Kompaktlüfter__2011__EN__Final__17_01_2011_:Vorlage 14:26 Seite 50 DC axial fans 440 m3/h max. 18.01.2011 Series 4100 N High Performance 119 x 119 x 38 mm -20...+65 65 000 / 37 500 132 500 2 /2 6 800 -20...+65 62 500 / 35 000 125 000 3 /2 6,8 12,4 5 000 -20...+65 70 000 / 52 500 147 500 1 /2 65 7,2 19,5 6 000 -20...+65 65 000 / 37 500 132 500 2 /2 67 7,4 30,0 6 800 -20...+65 62 500 / 35 000 125 000 3 /2 16...30 70 7,6 45,0 7 500 -20...+65 62 500 / 35 000 125 000 4 /2 24 16...30 73 8,1 65,0 8 400 -20...+65 60 000 / 32 500 120 000 5 /2 152,9 48 36...60 60 6,8 12,0 5 000 -20...+65 70 000 / 52 500 147 500 1 /2 182,4 48 36...60 65 7,2 20,0 6 000 -20...+65 65 000 / 37 500 132 500 2 /2 355 208,9 48 36...60 67 7,4 28,0 6 800 -20...+65 62 500 / 35 000 125 000 3 /2 390 229,5 48 36...60 70 7,6 45,0 7 500 -20...+65 62 500 / 35 000 125 000 4 /2 440 259,0 48 36...60 73 8,1 62,0 8 400 -20...+65 60 000 / 32 500 120 000 5 /2 A HP 152,9 12 9...15 60 4112 NH3 310 182,4 12 9...15 4112 NH4 355 208,9 12 9...14 4114 NHH 260 152,9 24 4114 NH3 310 182,4 4114 NH4 355 208,9 4114 NH5 390 4114 NH6 13,3 65 7,2 67 7,4 16...30 60 24 16...30 24 16...30 229,5 24 440 259,0 4118 NHH 260 4118 NH3 310 4118 NH4 4118 NH5 4118 NH6 [in H2O] Pa 6,8 600 2,0 1 ,6 200 0,8 100 0,4 Pa [in H2O] 4 1,2 400 300 1,2 5 500 3 0 50 100 1,0 100 150 200 200 300 250 400 CFM m³/h 0,4 0,8 100 50 0,2 150 0,6 2 200 0 1 50 100 50 100 150 200 200 300 NG 250 CFM 400 m³/h T I PWM Specials 6 000 32,0 260 Watts / Curve 21,6 4112 NHH dB(A) Bel(A) (40 °C) see P. 15 1 VDC 250 Life expectancy L10∆ 147 500 VDC 300 Service life L10 (Tmax) ebm-papst Standard 70 000 / 55 000 CFM 350 Service life L10 (40 °C) ebm-papst Standard Temperature range -20...+65 m3/h Power input 5 000 Type Nominal data Sound power level Hours Voltage range Hours Nominal voltage °C Air flow RPM Air flow Nominal speed Sintec sleeve bearings Ball bearings Sound pressure level Highlights: – Very rigid compression curve for high air flow at high back pressure. – Low operating noise level at high back pressure. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4 x 8 (Torx). – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, UL1007, TR 64, bared and tin-plated – Air intake over struts. Direction of rotation clockwise, seen on rotor. – Mass: 390 g. P. 110 Speed signal /2 VDC mA VDC mA 2 £ 30 0 30 2 2 31 400 F £ 0.4 1 £ 30 0 30 2 2 32 400 £ 0.4 1 £ 30 0 30 2 2 33 420 J £ 0.4 2 £ 15 0 15 4 2 34 500 F £ 0.4 1 £ 30 0 30 2 2 35 600 F £ 0.4 1 £ 30 0 30 2 2 36 620 £ 0.4 2 £ 30 0 30 4 2 37 630 U £ 0.4 2 £ 30 0 30 4 2 38 600 N £ 0.4 2 £ 28 0 28 4 2 39 600 J £ 0.4 2 £ 30 0 30 4 2 41 700 F £ 0.4 2 £ 30 0 30 4 2 42 8450 £ 0.4 2 £ 28 0 28 4 2 43 8400 N £ 0.4 2 £ 28 0 28 4 2 44 8400 N VARIOFAN £ 0.4 2 £ 30 0 30 4 2 45 8300 £ 0.4 2 £ 30 0 30 4 2 46 8200 J £ 0.4 2 £ 30 0 30 4 2 47 3400 N £ 0.4 2 £ 28 0 28 4 2 48 3400 N VARIOFAN £ 0.4 2 £ 30 0 30 4 2 49 3300 N £ 0.4 2 £ 30 0 30 4 2 50 3212 J / 3214 J £ 0.4 2 £ 30 0 30 4 2 51 3218 J £ 0.4 2 £ 60 0 60 4 2 51 3250 J £ 0.4 2 £ 60 0 60 4 3 52 4412 F / 4414 F £ 0.4 2 £ 30 0 30 4 2 53 4418 F £ 0.4 2 £ 60 0 60 4 2 53 4400 FN £ 0.4 2 £ 30 0 30 4 2 55 4312 / 4314 £ 0.4 2 £ 30 0 30 4 2 56 4318 2016-01 Fan description Basic type Condition: Isource mA £ 0.4 Page £ 0.4 2 £ 60 0 60 4 2 56 4312 / 4314 VARIOFAN £ 0.4 2 £ 30 0 30 4 2 57 4318 VARIOFAN £ 0.4 2 £ 60 0 60 4 2 57 4400 £ 0.4 2 £ 30 0 30 4 2 58/59 4100 N £ 0.4 2 £ 30 0 30 4 2 60 4100 NHH...NH6 £ 0.4 2 £ 60 0 60 10 2 61 4100 NH7...NH8 £ 0.4 2 £ 60 0 60 20 3 62 DV 4100 £ 0.4 2 £ 30 0 30 4 2 63 5200 N £ 0.4 2 £ 30 0 30 4 2 64 DV 5200 £ 0.4 2 £ 30 0 30 4 2 65 Subject to change 168 Pulses per revolution Speed signal US High VDC Signal data Tach operating voltage UBS max. Condition: Isink Type 250 Electrical hookup All voltages measured to ground. External load resistor Ra / US / UBS required. Admissible sink current Isink max. Speed-proportional, square-wave signal for external monitoring of the fan motor speed 2, 3, or 6 pulses per revolution Open-collector signal output Extremely wide operating voltage range Easy adaptation to user interface Connection via separate cable The sensor signal also serves as a major comparison variable for setting and maintaining the setpoint speed for interactive or controlled cooling with one or more interconnected fans. Speed signal US Low – – – – – – – Information Tach operating voltage UBS max. Admissible sink current Isink max. VDC mA VDC mA 2 £ 15 0 5 20 2 66 5114 N / 5118 N £ 0.4 2 £ 60 0 60 20 2 66 5300 £ 0.4 2 £ 60 0 60 4 2 67 5300 TD £ 0.4 2 £ 60 0 60 20 6 68 7112 N / 7118 N £ 0.4 2 £ 60 0 60 20 2 69 7114 N £ 0.4 2 £ 30 0 30 20 2 69 7200 N £ 0.4 2 £ 15 0 15 20 2 70 6400 £ 0.4 2 £ 60 0 60 20 2 71 6300 TD £ 0.4 2 £ 60 0 60 20 6 75 6300 N £ 0.4 2 £ 60 0 60 20 6 76 6300 NTD £ 0.4 2 £ 60 0 60 20 6 77 6300 £ 0.4 2 £ 60 0 60 20 2 78 DV 6300 TD £ 0.4 2 £ 60 0 60 20 6 80 2200 FTD £ 0.4 2 £ 60 0 60 20 6 81 RL 48 £ 0.4 2 £ 30 0 30 4 2 97 RL 65 £ 0.4 2 £ 30 0 30 4 2 98 RL 90 N £ 0.4 2 £ 30 0 30 4 2 99 RLF 100 £ 0.4 2 £ 30 0 30 4 2 100 RG 90 N £ 0.4 2 £ 30 0 30 4 2 101 RG 125 N £ 0.4 2 £ 30 0 30 4 2 102 RG 140 N £ 0.4 3 £ 60 0 60 4 2 103 RG 160 N £ 0.4 2 £ 30 0 30 20 2 104 RG 160 NTD £ 0.4 2 £ 60 0 60 20 6 105 RG 190 TD £ 0.4 2 £ 60 0 60 20 6 106 RG 220 TD £ 0.4 2 £ 60 0 60 20 6 107 RG 225 TD £ 0.4 2 £ 60 0 60 20 6 108 RET 97 TD £ 0.4 2 £ 60 0 60 20 6 109 REF 100 £ 0.4 2 £ 30 0 30 4 2 110 RER 120 TD £ 0.4 2 £ 60 0 60 20 6 112 RER 133 TD £ 0.4 2 £ 60 0 60 20 6 117 RER 160 NTD £ 0.4 2 £ 60 0 60 20 6 119 REF 175 TD £ 0.4 2 £ 60 0 60 20 6 120 RER 175 TD £ 0.4 2 £ 60 0 60 20 6 121 RER 190 TD £ 0.4 2 £ 60 0 60 20 6 122 RER 220 TD £ 0.4 2 £ 60 0 60 20 6 128 RER 225 TD £ 0.4 2 £ 60 0 60 20 6 129 Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials Page Note: Fans that come with these fan specials could have variations with respect to the temperature range, voltage range, and power consumption compared to standard fans without specials. 169 2016-01 Subject to change DC centrifugal fans Condition: Isource mA £ 0.4 Representatives Speed signal US High VDC Fan description Basic type Condition: Isink Type 5112 N Signal data Pulses per revolution Speed signal US Low DC axial fans Available on request: – Electrically isolated speed signal circuit – Varying voltage potentials for power and logic circuit