PTU4N...
all others
BTE/PTU4N...
all others
mW
0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
Unit
2.35
-0.15
2.4
4.9
2.5
0
2.5
5.0
2.65
0.15
2.6
5.1
V
Output impedance
6.0
50
Ω
Power consumption (no load)
100
Zero pressure offset
Full scale span4
BTE/PTU4N...
all others
BTE/PTU4N...
all others
mW
1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
Unit
3.35
0.85
2.4
4.9
3.5
1.0
2.5
5.0
3.65
1.15
2.6
5.1
V
Output impedance
6.0
50
Ω
Power consumption (no load)
100
Zero pressure offset
Full scale span4
BTE/PTU4N...
all others
BTE/PTU4N...
all others
mW
4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Zero pressure offset
Full scale span4
BTE/PTU4N...
all others
BTE/PTU4N...
all others
Min.
Typ.
Max.
Unit
11.8
3.8
7.9
15.8
12.0
4.0
8.0
16.0
12.2
4.2
8.1
16.2
mA
Output impedance
0.1
Ω
Power consumption (IL = 20 mA)
260
mW
December 2008 / 096
3/6
www.sensortechnics.com
BTE4000 / PTU4000 Series
Pressure transmitters
OUTPUT CHARACTERISTICS
0...5 V output version
0...10 V output version
10
10
Vout
V 9
Vout 9
V
8
8
7
BTE/PTU4P...
7
6
6
BTE/PTU4P...
5
BTE/PTU4N...
4
5
4
3
all others
BTE/PTU4N...
3
all others
2
1
2
1
-100 -80 -60 -40 -20
0 +20 +40 +60 +80 +100 %
operating pressure
1...6 V output version
-100 -80 -60 -40 -20
0 +20 +40 +60 +80 +100 %
operating pressure
4...20 mA output version
10
20
Vout 9
V
8
Iout 18
mA
16
7
14
6
BTE/PTU4P...
12
BTE/PTU4P...
5
10
BTE/PTU4N...
BTE/PTU4N...
4
8
3
all others
6
all others
2
4
1
2
-100 -80 -60 -40 -20
0 +20 +40 +60 +80 +100 %
operating pressure
-100 -80 -60 -40 -20
0 +20 +40 +60 +80 +100 %
operating pressure
LOAD LIMITATION
1200
Ohm
1000
800
600
operating
range
400
200
0
10
December 2008 / 096
20
30 V
Vsupply
4/6
www.sensortechnics.com
BTE4000 / PTU4000 Series
Pressure transmitters
ELECTROMAGNETIC CAPABILITY8
Radiated, radio frequency
electromagnetic field immunity (RFI)
Electrical fast transient /
burst immunity (EFT)
Electrostatic discharge immunity
test (ESD)
Immunity to conducted disturbances
induced by radio-frequency fields
Test conditions
Criterion Interference
EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz
A
<1 %FSO
80 % AMC (1 kHz)
EN61000-4-4: Grade 3, ±2 kV
B
<1 %FSO
EN61000-4-2: Grade 4, ±8 kV, contact discharge
EN61000-4-6: Grade 3, 0.15 to 80 MHz
10 V, 80 % AMC (1 kHz)
B
<1 %FSO
A
<1 %FSO
OUTLINE DRAWING
93.0 (3.66)
12.0
(0.47)
70.0 (2.76)
10.0
(0.39)
18.0
(0.71)
18.0
(0.71)
14.0
(0.55)
30.0
(1.18)
2.0 (0.08)
1
2
vent hole
3/8" BSP
(1/4"-18 NPT
for PTU devices)
3
12.0
(0.47)
mass: typ. 145 g
dimensions in mm (inches)
PIN
Voltage version
Current version
1
+Vs
+Vs
2
-Vs
-Vs
3
Vout
N/C
ca se
ca se
RECOMMENDED ACCESSORY
Plug DIN EN 175301-803 A and profile washer included in delivery.
For a complete connector/cable assembly use order no. ZK000110-x (x=cable lenghts in m).
50
34
Profile washer
M3
31
dimensions in mm
Note: For proper function of all gage devices the gage port must be vented to the atmosphere
through the connector/cable assembly.
December 2008 / 096
5/6
www.sensortechnics.com
BTE4000 / PTU4000 Series
Pressure transmitters
Specification notes:
1. IP 65 protection is given with locked connector only. The package is an all-sealed housing. For proper function, the gage port
is vented to the atmosphere through the connecting cable. Thus, the cable end must have access to the ambient pressure.
2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
4. Full scale span is the algebraic difference between the positive full scale output and offset.
5. Thermal effects tested and guaranteed from 0 to 50°C relative to 25°C. All specifications shown are relative to 25°C.
6. Linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure.
7. Long term stability is the change in output after one year or 1 million pressure cycles.
8. Test are in accordance with EN61000-6-2, April 1999.
9. CE-labelling is in accordance with 89/336/EEC.
10. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
ORDERING INFORMATION
xTx(x)4
BTE(M):
PTU:
(x)xxx
(m)bar calibration
psi calibration
BTE(M)4000 series
001:
0 to 1 bar
N01:
0 to -1 bar
P01:
-1 to +1 bar
002:
0 to 2 bar
005:
0 to 5 bar
010:
0 to 10 bar
0070:
0 to 70 mbar
P070:
-70 to +70 mbar
N250:
0 to -250 mbar
0350:
0 to 350 mbar
N350:
0 to -350 mbar
P350: -350 to +350 mbar
Note:
PTU4000 series
001:
0 to 1 psi
P01:
-1 to +1 psi
005:
0 to 5 psi
P05:
-5 to +5 psi
015:
0 to 15 psi
P15: -15 to +15 psi
030:
0 to 30 psi
100:
0 to 100 psi
150:
0 to 150 psi
x
x
Output signal
0: 0...10 V
1: 1...6 V
4: 4...20 mA
7: 0...5 V
Pressure mode
G: gage pressure1
A: absolute pressure
(available for pressure ranges
from 1 bar/15 psi upwards only)
Other pressure ranges and options are widely available.
Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
December 2008 / 096
6/6
www.sensortechnics.com
Similar pages