TSC FR601 6.0 amps. fast recovery rectifier Datasheet

FR601 THRU FR607
6.0 AMPS. Fast Recovery Rectifiers
Voltage Range
50 to 1000 Volts
Current
6.0 Amperes
R-6
Features
Low forward voltage drop
High current capability
High reliability
High surge current capability
Mechanical Data
Cases: Molded plastic
Epoxy: UL 94V-0 rate flame retardant
Lead: Axial leads, solderable per MILSTD-202, Method 208 guaranteed
Polarity: Color band denotes cathode end
High temperature soldering guaranteed:
260℃/10 seconds/.375”,(9.5mm) lead
lengths at 5 lbs.,(2.3kg) tension
Weight: 1.65 grams
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Symbol FR601 FR602
Type Number
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
Maximum RMS Voltage
VRMS
35
70
Maximum DC Blocking Voltage
VDC
50
100
Maximum Average Forward Rectified
Current .375”(9.5mm) Lead Length
@TA = 55℃
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method )
Maximum Instantaneous Forward Voltage
@ 6.0A
Maximum DC Reverse Current @ TA=25℃
at Rated DC Blocking Voltage @ TA=100℃
Maximum Reverse Recovery Time ( Note 1 )
Typical Junction Capacitance ( Note 2 )
Typical Thermal Resistance ( Note 3 )
FR603 FR604 FR605 FR606 FR607
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
1000
Units
V
V
V
I(AV)
6.0
A
IFSM
200
A
VF
1.2
V
IR
10
200
uA
uA
nS
pF
O
C/W
℃
℃
Trr
150
250
Cj
80
30
RθJA
Operating Temperature Range
TJ
-65 to +150
Storage Temperature Range
TSTG
-65 to +150
Notes:1. Reverse Recovery Test Conditions: IF=0.5A, IR=1.0A, IRR=0.25A
2. Measured at 1 MHz and Applied Reverse Voltage of 4..0 Volts D.C.
3. Mount on Cu-Pad Size 16mm x 16mm on P.C.B.
- 416 -
500
RATINGS AND CHARACTERISTIC CURVES (FR601 THRU FR607)
FIG.2- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
300
PEAK FORWARD SURGE CURRENT. (A)
AVERAGE FORWARD CURRENT AMPERES
FIG.1- MAXIMUM FORWARD CURRENT DERATING
CURVE
8
6
4
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
0.375"(9.5mm)
Lead Length
2
0
0
25
50
75
100
125
150
250
200
8.3ms Single Half Sine Wave
JEDEC Method
150
100
50
0
175
1
5
10
50
100
o
AMBIENT TEMPERATURE. ( C)
NUMBER OF CYCLES AT 60Hz
FIG.3- TYPICAL FORWARD CHARACTERISTICS
FIG.4- TYPICAL JUNCTION CAPACITANCE
1000
700
600
500
JUNCTION CAPACITANCE.(pF)
INSTANTANEOUS FORWARD CURRENT. (A)
500
100
40
10
Tj=25oC
Pulse Width=300 s
1% Duty Cycle
400
300
200
100
60
40
1
2
4
0.1
0.6
6
10
20
REVERSE VOLTAGE. (V)
1
0.8
1.0
1.2
1.4
1.6
1.8
2.0
FORWARD VOLTAGE. (V)
FIG.5- REVERSE RECOVERY TIME CHARACTERISTIC AND TEST CIRCUIT DIAGRAM
50W
NONINDUCTIVE
10W
NONINDUCTIVE
trr
+0.5A
(-)
DUT
(+)
50Vdc
(approx)
(-)
PULSE
GENERATOR
(NOTE 2)
1W
NON
INDUCTIVE
OSCILLOSCOPE
(NOTE 1)
0
-0.25A
(+)
NOTES: 1. Rise Time=7ns max. Input Impedance=
1 megohm 22pf
2. Rise Time=10ns max. Sourse Impedance=
50 ohms
- 417 -
-1.0A
1cm
SET TIME BASE FOR
5/ 10ns/ cm
40
60
100