Rhombus L-12256 Power line choke Datasheet

Power Line
Chokes
Applications
Power Amplifiers
Filters Power Supplies
SCR and Triac Controls
Speaker Crossover Networks
RFI Suppression
Drum Core
Style
Part
Number
L
DCR
+ 20% Nom.
( µH ) ( mΩ )
I
Max.
(A)
Lead
Size Pkg.
AWG Code
L-12200
L-12202
L-12203
L-12204
L-12205
L-12206
L-12207
2.0
4.0
8.0
18
22
30
40
5
10
12
13
16
21
32
16.4
10.3
8.2
8.2
6.5
5.2
4.0
14
16
17
17
18
19
20
1
1
1
1
1
1
1
L-12401
L-12402
L-12403
L-12406
L-12407
L-12408
L-12411
15
20
30
38
50
70
100
8
11
17
25
28
38
59
13.0
10.3
8.2
6.5
6.0
5.2
4.1
15
16
17
18
18
19
20
2
2
2
2
2
2
2
L-12220
L-12221
L-12222
L-12223
L-12224
L-12225
L-12226
L-12227
5.0
20
30
50
80
120
180
200
8
13
19
25
42
53
72
105
16.0
12.9
8.5
6.8
5.4
5.0
4.3
4.1
15
16
17
18
19
19
20
20
3
3
3
3
3
3
3
3
Flammability: Materials used in the
production of these units are UL94-VO
and meet requirements of IEC 695-2-2
needle flame test.
Specifications subject to change without notice.
Rhombus
Industries Inc.
Pre-Tinned Leads
Center hole for mechanical mounting
Coils finished with Polyolefin Shrink Tube
Test Frequency 1 kHz
D
C
B
.750"
TYP.
A
Pkg.
Code
1
2
3
( Dimensions in inches )
A
B
C
D
0.560
0.709
0.709
0.810
0.795
0.866
0.187
0.187
0.187
0.126
0.126
0.126
For other values & Custom Designs, contact factory.
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649-1595
Tel: (714) 898-0960 • Fax: (714) 896-0971
Power Line
Chokes Drum
Applications
Power Amplifiers
Filters Power Supplies
SCR and Triac Controls
Speaker Crossover Networks
RFI Suppression
Core Style
Part
Number
L
+ 20%
( µH )
DCR
Nom.
( mΩ )
I
Max.
(A)
L-12420
L-12421
L-12423
L-12425
L-12428
L-12430
L-12431
L-12433
5.0
10
15
25
50
70
100
150
4
5
9
16
33
48
58
92
16.4
13.0
10.3
8.2
5.2
4.1
4.1
3.2
Lead
Size Pkg.
AWG Code
14
15
16
17
19
20
20
21
Pre-Tinned Leads
Center hole for mechanical mounting
Coils finished with Polyolefin Shrink Tube
Test Frequency 1 kHz
4
4
4
4
4
4
4
4
D
C
B
.7 5 0
TYP.
L-12440
L-12441
L-12442
L-12443
L-12445
L-12446
L-12447
L-12450
L-12452
10
15
25
50
75
100
180
280
450
5
8
15
19
29
40
46
75
131
21.6
17.1
13.2
12.8
10.8
8.5
8.0
6.8
5.4
14
15
16
16
17
18
18
19
20
Flammability: Materials used in the
production of these units are UL94-VO
and meet requirements of IEC 695-2-2
needle flame test.
Specifications subject to change without notice.
Rhombus
Industries Inc.
5
5
5
5
5
5
5
5
5
A
Pkg.
Code
4
5
( Dimensions in inches )
A
B
C
D
0.866
0.866
0.570
0.728
0.267
0.267
0.147
0.147
For other values & Custom Designs, contact factory.
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649-1595
Tel: (714) 898-0960 • Fax: (714) 896-0971
Applications
Power Amplifiers
Filters Power Supplies
SCR and Triac Controls
Speaker Crossover Networks
RFI Suppression
Power Line
Chokes Drum
Core Style
Part
Number
L
DCR
+ 20% Nom.
( µH ) ( mΩ )
I
Max.
(A)
Lead
Size Pkg.
AWG Code
L-12470
L-12471
L-12472
L-12473
L-12474
L-12475
L-12478
L-12480
L-12481
18
30
50
80
120
200
300
450
680
5
13
25
33
36
57
85
136
170
24.0
18.0
15.0
13.2
13.0
10.1
8.0
6.1
6.0
14
15
16
17
17
18
19
20
20
6
6
6
6
6
6
6
6
6
L-12235
L-12236
L-12237
L-12239
L-12242
L-12243
L-12245
L-12247
40
60
100
150
250
380
580
880
13
19
28
38
73
86
120
200
24.5
18.0
16.0
13.5
11.0
8.5
6.0
5.4
14
15
15
16
18
18
20
20
7
7
7
7
7
7
7
7
L-12490
L-12492
L-12493
L-12495
L-12497
L-12500
L-12503
45
70
120
185
280
450
700
12
18
35
50
78
130
198
25.0
18.8
13.9
12.0
9.5
7.5
4.1
14
15
16
17
18
19
20
8
8
8
8
8
8
8
Flammability: Materials used in the
production of these units are UL94-VO
and meet requirements of IEC 695-2-2
needle flame test.
Specifications subject to change without notice.
Rhombus
Industries Inc.
Pre-Tinned Leads
Center hole for mechanical mounting
Coils finished with Polyolefin Shrink Tube
Test Frequency 1 kHz
D
C
B
.750"
TYP.
A
Pkg.
Code
6
7
8
( Dimensions in inches )
A
B
C
D
0.949
0.955
1.100
0.795
0.975
0.805
0.187
0.187
0.237
0.126
0.126
0.175
For other values & Custom Designs, contact factory.
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649-1595
Tel: (714) 898-0960 • Fax: (714) 896-0971
Power Line
Chokes Drum
Applications
Power Amplifiers
Filters Power Supplies
SCR and Triac Controls
Speaker Crossover Networks
RFI Suppression
Core Style
Part
Number
L
+ 20%
( µH )
DCR
Nom.
( mΩ )
I
Max.
(A)
Lead
Size Pkg.
AWG Code
L-12530
L-12531
L-12534
L-12536
L-12538
L-12540
L-12543
L-12545
80
100
180
300
450
700
1300
2000
17
27
40
78
100
150
260
350
19.3
16.0
12.5
10.0
8.0
6.4
5.0
4.5
14
15
16
17
18
19
20
20
9
9
9
9
9
9
9
9
L-12254
L-12256
L-12257
L-12259
L-12262
L-12264
L-12266
L-12267
100
200
300
450
700
1000
1500
2000
22
38
56
70
130
166
250
340
12.0
10.0
8.5
8.5
5.5
5.5
4.3
3.4
14
15
16
16
18
18
20
20
10
10
10
10
10
10
10
10
L-12560
L-12561
L-12563
L-12564
L-12566
L-12567
L-12569
L-12571
L-12573
150
400
500
1000
1500
2000
3000
4700
7000
16
43
61
109
141
181
300
470
680
20.5
11.9
10.6
7.6
6.2
5.8
4.5
3.5
3.0
12
14
15
16
16
17
18
19
20
11
11
11
11
11
11
11
11
11
Pre-Tinned Leads
Center hole for mechanical mounting
Coils finished with Polyolefin Shrink Tube
Test Frequency 1 kHz
D
C
B
Flammability: Materials used in the
production of these units are UL94-VO
and meet requirements of IEC 695-2-2
needle flame test.
Specifications subject to change without notice.
Rhombus
Industries Inc.
.750"
TYP.
A
Pkg.
Code
9
10
11
( Dimensions in inches )
A
B
C
D
1.100
1.390
1.390
1.010
1.010
1.380
0.237
0.315
0.315
0.175
0.190
0.190
For other values & Custom Designs, contact factory.
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649-1595
Tel: (714) 898-0960 • Fax: (714) 896-0971
Power Line
Chokes Drum
Applications
Power Amplifiers
Filters Power Supplies
SCR and Triac Controls
Speaker Crossover Networks
RFI Suppression
Core Style
Part
Number
L
+ 20%
( µH )
DCR
Nom.
( mΩ )
I
Max.
(A)
Lead
Size Pkg.
AWG Code
L-12590
L-12591
L-12592
L-12593
L-12595
L-12597
L-12598
L-12599
L-12601
L-12603
L-12605
L-12606
200
300
450
700
1000
1700
2000
2600
3800
7900
10000
15000
19
25
44
59
97
148
170
220
340
650
920
960
19.2
17.8
15.0
11.7
9.4
7.6
6.8
6.0
5.0
3.4
3.0
2.9
11
12
14
14
15
16
16
17
18
19
20
20
12
12
12
12
12
12
12
12
12
12
12
12
L-12630
L-12632
L-12634
L-12636
L-12637
L-12639
L-12641
L-12643
L-12645
L-12648
200
380
750
1000
1600
2500
4000
6500
12000
18000
15
30
53
79
134
200
320
500
900
1400
28.8
21.4
15.6
13.2
10.5
7.8
6.5
5.2
3.8
3.6
10
12
13
14
15
16
17
18
19
20
13
13
13
13
13
13
13
13
13
13
Flammability: Materials used in the
production of these units are UL94-VO
and meet requirements of IEC 695-2-2
needle flame test.
Specifications subject to change without notice.
Rhombus
Industries Inc.
Pre-Tinned Leads
Center hole for mechanical mounting
Coils finished with Polyolefin Shrink Tube
Test Frequency 1 kHz
D
C
B
.750"
TYP.
A
Pkg.
Code
12
13
( Dimensions in inches )
A
B
C
D
1.770
2.200
1.380
1.380
0.360
0.380
0.270
0.290
For other values & Custom Designs, contact factory.
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649-1595
Tel: (714) 898-0960 • Fax: (714) 896-0971