Issue: 01 Specification AXHV1012 Oscillator type : VCO – Voltage Controlled Oscillator Parameter min. typ. max. Unit Date: 2005-12-08 Condition 980 1420 MHz @ 25°C Frequency tuning range Frequency adjustment range EFC voltage VC 0 6 V 28 100 MHz/V Tuning sensitivity (∆f / ∆VC) EFC slope positive Frequency stability vs. supply voltage variation (pushing) 3.5 MHz/V vs. load change (pulling) 1 MHz @ ar =12 dB RF output Signal waveform SINUS Amplitude +4.5 +6 dBm RL = 50 Ω Harmonics -17 dBc -105 dBc/Hz @ 100 kHz Phase Noise Supply voltage VS 4.75 5 5.25 V Current consumption (steady state) 20 mA -10 +60 °C Operating temperature range -20 +70 °C Operable temperature range -40 +85 °C Storage temperature range 25.4 x 12.7 x 6.1. mm Enclosure (see drawing) LxWxH 5 gram Weight bulk IEC 60286-3 Packing 1500 V HBM, IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Ordering Code: Model (Specification) AXHV1012 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany Frequency Range [MHz] 980-1420 AXHV1012 page 1(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Enclosure drawing on request Pin connections Output circuit: Pin # Symbol P1 VC P2 RF OUT P3 VS P4 N.C. All GND others OUT Function Control Voltage (EFC) RF Output Supply Voltage Not Connected Ground Typical performance HV1012 f/MHz 1500 1400 1300 1200 1100 1000 900 0 1 2 3 4 5 6 V_tune/V GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXHV1012 page 2(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Sensitivity(MHz/V) HV1012 150 100 50 0 0 1 2 3 V_tune/V 4 5 6 HV1012 P_out/dBm 10 5 P_out/dBm P_out_1st_Harmonic/dBm 0 -5 -10 -15 -20 -25 0 1 2 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany 3 V_tune/V 4 5 AXHV1012 page 3(4) 6 www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Environmental conditions Test IEC 60068 Part ... Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60679-1 clause ... 4.3 2-17 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Bump* 2-29 4.6.6 Free fall* 2-32 4.6.9 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Vibration, sinusoidal* 2-6 4.6.7 Rapid change of temperature Dry heat 2-14 4.6.5 2-2 4.6.14 Damp heat, cyclic* 2-30 4.6.15 Cold 2-1 4.6.16 Climatic sequence* 1-7 4.6.17 Damp heat, steady state* Endurance tests - ageing - extended aging 2-3 4.6.18 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXHV1012 page 4(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]