IEU03 Series DC-DC Converter 3 Watt xxx Series • Regulated Single & Dual Output • 2:1 Input Range • Compact DIP8 Package • 1500 VDC Isolation • Operating Temperature -40 °C to +95 °C • ITE Safety Approvals • Full Load at 70 °C • Class A Conducted & Radiated Emissions • 3 Year Warranty Dimensions: IEU03: 0.55 x 0.55 x 0.31” (14.0 x 14.0 x 8.0 mm) Models & Ratings Input voltage 4.5-10V 9-18V 18-36V 36-75V Output voltage Output current 3V3 600 mA 5V 600 mA 12 V 250 mA 15 V 200 mA ±5 V ±300 mA Input current(1) No load Full load 45 mA Maximum capacitive load(2) Efficiency Model number 500 mA 100 µF 79% IEU0305S3V3 740 mA 100 µF 81% IEU0305S05 705 mA 100 µF 85% IEU0305S12 705 mA 100 µF 85% IEU0305S15 770 mA ±100 µF 82% IEU0305D05 IEU0305D12 ±12 V ±125 mA 715 mA ±100 µF 84% ±15 V ±100 mA 705 mA ±100 µF 85% IEU0305D15 3V3 600 mA 205 mA 100 µF 80% IEU0312S3V3 5V 600 mA 300 mA 100 µF 83% IEU0312S05 12 V 250 mA 285 mA 100 µF 87% IEU0312S12 15 V 200 mA 285 mA 100 µF 87% IEU0312S15 ±5 V ±300 mA 300 mA ±100 µF 84% IEU0312D05 ±12 V ±125 mA 290 mA ±100 µF 86% IEU0312D12 ±15 V ±100 mA 285 mA ±100 µF 87% IEU0312D15 3V3 600 mA 105 mA 100 µF 80% IEU0324S3V3 27 mA 5V 600 mA 150 mA 100 µF 83% IEU0324S05 12 V 250 mA 145 mA 100 µF 87% IEU0324S12 15 V 200 mA 145 mA 100 µF 87% IEU0324S15 ±5 V ±300 mA 150 mA ±100 µF 84% IEU0324D05 ±12 V ±125 mA 145 mA ±100 µF 86% IEU0324D12 ±15 V ±100 mA 145 mA ±100 µF 87% IEU0324D15 3V3 600 mA 52 mA 100 µF 79% IEU0348S3V3 16 mA 5V 600 mA 76 mA 100 µF 82% IEU0348S05 12 V 250 mA 73 mA 100 µF 86% IEU0348S12 15 V 200 mA 73 mA 100 µF 86% IEU0348S15 ±5 V ±300 mA 76 mA ±100 µF 82% IEU0348D05 ±12 V ±125 mA 74 mA ±100 µF 85% IEU0348D12 ±15 V ±100 mA 74 mA ±100 µF 85% IEU0348D15 10 mA Notes 1. Input currents measured at nominal input voltage. 2. Maximum capacitive load is per output. 1 www.xppower.com IEU03 Series DC-DC Converter Input Characteristic Minimum Typical Maximum 4.5 Input Voltage Range Input Filter Units 10 9.0 18 18.0 36 36.0 75 Notes & Conditions 5 V nominal VDC 12 V nominal 24 V nominal 48 V nominal Internal Capacitor Input Surge 12 5 V nominal 25 12 V nominal VDC for 1 s 50 24 V models 48 V models 100 Output Maximum Units Notes & Conditions 30 VDC See Models and Ratings table Initial Set Accuracy ±1.5 % Output Voltage Balance ±2.0 % For dual output with balanced laods A No minimum load required From minimum to maximum input at full load Characteristic Minimum Output Voltage 3.3 Typical Minimum Load At full load Line Regulation ±0.2 % Load Regulation ±1.0 % From 0 to full load ±5.0 % On dual output models when one load is varied between 25% and 100% and other is fixed at 100% 5 % deviation Cross Regulation Transient Response Ripple & Noise 70 mV pk-pk Overload Protection 170 % Short Circuit Protection Recovery within 1% in less than 500 µs for a 25% load change. 20 MHz bandwidth. Measured using 0.47 µF ceramic capacitor. Continuous, with auto recovery Maximum Capacitive Load See Models and Ratings table Temperature Coefficient 0.02 %/ ˚C Maximum Units General Characteristic Minimum Typical Efficiency Isolation: Input to Output Isolation Resistance 84 % 1500/1800 100 Switching Frequency 100 60 s/1 s pF kHz At 500 VDC Ω Power Density W/in3 32.0 Mean Time Between Failure Weight See Models and Ratings table VDC 109 Isolation Capacitance Notes & Conditions 3.4 MHrs 0.008 (3.9) lb (g) MIL-HDBK-217F, +25 °C GB Environmental Characteristic Maximum Units Notes & Conditions Operating Temperature Minimum -40 Typical +95 °C See Derating Curve. Storage Temperature -50 +125 °C Case Temperature +95 °C Humidity 95 %RH Cooling Case Flammability Non-condensing Natural convection UL 94V-0 Rated Non conductive black plastic Lead-Free Reflow Solder Process IPC/JEDEC J-STD-020D.1 EMC: Emissions Phenomenon Standard Test Level Notes & Conditions Conducted EN55022 Class A See application note Radiated EN55022 Class A See application note www.xppower.com 2 IEU03 Series DC-DC Converter EMC: Immunity Test Level Criteria ESD EN61000-4-2 ±8 kV air discharge, ±6 kV contact A Radiated EN61000-4-3 10 V/m A EFT/Burst EN61000-4-4 ±2 kV A With external input capacitor, suggested part is CHEMI-CON KY 220µF/100V Surge EN61000-4-5 ±1 kV A With external input capacitor, suggested part is CHEMI-CON KY 220µF/100V Conducted EN61000-4-6 3 V rms A Magnetic Fields EN61000-4-8 3 A/m A Phenomenon Standard Notes & Conditions Safety Approvals Safety Agency Safety Standard Notes & Conditions CB Report IEC60950-1 Information Technology UL UL/cUL60950-1 Information Technology Mechanical Details 0.30 (7.62) 0.13 (3.19) 7 0.55 (14.0) Bottom View 0.30 (7.62) 4 0.31 (8.0) 1 0.01 (0.25) Pin Connections Pin 1 4 5 6 7 5 6 ø 0.02 (0.50) 0.10 (2.54) 2x0.10 (2x2.54) 0 55 (14 0) 0.12 (3.1) Single -Vin +Vin +Vout No Pin -Vout Dual -Vin +Vin +Vout Common -Vout 0.13 (3.19) Notes 3. Tolerance: X.XX±0.01 (X.X±0.25) X.XXX±0.005 (X.XX±0.13) 4. Pin Tolerance: ±0.002 (±0.05) 1. All dimensions are in inches (mm) 2. Weight: 0.008 lbs (3.9 g) approx. Application Notes Derating Curve EMI Filter L1 +Vin 100 Output Power (%) C1 -Vin 0 -40 70 Ambient Temperature (°C) 3 95 Model IEU0205 IEU0212 IEU0224 IEU0248 C1 22 µF/16 V 22 µF/25 V 10 µF/50 V 3.3 µF/100 V L1 3.3 µH 18.0 µH 39.0 µH 68.0 µH C1 = 5, 12 & 24 V: 1206 X5R MLCC, 48 V: 1206 X7S MLCC, L1 = SCD0504T series www.xppower.com 26 May 16