DIN Rail Mount Datasheet DR22 Series DC Output DIN Rail Mount SSRs • Output ratings up to 30 Amps at 200 VDC • Integral heat sink eliminates the need for complex thermal calculations • DBC substrate for superior thermal performance • LED input status indicator • IP20 touch-safe housing • 1kHz Maximum PWM Frequency • 3750 VAC optical isolation • C-UL-US approved PRODUCT SELECTION Control Voltage 4-32 VDC 20 A 30 A DR2220D20U DR2220D30U AVAILABLE OPTIONS Series DR22 Operating Voltage 20: 1-200 VDC 20 Required for valid part number D Rated Load Current 20: 20 Amps 30: 30 Amps 20 Control Voltage D: 4-32 VDC U Terminal Layout U: Relay Configuration OUTPUT SPECIFICATIONS (1) Description Absolute Maximum Rating [VDC] Recommended Operating Voltage [VDC] Maximum Off-State Leakage Current @ Rated Voltage [mA] Load Current, DC General Use UL508 @ 40°C [ADC] Load Current, DC Motor Starting UL508 FLA @ 40°C [ADC] Minimum Load Current [mA] (2) Maximum Surge Current [ADC] (10ms) Maximum On-State Voltage Drop @ Rated Current [VDC] Maximum On-State Resistance [RDS-ON][Ohms] Maximum Pulse Width Modulation Frequency [Hz] (3) Motor Rating UL 508 [HP (kW)]: 120 VDC 20 A 30 A 200 1-150 0.1 20 4.1 5 58 0.680 0.034 1000 1/3 (0.25) 200 1-150 0.2 30 5.4 5 86 0.480 0.016 900 1/2 (0.37) INPUT SPECIFICATIONS (1) Description Control Voltage Range Maximum Reverse Voltage Minimum Turn-On Voltage (4) Must Turn-Off Voltage Minimum Input Current (for on-state) Maximum Input Current Nominal Input Impedance Maximum Turn-On Time [µsec] Maximum Turn-Off Time [µsec] Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DC Control 4-32 VDC -32 VDC 4 VDC 1 VDC 11 mA 15 mA Current Regulated 75 100 DIN Rail Mount Datasheet GENERAL SPECIFICATIONS (1) Description Parameters Dielectric Strength, Input to Output (50/60Hz) Dielectric Strength, Input/Output to Case (50/60Hz) Minimum Insulation Resistance (@ 500 VDC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Housing Material Heat Sink Material Din Rail Clip Material Hardware Finish Input Terminal Screw Torque Range (in-lb/Nm) Load Terminal Screw Torque Range (in-lb/Nm) Humidity LED Input Status Indicator 3750 VRMS 2500 VRMS 109 Ohms 8 pF -40 to 80 °C -40 to 100 °C 10.5 oz (298 g) UL94 V-0 Aluminum Zinc Plated Steel Nickel Plating 13-15/1.5-1.7 13-15/1.5-1.7 95% non-condensing Green INPUT CURRENT INFORMATION 4-32 VDC Input Input Current (mA) 14 12 10 8 6 4 2 0 0 5 10 15 20 25 30 35 Input Voltage (VDC) SURGE CURRENT INFORMATION DR2220D20U DR2220D30U 200 175 125 Surge Current (Amp) Surge Current (Amp) 150 100 75 50 25 0 150 125 100 75 50 25 0.1 1 10 100 0 1000 0.1 1 Surge Duration (msec) Single Pulse * For Pulse Width Modulation applications select the curve according to the duty factor and pulse duration as follows: Duty Factor = Pulse Width Period * for Single Surge Pulse Tc=40°C ;Tj=175°C ** for Repetitive Surge Pulse Tc=40°C ;Tj=130°C x100 (%) 10 Surge Duration (msec) Duty Factor (10%) ** Duty Factor (20%) ** Period Duty Factor 10% Duty Factor 20% Duty Factor 50% Do not forget to visit us at: www.crydom.com Pulse Width Copyright © 2016 Crydom Inc. Specifications subject to change without notice. Duty Factor (50%) ** 100 1000 DIN Rail Mount Datasheet THERMAL DERATE INFORMATION DR2220D20U Single unit (5) DR2220D30U Single unit (5) Multiple units 15 10 5 0 Multiple units 30 Load Current (Amps) Load Current (Amps) 20 20 30 40 50 60 Ambient Temperature (ºC) 70 25 20 15 10 5 0 80 20 30 40 50 60 Ambient Temperature (ºC) 70 80 EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM Load can be wired in position A or B inductive loads must be diode suppressed. + 12 3/A1 + Load A + Control Circuit DC V - + V DC - Trigger Circuit 4/A2 21 Current Limiter - B Load Recommended Wire Sizes Terminal Configuration Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[N] Output Relay “U” suffix 2 x 18 AWG (1 mm2) Stranded 20 [88] 2 x 10 AWG (6 mm ) Stranded 60 [266] 2 x 18 AWG (1 mm2) Stranded 20 [88] 2 x 12 AWG (4 mm2) Stranded 40[177] Input Relay “U” suffix 2 MECHANICAL SPECIFICATIONS Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Protective Earth Connection 1.19 [30.2] 0.39 [9.9] +3/A1 INPUT -4/A2 3.00 [76.2] 1.88 [47.8] 3.67 [93.2] 3.54 [90] 10-32 Thread +1 OUTPUT -2 0.89 [22.5] 4.59 [116.5] Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. Protective Earth (PE) screw type recommended is 10-32 UNC standard not provided with SSR. Through the use of a DIN rail ground (protective conductor) terminal block, the DIN rail itself can be used as the grounding bus bar. In this case, the zinc plated steel material used for the DIN rail clip of DR22 models, permits a secure path to ground and avoid the need of a further PE connection. DIN Rail Mount Datasheet ACCESSORIES Recommended Accessories ID Marker CNLB CNLN CNL2 AGENCY APPROVALS, CONFORMANCES AND EMC E116949 Certification in accordance with: Certification in accordance with: United States Standard for Industrial Control Equipment - UL 508 and Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14. Electromagnetic Compatibility Generic Standard IEC 61000-6-2 Immunity for Industrial Environments Inmunity Tests Test Specification Level Performance Electrostatic Discharge 4kV air discharge Criterion A IEC 61000-4-2 4kV contact discharge Criterion A Fast transients (burst) Output 2kV, 5kHz, 100kHz Criterion B IEC 61000-4-4 Input 1kV, 5kHz, 100kHz Criterion B Surge IEC 61000-4-5 Output 1kV Line to Line Criterion B 2kV Line to Earth Criterion B GENERAL NOTES (1) All parameters at 25°C unless otherwise specified. (2) Low current loads and high ambient temperature can affect turn-on time. (3) 8 VDC Minimum control voltage. Resistive loads only . Consider switching losses; at maximum frequency reduce to 75% output current. Recommended suppressor diode connected at load side, see wiring diagram. (4) Increase minimum voltage by 1 V for operations from -20 to -40°C. (5) Minimum spacing to obtain max. current is 22.5mm between adjacent units. Rev. 060216 Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DIN Rail Mount Datasheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH. • Disconnect all power before installing or working with this equipment. • Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION. • Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. • Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION • Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil • Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION. • Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen • Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSIONE. • Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura 存在电击、 爆炸或电弧 闪烁危险 • 在操作此设 备之前请先 关闭电源。 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。 • Verificare tutti i collegamenti e sostituire tutte le coperture prima dell’accensione L'omissione di queste istruzioni provocherà la morte o lesioni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG • The product's side panels may be hot, allow the product to cool before touching. • Follow proper mounting instructions including torque values. • Do not allow liquids or foreign objects to enter this product. • Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher. • Respecter les consignes de montage, et notamment les couples de serrage. • Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. • Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren. • Beachten Sie die Montageanweisungen, • Führen Sie keine Flüssigkeiten oder Fremdkörper in das Produkt ein. Le non-respect de cette directive peut entraîner, Failure to follow these instructions can result in des lésions corporelles graves ou des serious injury, or equipment damage. dommages matériels. Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben. RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO 材料损坏和高温外壳的危险性 • Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo. • Respetar las instrucciones de montaje, y en particular los pares de apretado. • No dejar que penetren líquidos o cuerpos extraños en el producto. • I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo. • Seguire le istruzioni di montaggio corrette. • Non far entrare liquidi o oggetti estranei in questo apparecchio. Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. • 产品的一侧面板可能很热,在其冷却前请 不要触碰。 • 遵照正确的安装说明,包括扭矩值。 • 请勿让液体及其他异物进入本产品。 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。 DIN Rail Mount Datasheet ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr (VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 部件 名称 铅 汞 镉 有毒有害物质或元素 六价铬 多溴联苯 (Pb) (Hg) (Cd) (Cr (VI)) 半导体芯片 焊接点 50 Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. (PBB) 多溴二苯醚 (PBDE)