Vitec MTDA40A-S08 40w desktop power supply for i.t. equipment Datasheet

MTDA40A SERIES
40W Desktop Power Supply for I.T. Equipment






1 Year Warranty
Wide Input Voltage 90 to 264 VAC, 47 to 63Hz
IEC-320-C14 Input Inlet
Output Voltage Available From 5VDC Thru 48VDC
Single Output
Class I Insulation
Energy Star 2.0, CEC V, and RoHS compliance
Approvals:
Single Output
Product Number
Output Voltage
Max. Output Current
Total Regulation
Maximum Output Power
5.00 A
5.00 ~ 3.75 A
4.375 ~ 3.18 A
3.64 ~ 3.07 A
3.07 ~ 2.50 A
2.50 ~ 1.90 A
1.90 ~ 1.48 A
1.48 ~ 1.21 A
1.21 ~ 1.00 A
1.00 ~ 0.83 A
5%
5%
5%
5%
5%
5%
3%
3%
2%
2%
30W
30W
35W
40W
40W
40W
40W
40W
40W
40W
MTDA40A-S02
5 ~ 5.99 VDC
MTDA40A-S03
6.5 ~ 8 VDC
MTDA40A-S04
8 ~ 11 VDC
MTDA40A-S05
11 ~ 13 VDC
MTDA40A-S06
13 ~ 16 VDC
MTDA40A-S07
16 ~ 21 VDC
MTDA40A-S08
21 ~ 27 VDC
MTDA40A-S09
27 ~ 33 VDC
MTDA40A-S10
33 ~ 40 VDC
MTDA40A-S11
40 ~ 48 VDC
Total Regulation is conditioned by below configuration
(S02~S05: AWG16/4FT output cable)
(S06~S08: AWG18/4FT output cable)
(S09~S11: AWG18/6FT output cable)
Electrical Characteristics
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Transient Response
Hold-Up Time
Start Up Time
Ripple & Noise (Peak to Peak)
Safety Ground Leakage Current
Temperature Coefficient
No-load Power Consumption
Test Conditions
Universal Input Voltage
Operating Voltage
Vin=100 to 240VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25°C, Cool start, Vin=115VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
Vin=230VAC
Min.
Typ.
100
90
47
0
83
40
80
87
0.5
3
Nil
110
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=230VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
Io=Full Load, Vin=240VAC
All output
No load, Vin=240VAC
Max.
Unit
240
264
63
40
0.8
0.52
45
90
90
1
7
VAC
VAC
Hz
W
A
A
A
A
%
%
%
%
%
mS
mS
S
%
mA
%/°C
W
150
4
10
2
0.5
0.5
-0.04
0.2
3
1
0.75
0.04
0.3
Conditions
Parameter
Test Conditions
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F
Min.
Typ.
Max.
Unit
0
-40
0
0
0.1M
40
70
85
95
75
°C
°C
%
%
Hrs
Min.
Unit
4242
2121
50
B
B
VDC
VDC
MΩ
CLASS
CLASS
Approvals and Compliance
Parameter
Test Conditions
Dielectric Withstanding Voltage for Primary to secondary
Dielectric Withstanding Voltage for Primary to Ground
Isolation Resistance
EMI requirements for CISPR-22
EMI requirements for FCC PART-15
Primary to secondary
Primary to ground
Test Voltage=500VDC
Vin=220VAC
Vin=110VAC
Mechanical and PIN out
Note:
1.
Dimensions are shown in mm.
2.
Weight: 265~280g approx.
3.
Optional output connector.
Similar pages