Memory for Plug & Play EDID Memory (For display) BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W No.09002EAT02 BR24C21,BR24C21F,BR24C21FJ,BR24C21FV ●Description TM TM BR24C21F,BR24C21FJ,BR24C21FV are serial EEPROMs that support DDC1 /DDC2 interfaces for Plug and Play displays. ●Features TM TM 1) Compatible with both DDC1 /DDC2 2) Operating voltage range: 2.5V to 5.5V 3) Page write function: 8bytes 4) Low power consumption Active (at 5V) : 1.5mA (typ) Stand-by (at 5V) : 0.1µA (typ) 5) Address auto increment function during Read operation 6) Data security Write enable feature (VCLK) Write protection at low Vcc 7) Various packages available: DIP-T8(BR24C21) / SOP8(BR24C21F) / SOP-J8(BR24C21FJ) / SSOP-B8(BR24C21FV) 8) Initial data=FFh 9) Data retention: 10years 10) Rewriting possible up to 100,000 times ●Absolute maximum ratings (Ta=25℃) Parameter Supply Voltage Power Dissipation Storage Temperature Operating Temperature Terminal Voltage Symbol VCC Pd 800 Rating -0.3~+6.5 (DIP-T8) 450 (SOP8) 450 350 Tstg Topr - Unit V *1 *2 (SOP-J8) (SSOP-B8) -65~+125 -40~+85 -0.3~VCC+0.3 *3 mW *4 ℃ ℃ V * Reduce by 8.0 mW/C over 25C (*1), 4.5mW/℃ (*2,3), and 3.5mW/℃ (*4) ●Memory cell characteristics Parameter Supply Voltage Input Voltage Symbol VCC VIN Rating 2.5~5.5 0~VCC Unit V V ●Recommended operating conditions Write/Erase Cycle Min. 100,000 Limits Typ. - Max. - Cycle Data Retention 10 - - Year Parameter www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 1/22 Unit 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Electrical characteristics - DC (Unless otherwise specified, Ta=-40℃~+85℃、VCC=2.5V~5.5V) Limits Parameter Symbol Unit Condition Min. Typ. Max. “H” Input Voltage 1 VIH1 0.7VCC V SCL, SDA “L” Input Voltage 1 VIL1 0.3VCC V SCL, SDA “H” Input Voltage 2 VIH2 2.0 V VCLK “L” Input Voltage 2 VIL2 0.8 V VCLK, VCC≧4.0V “L” Input Voltage 3 VIL3 0.2VCC V VCLK, VCC<4.0V “L” Output Voltage VOL 0.4 V SDA, IOL=3.0mA Input Leakage Current ILI -1 1 µA SCL, VCLK, VIN=0V~VCC Output Leakage Current ILO -1 1 µA SDA, VOUT=0V~VCC Operating Current ICC 3.0 mA VCC=5.5V, fSCL=400kHz Standby Current ISB 10 100 µA VCC=5.5V, SDA=SCL=VCC,VCLK=GND *1 Note: This IC is not designed to be radiation-resistant *1 Transmit-Only Mode - After power on, the BR24C21/F/FJ/FV is in Standby mode and does not provide the clock to the VCLK pin. After the clock is provided to VCLK, the device is switched from Standby to Transmit-Only Mode, and the operating current flows. Bi-directional Mode - The BR24C21/F/FJ/FV is in Standby mode after each command is performed. ●Electrical characteristics - AC (Unless otherwise specified, Ta=-40℃~+85℃,VCC=2.5V~5.5V) Standard-mode Fast-mode VCC=2.5V~5.5V VCC=2.5V~5.5V Parameter Symbol Unit Min. Typ. Max. Min. Typ. Max. fSCL - - 400 - - 100 kHz Data Clock High Period Data Clock Low Period SDA and SCL Rise Time SDA and SCL Fall Time Start Condition Hold Time Start Condition Setup Time Input Data Hold Time tHIGH tLOW tR tF tHD:STA tSU:STA tHD:DAT 0.6 1.3 0.6 0.6 0 - 0.3 0.3 - 4.0 4.7 4.0 4.7 0 - 1.0 0.3 - µs µs µs µs µs µs ns Input Data Setup Time tSU:DAT 100 - - 250 - - ns Output Data Delay Time(SCL) Stop Condition Setup Time Bus Free Time Write Cycle Time Noise Spike Width (SDA and SCL) tPD tSU:STO tBUF tWR tI 0.6 1.3 - - 0.9 10 0.1 4.0 4.7 - - 3.5 10 0.1 µs µs µs ms µs - 1.0 0.5 0.1 4.0 4.7 0 4.0 0 - - 2.0 1.0 0.1 µs µs µs µs µs µs µs µs Clock Frequency AC OPERATING CHARACTERISTICS (Transmit-Only Mode) Output Data Delay Time(VCLK) VCLK High Period VCLK Low Period VCLK Setup Time VCLK Hold Time Mode Transition Time Transmit-Only Powerup Time Noise Spike Width (VCLK) www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. tVPD tVHIGH tVLOW tVSU tVHD tVHZ tVPU tVI 0.6 1.3 0 0.6 0 - 2/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Block diagram N.C. 1 1 Kbit EEPROM ARRAY ADDRESS DECODER SLAVE・WORD 7bit DATA ADDRESS REGISTER START N.C. 3 VCC 7 VCLK 6 SCL 5 SDA 8bit 7bit N.C. 2 8 REGISTER STOP CONTROL LOGIC ACK GND 4 HIGH VOLTAGE VCC LEVEL DETECT Fig.1 Block Diagram ●Pin layout diagram VCC VCLK SCL SDA (入力) BR24C21 入出 BR24C21F BR24C21FJ BR24C21FV N.C. N.C. N.C. GND Fig.2 Pin Layout Pin Name VCC GND N.C. SCL I/O IN SDA IN/OUT VCLK IN Functions Power Supply Ground (0V) No Connection Serial Clock Input for Bi-directional Mode Slave and Word Address, *1 Serial Data Input, Serial Data Output Clock Input (Transmit-Only Mode) Write Enable (Bi-directional Mode) *1 An open drain output requires a pull-up resistor. www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 3/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Synchronous data timing tR t HIGH tF SCL SCL t SU:DAT t HD:STA t LOW t HD:DAT SDA SDA (IN) D0 ACK tWR WRITE DATA(n) t PD t BUF STOP CONDITION SDA (OUT) START CONDITION Fig.4 Write Cycle Timing START BIT STOP BIT SCL SCL tSU:STA tHD:STA tSU:STO SDA SDA STOP BIT START BIT VCLK Fig.3 Synchronous Data Timing ・SDA data is latched into the chip at the rising edge of the SCL clock. WRITE COMMAND tVSU t VHD Fig.5 Write Enable Timing ・Output data toggles at the falling edge of the SCL clock. ●Transmit-only mode ・After power is on, the BR24C21/F/FJ/FV is in Transmit-Only Mode. In this mode data can be output by providing the clock to the VCLK pin. ・When the power is on, the SCL pin needs to be set to VCC(High level). ・SDA is at high-impedance during input of the first 9 clocks. At the 10th rising clock edge of VCLK data is output. After power on, the output data is as follows: 00h address data → 01h address data → 02h address data → … The address is incremented by one, after every 9 clocks of VCLK. All addresses are output in this mode. When the counter reaches the last address, the next output data is 00h address data. (See Fig. 6) ・In this mode, the NULL bit (High data) is output between the address data and the next address data. (See Fig. 7) ・The read operation is in Transmit-Only Mode and can be started after the power is stabilized. tVHIGH tVLOW Vcc VCLK SCL tVPD 9 1 10 SDA VCLK D1 ADDRESS n DATA tVPU D7 SDA D6 D5 D4 D0 D7 NULL BIT DATA=1 D6 ADDRESS n+1 DATA D3 00h ADDRESS DATA Fig.7 Null Bit Fig.6 Transmit Only Mode www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 4/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Bi-directional mode ○Bi-directional Mode and Recovery Function ・The BR24C21/F/FJ/FV can be switched from Transmit-Only Mode to Bi-directional Mode by providing a valid High to Low transition at the SCL pin, while the state of SDA is at high-impedance. ・After a valid high to low transition on the SCL pin, the BR24C21/F/FJ/FV begins to count the VCLK clock. If the VCLK counter reaches 128 clocks without the command for Bi-directional Mode, the device reverts to Transmit-Only Mode (Recovery function). The VCLK counter is reset by providing a valid high to low transition at the SCL pin. After reversal to Transmit-Only Mode the device begins to output data (00h address data) with the 129th rising clock edge of VCLK. ・If the BR24C21/F/FJ/FV is switched from Transmit-Only Mode and receives the command for Bi-directional Mode and responds with an Acknowledge, it is impossible to revert to Transmit-Only Mode. (Power down is the only way to revert to Transmit-Only Mode.) Unless the input device code is “1010”, the device does not respond with an Acknowledge. If the VCLK counter reaches 128 clocks afterwards, it is possible to revert to Transmit-Only Mode for Recovery function. If the Master generates a STOP condition during the Slave address, before an Acknowledge is input, it is possible to revert to Transmit-Only Mode. ・When the device is switched from Transmit-Only Mode to Bi-direction Mode, the period of tVHZ needs to be held. Bi-d irectional Bi-directional T r aTransition n s i t i o n Mode M o dwith e wpossibility i t h p o s stoi b i l i t y t o rreturn e t u n to e Transmit-Only t o T r a n s mMode it-Only Mode Tra nsm it -o nl y MODE Transmit-only 1 2 3 4 T r a nTransmit-Only smit-Only MODE 127 128 129 1 VCLK BBi-directional i-directional TTransition ransitio n M o dpossibility e w i t h p to ossibility Mode with treturn o r e tto u nTransmit-Only e t o T r a nMode smit-Only Mode Transmit-oOnly Tra nsm it -o nl y 2 B i - d i rBi-directional ectional p a r m parmanently anently n<128 n VCLK SCL SCL A D DADDRESS R E S S 00h 00h tVHZ tVHZ D7 D6 D5 D4 S SDA 1 0 1 0 * * * R/W ACK SDA Fig.8 Recovery Mode Fig.9 Mode Change *Don’t care ○Bi-directional Mode START Condition ・All commands are proceeded by the START condition, which is a High to Low transition of SDA when SCL is High. ・The BR24C21/F/FJ/FV continuously monitors the SDA and SCL lines for the START condition and will not respond to any commands until this condition has been met. (See Fig. 3 Synchronous Data Timing) STOP Condition ・All commands must be terminated by a STOP condition, which is a Low to High transition of SDA when SCL is High. ・The STOP condition causes the internal write cycle to write data into the memory array after a write sequence. ・The STOP condition is also used to place the device into standby power mode after read sequences. ・A STOP condition can only be issued after the transmitting device has released the bus. (See Fig.3 Synchronous Data Timing) Device Addressing ・Following the START condition, the Master outputs the device address of the Slave to be accessed. The most significant four bits of Slave address are the “device type indentifier,” For the BR24C21/F/FJ/FV this is fixed as “1010.” ・The next three bits of the slave address are inconsequential. ・The last bit of the stream determines the operation to be performed. When set to “1”, a READ operation is selected. When set to “0”, a WRITE operation is initiated. R/W set to "0" ・ ・ ・ ・ ・ ・ ・ ・ WRITE (This bit is also set to "0" for random read operation) R/W set to "1" ・ ・ ・ ・ ・ ・ ・ ・ READ 1010 * * * _ R/W *:Don’t care ○Write Protect Function ・Write Enable (VCLK) When using the BR24C21/F/FJ/FV in Bi-directional Mode, the VCLK pin can be used as a write enable pin. Setting VCLK High allows normal write operations, while setting VCLK low prevents writing to any location in the array. (See Fig.5 Write Enable Timing) Changing VCLK from High to Low during the self-timed program operation will not halt programming of the device. www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 5/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Bidirectional mode command ○Byte Write When the Master generates a STOP condition, the BR24C21/F/FJ/FV begins the internal write cycle to the nonvolatile array. S T A R T SDA LINE W R I T E SLAVE ADDRESS 1 0 1 0 * * WORD ADDRESS WA 0 WA * 6 * R A / C W K S T O P DATA D7 D0 A C K A C K VCLK *:Don’t care Fig.10 Byte Write Cycle Timing ○Page Write If the Master transmits the next data instead of generating a STOP condition during the byte write cycle, the BR24C21/F/FJ/FV transfers from byte write function to page write function. After receipt of each word, the three lower order address bits are internally incremented by one, while the high order four bits of the word address remains constant. If the master transmits more than eight words, prior to generating the STOP condition, the address counter will “roll over,” and the previous transmitted data will be overwritten. S T A R T SDA LINE W R I T E SLAVE ADDRESS WORD ADDRESS ( ) WA * 6 1 0 1 0 *** DATA(n) WA 0 RA / C WK S T O P DATA(n+7) D0 D7 A C K D0 A C K A C K VCLK *:Don’t care Fig.11 Page Write Cycle Timing ○Current Read The BR24C21/F/FJ/FV contains an internal address counter which maintains the address of the last word accessed, incremented by one. If the last accessed address is address “n” in a Read operation, the next Read operation will access data from address “n+1” and increment the current address counter. If the last accessed address is address ”n” in a Write operation, the next Read operation will access data from address “n”. If the Master does not transfer an Acknowledge, but does generate a STOP condition, the current address read operation will only provide a single byte of data. At this point, the device discontinues transmission. (See Fig.14 Sequential Read Cycle Timing) S T A R T SDA LINE R E A D SLAVE ADRESS 1 0 1 0 * * * DATA D7 R A / C W K S T O P D0 *:Don’t care A C K Fig.12 Current Read Cycle Timing www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 6/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ○Random Read The Random read operation allows the Master to access any memory location. This operation involves a two-step process. First, the Master issues a Write command that includes the START condition and the Slave address field (with R/W set to “0”) followed by the word address of the word to be read. This procedure sets the internal address counter of the BR24C21/F/FJ/FV to the desired address. After the word address Acknowledge is received by the Master, the Master immediately re-issues a START condition followed by the Slave address field with R/W set to “1.” The device will respond with an Acknowledge and then transmit the 8-data bits stored at the addressed location. If the Master does not acknowledge the transmission but does generate the STOP condition, the IC will discontinue transmission. S T A R T SDA LINE SLAVE ADDRESS W R I T E S T A R T WORD ADDRESS(n) WA 0 WA * 6 1 0 1 0 * * * R A / C W K SLAVE ADDRESS R E A D DATA(n) 1 0 1 0 * * * A C K S T O P D7 D0 A C K R A / C W K *:Don’t care Fig.13 Random Read Cycle Timing ○Sequential Read ・If the Master does not transfer an Acknowledge and does not generate a STOP condition during the current Read operation, the BR24C21/F/FJ/FV continues to output the next address data in sequence. For Read operations, all bits in the address counter are incremented, allowing the entire array to be read during a single operation. When the counter reaches the top of the array, it will “roll over” to the bottom of the array and continue to transmit data. ・If the Master does not acknowledge the transmission but does generate a STOP condition, at this point the device discontinues transmission. ・The sequential Read operation can be performed with both Current Read and Random Read. S T A R T SDA LINE R E A D SLAVE ADDRESS 1 0 1 0 * * * DATA(n) D7 R A / C W K S T O P DATA(n+x) D0 D7 A C K A C K D0 *:Don’t care A C K Fig.14 Sequential Read Cycle Timing (Current Read) www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 7/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note BU9882-W,BU9882F-W,BU9882FV-W ●Description BU9882F-W,BU9882FV-W are dual port EEPROMs compatible with the DDC2TM. 2 independent ports allow 2 EDID channels to be read simultaneously. ●Features TM 1) Designed for use with DDC2 2) 2-port simultaneous read function 3) Operating voltage range: 2.5V-5.5V 4) Page write function: 8bytes 5) Low power consumption: Active (at 5V) : 1.5mA(typ) Stand-by (at 5V) : 0.1µA(typ) 6) Data security Write protection with WP Write protection at low power supply voltage 7) Various package types available: DIP14(BU9882-W) / SOP14(BU9882F-W) / SSOP14(BU9882FV-W) 8) Initial data: FFh 9) Data retention: 10years 10) Rewriting possible up to 100,000 times ●Absolute maximum ratings Parameter Supply Voltage Power Dissipation Storage Temperature Operating Temperature Terminal Voltage Symbol VCC Tstg Rating -0.3~+6.5 (DIP14) (SOP14) (SSOP14) -65~+125 Topr -40~+85 Pd 950 450 350 Unit V *1 *2 mW *3 ℃ ℃ *4 -0.3~VCC+1.0 * Reduce by 9.5 mW/C over 25C (*1), 4.5mW/℃(*2), 3.5mW/℃(*3). *4 6.8V (Max.) V ●Recommended operating conditions Parameter Symbol Rating Unit Supply Voltage VCC 2.5~5.5 V Input Voltage VIN 0~VCC+1.0 V ●Memory cell characteristics Write/Erase Cycle Min. 100,000 Limits Typ. - Max. - Cycle Data Retention 10 - - Year Parameter www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 8/22 Unit 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Electrical characteristics – DC (Unless otherwise specified, Ta=-40℃~+85℃,VCC=2.5V~5.5V) Limits Parameter Symbol Unit Condition Min. Typ. Max. “H” Input Voltage 1 VIH1 2.0 - - V “L” Input Voltage 1 “L” Input Voltage 2 “L” output Voltage VIL1 - VIL2 VOL1 - - 0.8 V VCC≧4.0V - 0.2VCC 0.4 V V -1 - 1 µA VCC<4.0V SDA_PC0/1, IOL=3.0mA *1 SCL_PC0/1,DDCENA, BANKSEL, VIN=0V~VCC+1.0 Input Leakage Current 1 ILI1 Input Leakage Current 2 ILI2 -1 - 50 µA Output Leakage Current ILO -1 - 1 µA Operating Current ICC - 1.5 3.0 mA Standby Current ISB - 0.1 5 µA ___ WP SDA_PC0/1,SCL/SDA_MON(DDCENA=GND), VOUT=0V~VCC+1.0 fSCL=400kHz, VCC=5.5V tWR=10ms SCL/SDA_PC0/1=VCC SCL/SDA_MON=H-Z DDCENA=WPB=BANKSEL=GND DUALPCB=VCC Note: This IC is not designed to be radiation-resistant *1 IOL at monitor mode (DDCENA=HIGH) is the sum of current flowing from the pull up resistor at the SDA_MON side to the pull up resistance at SDA_PC0/PC1 ●Electrical characteristics – AC (Unless otherwise specified, Ta=-40℃~+85℃、VCC=2.5V~5.5V) Standard-mode Fast-mode VCC=2.5V~5.5V VCC=2.5V~5.5V Parameter Symbol Min. Typ. Max. Min. Typ. Max. Clock Frequency fSCL 400 100 Data Clock High Period tHIGH 0.6 4.0 Data Clock Low Period tLOW 1.3 4.7 SDA and SCL Rise Time tR 0.3 1.0 SDA and SCL Fall Time Unit Typ. kHz µs µs µs tF - - 0.3 - - 0.3 µs Start Condition Hold Time Start Condition Setup Time tHD:STA tSU:STA 0.6 0.6 - - 4.0 4.7 - - µs µs Input Data Hold Time tHD:DAT 0 - - 0 - - ns Input Data Setup Time Output Data Delay Time(SCL) Stop Condition Setup Time Bus Free Time Write Cycle Time Noise Spike Width (SDA and SCL) tSU:DAT tPD tSU:STO tBUF tWR tI 100 0.6 1.3 - - 0.9 10 0.1 250 4.0 4.7 - - 3.5 10 0.1 ns µs µs µs ms µs www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 9/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Block diagram 1Kbit Fig.15 Block Diagram ●Pin layout diagram VCC WP DUALPCB BANKSEL DDCENA SCL_MON SDA_MON BU9882-W BU9882F-W BU9882FV-W SCL_PC0 SDA_PC0 ●Pin description Pin Name N.C. SCL_PC1 SDA_PC1 N.C. GND Fig.16 Pin Layout I/O Functions VCC - Power Supply GND - Ground (0V) N.C. - No Connection SCL_PC0 IN SDA_PC0 IN/OUT SCL_PC1 IN SDA_PC1 IN/OUT SCL_MON OUT SDA_MON OUT DDCENA IN Control of SCL_MON, SDA_MON BANKSEL IN Select a SCL/SDA_MON Connected Port at DUAL PORT mode Selected a BANK at SINGLE PORT mode DUALPCB IN Control of DUAL PORT/SINGLE PORT mode IN Write Protect Control ――― wp Serial Clock Input, Access to BANK0 at DUAL PORT mode Access to BANK0 or to BANK1 at SINGLE PORT mode Slave and Word Address Serial Data Input, Serial Data Output Access to BANK0 at DUAL PORT mode, Access to BANK0 or to BANK1 at SINGLE PORT mode Serial Clock Input Access to BANK1 at DUAL PORT mode, Don't Care at SINGLE PORT mode Slave and Word Address Serial Data Input, Serial Data Output Access to BANK1 at DUAL PORT mode, Don't Care at SINGLE PORT mode Serial Clock Output Connected to SCL_PC0/1 at DDCENA="High", "Hi-Z" output at DDCENA="Low" Slave and Word Address Serial Data Output Connected to SCL_PC0/1 DDCENA="High", "Hi-Z" output at DDCENA="Low" An open drain output requires a pull-up resistor. www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 10/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Synchronous data timing tF tR tHIGH SCL SCL tHD:STA tSU:DAT tHD:DAT tLOW SDA (IN) tBUF tSU:STA tHD:STA tSU:STO SDA tPD SDA (OUT) START BIT STOP BIT Fig.17 Synchronous Data Timing ・SDA data is latched into the chip at the rising edge of the SCL clock. ・The output date toggles at the falling edge of the SCL clock. ●Write cycle timing SCL SDA D0 ACK tWR WRITE DATA (n) STOP CONDITION START CONDITION Fig.18 Write Cycle Timing ●Operation notes ○DDCENA Operation When DDCENA is set to High, SCL_PC0/1 and SDA_PC0/1 will be connected to SCL_MON and SDA_MON, respectively. Therefore, monitoring of the communications between the PC and EEPROM, and the communications of the MONITOR and PC, is possible. Selection of PC0/PC1 is determined according to the state of the DUALPCB and BANKSEL inputs. When DDCENA is Low, the SCL/SDA_MON output is set to "Hi-Z". SCL_MON,SDA_MON DUALPCB BANKSEL (CONNECTION PORT) Low PC0 PORT Low (DUAL PORT) High PC1 PORT Low High (SINGLE PORT) PC0 PORT High ○BANKSEL BANKSEL serves as an input for connection port of SCL/SDA_MON during DUAL PORT mode. It turns into the BANK selection terminal of internal memory in SINGLE PORT mode. Only the PC0 port can access the memory in SINGLE PORT mode. DUALPCB Low (DUAL PORT) High (SINGL PORT) BANKSEL Low High Low High CONNECTION BANK PC0 PORT:BANK0 PC1 PORT:BANK1 BANK0 BANK1 ○WP When WP=Low, all data at all addresses are write-protected. The terminal has a built-in pull down resister. Make sure that WP=High when writing data. Utilize this function in order to prevent incorrect write command input from the PC, as well as incorrect input during communication between the PC and monitor. www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 11/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ○Data Read The data read function allows simultaneous read from SCL_PC0/1, SDA_PC0/1 in DUAL PORT mode. ○Data Write Write operation is performed using either PC0/1 (SCL or SDA) even when accessed simultaneously in DUAL PORT mode. Port selection is made by detecting the data D0 of the first byte of the WRITE command input. After this, the other port is made unavailable for both READ and WRITE commands until the write operation is completed. S T A R T SDA_PC W R I T E SLAVE ADDRESS 1 0 1 0 0 0 *:Don’t care WORD ADDRESS 0 * WA 6 WA 0 R A / C W K S T O P DATA D7 D0 A C K A C K D0 detected first write operation performed through the port During other port is write command. this ack is no output. Fig.19 Write Cycle Timing ○START Condition All commands are preceeded by the START condition, which is a High to Low transition of SDA when SCL is High. This IC continuously monitors the SDA and SCL lines for the START condition and will not respond to any commands until this condition has been met. ○STOP Condition All commands must be terminated by a STOP condition, which is a Low to High transition of SDA when SCL is HIGH. (See Fig.17) ○WRITE Command Unless a STOP condition is executed, the data will not be written into the memory array. ○DEVICE ADDRESSING Following a START condition, the Master outputs the device address of the slave to be accessed. The most significant four bits of the Slave address are the "device type indentifier". For the IC this is fixed as "1010". The next three bits are "000". The last bit of the stream determines the operation to be performed. When set to "1", Read operation is selected ; when set to "0", Write operation is selected. R/W set to "0" ・ ・ ・ ・ ・ ・ ・ ・ WRITE R/W set to "1" ・ ・ ・ ・ ・ ・ ・ ・ READ 1010 www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 0 0 ― 0 R/W 12/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Commands ○Byte Write When the Master generates a STOP condition, the IC begins an internal write cycle to the nonvolatile array. S T A R T W R I T E SLAVE ADDRESS SDA LINE 1 0 1 0 0 0 WORD ADDRESS 0 * WA 0 WA 6 R A / C W K S T O P DATA D7 D0 A C K A C K *:Don’t care Fig.20 Byte Write Cycle Timing ○Page Write After the receipt of each word, the three low order address bits are internally increased by one. The four higher order bits of the address(WA6~WA3) remain constant. This IC is capable of eight byte page write operation. If the master transnmits more than eight words, prior to generating the STOP condition, the address counter will "roll over", and the previous transmitted data will be overwritten. S T A R T SDA LINE W R I T E SLAVE ADDRESS WORD ADDRESS ( ) WA * 6 1 0 1 0 0 0 0 R / W WA 0 D7 D0 A C K A C K S T O P DATA(n+7) DATA(n) D0 A C K A C K *:Don’t care Fig.21 Page Write Cycle Timing ○Current Read In case the previous operation is random or current read (which includes sequential read), the internal address counter is increased by one from the last acceseed address (n). Thus current read outputs the data of the next word address (n+1). If the last command is byte or page write, the internal address stays at the last address(n). Thus current read outputs the data of the word address (n). If the master does not transfer the Acknowledge, but does generate a stop condition, the current address read operation only provides a single byte of data. At this point, the BU9882/F/FV-W discontinues transmission. S T A R T SLAVE ADRESS SDA LINE R E A D S T O P DATA 1 0 1 0 0 0 0 D7 D0 R A / C W K A C K Fig.22 Current Read Cycle Timing ○Random Read Random read operation allows the master to access any location.If the master does not transfer the Acknowledge but does generate a stop condition, the current address read operation only provides a single byte of data. (At 1Kbit all address read possible).This communication must be terminated by a stop condition, which is a Low to High transition of SDA when SCL is High S T A R T SDA LINE SLAVE ADDRESS W R I T E WORD ADDRESS ( ) WA * 6 1 0 1 0 0 0 0 R A / C W K S T A R T WA 0 SLAVE ADDRESS R E A D 1 0 1 0 0 0 0 A C K DATA(n) D7 R A / C W K S T O P D0 A C K *:Don’t care Fig.23 Random Read Cycle Timing www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 13/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ○Sequential Read During the Current read operation, if an Acknowledge is detected, and no STOP condition is generated by the master(µ-COM), the device will continue to transmit the data. (It can transmit all data(1Kbit 128word)). If an Acknowledge is not detected, the devive will terminate further data transmissions and await a STOP condition before returning to the standby mode. The Sequential Read operation can be performed with both Current Read and Random Read. S T A R T SDA LINE R E A D SLAVE ADDRESS DATA(n) 1 0 1 0 0 0 0 D7 S T O P DATA(n+x) D0 R A / C W K D7 A C K D0 A C K A C K Fig.24 Sequential Read Cycle Timing ●Peripheral Circuits ○DUAL PORT DUAL PORTs are used to connect two PCs to one monitor. PC0 is connected to BANK0 and PC1 to BANK1. Each bank operates as 1Kbit EEPROM. ○ To Use DUAL PORT Start the operation of the DUAL PORT by following the instructions below: 1. Set the DUAL PCB to LOW with neither of the ports being operated by commands. 2. Input the command from PC0 or PC1. ○ Simultaneous Access <READ OPERATION> EEPROM data read allows simultaneous access from PC0, PC1 ports. <WRITE OPERATION> Write operation is performed for either of PC0/1 even when accessed simultaneously from both. Port selection is made by detecting the data D0 of the first byte of the WRITE command input. Write operation is performed only for the port where D0 of the first byte of the write data is detected first. PC 0 MONITOR VCC SCL SDA VCC SCL_PC0 BANK0 (1kbit) SDA_PC0 DUALPCB NC BANKSEL SCL_PC1 BANK1 (1kbit) SDA_PC1 PC 1 WP WPB CPU DDCENA NC SCL_MON GND SDA_MON SCL SDA Fig.25 Example of Peripheral Circuit with Dual Port S T A R T SDA-PC0 BUS SLAVE ADDRESS 1 1 R A / C W K Output Data from BANK0 D7 D0 Write operation performed Through the port. S T A R T S A T C O K P SDA-PC0 BUS SLAVE ADDRESS 1 R / W *WA6 *WA 6 1 S T O P BANK0 WORD ADDRESS(W) WA0 WA 0 D7 D0 S T O P Output Data from BANK1 SDA-PC1 BUS SDA-PC1 BUS BANK1 WORD ADDRESS(W) Output Data from BANK1 1 1 D7 D0 1 1 D7 D0 Fig.26 SIMULTANEOUS ACCESS OF READ OPERATION SDA-PC1 BUS www.rohm.com 1 *WA6 WA0 D7 Fig.27 Simultaneous Access Fig.27 Simultaneous Of Write Operation Access of White Operation Fig.26 Simultaneous Access of Read Operation © 2009 ROHM Co., Ltd. All rights reserved. 1 14/22 D0 No ACK *:Don’t care 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ○MONITOR OUTPUT BU9882F-W, BU9882FV-W has a monitor output terminal. This allows communication between the PC and monitor CPU. The monitor output for the use of DUAL PORT can be switched with BANKSEL input, as shown in the table below. BANKSEL input Low High SCL_MON,SDA_MON connection port PC0 PORT PC1 PORT ○SINGLE PORT SINGLE PORT is for connecting one PC to one monitor. In this case, it is accessible only from PC0. BANK selection is made with BANKSEL. Switching this BANKSEL allows access to the total of 2kbit EEPROM, with BANK0 and BANK1, from PC0. ○ To use SINGLE PORT Start the SINGLE PORT operation by following the instructions below: 1. Set the DUAL PCB to High with neither of the ports being operated by commands. 2. Select the BANK with BANKSEL. 3. Input the command from PC0. PC 0 MONITOR VCC SCL SDA VCC SCL_PC0 SDA_PC0 BANK0 (1kbit) NC WP DUALPCB BANKSEL SCL_PC1 SDA_PC1 BANK1 (1kbit) DDCENA CPU SCL_MON NC SDA_MON GND Fig.28 Example of Peripheral Circuit with Single Port www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 15/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note Common Application Note ●Software Reset Execute software reset in case the device is at an unexpected state after power up and/or the command input needs to be reset. The following figures (Fig.29-(a), Fig.29-(b), Fig.29-(c)) During dummy clock, please release SDA BUS (tied to Vcc by pull up resistor). During that time, the device may pull the SDA line Low for acknowledge or outputting read data. If the master controls the SDA line High, it will conflict with the device output Low then it makes a current overload. It may cause instantaneous power down and may damage the device. Start×2 Dummy Clock×14 SCL 2 1 13 14 COMMAND SDA COMMAND Fig.29-(a) Dummy Clock×14+Start+Start Start Start Dummy Clock×9 1 SCL 2 8 9 COMMAND SDA COMMAND Fig.29-(b) Start+Dummy Clock×9+Start Start×9 SCL 2 1 7 3 8 9 COMMAND SDA COMMAND Fig.29-(c) Start×9 ●Acknowledge Polling Since the device ignores all input commands during the internal write cycle, no ACK will be returned. When the master sends the next command following the write command, and the device returns the ACK, it means that the program is completed. If no ACK is returned, it means that the device is still busy. By using Acknowledge polling, the waiting time is minimized to less than tWR=5ms. To prevent operating Write or Current Read immediately after Write, first send the slave address (R/W is "High" or "Low"). After the device returns the ACK, continue word address input or data output, respectively. During the internal write cycle, no ACK will be returned. (ACK=High) THE FIRST WRITE COMMAND S T A WRITE COMMAND R T S T O P S T SLAVE A R ADDRESS T S T SLAVE A R ADDRESS T A C K H A C K H … tWR THE SECOND WRITE COMMAND … S A T SLAVE C A R ADDRESS K H T S A T SLAVE C A K ADDRESS R L T tWR WORD ADDRESS A C K L DATA A C K L S T O P After the internal write cycle is completed ACK will be returned (ACK=Low). Then input next Word Address and data. Fig.30 Successive Write Operation By Acknowledge Polling www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 16/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Command Cancellation By Start And Stop Condition During a command input, command is canceled by the successive inputs of start condition and stop condition (Fig.31). However, during ACK or data output, the device may output the SDA line Low. In such cases, operation of start and stop condition is impossible, making the reset inoperable. Execute the software reset in the cases. (Fig.29) Operating the command cancel by start and stop condition during the command of Random Read or Sequential Read or Current Read, internal address counter is not confirmed. Therefore operation of Current Read after this is not valid. Operate a Random Read in this case. SCL SDA 1 0 1 0 Start Condition Stop Condition Fig.31 Command Cancellation ●I/O Circuit ○SDA Pin Pull-up Resister The pull up resister is needed because SDA is NMOS open drain. Choose the correct value of this resister(RPU), by considering VIL, IL characteristics of a controller which control the device and VOH, IOL characteristics of the device. If large RPU is chosen, clock frequency needs to be slow. In case of small RPU, the operating current increases. ○Maximum Rpu Maximum value of RPU is determined by following factors: ①SDA rise time determined by RPU and the capacitance of bus line(CBUS) must be less than tR. Other timing must keep the conditions of AC spec. A of SDA bus determined by a total input leak(IL) of the all devices connected to ②When SDA bus is High, the voltage ○ the bus. RPU must be significantly higher than the High level input of a controller and the device, including a noise margin 0.2VCC. VCC-ILRPU-0.2 VCC ≧ VIH MICRO COMPUTER 0.8Vcc-VIH ∴ ≦ RPU RPU IL A Examples: When VCC=3V IL=10µA VIH=0.7VCC According to ② 0.8x3-0.7x3 ≦ RPU 10x10-6 ≦ 300 [kΩ] IL SDA PIN IL THE CAPACITANCE OF BUS LINE (CBUS) Fig.32 I/O Circuits www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 17/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ○Minimum RPU The minimum value of RPU is determined by following factors: ①Meets the condition that VOLMAX=0.4V, IOLMAX=3mA when the output is Low. VCC -VOL ≦ IOL R PU VCC -VOL IOL ② VOLMAX=0.4V must be lower than the input Low level of the microcontroller and the EEPROM including the recommended noise margin of 0.1VCC. VOLMAX ≦ VIL-0.1 VCC Examples: VCC=3V, VOL=0.4V, IOL=3mA, the VIL of the controller and According to ① ∴ R PU ≧ RPU ≧ 3-0.4 3×10 -3 ≧ 867 [Ω] the EEPROM is VIL=0.3VCC, VOL=0.4[V] VIL=0.3×3 =0.9[V] so that condition② is met and ○SCL Pin Pull-up Resister When SCL is controlled by the CMOS output the pull-up resistor at SCL is not required. However, should SCL be set to Hi-Z, connection of a pull-up resistor between SCL and VCC is recommended. Several kΩ are recommended for the pull-up resistor in order to drive the output port of the microcontroller. www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 18/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Notes For Power Supply VCC rises through the low voltage region in which the internal circuit of the IC and the controller are unstable. Therefore, the device may not work properly due to an incomplete reset of the internal circuit. To prevent this, the device has a P.O.R. and LVCC feature. At power up, maintain the following conditions to ensure functions of P.O.R and LVCC. 1. "SDA='H'" and "SCL='L' or 'H'". 2. Follow the recommended conditions of tR, tOFF, Vbot for the P.O.R. function during power up. tR VCC Recommended conditions of tR, tOFF, Vbot tOFF tR tOFF Vbot Below 10ms Above 10ms Below 0.3V Below 100ms Above 10ms Below 0.2V Vbot 0 Fig.33 Vcc rising wave from 3. Prevent SDA and SCL from being "Hi-Z". In case conditions 1 and/or 2 cannot be met, take following actions: A)If unable to keep condition 1 ( SDA is "Low" during power up): →Control SDA ,SCL to be "High" as shown in figure below. VCC tLOW SCL SDA After Vcc becoms stable After Vcc becoms stable tDH tSU:DAT tSU:DAT Fig.34 SCL="H" and SDA="L" Fig.35 SCL="L" and SDA="L" B)If unable to keep condition 2. →After power becomes stable, execute software reset. (See Fig.29) C)If unable to keep both conditions 1 and 2. →Follow the instruction A first, then the instruction B. ●LVCC Circuit LVCC circuit inhibits write operation at low voltage, and prevents an inadvertent write. Write operation is inhibited below the LVCC voltage (Typ.=1.2V). ●Vcc NOISE ○Bypass Condenser Noise and surges on power line may cause abnormal function. It is recommended that the bypass condensers (0.1µF) are attached on the Vcc and GND line beside the device. It is also recommended to attach bypass condensers on the board close to the connector. www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 19/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Notes for Use 1) Described numeric values and data are design representative values, and the values are not guaranteed. 2) We believe that application circuit examples are recommendable, however, in actual use, confirm characteristics further sufficiently. In the case of use by changing the fixed number of external parts, make your decision with sufficient margin in consideration of static characteristics and transition characteristics and fluctuations of external parts and our LSI. 3) Absolute maximum ratings If the absolute maximum ratings such as impressed voltage and operating temperature range and so forth are exceeded, LSI may be destructed. Do not impress voltage and temperature exceeding the absolute maximum ratings. In the case of fear exceeding the absolute maximum ratings, take physical safety countermeasures such as fuses, and see to it that conditions exceeding the absolute maximum ratings should not be impressed to LSI. 4) GND electric potential Set the voltage of GND terminal lowest at any action condition. Make sure that each terminal voltages is lower than that of GND terminal. 5) Heat design In consideration of permissible dissipation in actual use condition, carry out heat design with sufficient margin. 6) Terminal to terminal shortcircuit and wrong packaging When to package LSI onto a board, pay sufficient attention to LSI direction and displacement. Wrong packaging may destruct LSI. And in the case of shortcircuit between LSI terminals and terminals and power source, terminal and GND owing to foreign matter, LSI may be destructed. 7) Use in a strong electromagnetic field may cause malfunction, therefore, evaluated design sufficiently www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 20/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W Technical Note ●Ordering part number B R 2 ROHM type 4 C BUS type 2 Product type 24:I2C 1 F Capacity - Package 21= 1K F : SOP8 E 2 Packaging and forming specification E2: Embossed tape and reel FJ : SOP-J8 FV : SSOP-B8 SOP8 <Tape and Reel information> 5.0±0.2 (MAX 5.35 include BURR) 6 +6° 4° −4° 5 4.4±0.2 6.2±0.3 1 2 3 0.9±0.15 7 0.3MIN 8 Tape Embossed carrier tape Quantity 2500pcs Direction of feed E2 The direction is the 1pin of product is at the upper left when you hold ( reel on the left hand and you pull out the tape on the right hand ) 4 0.595 1.5±0.1 +0.1 0.17 -0.05 0.11 S 1.27 0.42±0.1 1pin Reel (Unit : mm) Direction of feed ∗ Order quantity needs to be multiple of the minimum quantity. SOP-J8 <Tape and Reel information> 4.9±0.2 (MAX 5.25 include BURR) +6° 4° −4° 6 5 0.45MIN 7 3.9±0.2 6.0±0.3 8 1 2 3 Tape Embossed carrier tape Quantity 2500pcs Direction of feed E2 The direction is the 1pin of product is at the upper left when you hold ( reel on the left hand and you pull out the tape on the right hand ) 4 0.545 0.2±0.1 0.175 1.375±0.1 S 1.27 0.42±0.1 0.1 S 1pin Reel (Unit : mm) Direction of feed ∗ Order quantity needs to be multiple of the minimum quantity. SSOP-B8 <Tape and Reel information> 3.0 ± 0.2 (MAX 3.35 include BURR) 0.3MIN 4.4±0.2 6.4±0.3 8 76 5 Tape Embossed carrier tape Quantity 2500pcs Direction of feed E2 The direction is the 1pin of product is at the upper left when you hold ( reel on the left hand and you pull out the tape on the right hand ) 1.15±0.1 1 23 4 0.15 ± 0.1 0.1 S 0.1 +0.06 0.22 -0.04 (0.52) 0.08 M 0.65 1pin (Unit : mm) Reel Direction of feed ∗ Order quantity needs to be multiple of the minimum quantity. . www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. 21/22 2009.04 - Rev.A BR24C21,BR24C21F,BR24C21FJ,BR24C21FV, BU9882-W,BU9882F-W,BU9882FV-W B U 9 ROHM type 8 8 Technical Note 2 F Part No. V - W E 2 W: Double cell Packaging and forming specification E2: Embossed tape and reel Package F : SOP14 FV : SSOP-B14 SOP14 <Tape and Reel information> 8.7 ± 0.2 (MAX 9.05 include BURR) 8 Tape Embossed carrier tape Quantity 2500pcs Direction of feed 0.3MIN 4.4±0.2 6.2±0.3 14 1 E2 The direction is the 1pin of product is at the upper left when you hold ( reel on the left hand and you pull out the tape on the right hand ) 7 1.5±0.1 0.15 ± 0.1 0.4 ± 0.1 0.11 1.27 0.1 1pin Reel (Unit : mm) Direction of feed ∗ Order quantity needs to be multiple of the minimum quantity. SSOP-B14 <Tape and Reel information> 5.0 ± 0.2 8 0.3Min. 4.4 ± 0.2 6.4 ± 0.3 14 1 Tape Embossed carrier tape Quantity 2500pcs Direction of feed E2 The direction is the 1pin of product is at the upper left when you hold ( reel on the left hand and you pull out the tape on the right hand ) 7 0.10 1.15 ± 0.1 0.15 ± 0.1 0.65 0.1 0.22 ± 0.1 1pin (Unit : mm) www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. Reel 22/22 Direction of feed ∗ Order quantity needs to be multiple of the minimum quantity. 2009.04 - Rev.A Notice Notes No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuel-controller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law. Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us. ROHM Customer Support System http://www.rohm.com/contact/ www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. R0039A