ICX076AK Diagonal 3.6mm (Type 1/5) CCD Image Sensor for NTSC Color Video Cameras Description The ICX076AK is an interline CCD solid-state image sensor suitable for NTSC color video cameras. This device possesses a number of pixels that is compatible with SIF, and offers excellent cost performance due to the adoption of an ultra-small image size and a 10 mm-square 14-pin plastic package. High sensitivity and low dark current are achieved through the use of Ye, Cy, Mg, and G complementary color mosaic filters and through the adoption of HAD (Hole-Accumulation Diode) sensors. This chip features a field period readout system and an electronic shutter with variable chargestorage time. 14 pin DIP (Plastic) Features • High sensitivity and low dark current • Low smear • Excellent antiblooming characteristics • Ye, Cy, Mg, and G complementary color mosaic filters on chip • Horizontal register: 5V drive (drive frequency: 6.75MHz) • Reset gate: 5V drive (no adjustment of bias) Device Structure • Image size: • Number of effective pixels: • Total number of pixels: • Interline CCD image sensor • Chip size: • Unit cell size: • Optical black: • Number of dummy bits: • Substrate material: Diagonal 3.6mm (Type 1/5) 362 (H) × 492 (V) approx. 180K pixels 381 (H) × 506 (V) approx. 190K pixels AAAAA AAAAA AAAAA AAAAA AAAAA Pin 1 2 V 2 Pin 8 H 12 17 Optical black position (Top View) 3.75mm (H) × 3.30mm (V) 8.10µm (H) × 4.45µm (V) Horizontal (H) direction: Front 2 pixels, rear 17 pixels Vertical (V) direction: Front 12 pixels, rear 2 pixels Horizontal 14 Vertical 1 (even fields only) Silicon Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits. –1– E95506D99 ICX076AK GND CGG Vφ1 Vφ2 Vφ3 Vφ4 7 6 5 4 3 2 1 Vertical register VOUT Block Diagram and Pin Configuration (Top View) Cy Ye Cy Ye G Mg G Mg Cy Ye Cy Ye G Mg G Mg Cy Ye Cy Ye Mg G Mg G Note) Pin No. Symbol SUB VL Description Note) 12 13 Pin No. : Photo sensor 14 Hφ2 11 Hφ1 10 RG 9 GND Pin Description 8 VDD Horizontal register Symbol Description 1 Vφ4 Vertical register transfer clock 8 VDD Supply voltage 2 Vφ3 Vertical register transfer clock 9 GND GND 3 Vφ2 Vertical register transfer clock 10 SUB Substrate (overflow drain) 4 Vφ1 11 VL Protective transistor bias 5 CGG Vertical register transfer clock Output amplifier gate∗1 12 RG Reset gate clock 6 GND GND 13 Hφ1 Horizontal register transfer clock 7 VOUT Signal output 14 Hφ2 Horizontal register transfer clock ∗1 DC bias is applied within the CCD, so that this pin should be grounded externally through a capacitance of 1µF or more. Absolute Maximum Ratings Item Ratings Unit –0.3 to +55 V VDD, VOUT, CGG – GND –0.3 to +18 V VDD, VOUT, CGG – SUB –55 to +12 V Vφ1, Vφ2, Vφ3, Vφ4 – GND –15 to +20 V Vφ1, Vφ2, Vφ3, Vφ4 – SUB to +12 V Voltage difference between vertical clock input pins to +15 V Voltage difference between horizontal clock input pins to +17 V Hφ1, Hφ2 – Vφ4 –17 to +17 V Hφ1, Hφ2 – GND –10 to +15 V Hφ1, Hφ2 – SUB –55 to +10 V VL – SUB –65 to +0.3 V Vφ1, Vφ3, VDD, VOUT – VL –0.3 to +27.5 V RG – GND –0.3 to +22.5 V Vφ2, Vφ4, CGG, Hφ1, Hφ2, GND – VL –0.3 to +17.5 V Storage temperature –30 to +80 °C Operating temperature –10 to +60 °C Substrate voltage SUB – GND Supply voltage Clock input voltage ∗2 +27V (Max.) when clock width < 10µs, clock duty factor < 0.1%. ∗3 When CGG or GND (Pin 6) are grounded. –0.3 to + 17.5V when CGG and GND (Pin 6) are to be disconnected. –2– Remarks ∗2 ∗3 ICX076AK Bias Conditions Item Symbol Min. Typ. Max. Supply voltage VDD 14.25 15.0 15.75 V Substrate voltage adjustment range VSUB 5.0 12.75 V Indicated voltage + 0.1 V Indicated voltage – 0.1 Substrate voltage adjustment precision Protective transistor bias Indicated voltage Unit Remarks ∗1 ∗2 VL DC Characteristics Item Symbol Min. Typ. Max. Unit 3 5 mA Remarks Supply current IDD Input current IIN1 1 µA ∗3 Input current IIN2 10 µA ∗4 ∗1 Indications of substrate voltage (VSUB) setting value The setting value of the substrate voltage is indicated on the back of image sensor by a special code. Adjust the substrate voltage (VSUB) to the indicated voltage. VSUB code – one character indication ↑ VSUB code Code and optimal setting correspond to each other as follows. VSUB code Optimal setting VSUB code – = 0 1 2 3 4 5.0 5.25 5.5 5.75 6.0 6.25 6.5 E f G h J K L 9.0 9.25 9.5 Y Z Optimal setting 8.5 8.75 VSUB code W Optimal setting X 6 7 8 6.75 7.0 7.25 m N P 9 A 7.5 7.75 R S C d 8.0 8.25 U V 9.75 10.0 10.25 10.5 10.75 11.0 11.25 11.5 11.75 12.0 12.25 12.5 12.75 <Example> “L” → VSUB = 10.0V ∗2 VL setting is the VVL voltage of the vertical transfer clock waveform, or the same power supply as the VL power supply for the V driver should be used. ∗3 1) Current to each pin when 16V is applied to VDD, VOUT, RG, CGG, GND (Pin 6), and SUB pins, while pins that are not tested are grounded. 2) Current to each pin when 20V is applied sequentially to Vφ1, Vφ2, Vφ3, and Vφ4 pins, while pins that are not tested are grounded. However, 20V is applied to SUB pin. 3) Current to each pin when 15V is applied sequentially to Hφ1 and Hφ2 pins, while pins that are not tested are grounded. However, 15V is applied to SUB pin. 4) Current to VL pin when 25V is applied to Vφ1, Vφ3, VDD, and VOUT pins or when, 15V is applied to Vφ2, Vφ4, Hφ1, and Hφ2 pins, while VL pin is grounded. However, GND and SUB pins are left open. 5) Current to GND pin when 20V is applied to the RG pin and the GND pin is grounded. ∗4 Current to SUB pin when 55V is applied to SUB pin, while all pins that are not tested are grounded. –3– ICX076AK Clock Voltage Conditions Item Readout clock voltage Vertical transfer clock voltage Horizontal transfer clock voltage Min. Typ. Max. Unit Waveform diagram VVT 14.25 15.0 15.75 V 1 VVH1, VVH2 –0.05 0 0.05 V 2 VVH3, VVH4 –0.2 0 0.05 V 2 VVL1, VVL2, VVL3, VVL4 –8.5 –8.0 –7.5 V 2 VVL = (VVL3 + VVL4)/2 VφV 7.3 8.0 8.55 V 2 VφV = VVHn – VVLn (n = 1 to 4) Symbol VVH = (VVH1 + VVH2)/2 VVH3 – VVH –0.25 0.1 V 2 VVH4 – VVH –0.25 0.1 V 2 VVHH 0.3 V 2 High-level coupling VVHL 0.3 V 2 High-level coupling VVLH 0.3 V 2 Low-level coupling VVLL 0.3 V 2 Low-level coupling VφH 4.75 5.0 5.25 V 3 VHL –0.05 0 0.05 V 3 4.5 5.0 5.5 V 4 Input through 0.01µF capacitance 0.8 V 4 Low-level coupling V 4 V 5 VφRG Reset gate clock voltage Remarks VRGLH – VRGLL VRGH Substrate clock voltage VφSUB VDD + 0.3 VDD + 0.6 VDD + 0.9 21.25 22.5 –4– 23.75 ICX076AK Clock Equivalent Circuit Constant Item Min. Symbol Typ. Max. Unit CφV1, CφV3 520 pF CφV2, CφV4 390 pF CφV12, CφV34 220 pF CφV23, CφV41 150 pF CφV13, CφV24 39 pF Capacitance between horizontal transfer clock and GND CφH1, CφH2 24 pF Capacitance between horizontal transfer clocks CφHH 18 pF Capacitance between reset gate clock and GND CφRG 3 pF Capacitance between substrate clock and GND CφSUB 170 pF Vertical transfer clock series resistor R1, R2, R3, R4 100 Ω Vertical transfer clock ground resistor RGND 15 Ω Horizontal transfer clock series resistor RφH 30 Ω Reset gate clock series resistor RφRG 39 Ω Capacitance between vertical transfer clock and GND Capacitance between vertical transfer clocks Vφ1 Remarks Vφ2 CφV12 R1 R2 RφH RφH Hφ1 CφV1 CφV41 CφV24 R4 Hφ2 CφHH CφV2 CφV23 CφH1 CφH2 CφV13 CφV4 RGND CφV3 CφV34 Vφ4 R3 Vφ3 Vertical transfer clock equivalent circuit Horizontal transfer clock equivalent circuit RφRG RGφ CφRG Reset gate clock equivalent circuit –5– ICX076AK Drive Clock Waveform Conditions (1) Readout clock waveform 100% 90% II II φM VVT φM 2 10% 0% tr twh 0V tf (2) Vertical transfer clock waveform Vφ1 Vφ3 VVHH VVH1 VVHH VVH VVHL VVHL VVH3 VVHL VVL1 VVH VVHH VVHH VVHL VVL3 VVLH VVLH VVLL VVLL VVL VVL Vφ2 Vφ4 VVHH VVHH VVH VVH VVHH VVHH VVHL VVH2 VVHL VVHL VVH4 VVL2 VVL VVLH VVLH VVLL VVLL VVH = (VVH1 + VVH2)/2 VVL = (VVL3 + VVL4)/2 VφV = VVHn – VVLn (n = 1 to 4) VVHL VVL4 –6– VVL ICX076AK (3) Horizontal transfer clock waveform tr twh tf 90% twl VφH 10% VHL (4) Reset gate clock waveform tr twh tf VRGH twl RG waveform Point A VφRG VRGL + 0.5V VRGLH VRGL VRGLL Hφ1 waveform 10% VRGLH is the maximum value and VRGLL is the minimum value of the coupling waveform during the period from Point A in the above diagram until the rising edge of RG. In addition, VRGL is the average value of VRGLH and VRGLL. VRGL = (VRGLH + VRGLL) /2 Assuming VRGH is the minimum value during the interval twh, then: VφRG = VRGH – VRGL –7– ICX076AK (5) Substrate clock waveform 100% 90% φM VφSUB VSUB 10% 0% tr twh φM 2 tf Clock Switching Characteristics Item Symbol Readout clock VT Vertical transfer clock Vφ1, Vφ2, Vφ3, Vφ4 Hφ Horizontal transfer clock 2.3 2.5 φSUB tf 0.5 0.5 55 67 55 67 5.6 25 34 9 18 7 0.007 0.007 5.6 0.007 0.007 107 8 5 1.5 1.65 0.5 Unit µs Remarks During readout 250 ns ∗1 15 Hφ2 Substrate clock tr Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Hφ1 Reset gate clock φRG twl twh 18 ns During imaging µs During parallel-serial µs conversion ns During drain 0.5 µs charge ∗1 When vertical transfer clock driver CXD1267 is used. tr and tf are defined by the rise and fall times for 10% to 90% of the interval between VVL and VVH. –8– ICX076AK Image Sensor Characteristics (Ta = 25°C) Unit Measurement method mV 1 mV 2 0.012 % 3 SHy 25 % 4 ∆Sr 10 % 5 ∆Sb 10 % 5 Dark signal Ydt 2 mV 6 Ta = 60°C Dark signal shading ∆Ydt 1 mV 7 Ta = 60°C Flicker Y Fy 5 % 8 Flicker R-Y Fcr 5 % 8 Flicker B-Y Fcb 5 % 8 Line crawl R Lcr 3 % 9 Line crawl G Lcg 3 % 9 Line crawl B Lcb 5 % 9 Line crawl W Lcw 3 % 9 Lag Lag 0.5 % 10 Symbol Min. Typ. Sensitivity S 285 360 Saturation signal Ysat 700 Smear Sm Video signal shading Item Uniformity between video signal channels Max. 0.007 Remarks Ta = 60°C Zone II’ Zone Definition of Video Signal Shading 362 (H) 4 4 8 492 (V) 8 Zone II' Ignored region Effective pixel region Measurement System [∗Y] [∗A] CCD signal output Y signal output LPF1 (3dB down 4MHz) CCD C.D.S AMP S [∗C] H LPF2 S H Chroma signal output (3dB down 1MHz) Note) Adjust the amplifier gain so that the gain between [∗A] and [∗Y], and between [∗A] and [∗C] equals 1. –9– ICX076AK Image Sensor Characteristics Measurement Method Measurement conditions 1) In the following measurements, the substrate voltage is set to the value indicated on the device, and the device drive conditions are at the typical values of the bias and clock voltage conditions. 2) In the following measurements, spot blemishes are excluded and, unless otherwise specified, the optical black level (OB) is used as the reference for the signal output, which is taken as the value of Y signal output or chroma signal output of the measurement system. Color coding of this image sensor & Composition of luminance (Y) and chroma (color difference) signals Cy Ye Cy Ye G Mg G Mg Cy Ye Cy Ye Mg G Mg G A1 B A2 As shown in the left figure, fields are read out. The charge is mixed by pairs such as A1 and A2 in the A field (pairs such as B in the B field). As a result, the sequence of charges output as signals from the horizontal shift register (Hreg) is, for line A1, (G + Cy), (Mg + Ye), (G + Cy), and (Mg + Ye). Hreg Color Coding Diagram These signals are processed to form the Y signal and chroma (color difference) signal. The Y signal is formed by adding adjacent signals, and the chroma signal is formed by subtracting adjacent signals. In other words, the approximation: Y = {(G + Cy) + (Mg + Ye)} × 1/2 = 1/2 {2B + 3G + 2R} is used for the Y signal, and the approximation: R – Y = {(Mg + Ye) – (G + Cy)} = {2R – G} is used for the chroma (color difference) signal. For line A2, the signals output from Hreg in sequence are (Mg + Cy), (G + Ye), (Mg + Cy), (G + Ye). The Y signal is formed from these signals as follows: Y = {(G + Ye) + (Mg + Cy)} × 1/2 = 1/2 {2B + 3G + 2R} This is balanced since it is formed in the same way as for line A1. In a like manner, the chroma (color difference) signal is approximated as follows: – (B – Y) = {(G + Ye) – (Mg + Cy)} = – {2B – G} In other words, the chroma signal can be retrieved according to the sequence of lines from R – Y and – (B – Y) in alternation. This is also true for the B field. – 10 – ICX076AK Definition of standard imaging conditions 1) Standard imaging condition I: Use a pattern box (luminance 706cd/m2, color temperature of 3200K halogen source) as a subject. (Pattern for evaluation is not applicable.) Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter and image at F5.6. The luminous intensity to the sensor receiving surface at this point is defined as the standard sensitivity testing luminous intensity. 2) Standard imaging condition II: Image a light source (color temperature of 3200K) with a uniformity of brightness within 2% at all angles. Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter. The luminous intensity is adjusted to the value indicated in each testing item by the lens diaphragm. 1. Sensitivity Set to standard imaging condition I. After selecting the electronic shutter mode with a shutter speed of 1/250s, measure the Y signal (Ys) at the center of the screen and substitute the value into the following formula. S = Ys × 250 [mV] 60 2. Saturation signal Set to standard imaging condition II. After adjusting the luminous intensity to 10 times the intensity with average value of the Y signal output, 200mV, measure the minimum value of the Y signal. 3. Smear Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity to 500 times the intensity with the average value of the Y signal output, 200mV. When the readout clock is stopped and the charge drain is executed by the electronic shutter at the respective H blankings, measure the maximum value (YSm [mV]) of the Y signal output and substitute the value into the following formula. Sm = 1 YSm 1 × × × 100 [%] (1/10V method conversion value) 10 200 500 4. Video signal shading Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity so that the average value of the Y signal output is 200mV. Then measure the maximum (Ymax [mV]) and minimum (Ymin [mV]) values of the Y signal and substitute the values into the following formula. SHy = (Ymax – Ymin)/200 × 100 [%] 5. Uniformity between video signal channels Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal output is 200mV, and then measure the maximum (Crmax, Cbmax [mV]) and minimum (Crmin, Cbmin [mV]) values of the R – Y and B – Y channels of the chroma signal and substitute the values into the following formula. ∆Sr = I (Crmax – Crmin)/200 I × 100 [%] ∆Sb = I (Cbmax – Cbmin)/200 I × 100 [%] 6. Dark signal Measure the average value of the Y signal output (Ydt [mV]) with the device ambient temperature 60°C and the device in the light-obstructed state, using the horizontal idle transfer level as a reference. – 11 – ICX076AK 7. Dark signal shading After measuring 6, measure the maximum (Ydmax [mV]) and minimum (Ydmin [mV]) values of the Y signal output and substitute the values into the following formula. ∆Ydt = Ydmax – Ydmin [mV] 8. Flicker 1) Fy Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal output is 200mV, and then measure the difference in the signal level between fields (∆Yf [mV]). Then substitute the value into the following formula. Fy = (∆Yf/200) × 100 [%] 2) Fcr, Fcb Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal output is 200mV, insert an R or B filter, and then measure both the difference in the signal level between fields of the chroma signal (∆Cr, ∆Cb) as well as the average value of the chroma signal output (CAr, CAb). Substitute the values into the following formula. Fci = (∆Ci/CAi) × 100 [%] (i = r, b) 9. Line crawls Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal output is 200mV, and then insert a white subject and R, G, and B filters and measure the difference between Y signal lines for the same field (∆Ylw, ∆Ylr, ∆Ylg, ∆Ylb [mV]). Substitute the values into the following formula. Lci = (∆Yli/200) × 100 [%] (i = w, r, g, b) 10. Lag Adjust the Y signal output value generated by strobe light to 200mV. After setting the strobe light so that it strobes with the following timing, measure the residual signal (Ylag). Substitute the value into the following formula. Lag = (Ylag/200) × 100 [%] FLD SG1 Light Strobe light timing Y signal output 200mV Output – 12 – Ylag (lag) CXD1267 15 14 13 5 6 7 8 9 10 XV2 XV1 XSG1 XV3 XSG2 XV4 RG Hφ1 Hφ2 17 4 XSUB 22/20V 18 11 12 16 19 2 22/16V 1/35V 1/20V 0.1 0.01 9 14 13 12 11 10 ICX076 ( BOTTOM VIEW ) 7 6 5 4 3 2 1 1/10V Vφ4 100k Hφ1 3 Vφ3 Hφ2 100k Vφ2 RG VSUB 0.1 Vφ1 20 CGG SUB VL 1 GND 15V VOUT GND – 13 – 8 3.3/20V VDD Drive Circuit 0.01 2SK523 1500p 3.9k 100 3.3/16V 1M CCD OUT [∗A] –8V ICX076AK ICX076AK Spectral Sensitivity Characteristics (excludes lens characteristics and light source characteristics) 1.0 Ye 0.8 Cy Relative Response G 0.6 0.4 Mg 0.2 0.0 400 450 500 550 600 650 700 Wave Length [nm] Sensor Readout Clock Timing Chart HD V1 2.5 V2 Odd Field V3 V4 1.3 38.1 1.6 2.5 2.1 0.3 V1 V2 Even Field V3 V4 Unit: µs – 14 – – 15 – CLP1 CCD OUT V4 V3 V2 V1 SG2 SG1 HD VD FLD 4 6 5 7 2 1 3 491 492 Drive Timing Chart (Vertical Sync) 491 490 492 1 9 8 10 3 5 7 2 4 6 ICX076AK – 16 – SUB CLP1 V4 V3 V2 V1 SHD SHP RG H2 H1 HD 10 362 1 Drive Timing Chart (Horizontal Sync) ICX076AK 20 10 1 10 1 17 ICX076AK Notes on Handling 1) Static charge prevention CCD image sensors are easily damaged by static discharge. Before handling be sure to take the following protective measures. a) Either handle bare handed or use non-chargeable gloves, clothes or material. Also use conductive shoes. b) When handling directly use an earth band. c) Install a conductive mat on the floor or working table to prevent the generation of static electricity. d) Ionized air is recommended for discharge when handling CCD image sensor. e) For the shipment of mounted substrates, use boxes treated for the prevention of static charges. 2) Soldering a) Make sure the package temperature does not exceed 80°C. b) Solder dipping in a mounting furnace causes damage to the glass and other defects. Use a ground 30W soldering iron and solder each pin in less than 2 seconds. For repairs and remount, cool sufficiently. c) To dismount an image sensor, do not use a solder suction equipment. When using an electric desoldering tool, use a thermal controller of the zero cross On/Off type and connect it to ground. 3) Dust and dirt protection Image sensors are packed and delivered by taking care of protecting its glass plates from harmful dust and dirt. Clean glass plates with the following operation as required, and use them. a) Perform all assembly operations in a clean room (class 1000 or less). b) Do not either touch glass plates by hand or have any object come in contact with glass surfaces. Should dirt stick to a glass surface, blow it off with an air blower. (For dirt stuck through static electricity ionized air is recommended.) c) Clean with a cotton bud and ethyl alcohol if the grease stained. Be careful not to scratch the glass. d) Keep in a case to protect from dust and dirt. To prevent dew condensation, preheat or precool when moving to a room with great temperature differences. e) When a protective tape is applied before shipping, just before use remove the tape applied for electrostatic protection. Do not reuse the tape. 4) Installing (attaching) a) Remain within the following limits when applying a static load to the package. Do not apply any load more than 0.7mm inside the outer perimeter of the glass portion, and do not apply any load or impact to limited portions. (This may cause cracks in the package.) AAAA AAAA AAAA AAAA AAAA AAAA Cover glass 50N 50N 1.2Nm Plastic package Compressive strength Torsional strength b) If a load is applied to the entire surface by a hard component, bending stress may be generated and the package may fracture, etc., depending on the flatness of the bottom of the package. Therefore, for installation, use either an elastic load, such as a spring plate, or an adhesive. – 17 – ICX076AK c) The adhesive may cause the marking on the rear surface to disappear, especially in case the regulated voltage value is indicated on the rear surface. Therefore, the adhesive should not be applied to this area, and indicated values should be transferred to the other locations as a precaution. d) The notch of the package is used for directional index, and that can not be used for reference of fixing. In addition, the cover glass and seal resin may overlap with the notch of the package. e) If the lead bend repeatedly and the metal, etc., clash or rub against the package, the dust may be generated by the fragments of resin. f) Acrylate anaerobic adhesives are generally used to attach CCD image sensors. In addition, cyanoacrylate instantaneous adhesives are sometimes used jointly with acrylate anaerobic adhesives. (reference) 5) Others a) Do not expose to strong light (sun rays) for long periods, color filters will be discolored. When high luminance objects are imaged with the exposure level control by electronic-iris, the luminance of the image-plane may become excessive and discolor of the color filter will possibly be accelerated. In such a case, it is advisable that taking-lens with the automatic-iris and closing of the shutter during the power-off mode should be properly arranged. For continuous using under cruel condition exceeding the normal using condition, consult our company. b) Exposure to high temperature or humidity will affect the characteristics. Accordingly avoid storage or usage in such conditions. c) The brown stain may be seen on the bottom or side of the package. But this does not affect the CCD characteristics. d) This package has 2 kinds of internal structure. However, their package outline, optical size, and strength are the same. Structure A Structure B AAA Package Chip Metal plate (lead frame) Cross section of lead frame The cross section of lead frame can be seen on the side of the package for structure A. – 18 – 1.0 2.5 0.5 – 19 – 1.7 7 1 14 8. The thickness of the cover glass is 0.75mm, and the refractive index is 1.5. 9. The notch of the package is used only for directional index, that must not be used for reference of fixing. 42 ALLOY 0.6g LEAD MATERIAL PACKAGE WEIGHT 7. The tilt of the effective image area relative to the bottom “C” is less than 40µm. The tilt of the effective image area relative to the top “D” of the cover glass is less than 40µm. 6. The height from the bottom “C” to the effective image area is 1.41 ± 0.10mm. The height from the top of the cover glass “D” to the effective image area is 1.94 ± 0.15mm. 5. The rotation angle of the effective image area relative to H and V is ± 1°. 4. The center of the effective image area relative to “B” and “B'” is (H, V) = (5.0, 5.0) ± 0.15mm. 3. The bottom “C” of the package, and the top of the cover glass “D” are the height reference. 2. The two points “B” of the package are the horizontal reference. The point “B'” of the package is the vertical reference. 1. “A” is the center of the effective image area. C 8 GOLD PLATING 0.46 0.3 B' 3.35 ± 0.15 LEAD TREATMENT M 2.5 7 D 10.16 Plastic 0.3 7.0 8.9 10.0 ± 0.1 H 8 0° to 9° 0.25 14 pin DIP (400mil) 1.7 PACKAGE MATERIAL 1.27 1 V 14 5.0 1.0 2.5 7.0 A 8.9 10.0 ± 0.1 2.6 Unit: mm 5.0 PACKAGE STRUCTURE B ~ 1.27 3.5 ± 0.3 ~ ~ Package Outline ICX076AK