Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
SPECIFICATION
MODEL
OUTPUT
RQ-50B
RQ-50D
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
DC VOLTAGE
5V
12V
-5V
-12V
5V
15V
-5V
-15V
5V
12V
24V
-12V
RATED CURRENT
5A
1A
0.5A
0.5A
5A
1A
0.5A
0.5A
3A
0.9A
0.9A
0.5A
CURRENT RANGE
0.5 ~ 6A
0.2 ~ 1.5A 0 ~ 1A
0 ~ 1A
0.5 ~ 6A
0.2 ~ 1.5A 0 ~ 1A
0 ~ 1A
0.5 ~ 6A
0.2 ~ 1.5A 0.1 ~ 1A
RATED POWER
45.5W
50W
CH4
0 ~1A
53.4W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 100mVp-p 80mVp-p 80mVp-p 120mVp-p 100mVp-p 80mVp-p 80mVp-p 120mVp-p 180mVp-p 80mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
2.0%
6.0%
2.0%
2.0%
CH1: 4.75 ~ 5.5V
2.0%
6.0%
+7,-5%
2.0%
Note.4
0.5%
1.5%
0.5%
0.5%
0.5%
1.5%
0.5%
0.5%
0.5%
1.5%
2.0%
0.5%
LOAD REGULATION
Note.5
0.5%
3.0%
1.0%
1.0%
0.5%
3.0%
1.0%
1.0%
0.5%
3.0%
3.0%
1.0%
SETUP, RISE TIME
500ms, 20ms/230VAC
HOLD UP TIME (Typ.)
60ms/230VAC
VOLTAGE RANGE
88 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
74%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.3A/115VAC
0.8A/230VAC
COLD START 36A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
2.0%
2.0%
CH1: 4.75 ~ 5.5V
2.0%
6.0%
LINE REGULATION
VOLTAGE TOLERANCE Note.3
INPUT
RQ-50C
OUTPUT NUMBER
1200ms, 30ms/115VAC at full load
10ms/115VAC at full load
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
75%
79%
110 ~ 150% rated output power
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
(Note 6)
OTHERS
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF
162.9Khrs min. MIL-HDBK-217F (25
99*97*36mm (L*W*H)
0.41Kg; 45pcs/19.5Kg/0.9CUFT
DIMENSION
PACKING
NOTE
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:RQ-50-SPEC 2010-10-18
RQ-50
50W Quad Output Switching Power Supply
Mechanical Specification
Case No. 905B
51.5
3.5
2
8.25
Unit:mm
36
1
series
3
4
5.5
3
97
5
M
55.5
2-
7
6
7
8
20.5
55
3.5
4.5
89
99
6.5
87
3
74
18
Pin No.
Assignment
1
AC/L
2
AC/N
3
FG
4
DC OUTPUT -V4
36
2-M
28
3.5
17.5
7
Terminal Pin No. Assignment
3.5
Block Diagram
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
Assignment
DC OUTPUT V3
DC OUTPUT +V2
DC OUTPUT COM
DC OUTPUT +V1
RECTIFIERS
&
FILTER
+V4
RECTIFIERS
&
FILTER
+V3
RECTIFIERS
&
FILTER
+V2
RECTIFIERS
&
FILTER
+V1
COM
fosc : 60KHz
DETECTION
CIRCUIT
FG
O.L.P.
Pin No.
5
6
7
8
CONTROL
O.V.P.
Derating Curve
Output Derating VS Input Voltage
Ta=25
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-25
-25
0
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (VERTICAL)
60
50
40
88
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:RQ-50-SPEC 2010-10-18