RQ-50 50W Quad Output Switching Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty SPECIFICATION MODEL OUTPUT RQ-50B RQ-50D CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V -12V 5V 15V -5V -15V 5V 12V 24V -12V RATED CURRENT 5A 1A 0.5A 0.5A 5A 1A 0.5A 0.5A 3A 0.9A 0.9A 0.5A CURRENT RANGE 0.5 ~ 6A 0.2 ~ 1.5A 0 ~ 1A 0 ~ 1A 0.5 ~ 6A 0.2 ~ 1.5A 0 ~ 1A 0 ~ 1A 0.5 ~ 6A 0.2 ~ 1.5A 0.1 ~ 1A RATED POWER 45.5W 50W CH4 0 ~1A 53.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 100mVp-p 80mVp-p 80mVp-p 120mVp-p 100mVp-p 80mVp-p 80mVp-p 120mVp-p 180mVp-p 80mVp-p VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V 2.0% 6.0% 2.0% 2.0% CH1: 4.75 ~ 5.5V 2.0% 6.0% +7,-5% 2.0% Note.4 0.5% 1.5% 0.5% 0.5% 0.5% 1.5% 0.5% 0.5% 0.5% 1.5% 2.0% 0.5% LOAD REGULATION Note.5 0.5% 3.0% 1.0% 1.0% 0.5% 3.0% 1.0% 1.0% 0.5% 3.0% 3.0% 1.0% SETUP, RISE TIME 500ms, 20ms/230VAC HOLD UP TIME (Typ.) 60ms/230VAC VOLTAGE RANGE 88 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 74% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.3A/115VAC 0.8A/230VAC COLD START 36A/230VAC LEAKAGE CURRENT <2mA / 240VAC 2.0% 2.0% CH1: 4.75 ~ 5.5V 2.0% 6.0% LINE REGULATION VOLTAGE TOLERANCE Note.3 INPUT RQ-50C OUTPUT NUMBER 1200ms, 30ms/115VAC at full load 10ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 75% 79% 110 ~ 150% rated output power OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B (Note 6) OTHERS HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A MTBF 162.9Khrs min. MIL-HDBK-217F (25 99*97*36mm (L*W*H) 0.41Kg; 45pcs/19.5Kg/0.9CUFT DIMENSION PACKING NOTE ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:RQ-50-SPEC 2010-10-18 RQ-50 50W Quad Output Switching Power Supply Mechanical Specification Case No. 905B 51.5 3.5 2 8.25 Unit:mm 36 1 series 3 4 5.5 3 97 5 M 55.5 2- 7 6 7 8 20.5 55 3.5 4.5 89 99 6.5 87 3 74 18 Pin No. Assignment 1 AC/L 2 AC/N 3 FG 4 DC OUTPUT -V4 36 2-M 28 3.5 17.5 7 Terminal Pin No. Assignment 3.5 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING Assignment DC OUTPUT V3 DC OUTPUT +V2 DC OUTPUT COM DC OUTPUT +V1 RECTIFIERS & FILTER +V4 RECTIFIERS & FILTER +V3 RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM fosc : 60KHz DETECTION CIRCUIT FG O.L.P. Pin No. 5 6 7 8 CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -25 -25 0 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (VERTICAL) 60 50 40 88 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RQ-50-SPEC 2010-10-18