XP Power ECL10US12 Ac-dc power supply Datasheet

AC-DC
10 Watts
xppower.com
ECL10 Series
•
Ultra Compact Size
•
Low Cost
•
Single Outputs from 3.3 to 48 V
•
PCB Mount & Open Frame
•
Encapsulated PCB Mount
•
Class II
•
Peak Load Capability
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Input Protection
General
•
•
•
•
•
•
85-264 VAC (120-370 VDC)
47-63 Hz
0.20 A rms at 230 VAC
20 A at 115 VAC, 40 A at 230 VAC,
Class II construction no earth
Internal 1 A fuse
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
•
Ripple & Noise
•
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
See tables
±5% (not encapsulated units)
±1%
No minimum load required
2 s max
14 ms max
16 ms typical at full load &115 VAC
±0.5% max
±1% max
4% max deviation, recovery to within
1% in 500 µs for a 25% load change
3.3-5 V versions: 50 mV pk-pk,
12-15 V versions: 120 mV pk-pk,
24-48 V versions: 200 mV pk-pk,
20 MHz BW
115-135% Vnom, recycle input to reset
120-150%
Trip and restart (Hiccup mode)
0.05%/°C
Output
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
•
•
•
•
•
See tables
3000 VAC Input to Output
70 kHz typical
5.5 W/In3 (PCB mount version)
>450 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • -20 °C to +70 °C, derate linearly from
100% at +50 °C to 50% at +70 °C
Cooling
• Convection-cooled
Operating Humidity
• 95% RH, non-condensing
Storage Temperature
• -40 °C to +85 °C
Operating Altitude
• 3000 m
Vibration
• 2 g, 10 Hz to 500 kHz, 10 mins/cycle,
60 mins each cycle
EMC & Safety
Emissions
Harmonic Currents
ESD Immunity
Radiated Immunity
•
•
•
•
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
Dips & Interruptions
•
•
•
•
•
Safety Approvals
•
EN55022, level B conducted & radiated
EN61000-3-2, EN61000-3-3
EN61000-4-2, level 3 Perf Criteria A
EN61000-4-3, 10 V/m 80% mod
Perf Criteria A
EN61000-4-4, level 3 Perf Criteria A
EN61000-4-5, level 3 Perf Criteria A
EN61000-4-6, 10 Vrms Perf Criteria A
EN61000-4-8, 10 A/m Perf Criteria A
EN61000-4-11, 70% UT for 10 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf Criteria A, B, B
EN60950, UL60950,
CSA22.2 No. 234 per cUL
Output
Power
8.6 W
10 W
10 W
10 W
10 W
10 W
10 W
Output Current
Output
Voltage
3.3 VDC
5.0 VDC
9.0 VDC
12.0 VDC
15.0 VDC
24.0 VDC
48.0 VDC
Nominal
2.60 A
2.00 A
1.10 A
0.83 A
0.67 A
0.42 A
0.21 A
Model
Number(2)
ECL10US03^†
ECL10US05^†
ECL10US09^†
ECL10US12^†
ECL10US15^†
ECL10US24^†
ECL10US48^†
Efficiency
Peak(1)
3.38 A
2.60 A
1.43 A
1.08 A
0.87 A
0.55 A
0.27 A
72%
75%
78%
78%
80%
82%
82%
Notes
1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal.
2. Add suffix to model number to define type: add ‘-P’ for PCB mount, add ‘-T’ for chassis mount, add ‘-E’ for encapsulated.
† Available from Farnell. See pages 204-206.
^ Available from Newark. See pages 207-208.
Mechanical Details
Open Frame - PCB Mount (-P)
0.800
(20.32)
2.000
(50.80)
+Vo
ACN
1.000
(25.40)
0.400
(10.16)
V Adj.
0.100
(2.54)
0.100
(2.54)
Encapsulated (-E)
0.100
(2.54)
-Vo
ACL
0.180
(45.72)
0.910
(23.00)
0.900
(22.86)
0.170
(4.40)
0.150
(3.80)
4 x ø 0.040 (ø1.00)
0.730
(18.46)
0.390
(10.00)
1.070
(27.20)
ø 0.070 (ø1.80)
0.800 ±0.012 (20.32 ±0.30)
ø 0.040 (ø1.00)
0.130 (3.40)
1.800
(45.72)
Open Frame - Chassis Mount (-T)
2.060
(52.41)
2.600
(66.04)
4-ø0.126 (ø3.20)
1.000
(25.40)
0.685
(17.40)
0.157
(4.00)
+Vo
-Vo
ACN
ACL
0.157
(4.00)
1.800 ±0.012 (45.72 ±0.30)
ACL
2.285 (58.04)
0.727
(18.47)
TOP VIEW
-Vo
0.130
(3.40)
V Adj.
ACN
+Vo
0.400 ±0.012 (10.16 ±0.30)
0.850
(21.59)
Notes
1. Dimensions in inches (mm).
2. Tolerances: x.xx = ± 0.02 (x.x = ± 0.5)
x.xxx = ± 0.01 (x.xx = ± 0.25)
Mating Connectors (Chassis mount only)
Input Connector: JST PHR-3
Output Connector: JST PHR-2
Crimps: SPH-002T-P0.5S
Cable harness with 300 mm wire available, order part no. ECL10 LOOM KIT
10-Oct-08
AC-DC
ECL10
Models and Ratings
Similar pages