. VER : B_2 update : 2015.09.04 LED Power APF150 SERIES 150 Watts KEY FEATURES Fully Isolated Plastic Case with IP67 Level Universal Input: 90-305 VAC or 120-430 VDC Bulit-in Active PFC Function Free Air Convection High Reliability Isolation Class II LED Power Application 3-Year Product Warranty ELECTRICAL SPECIFICATIONS All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. Model No. APF150-12S Max Output Wattage (W) Voltage 150W Input Output Protection Isolation Environment Physical Safety APF150-36S APF150-48S APF150-54S 90-305 VAC or 120-430 VDC Frequency (Hz) 47-63 Hz Current (Full load) 2 A max. (115 VAC) / 1 A max. (230 VAC) / 0.9 A max. (277 VAC) Inrush Current (<2ms) 40 A max. (115 VAC) / 60 A max. (230 VAC) Leakage Current <0.75 mA max. Power Factor PF>0.97 (115 VAC) / PF>0.95 (230 VAC) / PF>0.9 (277 VAC) at Full Load Voltage (V.DC.) 12V 24V 36V 48V 54V Constant Current Range (V.DC.) 6 ~ 12V 12 ~ 24V 18 ~ 36V 24 ~ 48V 27 ~ 54V Voltage Accuracy ±2% Current (Convection) (mA) max 12500 6250 4166 3125 2777 Current ADJ Range (mA) 1250 ~ 12500 625 ~ 6250 416 ~ 4166 312 ~ 3125 377 ~ 2777 Line Regulation ±1% Load Regulation ±1% Maximum Capacitive Load 100,000 uF 50,000 uF 33,000 uF 6,000 uF 6,000 uF Ripple & Noise (max.) 100mVp-p 100mVp-p 100mVp-p 200mVp-p 200mVp-p Efficiency (typ.) 90.5% 92.5% 93.5% 92.5% 92.5% Hold-up Time 25 ms min. Over Power Protection Auto recovery Over Voltage Protection Auto recovery Overt Temperature Protection Auto recovery Short Circuit Protection Auto recovery Input-Output (V.AC) 3750V Input-FG (V.AC) 1880V Output-FG .(V.AC) 500V Operating Temperature -30°C…+60°C (with derating) Storage Temperature -40°C…+85°C Temperature Coefficient ±0.02%/°C ( 0~50°C ) Humidity 95% RH MTBF >75,000 h @ 25°C (MIL-HDBK-217F) Vibration 10~500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes. Dimension (L x W x H) 5.67 x 2.76 x 1.48 Inches Weight 660 g ±15% Cooling Method Free air convection Agency Approvals EN61347-1:2008、 EN61347-2-13:2006 EMI EN 55015 (Conducted & Radiated Emission) EMC APF150-24S EMS (Noise Immunity) EN 61547 Surge 2KV L-N http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 ( 144.0 x 70.0 x 37.5 mm ) Tolerance 2mm -1- . VER : B_2 update : 2015.09.04 LED Power APF150 SERIES 150 Watts NOTE 1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor. 2. It's recommended to add Varistor 14S561K at L / N input side in parallel. MECHANICAL DIMENSION ( Top View ) DERATING BLOCK DIAGRAM http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- . VER : B_2 update : 2015.09.04 LED Power APF150 SERIES 150 Watts DIMMING OPERATION Output constant current level can be adjusted through output cable by connecting a 3~10Vdc or 10V PWM signal between DIM+ and DIMI. 3~10V dimming function for output current adjustment (typ.) 110.0% 100.0% 90.0% 80.0% 70.0% Io (%) 60.0% 50.0% 40.0% 30.0% 20.0% 10.0% 0.0% 3V II. 4V 5V 6V 7V DIM (V) 8V 9V 10V 10V PWM signal for output current adjustment (typ.) : Frequency range:100Hz~3KHz 110.0% 100.0% 90.0% 80.0% 70.0% Io 60.0% (%) 50.0% 40.0% 30.0% 20.0% 10.0% 0.0% 30% 40% 50% 60% 70% 80% 90% 100% DIM(PWM) http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -3-