NT90TP (T92) NT90TP (T92) Safety approvals Safety approval Load UL&CUR NO:40A/240VAC 30A/277VAC NC: 30A/240VAC,30VDC 20A/277VAC 2HP 250VAC 1 12 HP 250VAC TV-5 HP:A 1HP/16AFLA/120VAC 2HP/12AFLA/240VAC B 30LRA/10AFLA/120VAC 30LRA/10AFLA/240VAC Insulation B-class F-class T V NO: 40A/240VAC 14VDC NC: 30A/240VAC 14VDC Insulation B-class F-class CQC NO: 30A/240VAC NC: 20A/240VAC 03001003503 R 32.4(50) 27 20 32.4(50) 27 28.2 C US E174722 R50126373 Features Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life. Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications. Reference Data Ordering Information N90TP H L A S 1 2 3 4 1 2 3 4 5 DC12V 5 6 Part number NT90TP T92 NT90TP 2 Load H:30A N:40A High NIL: Standard L: Low profile type Contact arrangement A:1A B:1B C:1C Enclosure S: Sealed type D: Dust cover E: Covered C B 0.9 7 8 9 6 Coil rated Voltage(V) AC:12,24, 110,120,220 DC:3,5,6,9,12,15,18,24,48,110 7 Contact material C: AgCdO S: AgSnO2 8 Resist heat class B:130 F:155 9 Coil power consumption 0.6:0.6W 0.9:0.9W NIL:2VA Contact Data Contact Arrangement Contact Material Contact Rating (resistive) 1A SPSTNO 1B SPSTNC 1C SPDT(B-M) AgCdO AgSnO2 NO:30A/240VAC,14VDC; NC:20A/240VAC;30A/14VDC NO:40A/240VAC,30VDC; NC:30A/240VAC,30VDC (0.9W) NO:30A/277VAC;NC:20A/277VAC Motor load 2HP 250VAC 1.5HP 250V Lamp load TV-5 Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical 1100W 7200VA 110VDC 300VAC 30m 105 107 Max. Switching Current:40A Item 4.12 of IEC 61810-7 Item 4.30 of IEC 61810-7 Item 4.31 of IEC 61810-7 Coil Parameter AC Coil Parameter Dash numbers 012AC 024AC 110AC 120AC 220AC Rated voltage VAC Rated Max 12 24 110 120 220 15.6 31.2 143 156 286 Rated current mA 187 95 20 16.5 6.4 Coil resistance 10% 27 120 2360 3040 13490 Pick up voltage VAC(max) (75%of rated voltage) Release voltage VAC(min) (30%of rated voltage) Coil power 9.0 18.0 82.5 90.0 165.0 3.6 7.2 33.0 36.0 66.0 2VA Operate Time ms Release Time ms CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 117 Ningbo Huaguan Electronics Corporation LTD. 118 NT90TP (T92) Coil Parameter Dimensions DC Coil Parameter 7.8 10.2 0.307 0.252 6.4 0.110 27.5Max. 1.083max. 0.787max. 0.307 20 Max. 7.8 2.2 0.087 50.2 Max. 1.976max. 50.2 1.976max. NT90TPL NT90TP NC NC 0.007 0.606 0.252 0.031 0.007 3-6.4X0.8 15.4 0.2 0.189 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 0.484 R0.071 COM NT90TP 2 12.3 0.2 0.020 0.189 2-R1.8 3.6 N0 2-0.5X4.8 0.142 10 0.401 15 1.713 4.8 0.2 0.6 10.2 0.2 NC 0.007 43.5 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.8 0.110 0.007 7.7 0.2 0.303 0.007 27.5 Max. 1.083max. 32.5Max. min (at 500VDC) Between contacts Between contact and coil 50Hz 1500V 50Hz 2500V 200m/s2 11ms 10~55Hz double amplitude 1.5mm 10N 235 2 3 0.5s -55~100 -55~125 85% (at 40 ) 35g Low profile type 37g Item 7 of IEC 61810-5 COM COM COM Item 6 of IEC 61810-5 Item 6 of IEC 61810-5 IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua2 IEC68-2-20 Test Ta method 1 IEC68-2-3 Test Ca 1.110max. 1000M 2.2 Insulation Resistance Dielectric Strength 1.280max. N0 28.2 Max. N0 0.087 Operation condition Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 2.8 0.704 32.5Max. 1.280max. 27.5 Max. 1.083max. 32.5Max. 1.280max. 2.8 7.7 0.303 17.9 0.110 0.142 0.008 3.8 0.2 2.8 0.110 NC NO COM 0.150 0.303 17.9 0.704 3.6 7.7 0.401 7.8 0.3 0.5 0.6 0.9 1.2 1.5 1.8 2.4 4.8 11.0 10 COM 0.307 2.25 3.75 4.50 6.75 9.00 10.25 13.50 18.00 36.00 82.50 2-R1.8 0.252 15 42 60 135 240 375 540 960 3840 20167 15 0.606 R0.071 NC NO 0.110 3.9 6.5 7.8 11.7 15.6 19.5 23.4 31.2 62.4 143 R0.071 0.9 0.110 15.4 6.4 3 5 6 9 12 15 18 24 48 110 0.020 2.8 003-600 005-600 006-600 009-600 012-600 015-600 018-600 024-600 048-600 110-600 2-0.5x2.8 15.4 0.606 2-R1.8 28.2Max. 1.110max. 0.3 0.5 0.6 0.9 1.2 1.5 1.8 2.4 3.6 4.8 11.0 1.713 0.110 2.2 2.25 3.75 4.50 6.75 9.00 10.25 13.50 18.00 27.00 36.00 82.50 0.020 0.087 10 28 40 90 160 250 360 640 1440 2560 13445 43.5 2-0.5x2.8 0.008 3.9 6.5 7.8 11.7 15.6 19.5 23.4 31.2 46.8 62.4 143 Release Time ms 3.8 0.2 3 5 6 9 12 15 18 24 36 48 110 Operate Time ms 0.150 003-900 005-900 006-900 009-900 012-900 015-900 018-900 024-900 036-900 048-900 110-900 1.713 Coil power W 10.2 Release voltage VDC(min) (10%of rated voltage) 0.401 Max Pick up voltage VDC(max) (75%of rated voltage) 3.6 Rated Coil resistance 10% 0.142 Dash numbers Rated voltage VDC mm /inch 43.5 50.2Max. 1.976max. NT90TP Wiring diagram NOTES 1). Dimensions are in millimeters. 2). Inch equivalents are given for general information only. NT90TP2 Dimensions Reference Data Safety approvals Load 119 UL&CUR NO:40A/240VAC 30A/277VAC NC:30A/240VAC,30VDC 20A/277VAC 2HP 250VAC TV-5 1 12 HP 250VAC HP:A 1HP/16AFLA/120VAC 2HP/12AFLA/240VAC B 30LRA/10AFLA/120VAC 30LRA/10AFLA/240VAC Insulation B-class F-class T V NO:40A/240VAC 14VDC NC:30A/240VAC 14VDC Insulation B-class F-class CQC NO:30A/240VAC NC:20A/240VAC 12 10 8 6 4 Time (m se c) Safety approval Ningbo Huaguan Electronics Corporation LTD. 120