SICK C4P-EA04530A001000 Safety light curtain Datasheet

Online data sheet
C4P-SA04530A001000, C4PEA04530A001000
deTec4 Prime
SAFETY LIGHT CURTAINS
C4P-SA04530A001000, C4P-EA04530A001000 | deTec4 Prime
SAFETY LIGHT CURTAINS
A
B
C
D
E
F
Ordering information
System part
Type
Part no.
Sender
C4P-SA04530A001000
1215755
C4P-EA04530A001000
1215756
Receiver
Other models and accessories
www.sick.com/deTec4_Prime
Detailed technical data
Features
H
I
J
K
L
M
N
O
P
Q
R
S
T
System part
Sender/receiver pair with system plug and QuickFix bracket
Usage
As a standalone system and as last system in a cascade
Resolution
30 mm
Protective field height
450 mm
Scanning range
Minimum 0.15 m ... 24 m
Typical 0.15 m ... 30 m
Response time
10 ms 1)
No blind zones
✔
Synchronization
Optical synchronisation
1)
, without beam coding, no cascaded systems. Other response times see operating instructions.
Safety-related parameters
Type
Type 4 (IEC 61496)
Safety integrity level
SIL3 (IEC 61508)
SILCL3 (EN 62061)
Category
Category 4 (EN ISO 13849)
Performance level
PL e (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour)
Single device 9.6 x 10-9 (EN ISO 13849)
Cascade with one guest 1.9 x 10-8 (EN ISO 13849)
Cascade with two guest devices 2.9 x 10-8 (EN ISO 13849)
TM (mission time)
20 years (EN ISO 13849)
Safe state in the event of a fault
At least one OSSD is in the OFF state.
2
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-08-21 16:38:06
Subject to change without notice
C4P-SA04530A001000, C4P-EA04530A001000 | deTec4 Prime
SAFETY LIGHT CURTAINS
Functions
Functions
Delivery status
Restart interlock
✔
Deactivated
External device monitoring (EDM)
✔
Deactivated
Beam coding
✔
Uncoded
Automatic calibration of the protective field ✔
width
Interfaces
System connection
Connection type Male connector M12, 5-pin
Flexi-Loop-ready ✔
Sender/receiver communication (COM1) ✔ 1)
Permitted cable length Receiver power supply: 15 m 2)
All additional conductors at the system connection: 37.5 m
Configuration method
Cascade Automatic detection when starting the device
External device monitoring (EDM) Automatic detection when starting the device
Calibration of the protective field width Automatic detection when starting the device
Restart interlock Teach-in procedure when starting the device
Beam coding DIP switch
Reset to factory default DIP switch
Status display
LEDs
Fieldbus, industrial network
Integration via Flexi Soft safety controller CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 3)
1)
2)
3)
Optional: To indicate the status on both sides, the COM1 connections from the sender and receiver must be connected to each other in the control cabinet.
If no inductive OSSD loads (e.g., contactors) are in use, the power supply cable for the receiver of a single device (no cascade) can be up to 30 m in length.
For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Protection class
III (EN 50178) 1)
Supply voltage VS
24 V DC (19.2 V DC ... 28.8 V DC)
Ripple
≤ 10 % 2)
Power consumption typical
3.3 W (DC) / 1.31 W (DC) (depending on type)
Safety outputs (OSSD)
Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 3)
Switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS)
Switching voltage LOW ≤ 2 V DC
Switching current ≤ 500 mA
1)
2)
3)
SELV/PELV safety/protective extra-low voltage.
Within the limits of VS.
Applies to the voltage range between –30 V and +30 V.
2017-08-21 16:38:06 | Online data sheet

Subject
to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
3
C4P-SA04530A001000, C4P-EA04530A001000 | deTec4 Prime
SAFETY LIGHT CURTAINS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Mechanical data
Housing cross-section (incl. system connection)
34 mm x 41.1 mm
Housing material
Aluminum extruded profile
Front screen material
Polycarbonate, scratch-resistant coating
Ambient data
Enclosure rating
IP65 (EN 60529)
IP67 (EN 60529)
Ambient operating temperature
–30 °C ... +55 °C
Storage temperature
–30 °C ... +70 °C
Air humidity
15 % ... 95 %, Non-condensing
Vibration resistance
5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Shock resistance
10 g, 16 ms (EN 60068-2-29)
Other information
Wave length
850 nm
Integrated laser alignment aid
✔
Light source Laser diode
Laser class 1 (IEC 60825-1)
Type of light Visible red light
Wave length 650 nm
Classifications
ECl@ss 5.0
27272704
ECl@ss 5.1.4
27272704
ECl@ss 6.0
27272704
ECl@ss 6.2
27272704
ECl@ss 7.0
27272704
ECl@ss 8.0
27272704
ECl@ss 8.1
27272704
ECl@ss 9.0
27272704
ETIM 5.0
EC002549
ETIM 6.0
EC002549
UNSPSC 16.0901
46171620
4
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-08-21 16:38:06
Subject to change without notice
C4P-SA04530A001000, C4P-EA04530A001000 | deTec4 Prime
SAFETY LIGHT CURTAINS
Dimensional drawing (Dimensions in mm (inch))
30.7
21.8
(0.86)
30
(1.18)
13.8
(0.54)
56.8
(2.24)
(1.21)
29.5
5
(0.2)
14
(0.55)
L
(1.16)
34
30.7
(1.21)
41.1
(1.62)
56.8
(2.24)
21.8
(0.86)
56.8
(2.24)
13.8
(0.54)
4
(0.16)
(2.24)
56.8
(1.34)
L
2017-08-21 16:38:06 | Online data sheet

Subject
to change without notice
300
313
450
463
600
613
750
763
900
913
1,050
1,063
1,200
1,213
1,350
1,362
1,500
1,512
1,650
1,662
1,800
1,812
1,950
1,962
2,100
2112
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
5
C4P-SA04530A001000, C4P-EA04530A001000 | deTec4 Prime
SAFETY LIGHT CURTAINS
A
B
C
D
E
F
Connection diagram
deTec4 Prime safety light curtain to UE10-3OS safety relay
+24 V
r
2
+24 V
+24 V
2
3
n.c
RES
1
4
n.c.
EDM
4
5
In2
OSSD1
5
In1
OSSD2
6
n.c.
ADO
3
0V
0V
7
Com1
8
6
1
7
8
Com1
deTec4 Prime
H
I
J
K
L
M
N
O
P
Q
R
S
T
S1
s
B1 B3
2)
Y1 13 23 33 41
1)
UE10-3OS
B2 B4
Y2 14 24 34 42
H2
0V
E132908/00/2015-04-07
3) PELV
① Output circuits. These contacts must be incorporated into the control such that the dangerous state is brought to an end if the output circuit is
open. For categories 4 and 3, they must be incorporated on two channels (x, y paths). Single-channel incorporation into the control (z path) is only
possible with a single-channel control and taking the risk analysis into account.
② To indicate the status on both sides, the Com1 connections from the sender and receiver must be connected to each other in the control cabinet (optional).
③ SELV/PELV safety/protective extra-low voltage.
6
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-08-21 16:38:06
Subject to change without notice
C4P-SA04530A001000, C4P-EA04530A001000 | deTec4 Prime
SAFETY LIGHT CURTAINS
deTec4 Prime safety light curtain cascade to UE10-3OS safety relay
+24 V
s
1
2
3
4
5
6
7
8
r
RES
n.c.
+24 V
+24 V
n.c.
ADO
n.c.
OSSD1
In2
OSSD2
In1
EDM
0V
0V
Com1
Com1
1
2
3
5
6
4
7
8
3)
B1
B3
Y1
13
23
33
41
Y2
14
24
34
42
1)
2)
UE10-3OS
B2
B4
deTec4 Prime
0V
4) PELV
E132954/00/2015-04-07
① Output circuits. These contacts must be incorporated into the control such that the dangerous state is brought to an end if the output circuit is
open. For categories 4 and 3, they must be incorporated on two channels (x, y paths). Single-channel incorporation into the control (z path) is only
possible with a single-channel control and taking the risk analysis into account.
② Connection of the 5-pin extension connection of the host device to the 5-pin system connection of the guest device.
③ To indicate the status on both sides, the Com1 connections from the sender and receiver must be connected to each other in the control cabinet (optional).
④ SELV/PELV safety/protective extra-low voltage.
2017-08-21 16:38:06 | Online data sheet

Subject
to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
7
C4P-SA04530A001000, C4P-EA04530A001000 | deTec4 Prime
SAFETY LIGHT CURTAINS
deTec4 Prime safety light curtain with T-connector to UE48-2OS safety relay
+24 V
1
2
4
3
5
4
3
3
5
5
r
+24 V
+24 V
In2
OSSD1
In1
OSSD2
0V
0V
Com1
Com1
1)
x
y
k1 k2
x y
z
k1
5
4
3
2
4
1
2
2
s
1
1
A
B
C
D
E
F
k2
1
z
2
4
3
S1
S33 S11 S12 S31 A1 13 23 31
5
k1
UE48-2OS2D2
deTec4 Prime
S34 S35 S21 S22 A2 14 24 32
k2
H
I
J
K
L
M
N
O
P
Q
R
S
T
2)
K1
K2
0V
3) PELV
E132906/00/2015-04-07
① Output circuits. These contacts must be incorporated into the control such that the dangerous state is brought to an end if the output circuit is
open. For categories 4 and 3, they must be incorporated on two channels (x, y paths). Single-channel incorporation into the control (z path) is only
possible with a single-channel control and taking the risk analysis into account.
② External device monitoring is only static.
③ SELV/PELV safety/protective extra-low voltage.
Task
Connection of a deTec4 Prime safety light curtain to a UE48-2OS safety relay. Operating mode: with restart interlock and external
device monitoring (EDM). The T-piece establishes a connection between the sender and the receiver.
Mode of operation
When the protective field is clear, the OSSD1 and OSSD2 outputs carry voltage. The system can be switched on when K1 and K2
are in a fault-free de-energized position. The UE48-2OS is switched on by pressing S1 (pushbutton is pressed and released). The
outputs (contacts 13-14 and 23-24) switch the K1 and K2 contactors on. When the protective field is interrupted, the OSSD1 and
OSSD2 outputs switch the UE48-2OS off. Contactors K1 and K2 are switched off.
Fault analysis
Cross-circuits and short-circuits of the OSSD1 and OSSD2 outputs are recognized and lead to the locking state (lock-out). A malfunction with one of the K1 or K2 contactors is detected. The shut-down function is retained. In the event of manipulation (e.g.,
jamming) of the S1 pushbutton, the UE48-2OS will not re-enable the output current circuits.
Task
Connection of two deTec4 Prime safety light curtains to a UE10-3OS safety relay. Operating mode: without restart interlock, with external device monitoring (EDM). If required, the restart interlock is implemented via the machine controller.
Mode of operation
If the protective field is clear and the UE10-3OS is in a fault-free de-energized position, the system is enabled. Outputs OSSD1 and
OSSD2 carry voltage, the UE10-3OS is switched on. When the protective field is interrupted, the OSSD1 and OSSD2 outputs switch
the UE10-3OS off.
Fault analysis
Cross-circuits and short-circuits of the OSSDs are recognized and lead to the locking state (lock-out). The malfunction of the
UE10-3OS is detected. The shut-down function is retained.
Task
Connection of a deTec4 Prime safety light curtain to a UE10-3OS safety relay. Operating mode: with restart interlock, external device monitoring (EDM), and application diagnostic output.
Mode of operation
8
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-08-21 16:38:06
Subject to change without notice
C4P-SA04530A001000, C4P-EA04530A001000 | deTec4 Prime
SAFETY LIGHT CURTAINS
If the protective field is clear and the UE10-3OS is in a fault-free de-energized position, the field indicator and the H2 lamp flash.
The system can be switched on. The system is enabled by pressing S1 (pushbutton is pressed and released). Outputs OSSD1 and
OSSD2 carry voltage, the UE10-3OS is switched on. When the protective field is interrupted, the OSSD1 and OSSD2 outputs switch
the UE10-3OS off.
Fault analysis
Cross-circuits and short-circuits of the OSSDs are recognized and lead to the locking state (lock-out). The malfunction of the
UE10-3OS is detected. The shut-down function is retained. Manipulation (e.g., jamming) of the S1 pushbutton prevents the output
circuits from being enabled.
2017-08-21 16:38:06 | Online data sheet

Subject
to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
9
Online data sheet
SICK at a glance
SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely
and efficiently, protecting individuals from accidents and preventing damage to the environment.
We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in
Europe, Asia and North America, system solutions are tested and optimized in accordance with customer
specifications. All this makes us a reliable supplier and development partner.
Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity.
For us, that is “Sensor Intelligence.”
Worldwide presence:
Contacts and other locations – www.sick.com
SICK AG | Waldkirch | Germany | www.sick.com
Similar pages