ETC GM126401SFAYA-R1 Lcd module spcification Datasheet

Confidential Document
DATA IMAGE
CORPORATION
LCD Module Specification
ITEM NO.: GM126401SFAYA-R1
Table of Contents
1. COVER & CONTENTS ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚
1
2. RECORD OF REVISION ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 2
3. GENERAL SPECIFICATIONS ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 3
4. ABSOLUTE MAXIMUM RATINGS ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚
4
5. ELECTRICAL CHARACTERISTICS ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 6
6. ELECTRO-OPTICAL CHARACTERISTIC ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 6
7. TIMING CHARACTERISTICS ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚
9
8. PIN CONNECTIONS ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 11
9. POWER SUPPLY ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 11
10. BLOCK DIAGRAM ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚
12
11. QUALITY ASSURANCE ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 14
12. LOT NUMBERING SYSTEM ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 18
13. LCM NUMBERING SYSTEM ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 18
14. PRECAUTIONS IN USE LCM ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 19
15. OUTLINE DRAWING ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 20
16 PACKAGE INFORMATION ‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚‚ 21
R&D Dept.
Q.C. Dept.
Eng. Dept.
Prod. Dept.
Version:
Issued Date:
Sheet Code:
Total Pages:
B
2003/4/1
21
Page:
1 / 21
Confidential Document
2.
RECORD OF REVISION
Rev
Date
Item
Page
B
AUG/02/02
11.2.3,
11.3
16-17
AUG/02/02
13
18
1.Change: 11.2.3 Inspection Parameters.
2. Add on11.3 Sampling increase Condition.
New model numbering system is updated
from old P/N# GM12641DS1L1Y-02
APR/01/03
15
20
Modify: OUTLINE DRAWING.
B
Comment
Page:
2 / 21
Confidential Document
3.
GENERAL
SPECIFICATION
Display Format :
128 (W) ×
64 (H)
dots
Dot Size :
0.48 (W) ×
0.48 (H)
mm
View Area :
72.5 (W) ×
39.5 (H)
mm
93 (W) ×
General Dimensions :
70 (H) × 12.5 (T) mm Max.
Weight :
83 g max.
LCD Type :
STN Gray
V STN Yellow
Polarizer mode :
Reflective
V Transflective
Transmissive
FSTN
Negative
View Angle :
V 6 O’clock
12 O’clock
Others
Backlight :
V LED
EL
CCFL
Backlight Color :
V Yellow green
Amber
Blue Green
White
Others
Controller / Driver :
KS0107/KS0108
Temperature Range :
V Normal
Operating 0 to 50°C
Storage -20 to 70°C
Wide Temperature
Operating -20 to 70°C
Storage
-30 to 80°C
Page:
3 / 21
Confidential Document
4. ABSOLUTE MAXIMUM RATINGS
4.1
ELECTRICAL ABSOLUTE MAXIMUM RATINGS
VSS= 0V,
Item
Ta = 25°C
Symbol
Min.
Max.
Unit
Supply Voltage
(Logic)
VDD-VSS
0
8
V
Supply Voltage
(LCD Driver)
VDD-VO
0
16.5
V
VI
VSS-0.3
VDD+0.3
V
Operating Temperature
TOP
0
50
°C
Storage Temperature
TSTG
-20
70
°C
Input Voltage
4.2
ENVIRONMENTAL ABSOLUTE MAXIMUM RATINGS
Item
Ambient Temp
Operating
(Min.)
Max.)
(Min.)
(Max.)
0
50
-20
70
Humidity
Vibration
Shock
Storage
Note (2)
---
Comment
Note (1)
Note(2)
2
4.9M/S
2
29.4M/S
---
Without Condensation
2
XYZ Direction
2
XYZ Direction
19.6M/S
490M/S
Note(1) Ta = 0°C : 50Hr Max.
Note(2) Ta ≤ 40°C : 90% RH Max.
Ta ≥ 40°C : Absolute humidity must be lower than the humidity
of 90% RH at 40°C.
Page:
4 / 21
Confidential Document
4.3 Electronic Static Discharge maximum rating
ESD test method : IEC1000-4-2
Item
Testing environment
Testing equipment
Testing condition
Direct discharge
Indirect discharge
Pass condition
Fail condition
Description
Ambient temperature :15°C to 35 °C
Humidity: 30% to 60 %
LCM ( E.U.T ) : Power up
Manufacture: Noise Ken, Model No. ESD-100L
See drawing 1
0 to ± 6 KV Discharge point, see drawing 2
0 to ± 12KV Discharge point, see drawing 1
No malfunction of unit. Temporary malfunction of unit which
can be recovered by system reset
Non. Recoverable malfunction of LCM or system
F IG 1 E S D T E S T IN G E Q U IP M E N T
D IR E C T D IS C H A R G E
V C P IN D IR E C T D IS C H A R G E
H C P IN D IR E C T D IS C H A R G E
HCP
IS O L A T O R
ESD PO W ER SU PPLY
470k
GROUND LEVEL
W O O D E N T A B L E (T A L L 0 .8 m )
(1)
DIRECT CONTACT DISCHARGE
CONTACT POINT : A.B.C.D
C
D
A
B
(2)
Page:
5 / 21
Confidential Document
5.
ELECTRICAL CHARACTERISTICS
Item
Symbol
Supply Voltage
(Logic)
VDD-VSS
Supply Voltage
(LCD)
VDD-VO
VIH
Input Voltage
VIL
Logic Supply
Current
IDD
Condition
Min.
Typ.
Max.
Unit
4.5
5.0
5.5
V
0°C
9.0
9.5
10.0
25°C
8.6
9.3
9.7
50°C
8.2
8.8
9.2
0.7VSS
--
VDD
VSS
--
0.3VDD
--
3.8
6
mA
Unit
Ref.
-VDD-VSS=5V
V
V
6. ELECTRO-OPTICAL CHARACTERISTICS
ITEM
Symbol
Rise Time
Tr
Condition
Min.
Typ.
Max.
0°C
--
400
600
25°C
--
110
170
0°C
--
500
800
25°C
--
110
170
Fall Time
Tf
Contrast
CR
25°C
--
3
--
θ1~θ2
∅1, ∅2
25°C &
CR≥1.5
60
--
--
-30
--
30
Ff
25°C
--
64
--
View Angle
Frame Frequency
Ms
Note (1)
Ms
Note (3)
Note (2)
Hz
Note (1) & (2) : See next page
Note (3) : Contrast ratio is defined under the following condition:
CR= Brightness of non-selected condition
Brightness of selected condition
( a ).
( b ).
( c ).
( d ).
Temperature ---------- 25°C
Frame frequency ---- 64Hz
Viewing angle -------- θ= 0°, ∅ = 0°
Operating voltage --- 9.3V
Page:
6 / 21
Confidential Document
Note (1) Response time is measured as the shortest period of time possible
between the change in state of an LCD segment as demonstrated below:
+Vop
1/f F
0
-Vop
90%
100%
10%
tr
tf
Condition:
( a ) . Temperature ---------------25°C
( b ) . Frame frequency --------- 64Hz
( c ) . View Angle ----------------- θ = 0°, ∅=0°
( d ) . Operating voltage -------- 9.3V
Note (2) Definition of View Angle
Top – Bottom direction
Right -- Left direction
Top
∅2
θ1
∅1
θ2
Bottom
Left
Right
Page:
7 / 21
Confidential Document
6.1
LED ELECTRO-OPTICAL CHARACTERISTIC
Ta = 25°C
Item
Symbol
Condition
IF = 330mA
Yellow Green
IF = 330mA
Luminous Intensity
IV
Yellow Green
IF = 330mA
Peak Emission
λP
Yellow Green
IF = 330mA
Spectrum Radiation
∆λ
Yellow Green
VR = 8V
Reverse Current
IR
Yellow Green
Note : Measured at the LED backlight unit.
Forward Voltage
VF
Min.
Typ.
Max.
Unit
--
4.2
4.6
V
120
180
--
cd/m2
--
570
--
nm
--
30
--
nm
--
--
0.2
mA
6.2 LED MAXIMUM OPERATING RANGE
Item
6.2.1
Symbol
Yellow Green
Unit
Power Dissipation
PAD
2.3
W
Forward Current
IAF
495
mA
Reverse Voltage
VR
8
V
LED ARRAY BLOCK DIAGRAM
A
2 Dies X33 =66
K
Page:
8 / 21
Confidential Document
7. TIMING CHARACTERISTICS
MPU Interface
Characteristic
Symbol
Min
Typ
Max
Unit
tC
1000
--
--
ns
E High Level Width
tWH
450
--
--
ns
E Low Level Width
tWL
450
--
--
ns
E Rise Time
tR
--
--
25
ns
E Fall Time
tF
--
--
25
ns
Address Set-Up Time
tASU
140
--
--
ns
Address Hold Time
tAH
10
--
--
ns
Data Set-Up Time
tSU
200
--
--
ns
Data Delay Time
tD
--
--
320
ns
Data Hold Time (Write)
tDHW
10
--
--
ns
Data Hold Time (Read)
tDHR
20
--
--
ns
E Cycle
Page:
9 / 21
Confidential Document
tC
E
2.0V
0.8V
tWH
tWL
tR
tASU
tAH
tASU
R/W
CS1-CS2,RS
tF
tAH
0.8V
2.0V
tDSU
tDH
DB0-7
MPU write timing
tC
E
tWL
tWH
tK
R/W
tF
tASU
tAH
tASU
tAH
CS1,CS2,RS
tD
tDH
DB0-7
MPU read timing
Page:
10 / 21
Confidential Document
8.
9.
PIN CONNECTIONS
No.
1
2
3
4
Symbol
VSS
VDD
V0
D/I
5
R/W
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
E
DB0
DB1
DB2
DB3
DB4
DB5
DB6
DB7
CS1
CS2
/RST
VEE
LEDK
LEDA
Function
Ground (0V)
+5V
Power Supply For LCD Drive
L→ Instructions H→ Data
H→ Data Read (LCD → MPU)
L→ Data Write (LCD ← MPU)
Enable Signal
Data Bus Line
Chip select for IC1, Active high
Chip select for IC2, Active high
Reset, Active LOW
Negative Voltage Output
LED Cathode. Power Supply LED Anode. Power Supply +
POWER SUPPLY
VDD
+5V
LCM
VSS
VR=10K
VO
LED A
Backlight
0V
LED K
VEE
Page:
11 / 21
Confidential Document
10. BLOCK DIAGRAM
Common
64Com
LCD PANEL
128 × 64 DOTS
Drive
VSS
VDD
VEE
V0
LCD
DC TO DC
(-5V)
64Seg
R/W
D/I
E
DB0
64Seg
Segment
Segment
Driver 1
Driver 2
DB7
CS1
CS2
10K
/RST
Page:
12 / 21
Confidential Document
DISPLAY CONTROL INSTRUCTION
The display control instructions control the internal state of the KS0108B . Instruction is
received from MPU to KS0108B for the display control. The following table shows
various instructions.
Instruction
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
Display ON/OFF
L
L
L
Set Address
L
L
L
Set Page
(X address)
L
L
H
Display Start
Line
L
L
H
B
U
S
Y
Status Read
L
H
Write Display
Data
H
L
Read Display
Data
H
H
Function
Controls the display on
or off. Internal status
and
L
H
H
H
H
H L/H
display RAM data is not
affected.
L : OFF, H : ON
Sets the Y address in the
H
Y address (0-63)
Y address counter.
Page
Sets the X address at the
L
H
H
H
(0-7)
X address counter.
Indicates the display data
Display start line
RAM displayed at the
H
(0-63)
top
of the screen
Read status.
R
BUSY L: Ready
H: In operation
ON E
L
S
L
L
L
L ON/OFF L: Display ON
/
H: Display OFF
OFF E
RESET L: Normal
T
H: Reset
Writes data (DB0:7)into
display data RAM. After
Write Data
writing instruction, Y
address is increased by
1 automatically.
Read data (DB0:7) from
Read Data
display data RAM to the
data bus.
Page:
13 / 21
Confidential Document
11.
QUALITY ASSURANCE
11.1 Test Condition
11.1.1 Temperature and Humidity(Ambient Temperature)
Temperature : 20 ± 5°C
Humidity
: 65 ± 5%
11.1.2 Operation
Unless specified otherwise, test will be conducted with LCM in operation.
11.1.3 Container
Unless specified otherwise, vibration test will be conducted on module only.
11.1.4 Test Frequency
Single cycle.
11.1.5 Test Method
No.
1
2
3
4
5
6
Parameter
High Temperature Operating
Low Temperature Operating
High Temperature Storage
Low Temperature Storage
Vibration Test
(Non-operation state)
Damp Proof Test
(Non-operation state)
Shock Test
(Non-operation state)
Conditions
50 ± 2 °C
0 ± 2 °C
70 ± 2 °C
-20 ± 2 °C
Total fixed amplitude : 1.5mm
Vibration Frequency : 10 ~ 55Hz
One cycle 60 seconds to 3 directions
of X.Y.Z. for each 15 minutes
40°C ± 2°C, 90~95%RH, 96h
To be measured after dropping from
60cm high once concrete surface in
packing state
Note 1: Returned under normal temperature and humidity for 4 hrs.
Note 2: No dew condensation to be observed.
Note 3: No change on display and in operation under the test condition
7
Regulations
Note 3
Note 3
Note 3
Note 3
Note 3
Note 1,2
Note 3
Page:
14 / 21
Confidential Document
11.2 Inspection condition
11.2.1 Inspection conditions
The LCD shall be inspected under 40W white fluorescent light.
45°
11.2.2 Definition of applicable Zones
B
LCD
A
BEZEL
PCB
A : Display Area
B : Non-Display Area
Page:
15 / 21
Confidential Document
11.2.3 Inspection Parameters
No.
1
Parameter
Criteria
Black or White spots
Zone
Dimension
D < 0.15
0.15≤ D< 0.2
0.2 ≤ D ≤ 0.25
D ≤ 0.3
2
Scratch,
Acceptable
Class
number
Of
Defects
A
B
∗
∗
4
4
Minor
2
2
0
1
D = (Long + Short) / 2
AQL
Level
2.5
* : Disregard
Substances
Class
Acceptable
Of
number
X (mm) Y(mm)
Defects
A
B
∗
∗
∗
0.04 ≥ W
4
4
3.0 ≥ L 0.06 ≥ W
Minor
2
3
2.0 ≥ L 0.08 ≥ W
0
1

0.1 < W
X : Length Y : Width
∗ : Disregard
Total defects should not exceed 4/module
Zone
3
AQL
Level
2.5
Air Bubbles
(between glass & polarizer)
Dimension
D ≤ 0.15
Acceptable
number
A
B
∗
∗
0.15 < D ≤ 0.25
2
Zone
∗
Class
of
Defects
AQL
Level
Minor
2.5
0
1
0.25 < D
∗ : Disregard
Total defects shall not excess 3/module.
4
Uniformity of Pixel
(1)
Pixel shape (with Dent)
0.152
Page:
16 / 21
Confidential Document
(2)
Pixel shape ( with Projection)
Should not be connected to
next pixel
0.152
(3)
Pin hole
X
4
Uniformity of Pixel
Y
( X + Y )/2 ≤ 0.02mm
(Less than 0.1 mm is no counted)
(4)
Deformation
X ( X + Y ) / 2 ≤ 0.3mm
Y
Total acceptable number : 1/pixel, 5/cell
Major
Class of
defects
AQL 0.65%
AQL 1.00%
Minor
AQL 2.5%
Definition
It is a defect that is likely to result in failure or to
reduce materially the usability of the product for the
intended function.
It is a defect that is likely to assembly size and not
result in functioning problem.
It is a defect that will not result in functioning problem
with deviation classified.
11.3 Sampling Condition
Unless otherwise agree in written, the sampling inspection shall be
applied to the incoming inspection of customer.
Lot size: Quantity of shipment lot per model.
Sampling type: normal inspection, single sampling
Inspection level: Level II
Sampling table: MIL-STD-105E
Page:
17 / 21
Confidential Document
12.
LOT NUMBERING SYSTEM
9
7
4
2
Production week number
Production year
13.
LCM NUMBERING SYSTEM
GM 126401
S
F
A
Y
A – R1
VERSION :R1
View direction & Temp. Range
A–Bottom view 6H & Normal temp.
B–Bottom view 6H & Wide temp.
C–Top View & Normal temp.
D–Top View & Wide temp.
Backlight Color
B –Blue
A –Amber
Y - yellow
Backlight
S –edge light LED B/L
E –EL
A –Array LED B/L
MODE
M – transmissive
F – transflective
R – Reflective
N - Negative
LCD type
G –STN Gray
S – STN Yellow
N – TN
Series code
126401 –128 Dots X 64 Dot, 0 LCD type,1 PCB type
Model type
CM – Character Module
GM – Graphic Module
CX – Custom Character Module
GX – Custom Graphic Module
Page:
18 / 21
Confidential Document
14.
PRECAUTION FOR USING LCM
1. LIQUID CRYSTAL DISPLAY (LCD)
LCD is made up of glass, organic sealant, organic fluid, and
polymer based polarizers. The following precautions should
be taken when handing,
(1). Keep the temperature within range of use and storage.
Excessive temperature and humidity could cause
polarization degredation, polarizer peel off or bubble.
(2). Do not contact the exposed polarizers with anything
harder than an HB pencil lead. To clean dust off the
display surface, wipe gently with cotton, chamois or other
soft material soaked in petroleum benzin.
(3). Wipe off saliva or water drops immediately. Contact
with water over a long period of time may cause polarizer
deformation or color fading, while an active LCD with
water condensation on its surface will cause corrosion of
ITO electrodes.
(4). Glass can be easily chipped or cracked from rough
handling, especially at corners and edges.
(5). Do not drive LCD with DC voltage.
2. Liquid Crystal Display Modules
2.1 Mechanical Considerations
LCM are assembled and adjusted with a high degree of
precision. Avoid excessive shocks and do not make any
alterations or modifications. The following should be noted.
(1). Do not tamper in any way with the tabs on the metal
frame.
(2). Do not modify the PCB by drilling extra holes,
changing its outline, moving its components or modifying
its pattern.
(3). Do not touch the elastomer connector, especially
insert an backlight panel (for example, EL).
(4). When mounting a LCM make sure that the PCB is not
under any stress such as bending or twisting . Elastomer
contacts are very delicate and missing pixels could result
from slight dislocation of any of the elements.
(5). Avoid pressing on the metal bezel, otherwise the
elastomer connector could be deformed and lose contact,
resulting in missing pixels.
2.2. Static Electricity
LCM contains CMOS LSI’s and the same precaution for
such devices should apply, namely
(1). The operator should be grounded whenever he/she
comes into contact with the module. Never touch any of the
conductive parts such as the LSI pads, the copper leads on
the PCB and the interface terminals with any parts of the
human body.
(2). The modules should be kept in antistatic bags or other
containers resistant to static for storage.
(3). Only properly grounded soldering irons should be
used.
(4). If an electric screwdriver is used, it should be well
grounded and shielded from commutator sparks.
(5) The normal static prevention measures should be
observed for work clothes and working benches; for the
latter conductive (rubber) mat is recommended.
(6). Since dry air is inductive to static, a relative
humidity of 50-60% is recommended.
2.3
Soldering
(1). Solder only to the I/O terminals.
(2). Use only soldering irons with proper grounding
and no leakage.
(3). Soldering temperature : 280°C ± 10°C
(4). Soldering time: 3 to 4 sec.
(5). Use eutectic solder with resin flux fill.
(6). If flux is used, the LCD surface should be covered
to avoid flux spatters. Flux residue should be removed
after wards.
2.4 Operation
(1). The viewing angle can be adjusted by varying the
LCD driving voltage V0.
(2). Driving voltage should be kept within specified
range; excess voltage shortens display life.
(3). Response time increases with decrease in
temperature.
(4). Display may turn black or dark blue at
temperatures above its operational range; this is
(however not pressing on the viewing area) may cause
the segments to appear “fractured”.
(5). Mechanical disturbance during operation (such as
pressing on the viewing area) may cause the segments to
appear “fractured”.
2.5 Storage
If any fluid leaks out of a damaged glass cell, wash off
any human part that comes into contact with soap and
water. Never swallow the fluid. The toxicity is extremely
low but caution should be exercised at all the time.
2.6 Limited Warranty
Unless otherwise agreed between DATA IMAGE and
customer, DATA IMAGE will replace or repair any of its
LCD and LCM which is found to be defective
electrically and visually when inspected in accordance
with DATA IMAGE acceptance standards, for a period
on one year from date of shipment. Confirmation of such
date shall be based on freight documents. The
warranty liability of DATA IMAGE is limited to repair
and/or replacement on the terms set forth above. DATA
IMAGE will not responsible for any subsequent or
consequential events.
Page:
19 / 21
Confidential Document
15
OUTLINE DRAWING
Page:
20 / 21
Confidential Document
16. PACKAGE INFORMATION
Anti-static Bag
Module
Page:
21 / 21
Similar pages