Microdc B1215XDP01 Isolated 1w single output dc/dc converter Datasheet

B-XDP01 Series
Isolated 1W Single Output DC/DC Converters
SELECTION GUIDE
FEATURES
◆
RoHS compliant
◆
I/O isolation voltage 1000VDC
◆
Operating Temperature: -40℃~﹢85℃
◆
High efficiency up to 81%
◆
Fully encapsulated toroidal magnetics
◆
◆
Internal SMD construction
3
Power density up to 0.85W/cm
◆
No electrolytic or tantalum capacitors
◆
5V,9V,12Vand 15V output
◆
No heatsink required
◆
UL 94V-0 package material
◆
No external components required
Industry standard pinout
◆
◆
Power sharing on output
◆
MTTF up to 3.4 million hours
Input
Voltage
(V)
Output
Voltage
(V)
Output
Current
(MA)
Input Current
(Rated Load)
(MA)
Efficiency
Order code
B0505XDP01
5
5
200
290
B0509XDP01
5
9
111
B0512XDP01
5
12
B0515XDP01
5
B1205XDP01
12
B1209XDP01
B1212XDP01
MTTF1
(%)
Isolation
Capacitance
(PF)
(KHRS)
69
28
1847
285
70
29
1548
83
260
77
33
981
15
67
253
79
40
667
5
200
121
69
36
1485
12
9
111
263
76
29
1358
12
12
83
110
76
58
869
B1215XDP01
12
15
67
110
76
56
613
B1505XDP01
15
5
200
93
69
27
2110
B1509XDP01
15
9
111
277
72
29
1850
B1512XDP01
15
12
83
85
77
58
1790
B1515XDP01
15
15
67
84
78
67
1560
B2405XDP01
24
5
200
60
70
61
1253
B2409XDP01
24
9
111
263
76
29
1120
B2412XDP01
24
12
83
53
78
98
784
B2415XDP01
24
15
67
52
80
122
566
Input Characteristics
Parameter
Voltage range
MODEL SELECTION
B①05②05③X④ D⑤P01⑥
Reflected ripple current
①Product Series
②Input Voltage
③Output Voltage
④Fixed Input
⑤DIP14 Package Style ⑥Rated Power 1W
APPLICATIONS
The B-XDP01 series of industrial
temperature range DC/DC converters are the
standard building blocks for on-board
distributed power systems.They are ideally
suited for providing single rail supplies on
primarily digital boards with the added benefit
of galvanic isolation to reduce switching noise.
Surface mount technology and advanced
packaging materials produce rugged reliable
performance over an extended temperature
range from -40°C to 85°C.
Conditions
Min
Typ.
Max.
Continuous operation,5V input types
4.5
5
5.5
Continuous operation,12V input types
10.8
12
13.2
Continuous operation,15V input types
13.5
15
16.5
Continuous operation,24V input types
21.6
24
26.4
5V&12V input types
1.6
2.0
15V&24V input types
5
10.0
Units
V
mA p-p
Absolute Maximum Ratings
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
300°C
550mW
Input voltage VIN,B0505XDP01,B0512XDP01,B0515XDP01 types
7V
Input voltage VIN,B1205XDP01,B1212XDP01,B1215XDP01 types
15V
Input voltage VIN,B1505XDP01,B1512XDP01,B1515XDP01 types
18V
Input voltage
28V
1.Calculated using MIL-HDBK-217FN2 calculation model with nominal input voltage at full load.
MICRODC R ESERVES THE COPYRIGHT
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 4
B-XDP01 Series
OUTPUT CHARACTERISTICS
Parameter
Conditions
Min.
Rated Power
TA=-40°C to 120°C
0.1
Voltage Set Point Accuracy
See tolerance envelope
Line regulation
High VIN to low VIN
Typ.
1.0
Max.
Units
1
W
1.2
%%
Isolation Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Units
Isolation test voltage
Flash tested for 1 second
1000
VDC
Resistance
Viso= 1000VDC
10
GΩ
Conditions
Min.
General Characteristics
Parameter
Typ.
5V input types
110
12V input types
160
15V input types
90
24V input types
80
Max.
Switching frequency
Units
kHz
Temperature Characteristics
Parameter
Conditions
Min.
Specification
All output types
-40
85
-50
130
Storage
Typ.
Max.
Units
℃
5V output types
23
All other output types
28
Case temperature above ambient
TOLERANCE ENVELOPE
B2405XDP01
B1512XDP01,B1515XDP01,B2412XDP01,B2415XDP01
All other types
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.Another 24V& 48V products, please inquire Our technical department!
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 2 of 4
B-XDP01 Series
Technical notes
ISOLATION VOLTAGE
"Hi Pot Test","Flash Tested","Withstand Voltage","Dielectric Withstand Voltage"&”Isolation Test Voltage" are all terms that relate to the same thing, a test voltage.
Applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Professional Power Module B_XDP01 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1KVDC for 1 second.
A question commonly asked is,"What is the continuous voltage that can be applied across the part in normal operation?"
For a part holding no specific agency approvals, such as the B_XDP01 series ,both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC.The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier, but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-acssible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials.
Construction and environment. The B_XDP01 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing. but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
OUTPUT RIPPLE REDUCTION
Output ripple reduction
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: Ceramic chip capacitors are recommended. It is required that the ESR(Equivalent Series Resistance)should be as low as possible.X7R types are recommended.
The voltage rating should be at least twice(except for 15V output),the rated output voltage of the DC/DC converter.
Inductor: The rated current of the inductor should not be less than of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be
such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF(Self Resonant Frequency) should be >20MHz.
CHARACTERISATION TEST METHODS
Ripple & Noise Characterization Method
Ripple and noise measurements are performed with the following test conguration.
C1
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
C2
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less than 100mΩ at 100 KHz
C3
100nF multilayer ceramic capacitor, general purpose
R1
450Ω resistor, carbon lm, ±1% tolerance
R2
50Ω BNC termination
T1
3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specifed values.
Differential Mode Noise Test Schematic
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 3 of 4
B-XDP01 Series
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
FOOTPRINT
14 Pin DIP
14 Pin DIP package
Pin
Function
1
Vin
2
GND
5
-Vout
6
+Vout
7
No Connect
Others
No Connect
TEMPERATURE DERATING GRAPHS
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
RECOMMENDED FOOTPRINT DETAILS
TUBE OUTLINE DIMENSIONS
14 Pin DIP Package
14 Pin DIP Tube
Grid:2.54×2.54mm[0.1×0.1inch]
Diameter:1.00mm[0.039inch]
Unless otherwise stated all dimensions in inches (mm) ±0.5mm.
Tube length (14 Pin DIP) : 20.47 (520mm ±2mm).
Tube Quantity :25
RoHS COMPLIANT INFORMATION
Microdc Professional Power Module,Inc.
This series is compatible with RoHS soldering systems with a peak wave solder temperature of
Tel:0086-20-86000646 E-mail:[email protected]
300°C for 10 seconds. The pin termination finish on the SIP package type is Tin Plate, Hot
Website:http://www.microdc.cn
Dipped over Matte Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate.
Microdc Professional Power module,Inc.makes no representation that
Both types in this series are backward compatible with Sn/Pb soldering systems.
the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or
REACH COMPLIANT INFORMATION
future patent rights. Specifications are subject to change without notice.
This series has proven that this product does not contain harmful chemicals, it also has harmful
©2010Microdc Professional Power Module, Inc. Guangzhou
chemical substances through the registration, inspection and approval.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 4 of 4
Similar pages