MPD MPV1080LS-05RHI Compact pv power, 15w 200 - 1500v input dc/dc con vert er Datasheet

MPV1580L Series
Compact PV Power, 15W
200 - 1500V Input
DC/DC Converters
Electrical Specifications
Key Features:
• 15W Output Power
• 200 - 1500 VDC Input Range
• 4,000 VAC Isolation
• Compact Case
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Start Voltage
Under Voltage Shutdown
• Input Under Volt Protection
• Output Over Volt Protection Inrush Current
Start-Up Time
• -25°C to +70°C Operation
Output
• >300 kHours MTBF
Min.
200
180
170
200 VDC Input
1500 VDC Input
200 VDC Input
1500 VDC Input
Input Current
• Short Circuit Protection
Conditions
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Temperature Coefficient
Over Power Protection
Output Short Circuit
Conditions
Typ.
Max.
1,500
195
185
130
25
Units
VDC
VDC
VDC
mA
50
150
Min.
VIN = MIN to MAX
IOUT = 0% to 100%
See Note 1
Typ.
±2.0
±1.0
±1.0
150
±0.02
A
2.0
S
Max.
Units
%
%
%
mV P - P
%/°C
%IOUT
300
Autorecovery
120
Continuous (Autorecovery)
General
Parameter
Isolation Voltage
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions, See Note 2
Conducted Emissions, See Note 2
ESD
RS
EFT, See Note 3
Surge, See Note 4
CS
Conditions
60 Seconds
Min.
4,000
Typ.
Max.
65
Standard
Criteria
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
B
A
B
B
A
Units
VAC
kHz
Level
Class A
Class A
±6 kV/±8
10V/m
±2 kV
±1 kV
10 Vrms
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-25
+25
-25
Free Air Convection
RH, Non-condensing
Ambient
Max.
+70
+85
Units
°C
°C
95
%
See Mechanical Drawings (Page 3)
Black, Flame Retardant, Non-Conductive Plastic (UL94-V0)
9.57 Oz (270g)
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
300
Typ.
Max.
Units
kHours
Conditions
Wave Soldering (5-10S)
Manual Soldering (3-5S)
Min.
255
350
Typ.
260
360
Max.
265
370
Units
Absolute Maximum Ratings
Parameter
Lead Temperature, See Note 5
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Output
Efficiency
Voltage
Current
(VDC)
(mA, Max)
Current
(mA, Min)
(%, Typ)
Over
Voltage Capacitive
Load
Protection (µF,
Max)
Fuse Rating
Slow-Blow
(mA)
(VDC Typ)
Nominal
Range
MPV1080LS-05RHI
800
200 - 1500
5.0
2,000
0.0
70
8.0
6,000
15A/1,500 VDC
MPV1580LS-12RHI
800
200 - 1500
12.0
1,250
0.0
76
20.0
2,000
15A/1,500 VDC
MPV1580LS-15RHI
800
200 - 1500
15.0
1,000
0.0
77
20.0
1,500
15A/1,500 VDC
MPV1580LS-24RHI
800
200 - 1500
24.0
625
0.0
79
30.0
470
15A/1,500 VDC
Notes:
1. To meet the specified ripple and noise levels, external capacitors are required. See the typical connection information on page three for recommended values. For more information, please
contact the factory.
2. All units will meet EN 55022 (CE/RE) class A with the input circuit shown in the “Typical Connection 2” diagram on page 3. Contact the factory for more information.
3. All units will meet EN 61000-4-4 (±2 kV) with the input circuit shown in the “Typical Connection 2” diagram on page 3. Contact the factory for more information.
4. All units will meet the requirements of EN 61000-4-5 (±1 kV), with the input circuit shown in the “Typical Connection 2” diagram on page 3. Contact the factory for more information.
5. Lead temperature is measured 1.5 mm from the case.
6. Operation at no load will not damage the units, however, they may not meet all specifications.
7. It is recommended that a fuse be used on the input of a power supply for protection. For the MPV1580L-xxRHI series, a 15A/1,500 VDC slow blow should be used.
Derating Curve: Temperature
(Input = 200 - 1500 VDC)
Efficiency Vs Input Voltage - Full Load
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
Derating Curve: Altitude
Efficiency Vs Output Load - VIN = 800V
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Typical Connection 1
The diagram at left illustrates a typical connection of the
MPV1580LS-xxRHI series. Output capacitors C9 and
C10 are filtering components. Capacitor C9 is a ceramic
and C10 is a high frequency, low resistance electrolytic.
The TVS is recommended to protect circuit components if
there is a fault with the converter.
The recommended component values are given in the
table below.
Typical Connection 2: With External EMC Components
Recommended values for components are:
Model
LDM
LCM
C1, C2, C3, C4
C5, C6, C7, C8
R1, R2, R3, R4
C9
C10
TVS
SMBJ7.0A
MPV1080LS-05RHI
MPV1580LS-12RHI
MPV1580LS-15RHI
For applications that require meeting higher EMC standards,
the circuit shown at left is recommended. Some notes on this
diagram (starting with the input circuit) are:
1. It is recommended that an external fuse be used. The
recommended fuse is 15A/1,500V.
2. Capacitors C1, C2, C3 and C4 are input filter components
(connected in series to achieve the required capacitance
level).
3. Capacitors C5, C6, C7 and C8 are also input filter components. Resistors R1, R2, R3 and R4 help to balance the
current across the capacitors.
4. Capacitor C9 is ceramic. This capacitor is used to filter
high frequency noise. A recommended value is given in
the table below.
5. Capacitor C10 is an electrolytic. A low ESR, high frequency
capacitor should be used.The recommended value is given
in the table below.
6. The output TVS will help protect system circuitry if the
converter fails. A recommended value is given in the table
below.
7. Derating on all capacitors should be 80% or more.
330 µH/1A 7 mH/1A
0.1 μF/275 VAC
47 μF/450V
1 M⍀/2W
1.0 μF/50V
120 μF/25V
68 μF/35V
MPV1580LS-24RHI
SMBJ20A
SMBJ30A
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
6
Function
+VIN
-VIN
No Connection
No Connection
-VOUT
+VOUT
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages