Green Power Solutions srl Via Venezia 34D - 10088 Volpiano (TO), Italy Phone: +39-011-988 2251 Fax: +39-011-988 1358 Web: www.gpsemi.it e-mail: [email protected] GOB96017 BI-DIRECTIONAL THREE PHASE AC-DC BRIDGE Fuse protection Blown fuse indicators with microswitch Over temperature switches Fan loss detection circuit Snubber for SCR's protections Extractible stacks for easy field service LINE VOLTAGE UP TO 690V DC OUTPUT CURRENT 1700A GOB96017 690 V Line to line voltage Characteristic Conditions Value IDC DC output current 1700 A VINS (rms) Insulation voltage 3000 V THYRISTOR CHARACTERISTICS VGT Gate trigger voltage Tj = 25 °C, V D = 5 V IGT Gate trigger current Tj = 25 °C, V D = 5 V dV/dt VRRM Critical rate of rise off-state voltage Tj= 125 °C 1000 V/us Blocking Voltage Tj = 125 °C 2200 V 3 V 300 mA FUSE TYPE SIBA 2077132.500 VNF Rated voltage 1000 V INF Rated current PVF Power loss At rated current I²t Total I2t At 1000V 500 A 90 W 2 310 kA s MECHANICAL AND THERMAL CHARACTERISTICS Width 620 mm Depth 420 mm Height 1409 mm Mass 170 kg Ta max Max amb. op. Temp. 40 °C Tstg Storage temperature -40/60 °C Document GOB96017T001 THREE PHASE AC-DC BRIDGE GOB96017 T6 T5 T4 T6° T5° T4° T2° T1° T3° T2 T1 T3 A B The part numbering system is reported at the beginning of the Open Assembly section. Customisations are available on request. Please contact factory. In the interest of product improvement Green Power Solutions reserves the right to change any specification given in this data sheet without notice. Document GOB96017T001 GOB96017 THREE PHASE AC-DC BRIDGE + F1 F2 FSW1 F3 TH1 K1 G1 K2 G2 T1 T1° T2 K3 G3 T2° T3 K1° G1° FSW2 T3° K2° G2° K3° G3° FSW3 U TH2 V FSW4 W K4 G4 K5 G5 K6 G6 FSW5 T4 T4° T5 T5° T6 K4° G4° K5° G5° T6° TH3 K6° G6° FSW6 F4 F5 F6 61 62 81 82 TH: THERMOSWITCH FSW: BLOWN FUSE SWITCH 61-62: THERMOSWITCH CIRCUIT CONNECTION 81-82: BLOWN FUSE SWITCH CIRCUIT CONNECTION FAN BOARD BROWN BLACK BLUE GREEN/YELLOW FAN 2 BLUE GREEN/YELLOW BROWN BLACK AC AC NO COM NC FAN 1 PE V3 1 2 U3 FAN CAPACITOR 1 32 2 31 FAN CAPACITOR Cooling: Fan type: Number of fans: Voltage: Current: Frequency: Noise: single phase axial 2 230 V 0.6 A 50/60 Hz 62 dBA U3-V3: MAIN SUPPLY PE: GROUND CONNECTION (GND) 31-32: FAN BOARD CONTACT (CLOSED WHEN FAN RUNNING) In the interest of product improvement Green Power Solutions reserves the right to change any specification given in this data sheet without notice. Document GOB96017T001