Crydom DR2220D30U Output ratings up to 30 amps at 200 vdc Datasheet

DIN Rail Mount
Datasheet
DR22 Series
DC Output DIN Rail Mount SSRs
• Output ratings up to 30 Amps at 200 VDC
• Integral heat sink eliminates the need for complex thermal calculations
• DBC substrate for superior thermal performance
• LED input status indicator
• IP20 touch-safe housing
• 1kHz Maximum PWM Frequency
• 3750 VAC optical isolation
• C-UL-US approved
PRODUCT SELECTION
Control Voltage
4-32 VDC
20 A
30 A
DR2220D20U
DR2220D30U
AVAILABLE OPTIONS
Series
DR22
Operating Voltage
20: 1-200 VDC
20
Required for valid part number
D
Rated Load Current
20: 20 Amps
30: 30 Amps
20
Control Voltage
D: 4-32 VDC
U
Terminal Layout
U: Relay Configuration
OUTPUT SPECIFICATIONS (1)
Description
Absolute Maximum Rating [VDC]
Recommended Operating Voltage [VDC]
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Load Current, DC General Use UL508 @ 40°C [ADC]
Load Current, DC Motor Starting UL508 FLA @ 40°C [ADC]
Minimum Load Current [mA] (2)
Maximum Surge Current [ADC] (10ms)
Maximum On-State Voltage Drop @ Rated Current [VDC]
Maximum On-State Resistance [RDS-ON][Ohms]
Maximum Pulse Width Modulation Frequency [Hz] (3)
Motor Rating UL 508 [HP (kW)]: 120 VDC
20 A
30 A
200
1-150
0.1
20
4.1
5
58
0.680
0.034
1000
1/3 (0.25)
200
1-150
0.2
30
5.4
5
86
0.480
0.016
900
1/2 (0.37)
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Maximum Reverse Voltage
Minimum Turn-On Voltage (4)
Must Turn-Off Voltage
Minimum Input Current (for on-state)
Maximum Input Current
Nominal Input Impedance
Maximum Turn-On Time [µsec]
Maximum Turn-Off Time [µsec]
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
DC Control
4-32 VDC
-32 VDC
4 VDC
1 VDC
11 mA
15 mA
Current Regulated
75
100
DIN Rail Mount
Datasheet
GENERAL SPECIFICATIONS (1)
Description
Parameters
Dielectric Strength, Input to Output (50/60Hz)
Dielectric Strength, Input/Output to Case (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Housing Material
Heat Sink Material
Din Rail Clip Material
Hardware Finish
Input Terminal Screw Torque Range (in-lb/Nm)
Load Terminal Screw Torque Range (in-lb/Nm)
Humidity
LED Input Status Indicator
3750 VRMS
2500 VRMS
109 Ohms
8 pF
-40 to 80 °C
-40 to 100 °C
10.5 oz (298 g)
UL94 V-0
Aluminum
Zinc Plated Steel
Nickel Plating
13-15/1.5-1.7
13-15/1.5-1.7
95% non-condensing
Green
INPUT CURRENT INFORMATION
4-32 VDC Input
Input Current (mA)
14
12
10
8
6
4
2
0
0
5
10
15
20
25
30
35
Input Voltage (VDC)
SURGE CURRENT INFORMATION
DR2220D20U
DR2220D30U
200
175
125
Surge Current (Amp)
Surge Current (Amp)
150
100
75
50
25
0
150
125
100
75
50
25
0.1
1
10
100
0
1000
0.1
1
Surge Duration (msec)
Single Pulse *
For Pulse Width Modulation applications select
the curve according to the duty factor and pulse duration as follows:
Duty Factor
=
Pulse Width
Period
* for Single Surge Pulse Tc=40°C ;Tj=175°C
** for Repetitive Surge Pulse Tc=40°C ;Tj=130°C
x100 (%)
10
Surge Duration (msec)
Duty Factor (10%) **
Duty Factor (20%) **
Period
Duty Factor 10%
Duty Factor 20%
Duty Factor 50%
Do not forget to visit us at: www.crydom.com
Pulse
Width
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Duty Factor (50%) **
100
1000
DIN Rail Mount
Datasheet
THERMAL DERATE INFORMATION
DR2220D20U
Single unit (5)
DR2220D30U
Single unit (5)
Multiple units
15
10
5
0
Multiple units
30
Load Current (Amps)
Load Current (Amps)
20
20
30
40
50
60
Ambient Temperature (ºC)
70
25
20
15
10
5
0
80
20
30
40
50
60
Ambient Temperature (ºC)
70
80
EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM
Load can be wired in position A or B inductive loads must be diode suppressed.
+
12
3/A1
+
Load
A
+
Control
Circuit
DC V
-
+
V DC
-
Trigger
Circuit
4/A2
21
Current
Limiter
-
B
Load
Recommended Wire Sizes
Terminal
Configuration
Wire Size
(Solid / Stranded)
Wire Pull-Out
Strength (lb)[N]
Output
Relay “U” suffix
2 x 18 AWG (1 mm2) Stranded
20 [88]
2 x 10 AWG (6 mm ) Stranded
60 [266]
2 x 18 AWG (1 mm2) Stranded
20 [88]
2 x 12 AWG (4 mm2) Stranded
40[177]
Input
Relay “U” suffix
2
MECHANICAL SPECIFICATIONS
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
Protective Earth Connection
1.19
[30.2]
0.39
[9.9]
+3/A1
INPUT
-4/A2
3.00
[76.2]
1.88
[47.8]
3.67
[93.2]
3.54
[90]
10-32
Thread
+1
OUTPUT
-2
0.89
[22.5]
4.59
[116.5]
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Protective Earth (PE) screw type recommended is
10-32 UNC standard not provided with SSR. Through
the use of a DIN rail ground (protective conductor)
terminal block, the DIN rail itself can be used as the
grounding bus bar. In this case, the zinc plated steel
material used for the DIN rail clip of DR22 models,
permits a secure path to ground and avoid the need of
a further PE connection.
DIN Rail Mount
Datasheet
ACCESSORIES
Recommended Accessories
ID Marker
CNLB
CNLN
CNL2
AGENCY APPROVALS, CONFORMANCES AND EMC
E116949
Certification in accordance with:
Certification in accordance with:
United States Standard for Industrial Control Equipment - UL 508 and
Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14.
Electromagnetic Compatibility
Generic
Standard
IEC 61000-6-2
Immunity for
Industrial
Environments
Inmunity Tests
Test Specification
Level
Performance
Electrostatic Discharge
4kV air discharge
Criterion A
IEC 61000-4-2
4kV contact discharge
Criterion A
Fast transients (burst)
Output
2kV, 5kHz, 100kHz Criterion B
IEC 61000-4-4
Input
1kV, 5kHz, 100kHz Criterion B
Surge
IEC 61000-4-5
Output
1kV Line to Line
Criterion B
2kV Line to Earth
Criterion B
GENERAL NOTES
(1) All parameters at 25°C unless otherwise specified.
(2) Low current loads and high ambient temperature can affect turn-on time.
(3) 8 VDC Minimum control voltage. Resistive loads only . Consider switching losses; at maximum frequency reduce to 75% output current.
Recommended suppressor diode connected at load side, see wiring diagram.
(4) Increase minimum voltage by 1 V for operations from -20 to -40°C.
(5) Minimum spacing to obtain max. current is 22.5mm between adjacent units.
Rev. 060216
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
DIN Rail Mount
Datasheet
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
• Disconnect all
power before
installing or
working with
this equipment.
• Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
• Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
• Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
• Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
• Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
• Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
• Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSIONE.
• Spenga tutta
l'alimentazione
che fornisce
questa
apparecchiatura
prima di lavorare
a questa
apparecchiatura
存在电击、
爆炸或电弧
闪烁危险
•
在操作此设
备之前请先
关闭电源。
若不遵守这些说明,
可能会导致严重的
人身伤害甚至死亡。
• Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima
dell’accensione
L'omissione di
queste istruzioni
provocherà la
morte o
lesioni serie
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告
RISK OF MATERIAL DAMAGE AND HOT
ENCLOSURE
RISQUE DE DOMMAGE MATERIEL ET DE
SURCHAUFFE DU BOITIER
GEFAHR VON MATERIALSCHÄDEN UND
GEHÄUSEERHITZUNG
• The product's side panels may be hot, allow
the product to cool before touching.
• Follow proper mounting instructions including
torque values.
• Do not allow liquids or foreign objects to enter
this product.
• Les panneaux latéraux du produit peuvent être
chauds. Laisser le produit refroidir avant de le
toucher.
• Respecter les consignes de montage, et
notamment les couples de serrage.
• Ne pas laisser pénétrer de liquide ni de corps
étrangers à l'intérieur du produit.
• Die Seitenwände können heiß sein. Lassen Sie
das Produkt abkühlen, bevor Sie es berühren.
• Beachten Sie die Montageanweisungen,
• Führen Sie keine Flüssigkeiten oder
Fremdkörper in das Produkt ein.
Le non-respect de cette directive peut entraîner,
Failure to follow these instructions can result in des lésions corporelles graves ou des
serious injury, or equipment damage.
dommages matériels.
Die Nichtbeachtung dieser Anweisung kann
Körperverletzung oder Materialschäden
zur Folge haben.
RIESGO DE DAÑOS MATERIALES Y DE
SOBRECALENTAMIENTO DE LA UNIDAD
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO
CALDO
材料损坏和高温外壳的危险性
• Los paneles laterales del producto pueden
estar calientes. Esperar que el producto se
enfríe antes de tocarlo.
• Respetar las instrucciones de montaje, y en
particular los pares de apretado.
• No dejar que penetren líquidos o cuerpos
extraños en el producto.
• I pannelli laterali dell'apparecchio possono
scottare; lasciar quindi raffreddare il prodotto
prima di toccarlo.
• Seguire le istruzioni di montaggio corrette.
• Non far entrare liquidi o oggetti estranei in questo
apparecchio.
Si no se respetan estas precauciones pueden
producirse graves lesiones, daños materiales.
La mancata osservanza di questa precauzione può
causare gravi rischi per l'incolumità personale o
danni alle apparecchiature.
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
• 产品的一侧面板可能很热,在其冷却前请
不要触碰。
• 遵照正确的安装说明,包括扭矩值。
• 请勿让液体及其他异物进入本产品。
如不能正确执行这些操作说明,
极有可能造成严重人体伤害或者设备的损坏。
DIN Rail Mount
Datasheet
ANNEX - ENVIROMENTAL INFORMATION
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.
Part
Name
Toxic or hazardous Substance and Elements
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr (VI))
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
Semiconductor die
Solder
附件 - 环保信息
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,
电子信息产品污染控制标识要求。
部件
名称
铅
汞
镉
有毒有害物质或元素
六价铬
多溴联苯
(Pb)
(Hg)
(Cd)
(Cr (VI))
半导体芯片
焊接点
50
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
(PBB)