CHENDA MBRF30150CT 150 to 200 volts forward current - 30.0 ampere Datasheet

MBRF301500CT THRU MBRF30200CT
SCHOTTKY BARRIER RECTIFIER
Reverse Voltage - 150 to 200 Volts
FEATURES
ITO-220AB
4.5± 0.2
10.2± 0.2
The plastic package carries Underwriters Laboratory
Flammability Classification 94V-0
Construction utilizes void-free
molded plastic technique
Low reverse leakage
High forward surge current capability
High temperature soldering guaranteed:
250 C,0.25”(6.35mm) from case for 10 seconds
4.0± 0.3
φ 3 .2± 0.2
φ 3 .3± 0.1
16.5± 0.3
PIN
2 3
8.2± 0.2
3.1+0.2
-0.1
15.0± 0.5
13.5± 0.5
1
Forward Current - 30.0 Amperes
2.6± 0.2
MECHANICAL DATA
1.4± 0.1
0.6± 0.1
Case: ITO-220AB molded plastic body
Terminals: Leads solderable per MIL-STD-750,
Method 2026
Polarity: As marked
Mounting Position: Any
Weight:0.060 ounce, 1.67 grams
0.6± 0.1
2.6± 0.15
PIN 1
PIN 2
PIN 3
CASE
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 C ambient temperature unless otherwise specified.
Single phase half-wave 60Hz,resistive or inductive load,for capacitive load current derate by 20%.
MDD Catalog Number
SYMBOLS
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Maximum average forward rectified current
(see fig.1)
Peak forward surge current
8.3ms single half sine-wave superimposed on
rated load (JEDEC Method)
Maximum instantaneous forward voltage at 15.0A
Maximum DC reverse current
TA=25 C
at rated DC blocking voltage
TA=100 C
VRRM
VRMS
VDC
Maximum thermal resistance(NOTE 1)
Operating junction temperature range
Storage temperature range
RθJC
TJ
TSTG
Note: 1.Thermal resistance from junction to case
MBRF30200CT
MBRF30150CT
200
140
200
150
135
150
UNITS
VOLTS
VOLTS
VOLTS
I(AV)
30.0
Amps
IFSM
300.0
Amps
VF
0.95
Volts
IR
0.2
50.0
mA
1.5
-55 to +150
-55 to +150
C/W
C
C
RATINGS AND CHARACTERISTIC CURVES MBRF30150CT THRU MBRF30200CT
FIG.1 TYPICAL FORWARD CHARACTERISTICS
FIG.2 FORWARD DERATING CURVE
30
Average Forward Rectified
Current, (A)
Instantaneous Forward Current, (A)
100
10
1.0
25
20
15
10
0
0.7
0.8 0.9 1.0
1.1
1.2 1.3
1.4
0
1.5
Instantaneous Forward Voltage, ( V )
FIG.3 TYPICAL REVERSE CHARACTERISTICS
50
75
100
125
150
Case Temperature, ( °C )
FIG.4 PEAK FORWARD SURGE CURRENT
1000
300
Peak Forward Surge Current,
(A)
Instantaneous Reverse Leakage
µ A)
Current, (μ
m
μ
25
100
10
TA=100°C
1.0
TA=25°C
0.1
240
180
120
60
0
0.01
0
20
40
60
80
100
120 140
Percent Of Rated Peak Reverse Voltage, %
1
10
Number Of Cycles At 60Hz
The cruve graph is for reference only, can't be the basis for judgment(曲线图仅供参考)!