MPD MPA150X-24Z Compact 1u 150w single output power factor corrected ac/dc power supply Datasheet

MPA150 Series
Compact 1U 150W
Single Output
Power Factor Corrected
AC/DC Power Supplies
Key Features:
• Compact 1U 150W Supply
• PFC to EN61000-3-2 “A”
• UL, cUL, TUV Approvals
• CE Certified
• FCC Class B Emissions
• 3 - 56 V Output Voltages
• Auto Selectable AC Input
• 600W Peak Power
• Four Mechanical Options
Only
5 x 3.2 x
1.5 in!!
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice
notice.
Input
Parameter
Input Voltage Range
Conditions
Autoranging
Input Frequency
Input Current, Full Load
Inrush Current, Cold Start
Leakage Current
Power Factor Correction
Input Protection
Min.
90
180
47
Typ.
110 - 120 VAC
4
200 - 240 VAC
2
110 VAC
220 VAC
240 VAC
1.5
Meets EN61000-3-2 Class A
T4A/250V Fuse
Max.
132
264
63
Units
VAC
Hz
A
35
70
A
mA
Output
Parameter
Output Voltage Adjustment
Output Regulation (Note 1)
Hold Time
Ripple & Noise (20 MHz) (Note 2)
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time (Note 3)
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Conditions
Min.
Typ.
Max.
±5.0
±1.0
110 VAC, 80% Load
20
See Model Selection Guide
Foldback with Autorecovery
110
140
>130% of Rated Output Voltage. Recycle AC Input.
>+85ºC Ambient with Autorecovery
±0.04
2.5
50% Load Change
5
At Turn On/Off
±5.0
120 VAC
1
Continuous With Autorecovery
By Trim Pot
Units
%
%
mSec
%
%/ºC
mS
%
%
S
General
Parameter
Isolation Voltage (Note 4)
Switching Frequency
MicroPower Direct Interface Signals
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Power Supply On
Power Good Signal
Remote On/Off
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
Max.
Units
VAC
25
kHz
Green LED (LED1) on the PCB
PG on CN1. Goes TTL high 100 to 500 mS after regulation. Goes low at
least 1 mS before the loss of regulation. Will sink 100 mA.
RMSW on CN1. A TTL low signal inhibits the output. Hiccup Mode
Environmental
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Conditions
Min.
Typ.
Max.
Ambient
0
+25
+50
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
See Model Selection Guide
RH, Non-condensing
90
Units
ºC
ºC
%
Reliability Specifications
Parameter
MTBF
Safety Standards
EEMI Compliance
EMS Immunity Compliance
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
100
kHours
UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950)
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3
EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD)
Model Selection Guide
Model
Number
MPA150x-03z
MPA150x-05z
MPA150x-12z
MPA150x-18z
MPA150x-24z
MPA150x-48z
Output Voltage
Factory
Range
PreSet
3.3 VDC
3.0 - 4.0 VDC
5 VDC
5.0 - 6.0 VDC
12 VDC 12.0 - 16.0 VDC
18 VDC 17.0 - 23.0 VDC
24 VDC 24.0 - 30.0 VDC
48 VDC 35.0 - 56.0 VDC
Max. Output Current (Note 5,6,7)
16 CFM
Convection Min.
(U/w Air, F)
30.00A
30.00A
12.50A
8.33A
6.25A
3.12A
Notes:
1. Output regulation includes line & load.
2. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement connection to the
unit is made with a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel.
3. Transient recovery is measured to within a 1% error band for a load step change of
50% to 100%.
4. Isolation specifications are production HI-Pot tested for 3 seconds.
(U)
20.00A
20.00A
8.33A
5.55A
4.16A
2.08A
0.0A
0.0A
0.0A
0.0A
0.0A
0.0A
Ripple &
Noise
Efficiency
50 mV p-p
50 mV p-p
±1% p-p
±1% p-p
±1% p-p
±1% p-p
70%
75%
80%
83%
83%
83%
Input Connector CN3:
Mating Molex Part No. 09-91-0500 (5 pin, 3 used) or Howder
Terminal Block No. HD-603-3P (3-pin) or equivalent.
(Note 7)
Output Connector CN2:
Mating Molex Part No. 09-91-0600 (6 pin) or Howder Terminal
Block No. HD-601-4P (4-pin) or equivalent.
Output Pin Assignment:
5. The full output range (see table above) is covered in the safety
agency certification. Standard models are factory set to the
“Preset” voltage. This may be set to other levels within the range
without affecting the agency certification. For more information,
contact the factory.
6. Units will provide peak power of 600W for 500 µS. For units
capable of longer durations, contact the factory.
7. A 1% minimum load is required to maintain regulation and ripple
specifications.
Howder
Molex
Pins 1 ~ 2: V+
Pins 1 ~ 3: V+
Pins 3 ~ 4: V-
Pins 4 ~ 6: V-
Logic Signal Connector CN1:
Mating JST XHP-3 or equivalent (CHYAO SHIUNN
JS-2001-03).
Fan driver connector (FAN):
12 VDC / 300 mA is available to drive an external fan. Mating
JST XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02).
Mechanical Dimensions: U-Chassis (U Suffix)
U-Chassis Cover (C Suffix)
U-Chassis Cover/W Fan (F Suffix)
U-Chassis Alternate Cover (B Suffix)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages