Vitec MTWA26-S11 25w multi-plug wall mount for i.t. equipment Datasheet

MTWA26 SERIES
25W Multi-Plug Wall Mount for I.T. Equipment






1 Year Warranty
Wide Input Voltage 90 to 264 VAC, 47 to 63Hz
Interchangeable AC plug(USA, UK, Europe, Australia)
Output Voltage Available From 5VDC Thru 48VDC
Single Output
Class II Insulation (Double Insulation)
Energy Star 2.0, CEC V, and RoHS compliance
Approvals:
Single Output
Product Number
MTWA26-S02
MTWA26-S03
MTWA26-S04
MTWA26-S05
MTWA26-S06
MTWA26-S07
MTWA26-S08
MTWA26-S09
MTWA26-S10
MTWA26-S11
Output Voltage
5 ~ 6 VDC
6 ~ 8 VDC
8 ~ 11 VDC
11 ~ 13 VDC
13 ~ 16 VDC
16 ~ 21 VDC
21 ~ 27 VDC
27 ~ 33 VDC
33 ~ 40 VDC
40 ~ 48 VDC
Max. Output Current
3.30 ~ 2.75 A
3.33 ~ 2.50 A
2.75 ~ 2.00 A
2.27 ~ 1.92 A
1.92 ~ 1.56 A
1.56 ~ 1.19 A
1.19 ~ 0.92 A
0.92 ~ 0.75 A
0.75 ~ 0.62 A
0.62 ~ 0.52 A
Total Regulation
5%
5%
5%
5%
5%
5%
3%
3%
3%
2%
Maximum Output Power
16.5W
20W
22W
25W
25W
25W
25W
25W
25W
25W
The total regulation on S02~S06 required to use AWG#16× 2C/4FT output cable.
The total regulation on S07~S11 required to use AWG#18× 2C/4FT output cable.
The regulation and efficiency will be changed by modified output cable.
Electrical Characteristics
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Transient Response
Hold-Up Time
Start Up Time
Ripple & Noise (Peak to Peak)
Temperature Coefficient
No-load Power Consumption
Test Conditions
Operating Voltage
Vin=100 to 240VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25°C, Cool start, Vin=115VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
Vin=230VAC
Nil But, Output protected to short circuit conditions
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=230VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
All output
No load, Vin=240VAC
Min.
90
47
0
77
Typ.
25
50
82
0.5
3
Nil
Max.
264
63
25
0.4
0.25
50
100
85
1
5
4
8
2
0.5
-0.04
0.25
3
1
0.04
0.3
Unit
VAC
Hz
W
A
A
A
A
%
%
%
%
%
mS
mS
S
%
%/°C
W
Conditions
Parameter
Test Conditions
Operating Temperature
Storage Temperature
Relative Humidity
No-Condensing
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F
De-rate linearly from 100 % load at 40°C to 50 % load at 70°C
Min.
0
-40
5
0.1M
Typ.
40
Max.
70
85
95
Unit
°C
°C
%
Hrs
Min.
Unit
4242
50
B
B
VDC
MΩ
CLASS
CLASS
Approvals and Compliance
Parameter
Dielectric Withstanding Voltage for Primary to secondary
Isolation Resistance
EMI requirements for CISPR-22
EMI requirements for FCC PART-15
Test Conditions
Primary to secondary
Test Voltage= 500VDC
Vin=220VAC
Vin=110VAC
Mechanical and PIN out
Note:
1.
Dimensions are shown in mm.
2.
Weight: 200g approx.
3.
Optional output connector.
Similar pages