HuaXinAn NT90TP-A Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications. Datasheet

NT90TP (T92)
NT90TP (T92)
Safety approvals
Safety approval
Load
UL&CUR
NO:40A/240VAC 30A/277VAC
NC: 30A/240VAC,30VDC 20A/277VAC
2HP 250VAC
1 12 HP 250VAC TV-5
HP:A 1HP/16AFLA/120VAC
2HP/12AFLA/240VAC
B 30LRA/10AFLA/120VAC
30LRA/10AFLA/240VAC
Insulation
B-class
F-class
T V
NO: 40A/240VAC 14VDC
NC: 30A/240VAC 14VDC
Insulation B-class
F-class
CQC
NO: 30A/240VAC
NC: 20A/240VAC
03001003503
R
32.4(50) 27 20
32.4(50) 27 28.2
C
US
E174722
R50126373
Features
Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration,
high reliability, long life.
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications.
Reference Data
Ordering Information
N90TP
H
L
A S
1
2
3
4
1
2
3
4
5
DC12V
5
6
Part number NT90TP T92
NT90TP 2
Load H:30A N:40A
High NIL: Standard L: Low profile type
Contact arrangement A:1A B:1B C:1C
Enclosure S: Sealed type D: Dust cover
E: Covered
C
B
0.9
7
8
9
6 Coil rated Voltage(V) AC:12,24, 110,120,220
DC:3,5,6,9,12,15,18,24,48,110
7 Contact material C: AgCdO S: AgSnO2
8 Resist heat class B:130
F:155
9 Coil power consumption 0.6:0.6W 0.9:0.9W
NIL:2VA
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
1A SPSTNO
1B SPSTNC
1C SPDT(B-M)
AgCdO
AgSnO2
NO:30A/240VAC,14VDC; NC:20A/240VAC;30A/14VDC
NO:40A/240VAC,30VDC; NC:30A/240VAC,30VDC (0.9W)
NO:30A/277VAC;NC:20A/277VAC
Motor load 2HP 250VAC 1.5HP 250V
Lamp load TV-5
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
life
Mechanical
1100W 7200VA
110VDC 300VAC
30m
105
107
Max. Switching Current:40A
Item 4.12 of IEC 61810-7
Item 4.30 of IEC 61810-7
Item 4.31 of IEC 61810-7
Coil Parameter
AC Coil Parameter
Dash
numbers
012AC
024AC
110AC
120AC
220AC
Rated voltage
VAC
Rated
Max
12
24
110
120
220
15.6
31.2
143
156
286
Rated
current
mA
187
95
20
16.5
6.4
Coil
resistance
10%
27
120
2360
3040
13490
Pick up
voltage
VAC(max)
(75%of
rated
voltage)
Release
voltage
VAC(min)
(30%of
rated
voltage)
Coil
power
9.0
18.0
82.5
90.0
165.0
3.6
7.2
33.0
36.0
66.0
2VA
Operate
Time
ms
Release
Time
ms
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
117
Ningbo Huaguan Electronics Corporation LTD.
118
NT90TP (T92)
Coil Parameter
Dimensions
DC Coil Parameter
7.8
10.2
0.307
0.252
6.4
0.110
27.5Max.
1.083max.
0.787max. 0.307
20 Max. 7.8
2.2
0.087
50.2 Max.
1.976max.
50.2
1.976max.
NT90TPL
NT90TP
NC
NC
0.007
0.606
0.252
0.031
0.007
3-6.4X0.8
15.4 0.2
0.189
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
0.484
R0.071
COM
NT90TP 2
12.3 0.2
0.020 0.189
2-R1.8
3.6
N0
2-0.5X4.8
0.142
10
0.401
15
1.713
4.8 0.2
0.6
10.2 0.2
NC
0.007
43.5
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.8
0.110
0.007
7.7 0.2
0.303
0.007
27.5 Max.
1.083max.
32.5Max.
min (at 500VDC)
Between contacts
Between contact and coil
50Hz 1500V
50Hz 2500V
200m/s2
11ms
10~55Hz double amplitude 1.5mm
10N
235
2
3 0.5s
-55~100
-55~125
85% (at 40 )
35g Low profile type 37g
Item 7 of IEC 61810-5
COM
COM
COM
Item 6 of IEC 61810-5
Item 6 of IEC 61810-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua2
IEC68-2-20 Test Ta method 1
IEC68-2-3 Test Ca
1.110max.
1000M
2.2
Insulation Resistance
Dielectric Strength
1.280max.
N0
28.2 Max.
N0
0.087
Operation condition
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
2.8
0.704
32.5Max.
1.280max.
27.5 Max.
1.083max.
32.5Max.
1.280max.
2.8
7.7
0.303
17.9
0.110
0.142
0.008
3.8 0.2
2.8
0.110
NC
NO
COM
0.150
0.303
17.9
0.704
3.6
7.7
0.401
7.8
0.3
0.5
0.6
0.9
1.2
1.5
1.8
2.4
4.8
11.0
10
COM
0.307
2.25
3.75
4.50
6.75
9.00
10.25
13.50
18.00
36.00
82.50
2-R1.8
0.252
15
42
60
135
240
375
540
960
3840
20167
15
0.606
R0.071
NC
NO
0.110
3.9
6.5
7.8
11.7
15.6
19.5
23.4
31.2
62.4
143
R0.071
0.9
0.110
15.4
6.4
3
5
6
9
12
15
18
24
48
110
0.020
2.8
003-600
005-600
006-600
009-600
012-600
015-600
018-600
024-600
048-600
110-600
2-0.5x2.8
15.4
0.606
2-R1.8
28.2Max.
1.110max.
0.3
0.5
0.6
0.9
1.2
1.5
1.8
2.4
3.6
4.8
11.0
1.713
0.110
2.2
2.25
3.75
4.50
6.75
9.00
10.25
13.50
18.00
27.00
36.00
82.50
0.020
0.087
10
28
40
90
160
250
360
640
1440
2560
13445
43.5
2-0.5x2.8
0.008
3.9
6.5
7.8
11.7
15.6
19.5
23.4
31.2
46.8
62.4
143
Release
Time
ms
3.8 0.2
3
5
6
9
12
15
18
24
36
48
110
Operate
Time
ms
0.150
003-900
005-900
006-900
009-900
012-900
015-900
018-900
024-900
036-900
048-900
110-900
1.713
Coil
power
W
10.2
Release
voltage
VDC(min)
(10%of
rated
voltage)
0.401
Max
Pick up
voltage
VDC(max)
(75%of
rated
voltage)
3.6
Rated
Coil
resistance
10%
0.142
Dash
numbers
Rated voltage
VDC
mm /inch
43.5
50.2Max.
1.976max.
NT90TP
Wiring diagram
NOTES 1). Dimensions are in millimeters.
2). Inch equivalents are given for general information only.
NT90TP2
Dimensions
Reference Data
Safety approvals
Load
119
UL&CUR
NO:40A/240VAC 30A/277VAC
NC:30A/240VAC,30VDC 20A/277VAC
2HP 250VAC TV-5
1 12 HP 250VAC
HP:A 1HP/16AFLA/120VAC
2HP/12AFLA/240VAC
B 30LRA/10AFLA/120VAC
30LRA/10AFLA/240VAC
Insulation B-class
F-class
T V
NO:40A/240VAC 14VDC
NC:30A/240VAC 14VDC
Insulation B-class
F-class
CQC
NO:30A/240VAC
NC:20A/240VAC
12
10
8
6
4
Time (m se c)
Safety approval
Ningbo Huaguan Electronics Corporation LTD.
120
Similar pages