PerkinElmer MVS-4000 Machine vision strobe Datasheet

Imaging
D A T A S H E E T
Lighting
Telecom
Machine Vision Illumination Systems
MVS-4000
Machine Vision Strobe
Description
Features
The PerkinElmer MVS 4000 Mini Strobe
produces high intensity, short duration
light pulses for industrial vision applications. Operated in conjunction with a
CCD/CID solid state video camera, this
unit front-lights or back-lights objects,
freezes motion, and eliminates blur, thus
enhancing image quality.
• Flash Rates to 50 Hz
• 6 Microsecond Flash Duration
• Small/Light Weight
• Simple Installation and Operation
The MVS 4000 operates from an input
voltage of 12 VDC. The trigger input circuit is optically isolated, requiring a 5 volt
pulse to flash. The metal enclosure contains a printed circuit module, a 0.75 inch
arc quartz flashlamp, and reflector. Inputs
are made via a 9-pin connector located on
the rear of the strobe.
.
www.perkinelmer.com/opto
MVS-4000 Mini Strobe
Optical Specifications
300 to 1100+ nm
Spectral bandwidth (1)
50 Hz maximum
Flash rate
>108 flashes
Flashlamp life (3)
Flash duration (2)
6 microseconds
Flash to flash variation
< 5%
Illumination Characteristics
Area Illuminated
6 in. x 8 in.
12 in. x 16 in.
20 in. x 23 in.
36 in. x 48 in.
Distance
6 inches
1 foot
2 feet
3 feet
Note 1:
Note 2:
Note 3:
Note 4:
Photometric
19 lux-sec
5.7 lux-sec
1.5 lux-sec
0.6 lux-sec
Radiometric
15 x 10-6 J/cm2
4.5 x 10-6 J/cm2
1.2 x 10-6 J/cm2
0.5 x 10-6 J/cm2
Spectral bandwidth may be extended into the ultraviolet by using other flashlamp envelope and enclosure window materials.
Measured at 1/3 of peak value.
Prior to light output decreasing to 70% of the initial value.
Lux-sec - Lumen sec/m2
Physical Specifications
Size
Weight
Mounting
Inches (millimeters) 5.20 (132) L x 3.06 (78) W x 2.00 (51) H
0.75 lbs (0.34 kg)
1/4-20 threaded socket in base
Provision for internal optical filter included
Electrical Specifications
Input voltage
Input current
Flashlamp voltage
Discharge capacitor
Discharge energy
Discharge power
Tirgger input: (1)
Trigger
Pulse duration
11-15 VDC
1.10 amps maximum
600 volts ± 3%
1.0 microfarad ± 10%
0.18 Joules (± 10%)
10 watts maximum
+5 volt pulse into opto-isolator with 150 ohm nominal series resistor
10 to 100 microseconds
Input connector
Note 1:
9 pin “D” subminiature; mating connector providec
Delay between flash command and light output is 8 microseconds typical
Mechanical Specifications
1.49 2.00
(38) (51)
1.90 (48)
5.20 (132)
BACK VIEW
J19-PIN
CONNECTOR
3.89 (99)
3.06 (78)
1.53
(39)
1/4-20 FOR MOUNTING
BOTTOM VIEW
DIMENSIONS ARE IN INCHES (MILLIMETERS)
For more information e-mail us at [email protected] or visit our web site at www.perkinelmer.com/opto.
All values are nominal; specifications subject to change without notice.
USA:
PerkinElmer Optoelectronics
35 Congress Street
Salem, MA 01970
Toll Free: (800) 950-3441 (USA)
Phone: (978) 745-3200
Fax: (978) 745-0894
© 2001 PerkinElmer inc. All rights reserved.
Europe:
PerkinElmer Optoelectronics
Wenzel-Jaksch-Str. 31, D-65199
Weisbaden, Germany
Phone: +49 (0) 611-492-437
Fax: +49 (0)611-492-159
Asia:
PerkinElmer Optoelectronics
47 Ayer Rajah Crescent #06-12
Singapore 139947
Phone: +65 775 2022
Fax: +65 775 1008
0601
www.perkinelmer.com/opto
.
Similar pages