MACOM MAAPSS0076TR-3000 Dect power amplifier 1880 - 1930 mhz Datasheet

RoHS
Compliant
DECT Power Amplifier
1880 - 1930 MHz
MAAPSS0076
V3
Features
Functional Schematic
• Ideal for DECT Applications
• Power Set Pin for Adjustable Output Power
High Power Mode: 25.5 dBm
Low Power Mode: 17 dBm
• Power Gain: 25 dB Typical
• Voltage Supply Compensation
• Ramp Power Control
• Micro-Amp Shutdown Current
• Operates from 1.8 V to 3.6 V
• Lead-Free 3 mm 12-Lead PQFN Package
• 100% Matte Tin Plating over Copper
• Halogen-Free “Green” Mold Compound
• RoHS* Compliant and 260°C Reflow Compatible
Description
The MAAPSS0076 is a three stage power amplifier
designed for Digitally Enhanced Cordless Telephone
applications. The power amplifier is available in a
lead-free 3 mm 12-lead PQFN plastic package.
The MAAPSS0076 features an integrated power
enable pin (5) for accurate ramp control and a
separate power mode pin (2) for current savings in a
low power mode state. A voltage compensation
circuit is also included for applications where the
amplifier supply voltage is not regulated and is
directly connected to the battery.
Ordering Information 1
Pin Configuration
Pin No.
Pin Name
Description
1
RFIN
RF Input
2
VM
Power Mode
3
N/C
No Connection
4
N/C
No Connection
5
VEN
Power Enable
6
PFC
Power Flatness Control
7
RFOUT / VCC3
RF Output, 3rd Stage Supply
RFOUT / VCC3
RF Output, 3rd Stage Supply
Part Number
Package
8
MAAPSS0076TR-3000
3000 piece reel
9
RFOUT / VCC3
RF Output, 3rd Stage Supply
MAAPSS0076SMB
Sample Test Board
(Includes 5 Samples)
10
VCC2
2nd Stage Supply
11
PMC
Power Mode Control
VCC1
1st Stage Supply
GND
RF & DC Ground
1. Reference Application Note M513 for reel size information.
12
Pad
2
2. The exposed pad centered on the package bottom must be
connected to RF and DC ground.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
RoHS
Compliant
DECT Power Amplifier
1880 - 1930 MHz
MAAPSS0076
V3
Electrical Specifications: F = 1900 MHz, PIN = 0 dBm, VCC = 2.4 V, TA = 25 °C, Z0 = 50 Ω
Parameter
Test Conditions
Units
Min.
Typ.
Max.
Input Return Loss
VM = 0 V
VM = 2.5 V
VM = 2.5 V, VCC = 3.0 V
VCC = 2.4 V
VCC = 2.0 V
VCC = 1.8 V
TA = 0 °C to 50 °C, VCC = 2.4 V
dB
dB
dBm
dBm
dBm
dBm
dB
—
—
—
—
23
—
—
11
8
26.5
25.5
24.0
23.5
0.8
—
—
27
—
—
—
—
POUT, High Power Mode (HPM)
POUT vs. Temperature, HPM
POUT vs. VEN
VEN = 1.9 to 2.5 V
dB
—
1.2
—
Current, HPM
VM = 2.5 V, VCC = 3.0 V
mA
—
320
400
VM = 0 V, VCC = 2.4 V
dBm
14
17
—
140
200
1
10
POUT, Low Power Mode (LPM)
Current, LPM
VM = 0 V, VCC = 2.4 V
mA
—
Current, Shutdown
VCC = 3.0 V, VEN = 0.5 V
µA
—
V
V
mA
mA
dBc
dBc
dB
0
2.0
—
—
—
—
µS
µS
—
—
Control Pins
VEN, VM low
VEN, VM high
VM current
VEN current
VM = 2.5 V, VCC = 2.4 V
Harmonics
Forward Isolation
Stability
VEN = 0 V
+1.5 V < VCC < +3.5 V, POUT = HPM & LPM, VSWR < 6:1
-20°C < TA < +70ºC, RBW = 3 MHz max. hold
Turn on/off time
ton: RF burst to (Avg Power – 1 dB)
toff: (Avg Power – 1 dB) to RF off
Absolute Maximum Ratings 3,4
Parameter
Input Power
3.
4.
2fo
3fo
—
0.5
—
2.5
—
1.0
—
3.0
-50
—
-60
—
36
All spurs < -60 dBc
3
5
—
—
Logic Table 5
Absolute Maximum
VEN
VM
State
+ 5 dBm
0
0
OFF
0
1
OFF
1
0
LPM
1
1
HPM
Operating Supply Voltage
+4.0 Volts
Operating Control Voltage
+3.0 Volts
Operating Temperature
-20 °C to +85 °C
Channel Temperature
+150 °C
Storage Temperature
-40 °C to +150 °C
Exceeding any one or combination of these limits may
cause permanent damage to this device.
M/A-COM does not recommend sustained operation near
these survivability limits.
5. 1 = +2.0 V to 2.5 V, 0 = 0 V to 0.5 V.
Operating the MAAPSS0076
The MAAPSS0076 is sensitive to electrostatic
discharge (ESD).
Use proper ESD control
techniques when handling this device. To operate
the MAAPSS0076, follow these steps. Ramp down
or shut down in reverse order.
1. Apply VCC (2.4 V).
2. Apply VM (0 or 2.5 V).
3. Apply PIN (-2 to 2 dBm).
4. Ramp VEN from 0 to 2.5 V.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
RoHS
Compliant
DECT Power Amplifier
1880 - 1930 MHz
MAAPSS0076
V3
High Power Mode Typical Performance, VM = 2.5 V (using the supplied sample board BOM)
POUT, PAE, ICC vs. VCC @ 1900 MHz
POUT, PAE, ICC vs. PIN @ 2.4 V, 1900 MHz
50
0.5
50
0.4
40
0.5
PAE
40
0.4
PAE
I
I
CC
30
0.3
P
20
OUT
10
0
-15
-5
0
P
0.3
OUT
0.2
20
0.2
0.1
10
0.1
0.0
-10
CC
30
5
0
1.5
2.0
2.5
P (dBm)
3.0
V
IN
CC
POUT vs. Temperature @ 1900 MHz, PIN = 0 dBm
0.0
4.0
3.5
(Volts)
ICC vs. Temperature @ 1900 MHz, PIN = 0 dBm
0.40
28
V
= 1.8 V
V
= 2.0 V
V
= 2.4 V
V
= 3.0 V
V
= 3.6 V
CC
CC
0.35
26
CC
CC
CC
0.30
24
V
= 1.8 V
V
= 2.0 V
V
= 2.4 V
V
= 3.0 V
V
= 3.6 V
CC
22
CC
CC
CC
CC
20
-20
-10
0
0.25
10
20
30
40
50
60
70
0.20
-20
-10
0
10
30
40
50
60
70
POUT, PAE, ICC vs. Frequency @ VCC = 2.4 V, PIN = 0 dBm
POUT, 2fo, 3fo vs. PIN @ 2.4 V
30
P
20
Temperature (°C)
Temperature (°C)
50
0.5
OUT
20
PAE
40
10
0.4
I
0
CC
30
P
-10
-20
0.3
OUT
20
0.2
10
0.1
2f
o
-30
3f
o
-40
-50
-15
-10
-5
0
5
P (dBm)
3
IN
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
0
1880
1890
1900
1910
1920
0.0
1930
Frequency (MHz)
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
RoHS
Compliant
DECT Power Amplifier
1880 - 1930 MHz
MAAPSS0076
V3
Low Power Mode Typical Performance, VM = 0 V (using the supplied sample board BOM)
POUT, ICC vs. VCC @ 1900 MHz
POUT, ICC vs. PIN @ 2.4 V, 1900 MHz
25
0.25
25
20
0.20
20
0.5
0.4
P
OUT
15
0.15
15
0.3
10
0.10
10
0.2
5
0.05
5
0.00
0
1.5
P
OUT
I
CC
0
-15
-10
-5
0
5
ICC
2.0
2.5
P (dBm)
3.0
V
IN
CC
POUT vs. Temperature @ 1900 MHz, PIN = 0 dBm
0.1
0.0
4.0
3.5
(Volts)
ICC vs. Temperature @ 1900 MHz, PIN = 0 dBm
0.30
30
Vcc = 1.8 V
Vcc = 2.0 V
Vcc = 2.4 V
Vcc = 3.0 V
0.20
20
Vcc = 1.8 V
10
Vcc = 3.6 V
0.10
Vcc = 2.0 V
Vcc = 2.4 V
Vcc = 3.0 V
Vcc = 3.6 V
0
-20
0
20
40
60
0.00
-20
0
20
40
60
Temperature (°C)
Temperature (°C)
S21 vs. Frequency @ VCC = 2.4 V, VM = VEN = 2.5 V
S11, S22 vs. Frequency @ VCC = 2.4 V, VM = VEN = 2.5 V
0
40
30
-10
20
10
-20
0
-10
S11 (dB)
S22 (dB)
-30
-20
-30
-40
-40
1.0
4
1.5
2.0
2.5
3.0
Frequency (GHz)
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
RoHS
Compliant
DECT Power Amplifier
1880 - 1930 MHz
MAAPSS0076
V3
Recommended PCB Configuration
T5
T2
T1
Evaluation Board Schematic
MAAPSS0076 External Parts List
Designator
Value
Foot Print
Manufacturer
Part Number
C1, C4, C9
100 nF
0402
Murata
GRM155F51C104ZA01B
C2
22 nF
0402
Murata
GRM155R71C223KA01B
C3
4 pF
0402
Murata
GRM155C1H4R0CZ01B
C5, C6
47 pF
0402
Murata
GRM1555C1H470JZ01B
C7
1 nF
0402
Murata
GRM36X7R102K50
C8, C13
1 µF
0402
Murata
GRM36Y5V104Z016AQ
C10
100 pF
0402
Murata
GRM36COG101J050AQ
C11
2 pF
0402
Murata
GRM36COG020C05OAQ
C12
1.5 pF
0402
Murata
GRM1555C1H1R5CZ01D
L1
10 nH
0402
Coilcraft
0402CS-10NXJB
R1
249 Ω
0402
Panasonic
ERJ-2RKF2490X
R2
402 Ω
0402
Panasonic
ERJ-2RKF4020X
R3
2.15 KΩ
0402
Panasonic
ERJ-2RKF2151X
Transmission Line Dimensions, 0.20 mm thick FR4
Designator
Length (mm)
Width (mm)
T1
3.76
0.35
T2
2.08
0.35
T3
0.49
0.37
T45
7.49
0.37
T5
3.05
0.35
6
2.29
0.35
T7
2.36
0.35
T6
All dimensions from package edge to center of component
(except as noted below).
5. From center of C3 to center of C11.
6. From center of C12 to center of C13.
5
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
RoHS
Compliant
DECT Power Amplifier
1880 - 1930 MHz
MAAPSS0076
V3
Lead-Free 3 mm 12-lead PQFN†
†
Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
6
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.